Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permits - Permit# SP-2021-00068 - 4364 West Arm Road - 12/13/2021
City of Spring Park Permit CCTV Of P Rr -1 1\1 �"AR 11'1� i _r_x_ - - #AINK ISO IA To Schedule an Inspection Call: 952-442-7520 Details Permit Number: SP-2021-00068 Issue Date: 12/13/2021 Zoning Type: RESIDENTIAL Use Type: 24 HOUR NOTICE REQUIRED FOR ALL INSPECTIONS ♦ MON-FRI: 8AM-4:30PM • NO HOLIDAYS Site Address: 4364 WEST ARM ROAD, SP, MN 55384 Description: Replace Siding and Roof Permit Granted To: Homeowner's Name: BARBARA K WARD Phone Number: Parcel #: 1811723430057 Permit Type: BLDG - Misc Repair Permit Exp: 12/28/2021 Valuation: $17,000.00 Fees Receipt # Product Sale Date Quantity Date Paid Status Pmt Info Amount 14512 —Permit Fee 7/1/2021 1.00 12/13/2021 Paid Check: 4240 $92.19 Total: $92.19 Notes • This permit is issued in accordance with and subject to all provisions of Ordinances and policies governing building and zoning in City of Spring Park. • Permit Holder/Contractor/Owners Agent is responsible to call for the inspections! • Permit Packet, including approved plan, and this inspection record must be posted in an accessible location before calling for inspection. Maintain this inspection record until work is complete. • No deviations from the approved plans are allowed without prior consent from the building inspections department. • To Owner, Occupant, or Contractor: It is ILLEGAL TO OCCUPY this area/building until all required final inspections have been made, approved, signed, and certificate of occupancy issued! Scott Qualle, Building Official City of Spring Park #4349 Warren Avenue ♦ 55384 Copyright ©2021 INSPECTION RECORD 2020 MN State Building Code City of Spring Park Permit Number: SP-2021-00068 SITE ADDRESS: 4364 WEST ARM ROAD, SP, MN 55384 PERMIT TYPE: BLDG - Misc Repair ZONE/USE TYPE: RESIDENTIAL APPLICANT: BARBARA K WARD OWNER: BARBARA K WARD Replace Siding and Roof Issue Date:12/13/2021 Description: No inspection will be performed, and a re -inspection fee will be charged, if this 'Inspection Record", the "City of Spring Park Permit", and, when applicable, the approved plans are not available to the inspector. This permit expires if construction activity does not commence within 180 days from obtaining this permit; when construction activity has been suspended or abandoned for at least 180 days; or the work has not been inspected within 180 days from the last documented activity. IF SEPARATE PERMITS ARE REQUIRED, REFER TO THE "SEPARATE PERMITS REQUIRED FOR:" STAMP ON YOUR APPROVED PLANS/CONSTRUCTION DOCUMENTS TO IDENTIFY WHAT SEPARATE PERMITS ARE REQUIRED. ALL REQUIRED ROUGH -IN INSPECTIONS, NOTED ON SEPARATE PERMITS, MUST BE COMPLETED PRIOR TO SCHEDULING A FRAMING INSPECTION. ALL REQUIRED FINAL INSPECTIONS, NOTED ON SEPARATE PERMITS, MUST BE COMPLETED PRIOR TO SCHEDULING A BUILDING FINAL INSPECTION. DO NOT COVER ITEMS TO BE INSPECTED. Permit Card (4) Status Meeting/SiteVisit 11/23: Roof cannot determine if it has been replaced. Appears siding has been patched and painted. Inspection Trailer present with old siding on -site with paint cans. (TR) Re -Side In- Required Process Re -Roof In- Required Process Final Required MUST CALL TO SCHEDULE NO LATER THAN THE BUSINESS DAY PRIOR TO THE INSPECTION DAY: 8:00 A.M. TO 4:30 P.M. MONDAY THRU FRIDAY. PHONE NUMBER TO CALL: 952-442-7520 When a Certificate of Occupancy is needed, return this card and the approved final inspection notice to the City of Spring Park office. CITY OF SPRING PARK PAGE 1 BUILDING PERMIT 4349 Warren Avenue sP-2021-00068 Spring Park, MN 55384 El Handout Given Phone: 952-471-0051 Fax.- 952-471-9160 ❑ Lead Handout Given Routed to MNSPECT �SITE ADDRESS: �ta/e �{'M U, PID: 1) Was the home constructed before 1978'2 (YES a, continue with line 2, NOxoontinue wdhout completing EPA Section) 2) Wig the work disturb z8 sq ft of interior painted surfaces or Y20 sq ft of exterwr painted surfaces? (YES o go to tine 4. NO o hne 3) 3) Are there any windows being replaced? (YES a, go to line 4, NO a continue without oompletlnp EPA Section) 4) Has this home been Certified Lead Free? (YES o, you MUST Attach Certification Information, NO a complete line 5) 6) EPA Contractor CarMicalton Number NAT - (Wbw to contractor only) PROPERTY OVIMER: Address .. State: W ZJ . Email. g o r+rA .aosAc,.A 0 Ll v.- "iM- Contact Name Phone OIL -41112 • CONTRACTOR: Address: State: Zlix Phone: F :: Contractor License No: Contact Nam: :t�ttone"' �dfR Email:;. ARCHITECT. Address: CityState: Zi : Phone: Falc . Email: Contact Name. _ Phone: TYPE OF WORK: o NowConstnxdlon ❑ Deck , ❑ Pool `fit; =' ' pRe-Roof Commercial ❑ Residential ❑ Change or Use ❑ Retaiijipg Wall,.: o Porch r,rRe-Side EST. VALUATION OF WORK ❑ Finish Basement QA;a moii6ow o Fence S al n , 0ty — o Remodel n Fuk'aBprink dr , : o Shed Square twat a Addition o :F;aiaAlerm '= ❑ Window/Door Replacement a GaMgg-AttaghMM3'0*ft,-.OIuMbing-problde Well on Pape 2 Ar being replaced Oallalled Description of Work: o Accesso %lfi'xWre v ❑ Mechanaal-p"wide aelef on Page 2 a Mist Other r - , .;,. �, gnepn erode si plloelbn by ee lepai plopelgrowfer orb ftormwd os tiniepreaerdaWe, r �yui.a end authorlaN lie aonYq AdmYdetsitor a dnlprea arctic desires to de open to pmpotf b pm Im., needed ggiclone. &r mar boloom pit► halve. r bo" ulgioeYilp the! I here reed tMs eppkdm and am@ Ines ae hdb bus and eoeaet to tee bead mir trroe egpL I father alime the el wok peAbrdtlerua orer molt"" OW Ile kwn atria 811010 Of' I I in ill eatlaw taken poomma to lue pe me. i eposto pry eA plan nNbw%n .vas Ir 1 ch000e not to pmosed with &A wadi. PMat eapkee whet wwk to Is not somm6mod vM*i 110 dwp from daU d peaak dr # VMk 4 euepa ft abandoned, or nol ltepooled fin 180 dare. Work beyond the seope of tide permit or wak %thaut o porme or tepeothn, • welbeu6Jaottoeponey. Noise tkdklafiel to Eflisa'btiiIONDAY - FRIDAY Before 7 em. curd after 10 pm. Weell KWHolidaye before 7 a.m. and efber 9 p.m. s SURMTURE OF AP �,:: ` k DATE: PRW +�� This b t11e af: Owner or a4 Owner's OCCUR TYPE: CONST. TYPE: CODE: BLDG SMNKLED Yes / No VALUATION:,$ 17 000.00 Permit Fee: $ 92.19 WAC Charge: S Plan Review Fee: $ Sewer & Water Hook -Up: S State Surcharge: S Sewer & Water Disconnect S Site Inspection Fee: S Water Meter: $ S.E_C. Fee: $ Muni SEIWA Fee: $ Investigation Fee / Other Fee: $ '2016 SAC Escrow. 22 4$5 Copy Charge (S25 per8.5 x11 page) S Other. $ Llconso Chock ($5)1 Load Chock ($5) $ TOTAL DUE: $ � l W SUS -TOTAL $ 92.19 `N(7rL {',prmiarrJal plane will be subrnNtsd to the flat Counoll Enrlra+n+radal Svcs M Plumbing Fee (from Page 2) $ for W dohmainetion. Eoomw payment will be required when pwmft is Issued. a W Mechanical Fee from Pqge 2 $ aft« Yet Cerardl review no 8AC Is determined, escrow win be refimded in full. Special Conditions/Required Setbacks: Buiiding Approval By: Ty Turnquist (LT) DATE: 07/01/2021 Printed Building Approval By: ❑ License Vei96mttion ❑ Lead Verification - Checked By. yl /a / City APpmvaI By. DATF- PA. ,' Date: Receipt No. BY OL4 CITY OF SPRING PARK PAGE 1 BUILDING PERMIT 4349 Warren Avenue SP-2021-00068 Spring Park, MN 55384 ❑ Handout Given Routed to MNSPECT Piton •952-471-9051 Fax:952-471-9160 ❑ Load Handout Given SITE ADORE :� �` 1 ` M Pilo: I) Was the horn constructed before 19789 (YES u, continue with line 2, NOScontinua without completing EPA �ection) 2) Will the work di rb z8 sq ft of interior painted surfaces or 220 sq ft of exterior painted surfaces? (YES o go line 4. NO o line 3) 3) Are there any win ows being replaced2 (YES ❑, go to line 4, NO o continue without completing EPA Sed 4) Has this home bee Certified Lead Free? (YES ❑, you MUST Attach Certification information, NO o com eta line 5) 5) EPA Contractor Ce ton Number NAT - (applies contractor only) PROPERTY ONMER: Address .. zip- Email: o.+r� . 1..�.. rrrlaii►.� Contact Name Phone �. CONTRACTOR: Address: State: zip: Phone: Fax. Contractor License No: Contact Name: +Pione:k Email. ARCHITECT: Address: State: ZIP- Phone: Fax Email: Con Name; ''' Phone: TYPE OF WORK: ❑ NewConstructi ❑ ck „'t ❑ Pool `ter; t';'- RRe-Roof a.Commercial ❑ Residential ❑ Change of Use ,;: taT g Wag: Porch ORS -Side EST, VALUATION OF WORK ❑ Finish Basement ❑ Fence _ S (}) ❑ Remodel a Fusprx►ir>: a Shed ;square foet: PrYIdfW o Addition q,f iAlarm u WindowlDoor Replacement per ❑ Garage -Attach :. Plumbing -provide detat on Pane 2 # being replaced �• Work: ❑ Access0 tic i"lled Description of "❑ eehanical provrda detaA on Page 2 n Mist Other 7 r- • V ukaa orthle oWileaton by idle W90 property owiw Oft,*WXWtl ' . ee #ra.:Oilrwir's tspreseritativa, fo*M d and suilodees the Zon" Administrator or design" and thw eu➢Y.ng offim d9o" to order upon tfw property to prfam needed h'piotlaM. Eh4y y.4F IPlfl°ut prbr notics. l harvby kror Wdge that I hKa Head this application and stets ihu all hiermathn le true wed rdract to ft bad or my folowtsdga. I tuthatr a9rae that al wwku 11�#rattordW wbh approved pia , spociacau vita tonoons and to abide by Al ort4ioncas ofthe Murllep�jl uld the foie of the StaW of M nnewra regsr*lp actlors taken p6tMuard ilia permit.1 agree to pay all plan tea wan If 1 choose not to ptoaeed with aw wore. Parm h axpM what wwk t not comment sd wkW 180 days from BMA W paanii, do ff asotk b deA olo Boned, or bd r r 'In Inepetted loll 11 . iNotk beyond the scow of this permit, or wait wathort a permit or Irwoc1i n, a .lit be subject to a penalty.Noise OrdinatleA ill, Efisc IVONDAY - DAY Before 7 em. and after 10 p m. kends/Holidays before 7 a.m. and after 8 p.m. SIGNATURE OF AP .: DATE: iPFI!INTE tt+� C� :. This Is the slgnatls ofOwner or Xa Owner's Re esarttative OCCUP. TYff_: .. - CONST. E: CODE: VLDG SPRINKLED Yes 1 No VALUATioN:-'j 17 000.00 Permit es: $ 368.75 WA Change: $ Plan Revie Fee: $ Sewer & Water k-Up: $ State Su arge: $ Sewer & Water Dis nett: $ Site lnspe ion Fee: $ Water ter. $ .E.C. Fee: $ Muni SElWA F : $ Investigation F Other Fee: $ •2016 SAC Escro . Copy Charge ($-25 per .5 x11 page) $ OtheTOTAL Z Uzonso Chock ($5) t d Chock ($5) $ DUET $ O W SUS -TOTAL S 377.25 'NOTE; Commercial plarts will be submitted to the fie ounoll En*omreanhl Sup Plumbin Fee (from Page 2) $ for SAG datermdnation. Eacrow payment will be require when permit is Issued. u w Mechanical Fee from P e 2 � . offer Met Council ravioli no SAC Is datorrntnad, astrow be rahmdrad In fuL sa u. Special Conditions/Required Setbacks: U. 0 Building Approval By: Ty Turnquist (LT) DATE: 07/01/2021 Printed Building Approval By: ❑ License Verification ❑ Lead Verification -Checked By: City Approval By: DATE: Paid: Date: Receipt No. By: Transaction ID: 14512 Transaction Number. Transaction Type: Payment Recipient: Property Owner Notes: Fees —Permit Fee Thank you for your Payment! l CITY OF P RIIC-,s\I V1i%IN11101A City of Spring Park 4349 Warren Avenue SP MN, 55384 Ph: 952-442-7520 $92.19 Date: 12/13/2021 Method: Check: 4240 Address: 4364 WEST ARM ROAD, SP, MN 55384 Reference: Permit Number: SP-2021-00068 Type: BLDG - Misc Repair for BARBARA K WARD Paid 1.00 $92.19 $92.19 Total Amount: $92.19 Page 1 of 1 Printed on: 12/13/2021 HELPING VOU COMPLY WfTO PHONE: 952-442-7520 FAX: 952-442-7521 EMAIL: INFO@MNSPECT.COM RESIDENTIAL ROOFING REPLACEMENT This handout is intended only as a guide. It shall not be considered a complete set of requirements. Materials and installation must comply with the current Minnesota State Building Code and the manufacturers' installation specifications for each product. Residential roofing replacement permits are issued over the counter at the municipality; office. This handout is VALID for single-family homes, duplexes, and townhomes. (Does NOT include condominiums, apartment complexes, and commercial properties.) NOT VALID for repairs, replacement, removal, or installation of any structural members. Each address requires a separate permit. POSTED prior to start of work - VISIBLE from street or driveway - to the inspector Inspections MUST be scheduled during office hours AT LEAST one business day prior to inspection. If a specific date and time is required, additional notice may be needed. Failure to cancel a scheduled inspection may result in a reinspection fee. o Office Hours: Monday - Friday • 8:00 a.m. - 4:30 p.m. o Phone: (952) 442-7520 or (888) 446-1801 In -Progress Inspection: An inspection must be performed prior to the completion of the project unless otherwise approved (see Page 3 for details). Ideally, the inspection should take place when the tear -off is done and the underlayment and ice barrier are applied and not yet fully covered by roof covering. (The taking of photographs showing decking, ice barrier, underlayment, and flashing is always a good idea, but is NOT a substitute for the required inspection.) See notes on Page 2 regarding installing roofing materials over one existing layer. ✓ Your representative must be on site, able to communicate with the inspector, and provide access to the roof (ladder). ✓ You must have all installation instructions on site. ✓ Asphalt shingles must meet ASTM D7158 or ASTM D 3161 and comply with Table R905.2.4.1 of the current MRC for class and minimum wind resistance. Verification must be provided at time of inspection. ✓ Failure to comply with inspection and installation requirements may result in: 1) the requirement to remove materials, 2) penalty fees, and/or 3) a license investigation under Minnesota Statute 326B.84. NOTICE: Construction or work for which a permit is required shall be subject to inspection by the Building Official, and such construction or work shall remain accessible and exposed for inspection purposes until approved. It is the responsibility of the permit applicant to be in attendance on site and provide access to the Building Official for all required inspections. If work is concealed and/or work is not complete at time of inspection, an additional inspection is required and a reinspection fee may apply. Note: The State of Minnesota requires all residential building contractors, remodelers, roofers, plumbers, and electricians to obtain a state license, unless they qualify for a specific exemption. Any person claiming an exemption must provide a copy of a Certificate of Exemption from the Department of Labor & Industry to the Municipality before a permit will be issued. Note: To determine contractor requirements, or to check the licensing status of a contractor, please call the Minnesota Department of Labor & Industry at 651-284-5065 or toll free 1-800-342-5354. Note: For specific code requirements, contact the Building Inspection Department at 952-442-7520 or 888-446-1801 or e-mail: infoCa_mnspect.com. Residential Roofing Replacement Handout Page 1 of 3 Copyright © MNSPECT 2020, Rev. April 2021 lJ When new roof covering is to be installed over one layer of existing covering, an initial inspection prior to covering will need to be completed to verify that only one layer is being covered and compliance with R908.3.1 is being met: R908.3.1 Re-covering versus replacement. New roof coverings shall not be installed without first removing all existing layers of roof coverings where any of the following conditions exist: 1. Where the existing roof or roof covering is water -soaked or has deteriorated to the point that the existing roof or roof covering is not adequate as a base for additional roofing. 2. Where the existing roof covering is wood shake, slate, clay, cement or asbestos -cement tile. 3. Where the existing roof has two or more applications of any type of roof covering. A re -inspection and re -inspection fee will be required if the original roofing is determined to be inadequate. The following is a guideline to assist in compliance with the requirements of the MN State Building Code. ❑ The home address must be visible from the street. ❑ Identify the roof pitch(es) to determine which approved roof covering(s) can be installed. Roof Coverinq Pitch Requirements Roof Coverinq Pitch Requirements Asphalt Shingles T' rise per 12" run or greater Metal Roof Panels ''/2' rise per 12" run or greater (_ * *) (lapped, with sealant) Clay/Concrete Tile 2'/2' rise per 12" run or greater Metal Roof Panels 'W rise per 12" run or greater (*) (standing seam) Wood 3" rise per 12" run or greater Modified Bitumen Roofing "W rise per 12" run or greater Shingles/Shakes (A*) Metal Shingles 3" rise per 12" run or greater Thermoset Single -ply Roofing ''/<" rise per 12" run or greater ('I- * ) Metal Roof Panels 3" rise per 12" run or greater Thermoplastic Single -ply 'W rise per 12" run or greater (lapped, no sealant) Roofing Slate Shingles 4" rise per 12" run or greater Liquid -applied Coatings 'W rise per 12" run or greater A- Mineral -surfaced Roll 1" rise per 12" run or greater Sprayed Polyurethane Foam 'W rise per 12" run or greater Roofing _1 * Roofing ❑ Make sure the roof decking is in good condition and there are no gaps that exceed the manufacturer's installation instructions for the roof covering used. Roof sheathing shall be checked prior to re -roofing and repaired or replaced if rotted or unsound. Replacement sheathing shall conform to the requirements of the Building Code and the manufacturer of the product. ❑ Obtain a Building Permit if any structural members need to repaired, replaced, and/or added. ❑ .4 Install the required ice barrier starting at the eaves to a point no less than 24" inside the interior of the exterior wall (measured horizontally). (Exception: detached structures that are not heated.) ❑ Make sure all flashing is constructed of a minimum 26-gauge, corrosion -resistant sheet metal. ❑ Install the front wall, vertical sidewall, soil stack, vent pipe, and/or chimney flashing in accordance with the manufacturer's printed instructions. Apply counter flashing in a shingle -like fashion. ❑ Install valley linings and flashing. ❑ A cricket or saddle is required on all chimneys or penetrations that are more than 30" wide (measured parallel to ridge). See Figure R1003.20 and Table R1003.20 — current MN State Residential Code. ❑ * Install the required underlayment materials, ensuring the underlayment materials extend to the edges of the roof deck. *(For Asphalt Shingles - Roofs with pitches of 2:12 up to, but not including, 4:12 have double underlayment requirements. First, apply a 19" strip along the eave, and then 36" strips lapped a minimum of 19". End laps shall be 4" and offset by 6'. Please call if you need additional information.) ❑ Ensure all roof covering materials are installed in accordance with the manufacturers' installation instructions. ❑ Ensure all venting terminations extend through the roof deck and are properly flashed. ❑ Ensure the minimum attic cross -ventilation is provided. How to calculate the minimum: 1. When soffit/eave venting is provided, 1 sq. ft. minimum of net free ventilation area shall be provided for every 300 sq. ft. of attic area (40%-50% of the net required ventilation opening must be located in the upper portion of the roof, no more than 3' below the ridge). The remaining ventilation must be located in the eave/soffit. 2. When less than 50% of the required ventilation is provided in the eave/soffit, 1 sq. ft. minimum of net free ventilation area shall be provided for every 150 sq. ft. of attic area. ❑ All removed and excess roofing materials must be disposed of at an MPCA-approved landfill. Residential Roofing Replacement Handout Page 2 of 3 Copyright© MNSPECT 2020, Rev. April 2021 44. INSPECTION PROCEDURES FOR REROOF PROJECTS APPLIES FOR THE INSTALLATION OF ASPHALT SHINGLES ONLY The building code requires an inspection to close all permits. The appropriate time to verify compliance and discuss the project is while the work is "in progress." As a result, we require the contractor to call us at (952) 442-7520 at least one day prior to starting the work to schedule a half -way inspection (while the work is underway). If, and only if, we are unable to provide an inspector while the project is underway, we will authorize you to take photos and provide them at the final inspection, which will require you to provide the photos at the job site. If the inspector who visits the worksite determines that the supplied pictures are not conclusive, you will be required to meet our inspector on -site and to provide access to the roof. Should this be required, a reinspection fee will apply. At the time of the inspection, you must provide the following photos: NOTE: Photos shall identify that the roof is of the house being worked on (i.e. photos should include identifying features such as the yard, driveway, house siding, etc.). ✓ Decking with nothing on it — all sides/planes of the roof ✓ Ice/water guard — photos taken BEFORE underlayment is added to roof ✓ Underlayment — photos taken after installation: • All sides/planes of the roof • Underlayment shall extend to roof edges ✓ Flashing — all required flashing: • step flashing, • dormer flashing, • All other required flashing Benefits of an in -progress inspection: • If there is an issue with the work "under" the shingles, it can hopefully be caught prior to covering — saving time and money. • Pictures are often inconclusive. • The inspector can communicate directly with the contractor while on site, avoiding the possibility that correction requirements will not be passed on to the contractor. • If the contractor has a wide range of service it can be inconvenient to return to the site to make any required corrections. An in -progress inspection allows corrections to be made while the contractor is still on site. • The inspector and the contractor can discuss issues and concerns to ensure that work being done is compliant with the code. The Inspector's job is to verify a code compliant installation. In -progress inspections are the best way to do this! Residential Roofing Replacement Handout Page 3 of 3 Copyright© MNSPECT 2020, Rev. April 2021 INSPECTION PROCEDURES FOR REROOF PROJECTS APPLIES FOR THE INSTALLATION OF ASPHALT SHINGLES ONLY The building code requires an inspection to close all permits. The appropriate time to verify compliance and discuss the project is while the work is "in progress." As a result, we require the contractor to call us at (952) 442-7520 at least one day prior to starting the work to schedule a half -way inspection (while the work is underway). If, and only if, we are unable to provide an inspector while the project is underway, we will authorize you to take photos and provide them at the final inspection, which will require you to provide the photos at the job site. If the inspector who visits the worksite determines that the supplied pictures are not conclusive, you will be required to meet our inspector on -site and to provide access to the roof. Should this be required, a reinspection fee will apply. At the time of the inspection, you must provide the following photos: ✓ Photos shall identify the roof is of the house being worked on. (i.e. photos may include the yard, driveway, house siding, etc.). ✓ Decking with nothing on it — all sides/planes of the roof. ✓ ice/Water Guard — photos taken BEFORE underlayment is added to roof ✓ Underlayment - photos taken after installed • All sides/planes of house • Underlayment shall extend to roof edges ✓ Flashing —all required flashing: • step flashing, • dormer flashing, • All other required flashing Benefits of an In -Progress inspection: • If there is an issue with the work "under" the shingles, it can hopefully get caught prior to covering — saving time and money. • Pictures are often inconclusive. • Communication challenges — the owner has to contact the contractor to notify them of required corrections. • Some contractors leave the area when the storm damage repairs are done, making it difficult for the contractor to come back and make the required corrections. • The inspector and the contractor can discuss issues and concerns to ensure that work being done is compliant. The Inspector's job is to verify a code compliant installation. In -progress inspections are the best way to do this! Phone: 952-442-7520 jjj M N S P E G T,-Lc Fax: 952-442-7521 HELPING YOU t i COMPLYit7t Email: info@mnspect.com RESIDENTIAL SIDING REPLACEMENT ➢ This handout is intended only as a guide. It shall not be considered a complete set of requirements. ➢ Materials and installation must comply with the current Minnesota State Building Code and the manufacturers' installation specifications for each product. ➢ Residential siding replacement permits are issued over the counter at the municipality office. ➢ This handout is VALID for single-family homes, duplexes, and townhomes. (Does NOT include condominiums, apartment complexes, and commercial properties.) ➢ NOT VALID for repairs, replacement, removal, or installation of any sheathing and/or structural members. ➢ Each address requires a separate permit. ➢ If the home was constructed prior to 1978 and 20 s.f. or more of painted exterior materials will be disturbed, the contractor must be EPA "Lead Safe Certified" or qualify for an exemption. ➢ Brick, stucco, stone, or EIFS siding installation or removal requires a building permit. EIFS also requires special inspections by a third -party testing agency POSTED prior to start of work - VISIBLE from street or driveway - ACCESSIBLE to the inspector Inspections MUST be scheduled during office hours AT LEAST one business day prior to inspection. If a specific date and time is required, additional notice may be needed. Failure to cancel a scheduled inspection may result in a reinspection fee. o Office Hours: Monday - Friday • 8:00 a.m. - 4:30 p.m. o Phone: (952) 442-7520 or (888) 446-1801 In -Progress Inspection: An inspection must be performed prior to the completion of the project unless otherwise approved. Ideally, the inspection should take place after the existing siding is removed, all windows are taped, the house wrap or felt paper installed and new siding started but not fully covering the house wrap. (Taking photographs documenting sheathing, water resistive barrier, sealing of penetrations and openings, and flashing is always a good idea, but is NOT a substitute for the required inspection.) ✓ Your representative must be on site and able to communicate with the inspector. ✓ You must have all installation instructions on site. ✓ Failure to comply with inspection and installation requirements may result in: 1) the requirement to remove materials, 2) penalty fees, and/or 3) a license investigation under Minnesota Statute 32613.84. NOTICE: Construction or work for which a permit is required shall be subject to inspection by the Building Official, and such construction or work shall remain accessible and exposed for inspection purposes until approved. It is the responsibility of the permit applicant to be in attendance on site and provide access to the Building Official for all required inspections. If work is concealed and/or work is not complete at time of inspection, an additional inspection is required and a reinspection fee may apply. Note: The State of Minnesota requires all residential building contractors, remodelers, roofers, plumbers, and electricians to obtain a state license, unless they qualify for a specific exemption. Any person claiming an exemption must provide a copy of a Certificate of Exemption from the Department of Labor & Industry to the Municipality before a permit will be issued. Note: To determine contractor requirements, or to check the licensing status of a contractor, please call the Minnesota Department of Labor & Industry at 651-284-5065 or toll free 1-800-342-5354. Note: For specific code requirements, contact the Building Inspection Department at 952-442-7520 or 888446-1801 or e-mail: info CDmnspect.com. Residential Siding Replacement Handout Page 1 of 6 Copyright @ MNSPECT 2020, Rev. April 2020 TABLE R703.3(1) WEATHER —RESISTANT SIDING ATTACHMENT AND MINIMUM THICKNESS TABLE VOS-W1) SIDING MINIMUM ATTACHMENT AND MINIMUM TWKNE% TYPE OF SUPPORTS FOR THE SIDING IRATERIALAND FASTENERS HOHMNAL Y6end dr ,rood SIDING MATERIAL THICKNESS �TMENT strteewrei Fiberboard Gypsum Foam pia2dc Olraet Nwnbaror jGncbas} Pow shaaWrtg sfiaethlny sheathing Spacing of thesuft into stud into stud wswtls into stud, fasteners trite $dice Anci ww veneer: wa, concrete. rnasonry or skate 2 Satfiol R703 $ Section R703 8 (sea Seaton R703.8) Adhered vot*or; eoncretb, SSone or itlaSO O Sockirl R703, 12 SeCSon R70312 (see Section R703.12) 4d common Ir Panel Potel Siding is" $I's $action R703.101 6d oo+v+wh 66 common 6d c omnOn W corr~nvn 111 i % e49 7r Section R703.10 1 (2. x 0. t13') Y x 0,113' x 0.113' ' fiber 0.099•) utter. step_ cexnr1r11 {!siding ad�� c Lap swing (see 3tg6 Section R703,10.2 Od cornrnon 6d summon 6d conmort 6d COnxnon t2` 0.113`I Node { Sacttor1R703:iQe2) (Y=O.tss') (2"=0.1TV) (2'=0.1131) (2'=0.113') j artsgepe 10"Ing nil, — _ 0,120' Trail fl W n0 0 124 ,toil 0.120 real 0 IiW rt* 6' panel HardXWO pill* �11e — {cherrk)vAh (otank)with tshankl wM (shank)with is it)with edges!?` 3id� 0225• head 0 099' nail 0.225' head 0094 n" 0225' head 0.099' rat 0.225' head 0.099' nai 0.225' head 0 039' nsi inter sup " Same as stud Hardtxmrd cep erd,ng 711e Nola ra Iahank 1 vAh (&honk) wft (%hank i with (,thank) wiat (■hank) with SWiftg 2 ,!see Section R703.5) 1)240' hood 024OF head 0.240' hW 0.240' head 0.240' head Per boar" Siding nail' 02 x 012V Not allowed Serne as Illonzoritat 0.0I9t Lap Siding nail f ttZ x 0.120" S" red 2` x 0.120` Siding nag 2'- 0-120' Wit -A akjrrunume 0.024 Lap Siding nod t ire' = 0 12T Siding na4 2' = 0 120 Siding rrsrl 2" = 4.120' SWvV nail" 111J' = 0.12T Not allowed ow tt With rowel a 0.019 Lap Siding NO 1rf; x 0-12(t' S*V r� 2`'17' - 0 120' Siding mad 2 ,` 0 12n' , S>o nq rs i" ' .,' 0 icy' SxTc rya.' 11,' . 0 n 20 spacing 16 mows on c amer w I O t20 nag 0.120 nail 0.120 nail Specified by 0.035 I�Yf (sh-41c)vwth (shonk)with (shanki with 0 14 nail (shanky with Not nwnutatturar I' Insulated vmyt mdhV Lap a 0.313 head a 0.313 nead a 0,113 head mslructiDns. aiding a 0 f3 0 313heed allowed or Mgage at 16-gage as Mgage teed ration laynrr On[y) Crown` crown crotwh Seaion R703 112 of~ section of "A Code { # -11a — 6d box nail ,t Od box at Od box nail Od bolt nail Not (r x 0.099') (2` x 00W) (2' x 0.0991 (2' = 0.09" alowed — 6d box net ed box no 6d bon nail 6d box nail 6d box nail 6' one) !Partkbboard panels + (2' k 0,0"') 42' -0 0) (2" = 0,009`1 (2" =0.0Wi (2` • 0.0Wf edges 12' Ltd box r 8d boat nail acne+, sup 6d tiox net' i2+ ; i2r1{ x 6d tiox nail fay Mx nail 12" = 0.099") 12' • 0.0W)i t2` • 0-098 ► O.t13') O.ti3"! Residential Siding Replacement Handout Page 3 of 6 Copyright © MNSPECT 2020, Rev. April 2020 by ha manuraaurer PeilypropyAeAe WineWineNot Lap 3aeGait 793.14.1 See6aet'7g3.td:1 $Detort743.i4.1 Sateen 703.13 4 Not "SIW WS, ePpAca6ie errD'lred tell i4p ]ft sx other swiom d !�S OGtSe Siding nail Siang nail set3i; trail Siding nail Nor san"'aas Stoat, 29g4. Lap o.1ta') o.11a�r 0.113°) o_s4a'r W.I W@d alud aGac q Slagle-13/4' Staple-21 SUpla-VI.0 Staple-014* 0.110'narl 0, 120, red 0.12V nrA toich"P1 (Shenk) With (shank) Will, 0120' and 40row or A3 a R317 head A 0.313' head A 9317 ihoad ( Not :by AA35 Lap a I asap or 16v" Of 16. gap � V* (eaa Sect'w+ R709;14) 0 313t ea a 9 313 head ealowed staple W6h vap wvt staple ae4h sattion R703.11.2 mawme w -r1-10sr:•Inch sg talrr fra star insinudlomor pOWlt inch ctown, inch Crown test report Weed rustic, t`a r+� Lap race nmfeV drop 9d box Or up to 6' _ 6d box or 6d tKki or ed bon or ed box or siring nail Widiha, 1 tied Nr j r W009 siding � { iP�P i siding nail - aadmg nail wing nail aiff;ng nAi1 ti'�� :' • oat bearing. ' (see section R703.5) aysta4e Lap 2' 0.099'i 2 0.099 2 = 9 449 a' "V14 rrt4 t)eVel ^2 and QVW. 2 nails Bolt Op 4r,y Lap PW bearing 21t7. = 2r2.. 2tT ■ g Panel vvwd watQaral panel ANSVAPA PRP-210 3 s M- ra Now 2' K 0.099 0.113' 0.143' 0.113' 2' K 0 O idgas 12` aiding (adanor grade) aiding nail a+dr g nail (a"Seaton R703 5) 02 (W iitln9 oat O&V 061 Net sap Wood stivcturei panel ,is 1 �2 Note a j 2` . 0.099` 2trz.. 0,113' 2�1�.3 2irg � 0,415' 0,113, 2` a OA61g s atonm lap aiding is" Sac mw R703 5) Nots 9 siding nail sid V Imo bonom edg s siditlg nail sidkv ft" sift AAil a. Aluminum nails shall be used to attach aluminum siding. b. Aluminum (0.019") shall be unbacked only where the maximum panel width is 10" and the maximum flat areas is 8". The tolerance for aluminum siding shall be +0.002" of the nominal dimensions. c. Shall be of approved type d. Where used to resist shear forces, the spacing must be 4" at the panel edges and 8" on interior supports. e. Vertical end joints shall occur at studs and shall be covered with a joint cover or shall be caulked. f. Face nailing: one 6d common nail through the overlapping planks at each stud. Concealed nailing: one 11gague 1 1/2" long galvanized roofing nail through the top edge of each plank at each stud in accordance with the manufacturer's installation instructions. g. Vertical joints, if staggered, shall be permitted to be away from the studs if applied over woods structural panel sheathing. h. Minimum fastener length must be sufficient to penetrate sheathing other nailable substrate and framing a total of minimum 1 1/4" or in accordance with the manufacturer's installation instructions. i. Where specified by the manufacturer's instructions and supported by a test report, fasteners are permited to penetrate into or fully through nailable sheathing or other nailable substrate of minimum thickness specified by the instructions or test report, without penetrating framing. j. Insulated vinyl siding shall comply with ASTM D7793 k. Polypropylene siding shall comply with ASTM D7254 I. Cladding attachment over foam sheathing shall comply with the additional requirement and limitations of sections R703.15, R703.16 and R703.1 Residential Siding Replacement Handout Page 4 of 6 Copyright © MNSPECT 2020, Rev. April 2020 Table R703.15.1 Cladding Minimum Fastening Requirements for Direct Attachment Over Foam Plastic Sheathing to Support Cladding Weight MAXIMUM THICKNESS OF FOAM SHEATHING` CLADDING CLADDING CLADDING (inches) ,FASTENER FASTENER FA51!aNhK1 1 16" o.c. Fastener Horizontal 24" o.c. Fastener Horizontal THROUGH TYPE AND I VERTICAL Spacing Spacing FOAM MINIMUM SPACING SHEATHING SIZEb (inches) Cladding Weight: Cladding Weight: 1- 3 psf 11 psf 18 psf 25 psf 3 psf 11 psf 18 psf 25 psf 0-113" 6 2,00 1.45 0.75 DR 2.00 0.85 OR DR diameter 8 2,00 1.00 DR DR 2,00 0.55 OR DR nail 12 2.00 0-55 DR DR 1.85 DR DR DR 0. 120" 6 3.00 1.70 0.90 0.55 3,00 1,05 0150 DR - -------- - - Wood diameter 8 3.00 1.20 0.60 DR 3,00 0.70 DR t DR framing nail 12 3.00 0.70 DR DR 2.15 DR DR DR (minimum 6 4.00 2 15 1.20 0-75 4.00 1.35 0.70 DR 1114-inch 0.131" penetration) diameter 8 4,00 1.55 0.80 DR 4.00 0,90 DR DR nail 12 4,00 f 0.90 DR j DR 11 2.70 0.50 DR DR 0, 162" 6 4,00 3-55 2.05 1-40 4.00 2.25 1.25 0-80 diameter 8 4.00 2-55 1,45 j 0.95 4.00 1.60 0.85 0.50 nail 12 i 4-00 1.60 0.85 0.50 4.00 0.95 DR DR L For Sl; I Inch - 25.E mm. I pound per square foot = 0.0479 kPa, I pound per square inch - 6.895 kPa' DR = Design Required, o.c. = On Center. a. Wood framing shall be Spruce-ptne-fir or any wood species with a spect(tc gravity of 0,42 or greaten in accordance with AWC NOS. b. Nail fasteners shall comply with ASTM F1 667, except nail length shall be permitted to exceed ASTM F 1667 standard lengths. c. Foam sheathing shall have a rninimurn compressive strength of 15 psi in accordance with ASTM C578 or ASTM C1 289. Residential Siding Replacement Handout Page 5 of 6 Copyright @ VINSPECT 2020, Rev. April 2020 Table R703.15.2 Furring Minimum Fastening Requirements for Application Over Foam Plastic Sheathing Furring Material Framing Member Fastener Type and Minimum Size Penetration Into Wall Framing Fastener Spacing in Furring (Inches) 16" O.0 Furring e 24" O.0 Furring e Material Weight Material Weight 3 11 18 25 3 11 18 25 Minimum 1x Wood Furring c Minimum 2X wood Stud 0.131" Diameter Nail 1 1/4 8 4.00 2.45 1.45 0.95 4.00 1.60 0.85 DR 12 4.00 1.60 0.85 DR 4.00 0.95 DR DR 16 4.00 1.10 DR DR 3.05 0.60 DR DR 0.162" Diameter Nail 11/4 8 4.00 4.00 2.45 1.60 4.00 2.75 1.45 0.85 12 4.00 2.75 1.45 0.85 4.00 1.65 0.75 DR 16 4.00 1.90 0.95 DR 4.00 1.05 DR DR No 10 Wood Screw 1 12 4.00 2.30 1.20 0.70 4.00 1.40 0.60 DR 16 4.00 1.65 0.75 DR 4.00 0.90 DR DR 24 4.00 0.90 DR DR 2.85 DR DR DR 1/4" Lag Screw 11/2 12 4.00 2.65 1.50 0.90 4.00 1.65 0.80 DR 16 4.00 1.95 0.95 0.50 4.00 1.10 DR DR 24 4.00 1.10 DR DR 3.25 0.50 DR DR a. Wood framing and furring shall be SPF or any wood species with a specific gravity of 0.42 or greater in accordance with AWC NDS. b. Nail fasteners shall comply with ASTM F1667, except nail length shall be permitted to exceed ASTM F1667 standard lengths c. Where the required cladding fastener penetration into wood material exceeds 3/4" and is not more than 1 1/2", a minimum 2x wood furring or an approved design shall be used. d. Foam sheathing shall have a minimum compressive strength of 15psi in accordance with ASTM C578 or ASTM C1289 e. Furring shall be spaced not more than 24" o.c, in a vertical or horizontal orientation. In a vertical orientation, furring shall be located over wall studs and attached with the required fastener spacing. In a horizontal orientation, the indicated 8" and 12" fastener spacing in furring shall be achieved by use of two fasteners into studs at 16" and 24" o.c, respectively. Residential Siding Replacement Handout Page 6 of 6 Copyright © MNSPECT 2020, Rev. April 2020 RECEIVED DEC 10 2021 From: City Clerk _'vclerk@ci.spring-park.mn us Subject: RE: Building Permits for 4364 & 4368 West Arm Road Date: December 2, 2021 at 1:34 PM To: Barb Ward bkward55@gmail.com, Andrew Ward ward. andrew@live.com Hello Barb and Andrew; I just heard back from MNSPECT on your permits. Since you only did miscellaneous repairs v. the full siding and roof tear off, they agreed to reduce the cost to the following amounts: SP-2021-00067: $118.81 SP-2021-00068: $ 92.19 You can drop off a check at the address below or pay using our online payment method at: www.paymentservicenetwork.com. Once we receive payment we will send you the permits for your files and close them out on our side. Glad they were able to work something out with you! Thanks!! ..r SPRING PARK On "kr Mu1nr en0 Jamie Hoffman City Clerk City of Spring Park 4349 Warren Ave Spring Park, MN 55384 952.471.9051 cityclerk@ci.spring=park.mn.us www.ci.spring=park.mn.us City Hall Hours are Monday - Friday 8:00 a.m. - 4:30 p.m. From: Barb Ward <bkward55@gmail.com> Sent: Thursday, November 11, 2021 10:17 PM To: City Clerk <cityclerk@ci.spring-park.mn.us> Cc: Andrew Ward <ward.and rew@Iive.com> Subject: Re: Building Permits for 4364 & 4368 West Arm Road Importance: High Hi Jamie, I went on line to the link you provided but was unable to find the building permits or the bills. All I saw were the water bills, which were all paid up. -r7..... I,.u._.. aL--4 ...-- ---.L 4— .....- ...,. — 4L--4 4L-- L...:1-1:.. - ---.,...:a ....... .......,.....:-I,-A . — 1A►.... JA