Permits - Permit# SP-2022-00011 - 3701 Sunset Drive - 2/8/2022City of Spring Park Permit 1 CITY Of _ �S P R I IN M1NP41SOIfA To Schedule an Inspection Call: 952-442-7520 Details Permit Number: SP-2022-00011 Issue Date: 2/8/2022 Zoning Type: COMMERCIAL Use Type: S1 24 HOUR NOTICE REQUIRED FOR ALL INSPECTIONS ♦ MON-FRI: 8AM-4:30PM ♦ NO HOLIDAYS Site Address: 3701 SUNSET DRIVE, SP, MN 55384 Description: Ceiling hung heater and associated gas lines Permit Granted To: MYSERVICEPRO 612 PLUMBER Homeowner's Name: MSP HOLDINGS LLC Phone Number: Parcel #: 1711723310045 Fees (4) Permit Type: MECH - General (Comm) Permit Exp: 8/6/2022 Valuation: $1,000.00 Receipt Product Sale Date _*uantity Date Paid Status Prnt Info Amount 14882 Special Investigation Fee 2/7/2022 75.00 2/8/2022 Paid Check: 3924 $75.00 14882 State Surcharge 2/7/2022 1.00 2/8/2022 Paid Check: 3924 $0.50 14882 Permit Fee - PLG, MECH Comm 2/7/2022 1.00 2/8/2022 Paid Check: 3924 $75.00 14882 Plan Review Fee 2/7/2022 1.00 2/8/2022 Paid Check: 3924 $48.75 Total: $199.25 Notes • This permit is issued in accordance with and subject to all provisions of Ordinances and policies governing building and zoning in City of Spring Park. • Permit Holder/Contractor/Owners Agent is responsible to call for the inspections! • Permit Packet, including approved plan, and this inspection record must be posted in an accessible location before calling for inspection. Maintain this inspection record until work is complete. • No deviations from the approved plans are allowed without prior consent from the building inspections department. • To Owner, Occupant, or Contractor: It is ILLEGAL TO OCCUPY this area/building until all required final inspections have been made, approved, signed, and certificate of occupancy issued! Scott Qualle, Building Official City of Spring Park +4349 Warren Avenue ♦ 55384 Copyright ©2022 INSPECTION RECORD 2020 MN State Building Code City of Spring Park Permit Number: SP-2022-00011 Issue Date: 2/8/2022 SITE ADDRESS: 3701 SUNSET DRIVE, SP, MN 55384 Description: PERMIT TYPE: MECH - General (Comm) Ceiling hung heater and associated gas lines ZONE/USE TYPE: COMMERCIAL S1 APPLICANT: MSP HOLDINGS LLC OWNER: MSP HOLDINGS LLC No inspection will be performed, and a re -inspection fee will be charged, if this "Inspection Record", the "City of Spring Park Permit", and, when applicable, the approved plans are not available to the inspector. This permit expires if construction activity does not commence within 180 days from obtaining this permit; when construction activity has been suspended or abandoned for at least 180 days; or the work has not been inspected within 180 days from the last documented activity. IF SEPARATE PERMITS ARE REQUIRED, REFER TO THE "SEPARATE PERMITS REQUIRED FOR:" STAMP ON YOUR APPROVED PLANS/CONSTRUCTION DOCUMENTS TO IDENTIFY WHAT SEPARATE PERMITS ARE REQUIRED. ALL REQUIRED ROUGH -IN INSPECTIONS, NOTED ON SEPARATE PERMITS, MUST BE COMPLETED PRIOR TO SCHEDULING A FRAMING INSPECTION. ALL REQUIRED FINAL INSPECTIONS, NOTED ON SEPARATE PERMITS, MUST BE COMPLETED PRIOR TO SCHEDULING A BUILDING FINAL INSPECTION. DO NOT COVER ITEMS TO BE INSPECTED. Permit Card (6) Mechanical Rough -In Required Gas Line Air Test Required Gas Line Installation & Air Test Required Balance Report(s) Required Startup Report(s) Required Mechanical Final Required MUST CALL TO SCHEDULE NO LATER THAN THE BUSINESS DAY PRIOR TO THE INSPECTION DAY: 8:00 A.M. TO 4:30 P.M. MONDAY THRU FRIDAY. PHONE NUMBER TO CALL: 952-442-7520 When a Certificate of Occupancy is needed, return this card and the approved final inspection notice to the City of Spring Park office. CITY OF SPRING PARK PAGE 1 BUILDING PERMIT 4349 Warren Avenue SP-2022-00011 Spring Park, MN 55384 ❑ Handout Given Phone: 952-471-9051 Fax: 952.471-9160 ❑ Lead Handout Given Routed to CT SITE ADpRES5:10���,� PD•il ' �` 1) Was file holf,e c:onstructea before 1978? (YES a, continue with line 2, NO o continue without completing EPA Section) 21 Will the work disturb a6 sq ft of interior painted surfaces or 220 sq ft of exterior painted surfaces? (YES o go to line 4. NO u line 3) 3) Are there any windows being replaced? (YES o, go to line 4, NO o continue without completing EPA Section) 4) Has this home been Certified Lead Free? (YES u, you MUST Attach Certification Information, NO o complete line 5) EPA Contracfor Certification Number. HAT - (applies to contractoronly) PROPERTY OVYNER: e , •• t n f^ Address: 1-b ^ ICA Vj1> t (O !SS7 _ State: � Zip: Email: M) f'' 1 ,%} r 6..E � Contact Name: r k- d Zr' Phone:(atl-aal Mo6. CONTRACTOP_ S 4 w ddress: Ci : r o State Zip, Phone: Fax: -"" Contractor License No: e L_ 0 Contact Name: C phone.., a Emaa: 42 pi ILjON,- ARCHITECT Address: -� CAW State: Zip: Phone: Fax: Email- Contact Name° Phone: TYPE OF WORK: _ New Construction neck ::t Re -Roof t"C,lommercial c Residential , Change of Use _ Finish Sasernent Pool a Re-!;ftfe Retaining Wall a __ EST. JA1�IO�N QF WORK 1 Remodel Porch o Shed _ Square feet: LjAd;iition Jemoidion ❑ Window/Door Replacement n Garage-Attached'Detach = Plurfbing4-ovide detail on Pape 2 # being replaced Detailed Description of Work: jj&%essory Structure 'MeChanlCal-orovfde dotal on Page 2 ❑ Mi WOther In ad ;n),6.�0L 3 kft.4i tibn/Ture of this applkalbn by the Jogal preperb amw orre ikWOW OpMeCtpr. Rothe OaelerR IepraRldaM, p regtaed ana aVlgrlra tlrs Ot and the eukbnp omm der daMille er d@W" to enter upon the Pm"dY to Psrksst eudW tnpeelprr Entry �y be allrou prbr nolce. I hereby aekroeAedpo that I have � WWAVoll m hal t and etoogd to fM bat of rq knowledge. I kROw tent 11rat d t**Perbmwd will be In Wcardwm wild apprw d plans, spedtictllars and condllcra W41o11 by odaww:w of" Mumkpaey end few Jove of ihs State of Mlnramk ragawAng adbra telven pwauent tat" pe mlt. I waste pay an plan roslaw rase am R i choose, hot ko 1, - , wNh 110 work. PRIMA expires Mon wwk r, not cw nercW Mena 190 days f M dab of pone or I wok a uWandW, abaftx a not bepecpd for 180 days. Work beyand the Retails of ft permit er wak wVW a pwmk or Yupeom, na be snood W a Pe,rry. _ Noke Ordinancoht Effaft MONDAY - FRJDAY t3efore 7 am. and after to pm. Weekenda/HoNdays before 7 a.m. and after 8 p.m. In SIGNATURE OF APPLICA : DATE: ' .� /RNTED NAME: Aa �,(/' Thee k cilia signature oZ:7d►Owner or o Owner's R of mutative OCCUP. TYPE: CONST. TYPE: CODE 2020 FQQ 113LOGRIPAINKLED Yes / No VALUATION. $ 1,000.00 _ Permit Fee: $ 75.00 WAC Charge: S Plan Review Fee: $ 49 75 Sewer& Water Hook -Up: $ State Surcharge: $ .50 Sewer 8 Water Disconnect: S Site Inspection Fee: S Water Meter. $ S.E.C. Fee: $ Muni SE/WA Fee: $ Investigation Fee / Other Fee: $ 75.00 SAC Escrow. S2 4A5 Copy Charge ($.25 per 8.5 x11 page) $ Oti1en $ z0 License Check (S5) / Lead Check ($5) $ TOTAL DUE: $ w SUB -TOTAL $ 199.25 Plumbing Fee (from Page 2) $ ceegmsromi plans wlh be oubenMed to tM Mot Council Fsvlr nm I Svcs Mechanical Fee m 2 $ for SAC date n inallon. Eacraw paymard will be required when permit in Jostled. If V EW MCouncil alter at Cocil ►Maw no SAC Is determined, snow will b. rohrnded In hd4 LL Special Conditions/Required Sat ivida: O Building Approval By. DATE: 02/07/22 Printed Building Approval By. r don Holmes ❑ License Verification O Lead Verification - Ch4lecked By: City Approval By DATE: Paid: Date: '�; Qa., Rao WNo. J ey. -�� - Read all attached materials. Everyone performing work to which the code is applicable shall comply with the code. Electrical The field copy of these plans must be kept on -site and made available to inspector during all inspections. To schedule inspections call (952) 442-7520 t Please have the permit number t and street address ready at the time of the call. v_yte_1At4__,Azss! e -� All electrical must be approved by local Electrical Inspector. For electrical permit inquiries please contact the City of Spring Park Electrical Inspector. Dave Hucky (952) 442-7520 W All Plan Revisions All construction shall comply with the approved Ip4 Plan revisions will not be reviewed in the field without prior approval from the Building Official. Submit all plan revisions to the Department of Building Safety for review, prior to their construction. j l�OOL6f' Separate Permits Required For: ii Electrical Mechanical Plumbing Fireplace Demolition Fire Suppression System Septic N444 44,11V5 U►1 S7 f cf ta s too, hxt ,, N. Manufacturer's Installation Instructions Shall Be Available To The Field Inspector At Time Of Inspection. Ventilation for this space shall comply with MMC Table 403.3.1.1 o' Heater is a Modine Hot Dawg f` HD75as0111fban 75,000/61500 BTU Heat load is 32,000 BTUs Gas piping is 1/2" soft copper Meter pressure is 2 PSI Developed gas run is 55' Reviewed for Code Compliance This review is limited to the submitted scope of work, is based upon the supposition that the plan $ accurately depicts the intended construction and end -use, that the necessary legal authority has been obtained to construct the project and work is subject to code compliance and field inspection during construction. By:'Sraarlon�L(o(mes' Type of Construction: Date: 2/7/2022 Occupancy Classification: S-1 Permit #: 2022-00011 Code Edition: 2020 MN Mechanical/ Fuel Gas Code S INUJtl�"`J �i�s9 �4c.a}� FAN -Fool 1}ovlde ccessib), 1 I' Sjo e a4 n Pr,Qy'JshaklAG�aSS16)2 Self e-k boo, s$ sY LOU 5F TDr�I D1 a9r, Ltiy 7 Y ,}�• y p k --L4 2 yP x ELC-CTF,!:-'^.L rN ty! E C,k4141CAL � n ri ^:•%: PP ESSION SYSI %l IUi_I� aT RI1.(;H04 H" SOD KITCHEN NLvb FIRE SUPARE 1 C11 o' lL REVIEWED SUBJECT TO OOMPLIANOR . f �',I'TH CQrIES AfI'Vt���j MILE) 54 F� a� '� UR IrIC� � - �`\pf t CONSIRU, y I-r- Spring Park SPRING PARK Project Name: 220201 - 3701 SUNSET DRIVE - Approval Status HEATER Pemit Number: SP-2022-00011 Job # Date: 02/07/2022 Job Name: Applicant Name: MYSERVICEPRO 612 PLUMBER Submittal # Applicant Phone: (612) 221-2906 Submittal Name: Applicant Email: myservicepro@hotmail.com Construction Type: Jobsite: 3701 SUNSET DRIVE Code: Trades Reviewed: Mechanical Approved with Comments SP22-0005 220201 - 3701 SUNSET DRIVE - HEATER MECHANICAL PLAN #2 The plans and specifications, for the project named above, have been reviewed for substantial compliance with the current Minnesota State Building Code. This review is limited to the submitted scope of work; is based upon the supposition that the data on which the design is based are correct and that the necessary legal authority has been obtained to construct the project. Although every attempt has been made to identify code issues or concerns for proper and necessary change, the project designer(s), the building contractor(s) and the property owner(s) are ultimately responsible for providing complete code compliance and maintaining minimum construction standards for the safeguarding of life or limb, health, public welfare and property while constructing this project. The following items are related to the submitted plans/scope of work and are found to be either noncompliant with the Minnesota State Building Code or additional information is needed. Please respond by letter of verification and/or revised plans or addenda identifying corrections have been made. All comments shall be resolved before the building permit can be issued. If you have any questions or concerns regarding this plan review, please contact me via telephone at (952) 442-7520 or email at codereview@mnspect.com. Sincerely, Brandon Holmes (952) 442-7520 bholmes@mnspect.com .r- Spring Park SPRING PARK Plan Specific Items: Mechanical 1. The output capacity of heating and cooling equipment shall be not greater than that of the smallest available equipment size that exceeds the loads calculated in accordance with Section C403.1.1. (MCEC 403.3) Ensure that the 61,500 BTU output is smallest available size for this model that exceeds the 32,000 BTU heat loss. Equipment Installation: 1. a. Equipment shall be installed as required by the terms of their approval, in accordance with the conditions of the listing, the manufacturer's installation instructions and the MN State Mechanical Code. Manufacturer's installation instructions shall be available on the job site at the time of inspection. (MMC section 304.1) b. Provide electrical outlet near mechanical equipment. (MMC section 306.5.2) c. Suspended unit heaters shall be supported by elements that are designed and constructed to accommodate the weight and dynamic loads. Hangers and brackets shall be of noncombustible material. (MFGC 620.2) d. Minimum clearances to combustible materials unless listed otherwise shall be: sides = 18", bottom = 12", top = 6". (MFGC 620.4) Venting: a. Appliance venting shall comply with the manufacturer's instructions, MFGC section 503.8 item 3, and MMC section 804. b. Vents shall be sized, installed, and terminated in accordance with the vent and appliance manufacturer's installation instructions and MFGC 503. (MFGC 502.5) c. All portions of vents shall be adequately supported for the design and weight of the materials employed. (MFGC 502.6) Gas Pi ip na: a. Gas piping shall be sized in compliance with MFGC section 402. b. Corrugated stainless steel tubing (CSST) gas piping systems shall be bonded to the electrical service grounding electrode system with minimum 6 A WG copper wire of equivalent. (MFGC section 310.1.1) c. Gas piping exposed to corrosive action shall be protected in an approved manner. (MFGC section 404.11) d. Underground piping systems shall be installed a minimum depth of 12 inches below grade. Individual underground lines serving outdoor appliances shall be installed a minimum depth of 8 inches. (MFGC section 404.12) e. Steel gas piping sizes % inch shall be supported at intervals not greater than 6 feet, Y4 inch and 1 inch shall be supported at intervals of not greater than 8 feet, and piping sizes 1 % inch and larger shall be supported at intervals not greater than 10 feet. Refer to MFGC Table 415.1 of MFGC section 415 for support information for other sizes and/or materials. f. Gas piping shall be elevated no less than 3% inches above the ground/roof surface and protected from physical damage. (MFGC section 404.9) g. A minimum 3-inch sediment trap shall be installed prior to the regulator. If a tee fitting is used, it shall provide a 90-degree change in direction of gas flow. (MFGC 408.4) h. Each appliance shall be provided with a shutoff valve in the gas line, separate from the appliance and no further than 6 feet from the appliance, or located within 50 feet of the appliance when located at a manifold. (MFGC section 409.5) i. A readily accessible main shutoff valve with a permanently attached handle shall be installed in the first available location before the first branch line inside the building. (MFGC section 409.1.4) j. Gas piping that serves equipment on the roof of a building shall have a main shutoff valve located no closer than 10 feet from the roof edge and before the first branch line. (MMC section 409.1.4 exception) k. All new gas piping shall be tested and inspected in compliance with MFGC section 406. .r' Spring Park SPRING PARK i. Test Pressure: 1 % to operating pressure but not less than 25 psig ii. Duration: thirty (30) minutes iii. Gauge: 2 psig increments iv. Test Pressure: Shall be within the middle 50 percent of the gauge pressure range L A final gas piping system, appliance and equipment leakage test shall be conducted in the presence of the inspector at the final inspection. (MFGC section 406.6) Thank you for your Payment! Transaction ID: 14882 Transaction Number: Transaction Type: Payment Recipient: Contractor/Owner Notes: Fees (4) 1 Cl rY OF E rZI I C='P r1kR MINNESOTA City of Spring Park 4349 Warren Avenue SP MN,55384 Ph:952-442-7520 $199.25 Date: 2/8/2022 Method: Check: 3924 Address: 3701 SUNSET DRIVE, SP, MN 55384 Reference: Permit Number: SP-2022-00011 Type: MECH - General (Comm) for MSP HOLDINGS LLC Plan Review Fee Paid 1.00 $48.75 State Surcharge Paid 1.00 $0.50 Permit Fee - PLG, MECH Comm Paid 1.00 $75.00 Special Investigation Fee Paid 75.00 $75.00 $48.75 $0.50 $75.00 $75.00 Total Amount: $199.25 Page 1 of 1 Printed on- 2/8/2022