Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permits - Permit# 22SP-00049 - 4177 Shoreline Drive - 11/22/2022
City of Spring Park Plumbing (Commercial) Ai 4349 Warren Ave, Spring Park, MN 55384 22SP-00049 PRING PARK )n La e�Ninneton a (952)471-9051 (952)471-9160 For Inspections: (952)442-7520 Date Issued: 11/22/2022 Property Owner: MTK PROPERTIES Expiration Date: 05/21/2023 Mailing Address: 2425 GRAYS LANDING RD Job Site Address: 4177 SHORELINE DRIVE UNIT 105, SPRING PARK, MN 55384 WAYZATA, MN 55391 Category: Commercial Miscellaneous Phone: Permit Type: Plumbing (Commercial) Email: Valuation: $3,000.00 Description of Work: UNIT 105-REPLACE FIXTURES,ADD LAUNDRY BOX(105/107) Subdivision: Required Setbacks: Parcel ID: Filing: Lot: Actual Setbacks: Block: Total Sq Ft: Contractors: Fee Items Amount Primary Tradesman Inc. (612)581-4472 State Surcharge $ 1.50 Commercial Plumbing Permit $ 120.25 Commercial Plumbing Plan Review $78.16 Total Fees: $ 199.91 NOTICE Signature of Applicant/Date Building Department Signature/Date 11/22/2022 MUST BE POSTED ON JOB SITE xkua INSPECTION CARD City of Spring Park SPRING PARK On Lake.%finnetonkp 4349 Warren Ave, Spring Park, MN 55384 POST THIS CARD IN A SAFE CONSPICUOUS LOCATION.PLEASE DO NOT REMOVE THIS NOTICE UNTIL ALL REQUIRED INSPECTIONS ARE MADE AND SIGNED OFF BY THE APPROPRIATE AUTHORITY AND THE BUILDING IS APPROVED FOR OCCUPANCY.STAMPED APPROVED PLANS MUST BE AVAILABLE ON THE JOBSITE. Plumbing PERMIT NO.: 22SP-00049 PERMIT TYPE: (Commercial) ISSUED DATE: 11/22/2022 EXPIRATION DATE: 05/21/2023 PROJECTADDRESS: 4177 SHORELINE DRIVE UNIT 105,SPRING PARK,MN 55384 PARCEL NO.: OWNER: MTK PROPERTIES CONTRACTOR: Tradesman Inc. CONTRACTOR PHONE: (612)581-4472 DESCRIPTION OF WORK: UNIT 105-REPLACE FIXTURES,ADD LAUNDRY BOX(105/107) CONSTRUCTION TYPE: OCCUPANT LOAD: DATE DATE INSPECTION INSP PASSED COMMENTS INSPECTION INSP PASSED COMMENTS Plumbing Rough-In Plumbing Final Fire Approval: Date: Engineering Date: Approval: PW Approval: Date: Other( ): Date: To request an inspection:(952)442-7520 Paae 1 of 1 City of Spring Park COMMERCIAL PLUMBING PERMIT 4349 Warren Ave. AND PLAN REVIEW APPLICATION Spring Park, MN 55384 City: 952-471-9051 MNSPECT: 952-442-7520 Permit Number: acSJ�--QQO Project (site) Address '/77 }b1t'(.tpJC ��, owner's Phone 1 Z — P&, 90 y�- Business Name Owner's Name f�l/I� City/State/Zip Owner's Address Plumbing Contractor/Designer' aAEE72_ atj 1 j�e, Phone Col Z- s f 1 -yy7,)- Address_ TO 60)c 11,o-7?, j City/State/Zip _jyj«jy� Bond Number: (,pl :Z Z ', Plumbing License Number: TYPE(S) OF WORK: ❑ New Construction ❑Addition ..Remodel ,Replacement ❑ Food service/bar/lodging ❑ Hospital/Nursing Home EST VALUATION OF WORK: $ PROJECT DESCRIPTION: �►°LbEP�1=-i,��t,�.t„� BUILDING SERVICE INFORMATION: Sewer: ❑ New Municipal )(Existing Municipal ❑ New On-Site Septic o Existing On-Site Septic Water: ❑ New Municipal Ni"Existing Municipal ❑ New Private Well ❑ Existing Private Well PLEASE INDICATE ALL FIXTURES INCLUDED IN THIS PERMIT: Water Closet(toilet) I Bathtub Floor Sink _Lavatory (wash basin) Shower Piping/Treating Equipment _Kitchen Sink& Disp. i Dishwasher Catch Basin Total Number Laundry Tray Clothes Washer Vacuum Breakers Water Heater Water Softener Lawn Sprinkler System Of Fixtures _Urinal Drinking Fountain Roof Leader-Rainwater Rough-in Future Fix. Sump Septic Tank& Drain Field Misc. Fixtures Floor Drain Water Piping System Signature of this application by the legal property owner or a licensed contractor,as the owner's representative is required and authorizes the Municipality Zoning Administrator or designee and the Municipality Building Offidal or designee to enter upon the property to perform needed inspections. Entry maybe without prior notice. I hereby acknowledge that I have read this application and state that all information is true and correct to the best of my knowledge.I further agree that all work performed will be in accordance with approved plans,specifications and conditions,and to abide by all of the ordinances of the Municipality and the Laws of the State of Minnesota regarding actions taken pursuant to this permit,I agree to pay all plan review fees even Z,kif I c se not to proceed with the wor . I certify that this plumbing system was designed in accordance with the Minnesota Plumbing Code(as amended)to the best of my abil'i , nd I gree to orw d tepo an ns to tl�install of the system. Signature Print Signature Name Date Approved valuation: Permit Fee ........................... • Code Review ....................... r13.I(o Permit issued by: State Surcharge .................. •50 C� License Look Up ---- Other .................................. - Date: /o/vi Total Permit Charge $ 1 3 `- MN� I lea lam. �10373SOlfd t ) , , _MNd I C i o1,e �N 1� -L-V e^' e.1 I ,A �' Siff All 4o n C ,L4 woo,auiluouosnbjaj sailddnS OVAH pue 6uigwnld 's6uiuij'sanlen'adid leu}snpul pue leiaiawwoo dnOaJ iyidisn(INI 0 0 )L3,3S,oM NosnE)113:1 FERGUSON WOLSELEY INDUSTRIAL GROUP Standard Pipe Chart Steel Pipe Sizes, Weights & Dimensions Outer Schedule Schedule Schedule Schedule Schedule Schedule Schedule Schedule Schedule Schedule Schedule Size Diameter 5 10 20 30 40 Standard 60 80 X-Heavy100 120 140 160 XX-Heavy 1/8 0.405 .035 .049 .068 .068 .095 .095 .138 1863 2.447 2.447 .3145 .3145 0.540 .049 .065 .088 .088 .119 .119 1/4 .2570 .3297 .4248 .4248 .5351 .5351 0.675 .049 .065 .091 .091 .126 .126 318 1 .3276 1 .4235 .5676 .5676 1 .7388 .7388 0.840 •065 .083 .109 .109 .147 .147 .187 .294 1/2 .5383 .6710 .8510 .8510 1.088 1.088 1.304 1.714 1.050 .065 .083 .113 .113 .154 .154 .218 .308 314 6838 .8572 1.131 1.131 1.474 1.474 1.937 2.441 1.315 .065 .190 .133 .133 .179 .179 .250 .358 1 .8678 1.404 1.679 1.679 2.172 2.172 2.844 3.659 1.660 .065 .109 .140 .140 .191 .191 .250 .382 11/4 1.107 1.806 2.273 2.273 2.997 1 2.997 1 3.765 5.214 1.900 .065 .109 .145 .145 .200 .200 .281 .400 11/2 1.274 1 2.638 2.718 2.718 3.631 3.631 1 4.859 6.408 2.375 .065 .109 .154 .154 .218 .218 .343 .436 2 1.604 2.638 3.653 3.653 5.022 5.022 7.444 9.029 2.875 •083 .120 .203 .203 .276 .276 .375 .552 21/2 2.475 3.531 5.793 5.793 T661 7.661 10.01 13.70 3.500 .083 .120 .216 .216 .300 .300 .437 .600 3 3.029 4.332 7.576 7.576 10.25 10.25 14.32 18.58 4.000 .083 .120 .226 .226 .318 .318 .636 31/2 3.472 4.973 9.109 9.109 12.51 12.51 22.85 4.500 .083 .120 .237 .237 .281 .337 .337 .437 .531 .674 4 3.915 5.613 10.79 10.79 12.66 14.98 14.98 19.01 22.51 27.54 5.000 .247 .365 .710 4 1/2 12.53 17.61 32.53 5.563 .109 .134 .258 .258 .375 .375 .500 .625 .750 5 6.349 7.770 14.62 14.62 20.78 20.78 27.04 32.96 38.55 6.625 .109 .134 .280 .280 .432 .432 .562 .718 .864 6 7.585 9.289 18.97 18.97 28.57 28.57 36.39 45.30 53.16 7.625 .301 .500 .875 7 23.57 38.05 63.08 8.625 .109 .148 .250 .277 .322 .322 .406 .500 .500 .593 .718 .812 .906 .875 8 9.914 13.40 22.36 24.70 28.55 28.55 35.64 43.39 1 43.39 50.87 60.63 67.76 74.69 72.42 9.625 .U2 .500 9 33.90 48.72 10.750 .134 .165 .250 .307 .365 .365 .500 .593 .500 .718 .843 1.000 1.125 10 1 15.19 18.65 28.04 34.24 40.48 40.48 1 54.74 64.33 54.74 76.93 89.20 104.1 115.7 11.750 .375 .500 11 45.55 60.07 12.750 .156 .180 .250 .330 .406 .375 .562 .687 .500 .843 1.000 1.125 1.312 12 21.07 24.20 33.38 43.77 53.53 49.56 73.16 88.51 1 65.42 107.2 1 125.5 139.7 160.3 14.000 .156 .250 .312 .375 .437 .375 .593 .750 .500 .937 10.93 1.250 1.406 14 23.06 36.71 45.68 54.57 63.37 54.57 84.91 106.1 72.09 130.7 150.7 170.2 189.1 16.000 .165 .250 .312 .375 .500 .375 .656 .843 .500 1.031 1.218 1.437 1.593 16 27.90 42.05 52.36 1 62.58 82.77 62.58 1 107.5 136.5 82.77 164.8 192.3 223.5 245.1 18.000 .165 .250 .312 .437 .562 .375 .750 .937 .500 1.156 1.375 1.562 1.781 18 31.43 47.39 59.03 82.06 104.8 70.59 138.2 170.8 93.45 208.0 244.1 274.2 308.5 20.000 .188 .250 .375 .500 .593 .375 .812 1.031 .500 1.280 1.500 1.750 1.968 20 39.78 52.73 78.60 104.1 122.9 78.60 166.4 208.9 1 104.1 256.1 296.4 341.1 379.0 24.000 .218 .250 .375 .562 .687 .375 .968 1.218 .500 1.531 1.812 2.062 2.343 24 55.37 63.41 94.62 140.8 171.2 94.62 238.1 296.4 125.5 367.1 429.4 483.1 541.9 26.000 .312 .500 .375 .500 26 85.60 1 136.2 102.6 1 136.2 28.000 .312 .500 .625 .375 .500 28 92.26 146.8 182.7 110.6 146.8 30.000 .250 .312 .500 .625 .375 .500 30 79.43 98.93 157.5 196.1 118.6 157.5 32.000 .312 .500 .625 .688 .375 .500 32 106.6 168.2 209.4 230.1 126.7 168.2 34.000 .344 .500 .625 .688 .375 .500 34 123.7 178.9 222.8 244.8 134.7 178.9 36.000 .312 .500 .625 .750 .375 .500 36 118.9 189.6 236.1 282.3 142.7 189.6 42.000 .375 .500 42 166.7 221.6 48.000 .375 .500 48 190.7 253.6 Wt/Ft = 10.69 x (01D - Wall Thickness) x Wall Thickness FERGUSON WOLSELEY INDUSTRIAL GROUP Standard Pipe Chart Steel Pipe Sizes, Weights & Dimensions Outer Schedule Schedule Schedule Schedule Schedule Schedule Schedule Schedule Schedule Schedule Schedule Size Diameter 5 10 20 30 40 Standard 60 80 FX.Heavy100 120 140 160 XX-Heavy 1/8 0.405 .03E .135 69 2'068.447 2 o66 3095145 3095 145 1/4 0.5/0 .25 0 .32 4208E .4246 .535g 53519 0.675 •� .065 .091 .091 .126 .126 3/8 .3276 1 .4235 .5676 .5676 .7388 .7388 U M .083 .109 .109 .147 .147 .197 .294 . 1/2 840 .5383 .6710 .8510 .8510 1.08E 1.08E 1.304 1.714 1.050 •� .083 .113 .113 .154 .154 218 .308 3/4 .6838 .8512 1.131 1.131 11 1.474 1.937 2.441 1.315 •M •1� .133 .133 .179 .179 .� .358 1 .8678 1.404 1_679 1.679 2.172 2.172 2.844 3.659 1 065 .109 .140 .140 .191 .191 250 .382 11/4 .860 1.107 1.806 2.273 2.273 2.997 2.997 32M 5.24 1.900 '065 .109 .145 .145 .200 .200 .281 .400 112 1.274 2.638 2.718 2.718 3.631 3.631 4.859 6.408 2.375 065199 .154 A54 .218 .218 2 1*604 2.63E 3.653 3.653 5.022 5.022 43 7..344 9.029 2.075 •083 1� .203 .203 .276 .276 .375 .552 212 2.47.. 3.531 5.793 5.793 7.661 7.661 10.01 1370 3 083 .120 .216 .216 .300 .300 .437 .600 3 .500 '3.029 1.3✓2 7.576 7.576 10.25 10.25 14.32 18.58 3 12 3 4.000 •082 •120 .226 .226 .318 .318 4 n 6367� 9.109 9.109 12.51 12.51 22.85 4.500 •083 .120 .237 .237 .281 .337 .337 .437 .531 .674 4 - S.0 I"5 10.79 10.79 12.66 14.98 1796 - Z7.54 412 5.000 .247 355 12.53 17.61 /.710 5 5.563 .109 `.134 .258 .25E .375 .375 .500 .625 .750 14,62 14,62 20.78 20.78 27.04 32.96 38.55 6.625 .109 .134 .280 .280 .432 .432 592 .718 .864 8 7.58E 9.289 18.97 18.97 28.57 28.57 36.39 45.30 53.16 7.625 .301 .500 .875 7 23.57 38,05 63,08 8.626 .109 .148 .250 .277 .322 .322 .406 .500 .500 .593 .718 .812 .906 .875 8 3.4E 22.36 247C- 28.55 28.55 35.64 4'5,39 43.39 50.87 60.63 67 76 74.69 72.42 9 9.625 .342 500 33.90 48.72 10.750 '134 .165 .250 .307 .365 .365 .500 .593 .500 .718 w 1.000 1.125 10 15.1y 18.65 28.04 34.24 40.4E 40.48 5474 64.33 54.74 76.93 89,20 104.1 115.7 11 11.750 .375 500 45.55 60A7 12.750 '156 '180 250 .330 .406 .375 .562 .687 .500 .843 1.000 1.125 1.312 12 21.07 24.20 33.38 43.77 53.53 49.56 73.16 88.51 65.a2 107.2 125.5 139.7 16 U 14.000 .156 .250 .312 .375 .437 .375 .593 .750 .500 .937 10.93 12M 1.406 14 23.".1& 3G.71 45.68 54.57 63.37 54.57 34.91 106.1 72.09 130.7 150.7 170.2 189.1 16.000 .165 .250 .312 .375 '500 .375 .656 .843 .500 1.031 1.218 1.437 1.593 16 42.r 52.3E 62.58 62.77 32.5E 107.5 136.5 32.77 164.8 192.3 223.5 245.1 18.000 .165 .250 .312 .437 562 .375 .750 .937 .500 1.156 1.375 1.562 1.781 18 4Z'. d2.°r 104.f• 70.5,1 138.2 170.a 93.45 208.0 244.1 274.2 30p 6 20.000 •188 •250 .375 .500 .593 .375 .812 1.031 .500 1.280 1.500 1.750 1.968 20 39.7E 5273 'n.C" 104.1. 122.9 78.60 166.4 208.9 1'14.1 256.1 296.4 341.1 379.G 24.000 218 250 .375 .562 .687 .375 .968 1.218 .500 1.531 1.812 2.062 2.343 24 55.31 63.41 94.62 140.E 1'12 44.62 238.1 296.4 ;25.5 367.1 429.4 453.1 541.9 26.000 .312 .500 .375 .500 28 1 86.60 136.2 102.6 136.2 28.000 .312 .500 .625 .375 '500 28 92.26 146.8 182.7 110.6 146.8 30.000 .250 .312 .500 .625 .375 •500 30 'P,43 98.93 1 157.E 196.1 118.6 157.5 32.000 .312 .500 .625 .688 .375 •500 32 105.6 168.2 209< 230.i 126.7 166.2 34.000 .344 .500 .625 .688 .375 .500 34 123.7 178.9 222.8 244.E �34.7 178.0 36.000 .312 .500 .625 .750 .375 .500 36 118.9 10.6 236.? 1 282.3 14�."" 1E<.. 42 42.000 1.375 .500 221.6 375 48 48.000 1pn 7 500 Wt/Ft = 10.69 x (OD - Wall Thickness) x Wall Thickness Commercial Plumbing This Plan Must Be Maintained And e Accessible On The Construction Read All Attached Materials? ion SUMP COVERS MUST BE SURD MRTERIAL Manufacturers In stallat AND SECURED- instructions shall be available on the 4715.0340 SUBPART 4 job site at the time of Inspection ALL WATER SUPPLY PIP IOTECfED AGAINST RIOR WALLS SHALL BE ADEQUATELY The approved plans and a copy of FREEZING BY INSULAl ION,HEAT,OR BOTH the MN the plan review letter u m must M�]be ALL WATER FR©M FOUNDATION ©MAINS Dept. of Labor and 1 rY OR SUMPS MUST BE PUMPED R DRAINED on site at-the time of all inspections. DIRECTLY TO THE EX RIGID PLASTIC OR STEEL PIPING. NO NOT be conducted SUMP WATEROR DRA NS IS ESINK OR ANY D TO BE ED An inspection will N INTO FL© if the required documents are no on OTHER ACCESS TO SANITARY SE11�tER• site at the time of the scheduled inspection. - CONTRACTOR SHALL VERIFY S�,NiTARY ON TO SEWER ELEVATI THE LOWEST FLOOR ELEVATI LATIN PRIOR Must Post Address on TO CONSTRUCTION. Construction MN Rule 4715.0200 N Site,Visible from the Road plumbing shall be installed with due ation of the OF THE resery event on of IT IS THE RESPON L GOPHER STATE of structuralo members and pr CONTRACTOR TO CAL ONE CALL 651-454-0002, OR 8111 BEFORE damage to the watts and other surfaces BEGINNING EXCAVATI through fixture usage. NO OCCUPANCY OR USE ALLOWED MN Rule 4715 0300 Si All pipes passing under or through UNTIL FINAL INSPECTION AND APPROVAL otected from breakage. walls shall be pr CALL BUILDING INSPECTOR 952-442-7520 assing through or in contact 00 FINE PENALTY-MAXD"$750. All pipes p WORK FOR with cinder, concrete, against other EVERY PERSON PERFORMING W material shall be protected coating, WHICH THE CODE IS APPLICABLE, SHALL external corrosion by protective COMPLY WITH THE CODE. wrapping, or other means that will resist such corrosion. FOR ALL INSPECTIONS SUB COMPLIANCE SUBJECT TO CODE }CALL 24 HOURS IN DURING CONSTRUCTION ►.GIVE PERMIT NUMBER ADVANCE 22SP- 00 REVIEWED '7CR •oDE COMPLIANCE (952) 442�-7520 SPRING PARK on Lake Minnetonka City of Spring Park 4349 Warren Avenue, Spring Park, MN 55384 Phone: (952) 471-9051 / Fax: (952) 471-9160 / Web: www.ci.spring-park.mn.us November 10, 2022 Plans and Specifications: MTK Properties 4177 Shoreline Drive Unit 105 Spring Park, MN 55384 Owner: Mark Kozikowski Project Designer: Tradesman Inc. PO Box 26731 Minneapolis, MN 55426 Scope: The project consists of the installation of new drain,waste, vent, and water piping for future bathroom and laundry, also fixture replacement. this building is served by an existing municipal sewer and water system. Approval: The plans for the project named above have been reviewed for substantial compliance with the 2015 Minnesota State Plumbing Code and do not cover the water supply or sewage system to which this plumbing system is connected. The review is limited to the design submitted; and assumes the information on which the design is based is correct, and that necessary legal authority has been obtained to construct the project. Approval is contingent upon satisfactory disposition of any requirements included in this report. Inspections: All plumbing installations must be tested and inspected in accordance with the requirements of the Minnesota State Plumbing Code as specified in the Minnesota Rules, parts 4714.103 .5 through 4714. 103. 8. It is the responsibility of the contractor/installer to notify the inspection department when ready to schedule an inspection. Call the building inspection department on (952) 442-7520 between the hours of 8:30 a.m. and 4:30 p.m. Monday through Friday. General Requirements: 1. All plumbing shall be installed per MN Rules, part 4714.0100 2. The plumbing system shall be tested in accordance with MN Rules, part 4714. Section 609.4 and 712.0 and 1109.0 3. As per MN Rules, part 4714. 609. 9. New or repaired potable water systems shall be disinfected prior to use where required by the authority having authority. 4. Verify that the water distribution pipes are sized according to MN Rules, Chapter 4714, and Section's 610.7 through 610.12. 5. Equipment used for heating water or storing hot water shall be protected by approved safety devices in accordance with MN Rules, Chapter 4714, Sections 504.4, 504.5 and 504.6. 6. As per MN Rules, part 4714.312.9 Plastic and copper piping penetrating framing members shall be protected by steel nailing plates. The steel plates shall extend along the framing member not less than 1 '/2 "beyond the outside diameter of the pipe. 7. As per MN Rules, part 4714. 707. 5 each cleanout shall be installed so that it opens to allow cleaning in the direction of flow of the soil or waste or at right angles thereto. 8. As per MN Rules, part 4714.707.4 each horizontal drain branch, including floor drains branches, shall be provided with a clean out at its upper terminal. 9. All horizontal drainage pipe must be pitched at inch per foot, unless otherwise approved by the administrative authority. Except for trap arms, all drains to urinals must be 2 inches. 10. As per MN Rules, part 4714.section603.5.7 all threaded hose connections must be provided with an approved safety device. 11. As per MN Rules, part 4714. 0810 solvent weld joints in PVC and CPVC must include use of a primer which is of a contrasting color to the pipe and cement. 12. Materials used for drain, waste and vent systems must comply with the MN Rules, part 4714. 701. 1. As amended. 13. Verify water supply lines comply with MN Rules, part 4714. 604. 1. If you have any questions or concerns regarding this plan review, please direct them to the Plumbing Inspector at 952-442-7520 /888-446-1801. Sincerely, Dale Engelmann Plumbing Plan Examiner (952) 442-7520 Cc: Municipality Property file RECEIPT City of Spring Park �^ 4349 Warren Ave, Spring Park, MN 55384 (952)471-9051 SPRING PARK 22SP-00049 1 Plumbing (Commercial) On Lake 911innetonka Receipt Number:88 Payment Amount: $199.91 November 22,2022 Transaction Method Payer Cashier Reference Number Check MTK Properties Jamie Hoffman 8504 Comments Assessed Fee Items Fee items being paid by this payment Date Fee Item Account Code Assessed Amount Paid Balance Due 11/14/22 State Surcharge $1.50 $1.50 $0.00 11/14/22 Commercial Plumbing Permit $120.25 $120.25 $0.00 11/14/22 Commercial Plumbing Plan Review $78.16 $78.16 $0.00 Totals.• $199.91 $199.91 Previous Payments $0.00 Remaining Balance Due $0.00 Permit Info Property Address Property Owner Property Owner Address Valuation 4177 SHORELINE DRIVE MTK PROPERTIES 2425 GRAYS LANDING RD $3,000.00 UNIT 105 WAYZATA, MN 55391 SPRING PARK, MN 55384 Description of Work UNIT 105-REPLACE FIXTURES,ADD LAUNDRY BOX(105/107)