Permits - Permit# 23SP-00015 - 4100 Spring Street - 2/3/2023 M(V —` 14� City of Spring Park Plumbing (Commercial)
4349 Warren Ave, Spring Park, MN 55384
23SP-00015
WRING PARK
n La a-Minneton a (952)471-9051 (952)471-9160
For Inspections: (952) 442-7520
Date Issued: 02/03/2023 Property Owner: MARY LOU &WILLIAM A KESSELRING
Expiration Date: 08/02/2023 Mailing Address:
Job Site Address: 4100 SPRING STREET UNIT 302,
SPRING PARK, MN 55384
Category: Commercial Miscellaneous Phone:
Permit Type: Plumbing (Commercial) Email:
Valuation: $1,000.00
Description of Work:
BATHTUB AND SURROUND BEING REPLACED WITH A WALKIN SHOWER AND SURROUND, INCLUDING THE MIXING
VALVE AND TRAP
Subdivision: Required Setbacks:
Parcel ID: 1811723440081
Filing:
Lot: Actual Setbacks:
Block:
Total Sq Ft:
Contractors: Fee Items Amount
Primary LEAF HOME ENHANCEMENTS, LLC (920) State Surcharge $0.50
663-5755
Commercial Plumbing Permit $75.00
Commercial Plumbing Plan Review $48.75
Total Fees: $ 124.25
NOTICE
Signature of Applicant/Date Building Department Signature/Date
02/03/2023
MUST BE POSTED ON JOB SITE
Mw INSPECTION CARD
:::�t City of Spring Park
SPRING PARK
On Lake Minnetonkg 4349 Warren Ave, Spring Park, MN 55384
POST THIS CARD IN A SAFE CONSPICUOUS LOCATION.PLEASE DO NOT REMOVE THIS NOTICE UNTIL ALL REQUIRED INSPECTIONS ARE MADE AND SIGNED OFF BY THE APPROPRIATE
AUTHORITY AND THE BUILDING IS APPROVED FOR OCCUPANCY.STAMPED APPROVED PLANS MUST BE AVAILABLE ON THE JOBSITE.
Plumbing
PERMIT NO.: 23SP-00015 PERMIT TYPE: (Commercial) ISSUED DATE: 02/03/2023 EXPIRATION DATE: 08/02/2023
1811723440
PROJECT ADDRESS: 4100 SPRING STREET UNIT 302,SPRING PARK,MN 55384 PARCEL NO.: 081
MARY LOU&WILLIAM A
OWNER: KESSELRING CONTRACTOR: LEAF HOME ENHANCEMENTS,LLC CONTRACTOR PHONE: (920)663-5755
BATHTUB AND SURROUND BEING REPLACED WITH A WALKIN SHOWER AND SURROUND,INCLUDING THE MIXING
DESCRIPTION OF WORK: VALVE AND TRAP
CONSTRUCTION TYPE: OCCUPANT LOAD:
DATE DATE
INSPECTION INSP PASSED COMMENTS INSPECTION INSP PASSED COMMENTS
Underground Plumbing Plumbing Rough-In
Plumbing Final
Fire Approval: Date: Engineering Date:
Approval:
PW Approval: Date: Other( ): Date:
To request an inspection:(952)442-7520
Paae 1 of 1
City of Spring Park COMMERCIAL PLUMBING PERMIT
4349 Warren Ave. AND PLAN REVIEW APPLICATION
Spring Park, MN 55384
City: 952-471-9051 MNSPECT: 952-442-7520 Permit Number: 23SP-
Job Address 4100 Spring St Apt 302 Owner's Email
Owner's Name Kesselring,Bin Business Name
Address City/State/Zip Phone
Plumbing Contractor/Designer t.eafHnme Enhancements DBATundraland Email mnpermits@tundraland.com
Address N2277 W41 Fronalge Rd City/State/Zip Kaukauna,WI 54130 Phone
State Bond No. Plumbing License No.
I
TYPES)OF WORK: ❑ New Construction ❑Addition ❑ Remodel ❑ Replacement
❑ Food service/bar/lodging ❑ Hospital/Nursing Home
EST VALUATION OF WORK: $ PROJECT DESCRIPTION:
Bathtub and surround being replaced with a walkin shower and surround,including the mixing valve and trap
BUILDING SERVICE INFORMATION:
Sewer: n New Municipal ❑ Existing Municipal ❑ New On-Site Septic ❑ Existing On-Site Septic
Water: ❑ New Municipal ❑ Existing Municipal ❑ New Private Well ❑ Existing Private Well
PLEASE INDICATE ALL FIXTURES INCLUDED IN THIS PERMIT:
Water Closet(toilet) Bathtub Floor Sink
Lavatory(wash basin) 1_Shower Piping/Treating Equipment Total Number
Kitchen Sink&Disp. Dishwasher Catch Basin
Laundry Tray Clothes Washer Vacuum Breakers Of Fixtures
Water Heater Water Softener Lawn Sprinkler System
Urinal Drinking Fountain Roof Leader-Rainwater
Rough-in Future Fix. Sump Septic Tank& Drain Field
Misc. Fixtures Floor Drain Water Piping System
Signature of this application by the legal property owner or a licensed contractor,as the owner's representative Is required and authorizes the Municipality Zoning Administrator or designee
and the Municipality Building Official or designee to enter upon the property to perform needed inspections. Entry may be without prior notice. I hereby acknowledge that I have read this
application and state that all information Is true and correct to the best of my knowledge.I further agree that all work performed will be in accordance with approved plans,specifications
and conditions,and to abide by all of the ordinances of the Municipality and the Laws of the State of Minnesota regarding actions taken pursuant to this permit,I agree to pay all plan review
fees even If I choose not to proceed with the work. I certify that this plumbing system was designed in accordance with the Minnesota Plumbing Code(as amended)to the best of my
abilities,and I agree to forward the report and plans to the installer of the system.
Signature Print Signature Name Date
Approved valuation:
Permit issued by:
n'L
Date: /--
Page 113
THIS PAGE MUST ACCOMPANY ALL COMMERCIAL PLUMBING PERMIT APPLICATIONS
The following checklist has been compiled to assist in expediting the commercial plan review and permit
issuance process. Please take a moment to review these submittal requirements and to verify all of the
necessary documentation prior to submitting your project.
PLUMBING PERMIT and PLAN REVIEW—THE FOLLOWING ITEMS ARE REQUIRED:
❑ Completed permit application including:
❑ Site Address (including Suite#)and Business Name
❑ Owner
❑ Owner Address
❑ Telephone Number
❑ Contractor Information (if applicable)
❑ Valuation of work being performed
❑ Description of work being performed
❑ Signature of applicant
❑ Date
❑ 2 sets of Signed Plumbing Plans
❑ Utility Site Plan/Floor Plan/Roof Plan
❑ Water Riser/Soil, Waste, Vent Riser Diagrams
❑ Plumbing Specifications
❑ Copy of Plumbers License/Bond
❑ Complete and provide Service Water Heating Compliance Forms for compliance with the Minnesota State Energy
Code(https://www.ashrae.org/standards-research--technology/standards-forms—procedures)
PLUMBING PLAN REVIEW— Please provide the following information:
Choose one of the following:
❑ Building Sewer and/or Water Service Only (this fee applies when no interior plumbing is to be installed)
$150 flat fee
❑ Plumbing System (Water distribution and drain/waste/vent systems within the building, and water and/or sewer
service connections, if applicable).
This portion of the fee is based on total number of drainage fixture units(DFU)
Total DFU
a. 25 or fewer DFU $ 150
b. 26 to 50 DFU $250
c. 51 to 150 DFU $350
d. 151 to 249 DFU $500
e. 250 or more DFU: $3 x_DFU $ Maximum$4,000
❑ Interceptors/Separators(grease interceptors, flammable water interceptors, etc...)
x$70=$ or❑ None
❑ Storm Drainage System $150 minimum OR
Each internal roof drain opening ($500 max.) x$50=$ or❑ None AND/OR
Each storm water interceptor, separator, or catch basin design x$70=$ or❑ None
❑ Manufactured Home Park or Campground
a. 25 or fewer sites $300 c. 51 to 125 sites $400
b. 26 to 50 sites $ 350 d. 125 or more sites $ 500
TOTAL PLUMBING PLAN REVIEW $
Page213
PLUMBING PLAN REVIEW REQUIREMENTS
Below is a list of requirements necessary to complete a review of plumbing systems in commercial buildings.
Please read the following carefully to ensure you provide all required information to minimize delays in the plan
review process.
1. Utility Site Plan (if new services are to be installed): The utility plan must show the locations, sizes and
slopes of all sanitary sewer, all storm sewer, and water service piping within the property lines. If wells or
sewage treatment systems will be located on the property,they must be shown on the plan so that proper
isolation distances can be verified. The utility plan must indicate the pipe materials to be used for each service
unless otherwise listed in the specifications. The plan must include a directional reference.
2. Floor plan: The floor plan must show the locations of all plumbing fixtures. The sizes and locations of all
horizontal sanitary and storm piping must be shown on the plan.
3. Water Riser Diagram: The drawing must show an isometric view of the water distribution piping from the
water service entrance to the connection to all plumbing fixtures and equipment. The plumbing fixtures,
equipment connected to the water distribution system, and all pipe sizes must be clearly labeled on the
drawing.
4. Soil,Waste and Vent Riser Diagram: The drawing must show an isometric view of the waste and vent
piping within the building.All pipe sizes and fixtures must be clearly labeled on the drawing.
5. Material Specifications: A list of fixtures, materials, and procedures must be provided which includes the
following:
a. A list of the fixtures and appurtenances that are connected to the potable water distribution system or that
discharge to the sanitary waste system. The list must include manufacturer and model number of each
plumbing fixture or appurtenance.
b. The type and quality standard (e.g.ASTM,ANSI, etc.)of the pipe materials to be used in the plumbing
system, including the type of joints.
c. The pressure testing and disinfection procedures.
6. Roof plan: A roof plan must be provided if roof drains will be installed that are piped inside the building. If no
internally piped roof drains will be installed, a roof plan is not necessary for plan review.A statement should
be included that the roof is pitched and the building is served by scuppers.
7. Signature: All plumbing plans that are submitted to MNSPECT must be signed by a master plumber or a
professional engineer who is registered in the State of Minnesota. Signature and license number must be
on each plan sheet.
313
SAMPLE DIAGRAMS
Water Heater
P6 P1 Tank Water Closet
4- P2 Lavatory
P3 Urinal
ri 0 2" P4 Dishwasher
P8 P7 P5 Hand Sink
IGP r P6 Mop Sink
P7 3-Compartment Sink
P5 P4 P8 Floor Drain(without
P8 backwater valve)
O
3' 2"
4-
Clean Out
Figure 1
Floor Plan Maximum Developed Length:40 Feet
Pressure Range:46-60 psi
3/4' Individual Branches 1/2" Unless
Otherwise Noted
1"
Water Meter 3/4-
C\ P7 == Cold Water
Water Heater 3/4°P6 1 J2-
Hot Water
3/
1/2 P4
1/2"
ll2 4• P2 P5 2" VTR
3/ `
P1 P2
P1 �-3/a'-' P3 Figure 2 I
P1 Water Riser Diagram 1 1/4" 1
I'��.- I
3" VTR I P7 1 a
1 1-1/4'
I I 1 I
N i I C.O. 1 1 1 P4 1
I 112" 1 P6 P8 I
I 2"11 1 2' 1 P8 2-
3°l I I P2 1 4' P5
1 1 l 3"C.O.
P1 1 1-1/2' P2 24
P1 I P3 4' " 3-
I a
C.O.
Figure 3
C.O. 4' P1 Waste and Vent Riser Diagram
SAMPLE DIAGRAMS
I
4
I
i
Is
1
_ I
SPRING PARK
On Lake 9d innetonka t
j Spring Park, IVIN 55384
City of Spring Park 4349 Warren Avenue,
Phone: (952) 471-9051 / Fax: (952) 471-9160 / Web: www.ci.spring-park.mn.us
E
January 30, 2023 i
Plans and Specifications: Bill Kesselring
t 4100 Spring St.Apt. 302
Spring Park, MN 55384
t
Owner:
I
Project Designer: Leaf Home Enhancements DBA Tundralan
N2277 W41 Frontage Rd.
Kaukauna, WI 54130
Scope:The project consists of the installation of new drain,waste,vent, and water
piping and fixture replacement for a bathroom,this building is served by an existing
municipal sewer and water system.
( Approval:The plans for the project named above have been reviewed for substantial
compliance with the 2015 Minnesota State Plumbing Code and do not cover the water
supply or sewage system to which this plumbing system is connected.The review is
K limited to the design submitted; and assumes the information on which the design is
based is correct, and that necessary legal authority has been obtained to construct the
project. Approval is contingent upon satisfactory disposition of any requirements
a included in this report.
Inspections: All plumbing installations must be tested and inspected in accordance with
the requirements of the Minnesota State Plumbing Code as specified in the Minnesota
Rules, parts 4714.103 .5 through 4714. 103. 8. It is the responsibility of the
contractor/installer to notify the inspection department when ready to schedule an
R
inspection. Call the building inspection department on (952)442-7520 between the
hours of 8:30 a.m. and 4:30 p.m. Monday through Friday.
F,
t General Requirements:
1. All plumbing shall be installed per MN Rules, part 4714.
2. The plumbing system shall be tested in accordance with MN Rules, part 4714.
f
Section 609.4 and 712.0 and 1109.0
S
}E
p2
F
i
i
I
i
I
1
3. As per MN Rules, part 4714. 609. 9. New or repaired potable water systems shall be
disinfected prior to use where required by the authority having authority. #
4. Verify that the water distribution pipes are sized according to MN Rules, Chapter
4714, and Section's 610.7 through 610.12.
5. Equipment used for heating water or storing hot water shall be protected by
approved safety devices in accordance with MN Rules, Chapter 4714, Sections
504.4, 504.5 and 504.6.
6. As per MN Rules, part 4714.312.9 Plastic and copper piping penetrating framing `
members shall be protected by steel nailing plates. The steel plates shall extend
along the framing member not less than 1 1/2"beyond the outside diameter of the
pipe.
7. As per MN Rules, part 4714. 707. 5 each cleanout shall be installed so that it opens
to allow cleaning in the direction of flow of the soil or waste or at right angles thereto.
8. As per MN Rules, part 4714.707.4 each horizontal drain branch, including floor
drains branches, shall be provided with a clean out at its upper terminal.
9. All horizontal drainage pipe must be pitched at'/+ inch per foot, unless otherwise
approved by the administrative authority. Except for trap arms, all drains to urinals
must be 2 inches.
10. As per MN Rules, part 4714.section603.5.7 all threaded hose connections must be
provided with an approved safety device.
11. As per MN Rules, part 4714. 0810 solvent weld joints in PVC and CPVC must
include use of a primer which is of a contrasting color to the pipe and cement.
12. Materials used for drain,waste and vent systems must comply with the MN Rules,
( part 4714. 701. 1. As amended.
13. Verify water supply lines comply with MN Rules, part 4714. 604. 1.
C
if you have any questions or concerns regarding this plan review, please direct them to
the Plumbing Inspector at 952-442-7520 /888-446-1801.
? Sincerely,
Dale Engelmann
Plumbing Plan Examiner
(952)442-7520
I
Cc: Municipality Property file
C
C
1
Commercial Plumbing
This Plan Must Be Maintained nstructio S�e
Accessible On The
Read All Attached Materials!
SUMP COVERS MUST BE SOLID MRTERIAL
Manufacturers' installation AND SECURED.
Instructions shall be available on the 4715.0340 SUBPART 4
t the time of Inspection ALL WATER SUPPLY IPI PRIOTE�TED AGAINST
job site a SHALL BE ADEQUATELY
roved tans and a copy of FREEZING BY INSULATION,HEAT,OR BOTH
The approv pAINS
the plan review letter from the Mid ALL WATERFROM E PUMPED ED OR DRAINED
Dept. of Labor and Industry musNDATION DP
t be OR SUPS MU
on site at-the time of all inspections. DIRECTLY TO THE EY
STEELOPIPINGO NO
H
RIGID PLAS
�— conducted SUMP 1NATER 1S ALL-OafUED To BE pu S1NKs R ANY Ep
inspection will NOT be cond INTO FLOOR DRAINS,[A�n
f the required documents are not on OTHER ACCESS TO SANITARY SE1t�ER
site at the time of the schedule VERIFY SAi4ITARY
inspection. CONTRACTOR SH�L LATION TO
SE RE
WER ELEVATION IN
THE LOWF-ST FLOOR
ELEVATION
LE ION ON PRIOR
Must Post Address on TO COS
Construction
d MN Rule 4715.0200 N
from the Road -
Site,Visible Plumbing shall be installed with due
and to preservation off the vent on of
IT IS THE RESPONtrength
SIBG P°R STATE of sTHE tructural members an p surfaces
CONTRACTOR TO CAL damage to the walls and other
ONE CALEGINNING EXCAVATION OR 811 BEFORE through fixture usage.
B
MN Rule su15 0300
or t rough
NO OCCUPANCECTION AND APPRO AL All pipes passing from breakage-
UNTIL FINAL INSP walls shall be protected
CALL BUILDING INSPECTOR 952-�42-7520 i eS passing through or v1 contact
. PETIALTY-�$750.00 FINE All pipes p
With cinder, concrete, or other corrosive
EVERY PERSON PERFORMING WORK
FOR material shall be protected against
SHALL protective coating
WHICH THE CODE 15 APPLICABLE, external corrosion by
WITH THE CODE. - wrapping, or other means that will
COMPLY resist sucheorrosion.
FOR AL 24 HURSI
► G �NS-
. ALL
SUBJECT TO CODE COMPLIANCE
RUCTION ),,GIVE PERMIT NUMBER
DURING CONST
ADVANCE 23SP-00015
��R.,rn C MP NCE (952) 442�-7520
REVIEWED -
1
®E®®®■®
ON
■®®®® �► rONE fir
iTo
a
1 ;— 1
- +c
+
1
RECEIPT
City of Spring Park
4349 Warren Ave, Spring Park, MN 55384
(952)471-9051
SPRING PARK
23SP-00015 1 Plumbing (Commercial) On Gale Minnetonka
Receipt Number: 137
Payment Amount: $124.25 February 2,2023
Transaction Method Payer Cashier Reference Number
Credit Card Tundraland Jamie Hoffman 58928343
Comments
Assessed Fee Items
Fee items being paid by this payment
Date Fee Item Account Code Assessed Amount Paid Balance Due
01/31/23 State Surcharge $0.50 $0.50 $0.00
01/31/23 Commercial Plumbing Permit $75.00 $75.00 $0.00
01/31/23 Commercial Plumbing Plan Review $48.75 $48.75 $0.00
Totals: $124.25 $124.25
Previous Payments $0.00
Remaining Balance Due $0.00
Permit Info
Property Address Property Owner Property Owner Address Valuation
4100 SPRING STREET UNIT MARY LOU &WILLIAM A $1,000.00
302 KESSELRING
SPRING PARK, MN 55384
Description of Work
BATHTUB AND SURROUND BEING REPLACED WITH A WALKIN SHOWER AND SURROUND, INCLUDING THE MIXING
VALVE AND TRAP