Loading...
Permits - Permit# 23SP-00047 - 4232 West Arm Drive - 6/29/2023 City of Spring Park Repair/Remodel/Alteration (Residential) 4349 Warren Ave, Spring Park, MN 55384 PRING PARK 23SP-00047 Phone:(952)471-9051 Fax:(952)471-9160 n La a 9Kinneton a For Inspections: (952)442-7520 Date Issued: 06/29/2023 Property Owner: JUDITH H O'BRIEN TRUST Expiration Date: 12/26/2023 Mailing Address: 4232 WEST ARM DR Job Site Address: 4232 WEST ARM DR, Spring Park, MN 55384 Spring Park, MN 55384 Category: Residential Alteration Phone: (612)508-5854 Permit Type: Repair/Remodel/Alteration Email: jhob714@yahoo.com (Residential) Valuation: $350,000.00 Description of Work: Interior remodel&window replacement Subdivision: Required Setbacks: Parcel ID: 18-117-23-43-0180 Filing: Lot: Actual Setbacks: Block: Total Sq Ft: Contractors: Fee Items Amount Primary Warren Home Restoration Inc(952)474-6798 State Surcharge $ 175.00 Residential Building Permit $3,047.00 Contractor License Look-up $ 5.00 Lead Certification Look-up $5.00 Residential Plan Review $ 1,980.55 Total Fees: $5,212.55 NOTICE Signature of Applicant/Date Building Department Signature/Date 06/29/2023 MUST BE POSTED ON JOB SITE INSPECTION CARD *i=tz City of Spring Park SPRING PARK On Lake-%finnetonkp 4349 Warren Ave, Spring Park, MN 55384 POST THIS CARD IN A SAFE CONSPICUOUS LOCATION.PLEASE DO NOT REMOVE THIS NOTICE UNTIL ALL REQUIRED INSPECTIONS ARE MADE AND SIGNED OFF BY THE APPROPRIATE AUTHORITY AND THE BUILDING IS APPROVED FOR OCCUPANCY.STAMPED APPROVED PLANS MUST BE AVAILABLE ON THE JOBSITE. Repair/Remodel/Alte PERMIT NO.: 23SP-00047 PERMIT TYPE: ration(Residential) ISSUED DATE: 06/29/2023 EXPIRATION DATE: 12/26/2023 18-117-23- PROJECT ADDRESS: 4232 WEST ARM DR,Spring Park,MN 55384 PARCEL NO.: 43-0180 OWNER: JUDITH H O'BRIEN TRUST CONTRACTOR: Warren Home Restoration Inc CONTRACTOR PHONE: (952)474-6798 DESCRIPTION OF WORK: Interior remodel&window replacement CONSTRUCTION TYPE: OCCUPANT LOAD: DATE DATE INSPECTION INSP PASSED COMMENTS INSPECTION INSP PASSED COMMENTS Framing I Fire/Draft Stopping Energy Code/Insulation I Building Final Fire Approval: Date: Engineering Date: Approval: PW Approval: Date: Other( ): Date: To request an inspection:(952)442-7520 Paae 1 of 1 CITY OF SPRING PARK PAGE 1 BUILDING PERMIT 4349 Warren Avenue 23SP-00047 Spring Park, MN 55384 ❑ Handout Given Routed to MNSPECT Phone: 952-471-9051 Fax: 952-471-9160 ❑ Lead Handout Given SITE ADDRESS: 23 2 WEFsT Aavr I12 vE5- PID: 1)Was the home constructed before 1978?(YES❑,continue with line 2,NOntinue without completing EPA Section) 2)Will the work disturb>6 sq ft of interior painted surfaces or 220 sq ft of exterior painted surfaces?(YES Vgo to line 4,NO❑line 3) _ 3)Are there any windows being replaced?(YES)<go to line 4,NO❑continue without completing EPA Section) 4)Has this home been Certified Lead Free?(YES❑,you MUST Attach Certification Information,NO complete line 5) 5)EPA Contractor Certification Number. NAT- a 3 5S61-3 (applies to contractor only) • PROPERTY OWNER: Address: 3 2 crr, 15 rf v�- Ci State:&ff Zip: 5538 Email: T '7r ftov Go/rl Contact Name: -T,0 t�'c r l Phone: tZ-S-06 --c6 4 • CONTRACTOR: Q aoMC KK-fU(L,cGlorrS Address: ki / ��, 1"�� gib D city: vitl4 State: Zi : S�3 Phone:6,17 Fax: 4,(2-•2Z 4-`+/7-e Contractor License No: / 7 i~2- Contact Name: ,,_tc Phone:`2T)- ' Email: tc-AMA- c. m�S. Go ARCHITECT: D-riP Address: 4/C'D 8,6_1 7 1117o 2---Srr /E Cit : State: Zip: Ss-'fq Phone: 3-780 Oot,4 Fax: 3 -_2ke -F-o1.i • Email: Icy e b-PP des 6A Contact Name:i<`1EE Uvl-M9 Phone: J- &4 TYPE OF WORK: ❑New Construction ❑Deck ❑Pool ❑Re-Roof ❑Commercial V esidential ❑Change of Use ❑Retaining Wall ❑Porch ❑Re-Side EST.VALUATION OF WORK ❑Finish Basement o Demolition ❑Fence $ 3S1),0 emodel ❑Fire Sprinkler ❑Shed Square feet. ❑Addition ❑Fire Alarm e<Window/Door Replacement ❑Garage-Attached/Detach ❑Plumbing-provide detail on Page 2 #being replaced Detailed Description of Work: ❑Accessory Structure ❑Mechanical-provide detail on Page 2 ❑Misc Other L Re- Fc 'Y7 Signature of this application by the legal property owner a a licensed contractor,as the owner's representative,is required and authorizes the Zoning Administrator or designee and the Building Official or designee to enter upon the property to perform needed inspections.Entry may be without prior notice.I hereby acknowledge that 1 have read this application and state that all information is true and correct to the best of my knowledge.I further agree that all work performed will be In accordance with approved plans,specifications and conditions and to abide by at ordinances of the Municipally and the laws of the state of Minnesota regarding actions taken pursuant 10 this permit.i agree to pay all plan review fees even If 1 choose not to proceed with the work.Permit expires when work Is not c ommenced within 180 days from date of permit,Or if work Is suspended abandoned,or not Inspected for 180 days.Work beyond the scope of this permit,or work without a permit or Inspection. • will be subject to a penalty. Noise Ordinance In Effect:MONDAY-FRIDAY Before 7 a.m,and after 10 p.m.Weekends/Holidays before 7 a.m.and after 8 p.m. SIGNATURE OF APPLICA /�� DATE: <r�r C,2 PRINTED NAME: IfJAIU& This is the signature of: ❑Owner or kOwner's Representative OCCUP.TYPE: I gC-1 CONST.TYPE: N/A CODE: 2020 MRC BLDG SPRINKLED Yes/No VALUATION:$ 3 5 0, 0 0 0 . 0 0 Permit Fee: $-:20"414 WAC Charge: $ Plan Review Fee: $ l ITM Sewer&Water Hook-Up: $ State Surcharge: $ Inds. 0'D Sewer&Water Disconnect: $ Site Inspection Fee: $ Water Meter. $ S.E_C.Fee: $ Muni SE/NVA Fee: $ Investigation Fee/Other Fee: $ '2016 SAC Escrow: $2.485 Copy Charge($.25 per 8.5 x11 page) $ Other. $ Z License Chock($5)/Lead Check($5)$ TOTAL DUE: $ . O SUB-TOTAL$ Eha t a. ��. W NOTE:Commercial plans will be submitted to the Met Council Environmental Svcs Plumbing F from Pa $ � gee( Page 2) for SAC determination. Escrow payment will be required when permit Is Issued. If v Mechanical Fee from Page 2 $ after Met Council review no SAC is determined,escrow will be refunded in full. LL Special Conditions/Required Setbacks: LL O Building Approval By: DATE: 6/2 2/2 0 2 3 Printed Building Approval B . Kevin Kame rud ❑ License Verification❑ Lead Verification-Checked By: City Approval By: DATE:(p Paid:5XA,454 Date: 4PIJI41A.3 Receipt No. By: 9g4��ay City of Spring Park 4349 Warren Ave Spring Park, MN 55384 Phone (952)471-9051 SPRING PARK Fax(952)471-9160 n Lake Yinneton a Project Name: Date: 06/22/2023 Approval Status: Approved with Comments Jurisdiction: City of Spring Park Construction Type: Warren Home Restoration Inc- Mark ID: 23SP-00047 Applicant Name: Warren Applicant Phone: (612) 741-9512 Applicant Email: mark@markwarrenhomes.com Jobsite: 4232 WEST ARM DR Code: 2020 1309, Minnesota Residential Code Trades Reviewed: Building The plans and specifications,for the project named above, have been reviewed for substantial compliance with the current Minnesota State Building Code. This review is limited to the submitted scope of work; is based upon the supposition that the data on which the design is based are correct and that the necessary legal authority has been obtained to construct the project. Although every attempt has been made to identify code issues or concerns for proper and necessary change, the project designer(s), the building contractor(s) and the property owner(s) are ultimately responsible for providing complete code compliance and maintaining minimum construction standards for the safeguarding of life or limb, health, public welfare and property while constructing this project. Approval is based on the correction of all noted deficiencies and compliance with all items listed below. Any changes from these documents and/or additional information shall be submitted to the Department of Building Safety for code compliance review and approval. Written response of approval must be on site prior to implementation of such changes. The following information is related to the submitted plans/scope or as general information regarding code compliance. Compliance with the stated requirements will be verified during the construction process. All work shall be inspected. It is the responsibility of the contractor/installer to contact the Department of Building Safety, when ready to schedule an inspection, at(952)442-7520 during regular business hours. If you have any questions or concerns regarding this plan review, please contact me via telephone at (952)442-7520 or email at codereview@mnspect.com. Kevin Kamerud Plans Examiner (952) 442-7520 kkamerud@mnspect.com 4232 WEST ARM DR Page 1 City of Spring Park 4349 Warren Ave Spring Park, MN 55384 Phone (952)471-9051 SIDING PARK Fax (952) 471-9160 n Lake 31inneton a Plan Specific Items: Building:Approved with Comments-Kevin Kamerud, kkamerud@mnspect.com PLANS DATED: 6/22/2023 PLAN SHEETS REVIEWED: 7 SCOPE OF WORK: Interior remodel & new kitchen General Requirements: MN Residential Code: 1. Habitable space, hallways, bathrooms,toilet rooms, laundry rooms, and portions of basements containing these spaces shall have a ceiling height of not less than 7 feet. The required height shall be measured from the finished floor to the lowest projection from the ceiling. (MN Rule 1309. R305.1) 2. Smoke alarms shall be installed in the following locations: (MN Rule 1309.R314.3) a. In each sleeping room. b. Outside each separate sleeping area Within 21' of the bedroom doors. c. On each additional story of the dwelling, including basements and habitable attics but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. d. Smoke alarms shall not be installed within 3' horizontally of a bathroom that contains a tub or shower unless this requirement would interfere with other required placements. 3. Smoke alarms shall be interconnected. Combination alarms shall be listed in accordance with UL 217 and UL 2034. (MN Rule 1309.R314.4) 4. Carbon monoxide alarms shall be installed outside and not more than 10 feet(3048 mm)from each separate sleeping area or bedroom. Alarms shall be installed on each level containing sleeping areas or bedrooms. Alarms shall also be installed inside each bedroom where a fuel-fired appliance is present in the bedroom, or its attached bathroom. (MN Rule 1309.R315.3) 5. Carbon Monoxide alarms shall be interconnected. Combination alarms shall be listed in accordance with UL 217 and UL 2034. (MN Rule 1309.R314.4) 6. Carbon Monoxide alarms shall receive their primary power from the building wiring where such wiring is serviced from a commercial source, and where the power is interrupted, shall receive power from a battery. (MN Rule 1309.R315.6) 7. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Numbers shall be a minimum of 4 inches high with a minimum stroke width of 1/2 inch. Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole, or other sign or means shall be used to identify the structure. Address identification shall be maintained. (MN Rule 1309.R319.1) MN Energy Code: 1. All exhaust, supply, and return air ducts and plenums shall be insulated according to Table R403.2.1. (MN Rule 1322 R403.2.1) 4232 WEST ARM DR Page 2 City of Spring Park 4349 Warren Ave Spring Park, MN 55384 Phone (952)471-9051 PRING PARK Fax(952)471-9160 rn Lae Winnetonka a. Insulation is only required in the conditioned space for a distance of 3 feet from the exterior or unconditioned space. 2. Ducts, air handlers, and filter boxes shall be sealed. (MN Rule 1322 R403.2.2) 3. Building framing cavities shall not be used as ducts or plenums. (MN Rule 1322 R403.2.3) 4. Insulation for new hot water pipe with a minimum thermal resistance (R-value)of R-3 shall be applied to the following: (MN Rule 1322 R403.4.2) a. Piping larger than 3/4-inch nominal diameter. b. Piping from the water heater to kitchen outlets. c. Piping located outside the conditioned space. d. Piping from the water heater to a distribution manifold. e. Piping located under a floor slab. f. Buried piping. g. Supply and return piping in recirculation systems other than demand recirculation systems. h. Piping with run lengths greater than the maximum run lengths for the nominal pipe diameter given in Table R403.4.2. 5. A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of the permanently installed lighting fixtures shall contain only high efficacy lamps. (MN Rule 1322 R404.1) Mechanical Code Items: 1.The air removed by every mechanical exhaust system shall be discharged outdoors at a point where it will not cause a nuisance and not less than the distances specified in 501.3.1. The air shall be discharged to a location from which it cannot again be readily drawn in by a ventilating system.Air shall not be exhausted into an attic or crawl space and the exhaust system shall be equipped with a backdraft damper at the point of discharge. (MN Rule 1346.501.3) 2. The termination points of exhaust outlets and ducts discharging to the outdoors shall be located with the following minimum distances (MN Rule 1346.501.3.1) a. For all environmental air exhaust: 3 feet from property lines; 3 feet from operable openings into buildings, and 10 feet from mechanical air intakes. 3. Exhaust hood systems capable of exhausting in excess of 400 cfm (0.19 m3/s) shall be provided with makeup air at a rate approximately equal to the exhaust air rate. Such makeup air systems shall be equipped with a means of closure and shall be automatically controlled to start and operate simultaneously with the exhaust system. (MN Rule 1346.505.4) MN Fuel Gas Code:? 1. Corrugated stainless steel tubing (CSST)that is not listed with an arc-resistant jacket or coating system in accordance with ANSI LC 1/CSA 6.26. CSST gas piping systems and piping systems containing one or more segments of CSST shall be electrically continuous and bonded to the electrical service grounding electrode system or,where provided, the lightning protection grounding electrode system (MN Rule 1346.5310.2).? 2. This section applies to corrugated stainless-steel tubing (CSST)that is listed with an arc-resistant jacket or coating system in accordance with ANSI LC 1/CSA 6.26.The CSST shall be electrically continuous and bonded to an effective ground fault current path.Where any CSST component of a piping system does not have an arc-resistant jacket or coating system, the bonding requirements of Section 310.2 shall apply. Arc-resistant-jacketed CSST shall be considered to be bonded where it is connected to an appliance that is connected to the appliance grounding conductor of the circuit that supplies that appliance(MN Rule 1346.5310.3).? 4232 WEST ARM DR Page 3 City of Spring Park 4349 Warren Ave M,iA I; Spring Park, MN 55384 FM PARK Phone (952)471-9051 Fax(952)471-9160 n Lae Ninnetonka 3. Where in contact with or passing through concrete or other abrasive material, metallic piping and fittings coated with a corrosion-resistant material, sleeve, or casing shall be used. Steel pipe exposed in exterior locations shall be galvanized or coated with approved corrosion-resistant material (MN Rule 1346.5403.8).? 4. Prior to acceptance and initial operation, all piping installations shall be visually inspected and pressure tested to determine that the materials, design,fabrication and installation practices comply with the requirements of this code(MN Rule 1346.5406.1).? a. Test pressure.?The test pressure to be used shall be no less than 25 psig irrespective of design pressure (MN Rule 1346.5406.4.1).? b. Test Duration.?Test duration shall be not less than one-half hour. When testing a system in a single-family dwelling, the test duration shall be permitted to be reduced to 10 minutes with prior approval from the building official (MN Rule 1346.5406.4.2).? c.Test gauges.?Tests which utilize dial gauges shall be performed with gauges of 2 psi incrementation or less and shall have a pressure range not greater than twice the test pressure applied.The test pressure shall be within the middle 50 percent of the test?gauge pressure range (MN Rule 1346.5406.4.3).? 5. Appliances shall be provided with an approved main shutoff valve before the first branch line.The main shutoff valve shall be installed in the first available location inside the building 5 feet or less above the floor that provides ready access and shall have a permanently attached handle (MN Rule 1346.409.5.1).? 6. Piping shall be supported at intervals not exceeding the spacing specified in Table 415.1. Spacing of supports for CSST shall be in accordance with the CSST manufacturer's instructions (MN Rule 1346.5415.1).? Plumbing Code Items: 1. Prior to acceptance and initial operation, all piping installations shall be visually inspected and pressure tested to determine that the materials, design, fabrication and installation practices comply with the requirements of this code.? a. Drain/WasteNent:?? i. Must hold a uniform 5#psi for 15 minutes. (MN Rule 4714.?712.3)?? ii. Gauge increments to be .1 psi or less (MN Rule 4714.?318.2?? b. Water Lines:?? i. Minimum 50#psi for 15 Minutes(MN Rule 4714.??609.4)? ii. Pex manufacturers specifications (MN Rule 4714.??609.4))? Pex manufacturers specifications (MN Rule 4714.??609.4) 4232 WEST ARM DR Page 4 k XXk ! }. $ 4 °oA� o11 A �9 � f� o�8r �f'$3� P11 , � g ����$#� aas5��Yi$ n§$Q 5iv �' B [ Y ��� s ��4g��$a� � k tt ii p €R 2 yEy A 3 €€ {$ AAABi A i E A S E ��� � ." _SEE [ � � 3 1 � s Y� :T �F ��4 a;� t__ s ••$s� �p D:C gsS ��� M, f a a BRgjd�Ta i 3 "i u [e a $Fz$ � Jg it 8o$33_e mg $$ag3s8 j3jj $ 3 • �Fs'�A gA_ 2gqadg '�¢ $: F:o _� yg3gY S ¢ � A:yy } F€ � �qy 11 CAy��is�i. � � a; ys$ °g-3QiF°a s0 ' `gai223 �A R 3 I iI Y El ee Y J �F 7, r . _.----------' � oW� H F-] CT� F-3 ago 9 A A A JA pj :Ji!.��� A file 11 �14 9 as a H A a $ s a E d> a i Aa � � � a G a Epp z lip � $ filly �� 1? : 11 ��. .. 117FFT O'BRDEN/ RIDOUT RESID _ENCE D.F.P. 4232 w ARM DRIVE wA: aaMe PLANNING 6 DESIGN SPRING PARE, MINNESOTA WARREN - �.� K. ,P��� a K 8a 9q' nfi All 11 � I -v s.a w� _ q rrxn ?Ag3g3 pp { ________________ € ,., _ -------------- H H LTJ fill, 71 H O'HRD3N/ RIDOUT RESIDENCE o ssa a►nrwq a asw D.F.P. a•-p � 4232 A ARM DRIVE WARREN �eo�xwMPLANNING 6 DESIGN • ._ PLM1O•vq.11iY.V A M -aa SPRING PARK, MINNESOTA ue carma cr rE.-.11=1 r„u W I -aE�P6ggiPElA A 4 3 a� � sFig IA?AjRjj aP ---- _____==_..a Ali e , I ��'l� i irewa r' '$ aye..n.t. - - -----; ------------ en.m �� nex N_a ap aLMNICC �� tri 12 10 7N H1 H H LTJ H pppg �g O'HRD3N/ RIDOUT RESIDENCE / D.F.P. 4232 A ARM DRIVE 7*(WARREN _ ""M PLANNING 6 DESIGN 09 SPRING PARK, MINNESOTA ..VZ—..'a i ----------------- _ __ MM� !L'J N7 a H H Lz7 f-3 O'BRIEN/ RIDOUT RESIDENCE D.F.P U1�,I I PLAWpNO 6 DESIGN 4232 if ARM DRIVE � _ a.w e,v a.nan a K III✓ SPRING PARK MINNESOTA 6 Qa pit H3��e li. iS i °�f�€1 $a i' A$a °gs A � rnrnc'+`D till $w ?A �g q w; �� 3 9, zRi%AON P 3i N ; :PR r9 qq qd ;jasRj ,; 11 1a Ef i•Eli] IF A C ii 9D m aj ❑m❑ a❑ ❑ OMEA❑❑ ❑ ❑ mil ❑ a❑ ❑❑❑ ❑❑❑10 ❑❑ ❑❑❑ p Eli it A rRr F # fit .1ai>si �+9 � � ° ` , � � � t � ! a �� it • � s � g �� -� � �ea�; � S ! Y 92N �~ A �OA� � R y ! A• —IAR �� e Nail 1 9 a. w: A� f 'T�� SPA I JET" Is it F55 Fg5� it ww S n °n 'n G � O'RRINN RIDOUT RESIDENCE oionw.rux«wR+o°sm« D.F.P. ads I I I NOT WARREN uwuuola°Ruoeorne PLANNING 6 DESIGN 4232 11 ARM DRIVE vux�.v a rnx a ne .�....v...«.,,n,a, •,v. . + SPRING PARK, MINNESOTA + u'C0'"10 " «..... ««..• .«. <o.�A+«+ |7 [ \/ `m 7 7 / $ � % § £ . .| § 9■ � q � � � m � T'p ■ � l7 � ■ r/, , •§! jp | �` � ■ � \mo #® HIM §q j j 4 ,&=9 � | | t ;k q . ¢ � RESIDENCE :dam.. ARM Fd & DESIGN !oe�Z �oUT ss 22 D.F.P.z , a| PIT S WA ----------------------------------------------------- -------------------- ------------------- ----------------- Lj UJJILL=jj U ----------- 0 4 tF- o Im LTJ F-3 LTJ x!R, rp Jill I Mairpigilf ZIP R SA O'BRIEN/ RIDOUT. RESIDENCE D.F.P. 4232 W ARM DRIVE WARREN us�ml 'I- E SPRING PARK, bUNNESO "I p 11411ill 11 - FS 0 o PLANNING 6 DESIGN ff Payment Confirmation Payer Information: Payment Made By: Mark Warren Payment Made For: Mark Warren Email: markhwarren51@gmail.com Permit Address: 4232 West Arm Drive Address: 1161 Wayzata Blvd##96 Wayzata, MN 55391 Payment Description: Permits Payment Date: 6/29/2023 5:53:18 AM Payment Payment Confirmation Convenience Business Name Method Account Number Amount Fee Total City of Spring AMEX ****7008 98963624 $4,500.00 $132.75 $4,632.75 Park(Permits) This notice confirms that the above payment was successfully submitted to our payment processor, PSN, and is currently being processed.Thank you for using PSN. NOTE:While credit and debit cards generally are immediately approved, the transaction is not considered "paid" until the credit or debit card company has"settled"the payment which occurs most often within 24 hours. If there are any issues with your payment, PSN will send an email to the address you provided. If you would like to check the progress of this payment, log into your profile and select the Payment History option. Contact Us PSN Customer Support Submit your question and get a response within one business day. Payment Processing Powered by Payment Service Network (PSN) THIS COMMUNICATION IS INTENDED ONLY FOR THE ADDRESSEE(S)AND MAY CONTAIN INFORMATION THAT IS PRIVILEGED AND CONFIDENTIAL. YOU ARE HEREBY NOTIFIED THAT,IF YOU ARE NOT AN INTENDED RECIPIENT LISTED ABOVE,OR AN AUTHORIZED EMPLOYEE,OR AGENT OF AN ADDRESSEE OF THIS COMMUNICATION RESPONSIBLE FOR DELIVERING E-MAIL MESSAGES TO AN INTENDED RECIPIENT,ANY DISSEMINATION, DISTRIBUTION,OR REPRODUCTION OF THIS COMMUNICATION(INCLUDING ANY ATTACHMENTS HERETO)IS STRICTLY PROHIBITED.IF YOU HAVE RECEIVED THIS COMMUNICATION IN ERROR,PLEASE NOTIFY US IMMEDIATELY BY A REPLY E-MAIL ADDRESSED TO THE SENDER AND PERMANENTLY DELETE THE ORIGINAL E-MAIL COMMUNICATION AND ANY ATTACHMENTS FROM ALL STORAGE DEVICES WITHOUT MAKING OR OTHERWISE RETAINING A COPY. Payment Confirmation Payer Information: Payment Made By: Mark Warren Payment Made For: Mark Warren Email: markhwarren51 @gmail.com Permit Address: 4232 West Arm Drive Address: 1161 Wayzata Blvd##96 Wayzata, MN 55391 Payment Description: Permits Payment Date: 6/29/2023 5:55:28 AM Business Name Payment Payment Confirmation Amount Convenience Total Method Account Number Fee City of Spring Park AMEX ****7008 55564639 $712.55 $21.02 $733.57 (Permits) This notice confirms that the above payment was successfully submitted to our payment processor, PSN, and is currently being processed.Thank you for using PSN. NOTE:While credit and debit cards generally are immediately approved, the transaction is not considered "paid" until the credit or debit card company has"settled"the payment which occurs most often within 24 hours. If there are any issues with your payment, PSN will send an email to the address you provided. If you would like to check the progress of this payment, log into your profile and select the Payment History option. Contact Us PSN Customer Support Submit your question and get a response within one business day. Payment Processing Powered by Payment Service Network (PSN) THIS COMMUNICATION IS INTENDED ONLY FOR THE ADDRESSEE(S)AND MAY CONTAIN INFORMATION THAT IS PRIVILEGED AND CONFIDENTIAL. YOU ARE HEREBY NOTIFIED THAT,IF YOU ARE NOT AN INTENDED RECIPIENT LISTED ABOVE,OR AN AUTHORIZED EMPLOYEE,OR AGENT OF AN ADDRESSEE OF THIS COMMUNICATION RESPONSIBLE FOR DELIVERING E-MAIL MESSAGES TO AN INTENDED RECIPIENT,ANY DISSEMINATION, DISTRIBUTION,OR REPRODUCTION OF THIS COMMUNICATION(INCLUDING ANY ATTACHMENTS HERETO)IS STRICTLY PROHIBITED.IF YOU HAVE RECEIVED THIS COMMUNICATION IN ERROR,PLEASE NOTIFY US IMMEDIATELY BY A REPLY E-MAIL ADDRESSED TO THE SENDER AND PERMANENTLY DELETE THE ORIGINAL E-MAIL COMMUNICATION AND ANY ATTACHMENTS FROM ALL STORAGE DEVICES WITHOUT MAKING OR OTHERWISE RETAINING A COPY. RECEIPT City of Spring Park 14'' 4349 Warren Ave, Spring Park, MN 55384 (952)471-9051 paQa 23SP-00047 I Repair/Remodel/Alteration (Residential) On Lake Winnetonka Receipt Number:202 Payment Amount: $5,212.55 June 29,2023 Transaction Method Payer Cashier Reference Number Credit Card Warren Homes Jamie Hoffman 98963624,55564639 Comments Assessed Fee Items Fee items being paid by this payment Date Fee Item Account Code Assessed Amount Paid Balance Due 06/22/23 State Surcharge $175.00 $175.00 $0.00 06/22/23 Residential Building Permit $3,047.00 $3,047.00 $0.00 06/22/23 Contractor License Look-up $5.00 $5.00 $0.00 06/22/23 Lead Certification Look-up $5.00 $5.00 $0.00 06/22/23 Residential Plan Review $1,980.55 $1,980.55 $0.00 Totals. $5,212.55 $5,212.55 Previous Payments $0.00 Remaining Balance Due $0.00 Permit Info Property Address Property Owner Property Owner Address Valuation 4232 WEST ARM DR JUDITH H O'BRIEN TRUST 4232 WEST ARM DR $350,000.00 Spring Park, MN 55384 Spring Park, MN 55384 Description of Work Interior remodel&window replacement RECEIPT City of Spring Paris 4349 Warren Ave, Spring Park, MN 55384 (952)471-9051 SPRING PR007 23SP-00047 I Repair/Remodel/Alteration(Residential) On Lakg 911innetonkq