Loading...
Permits - Permit# 24SP-00028 - 4012 Shoreline Drive - 5/1/2024I t. City of Spring Park Mechanical Commercial �+L _ 4349 - - - - - - 24SP-00028 INS r-r9. Phone:(952) 471-9051 Fax: (952) 471-9160 ru;.�...F,...C„ For Inspections: (952) 442-7520 Dabs Issued: 05/01/2024 Property Owner: CAPITAL ESTATES LLC Expiration Date: 10/28/2024 Mailing Address: 10876 JERSEY CIR N Job Site Address: 4012 SHORELINE DRIVE, SPRING PARK, MN 55384 BROOKLYN PARK, MN 55445 Category: Commercial Miscellaneous Phone: Permit Type: Mechanical (Commercial) Email: Valuation: $6,666.00 Description of Work: Furnace & A/C Replacement "Like for Like" Subdivision: Required Setbacks: Parcel I D: 17-117-23-33-0123-4012 Filing: I T Lot: Actual Setbacks: Block: Total Sq Ft: Contractors: Fee [Isms Amount Primary J&S Mechanical Inc (651) 235-2094 State Surcharge $ 3.33 Commercial Mechanical Permit $ 191.25 Commercial Mechanical Plan Review $124.31 Total Fees: $ 318.89 NOTICE Signature of Applicant/Date Building Department Signature/Date 05/01/2024 MUST BE POSTED ON JOB SITE 4 INSPECTION CARD J - - City of Spring Park SPRING PARK On Lake9iiinneton4 4349 Warren Ave, Spring Park, MN 55384 POST THIS CARD IN A SAFE CONSPICUOUS LOCATION. PLEASE DO NOT REMOVE THIS NOTICE UNTIL ALL REQUIRED NSPEC IONS ARE MADE AND SIGNED OFF BY THE APPROPRIATE Ml1HORITYAND THE BUILDM IS APPROVED FOR OCCUPANCY. STAMPED APPROVED PLANS MLMT BE AVAILABLE ON THE.IOBUM Mechanical APPLICATION NO.: 24SP-00028 TYPE: (Commercial) ISSUED DATE: 05/01/2024 EXPIRATION DATE: 1012812O24 PROJECT ADDRESS: 4012 SHORELINE DRIVE, SPRING PARK, MN 55384 PARCEL NO17-11.: 33-0i23- 3- 4012 OWNER: CAPITAL ESTATES LLC CONTRACTOR: J&S Mechanical Inc CONTRACTOR PHONE: (651) 235-2094 DESCRIPTION OF WORK: Furnace & A/C Replacement "Like for Like" CONSTRUCTION TYPE: OCCUPANT LOAD: DATE DATE INSPECTION INSP PASSED COMMENTS INSPECTION INSP PASSED COMMENTS Mechanical Rough -In Reports Mechanical Final Fire Approval: Date: Engineering Approval: PW Approval: Date: Other To request an Inspection: (952) 442-7520 Date: Date: Page 1 of 1 City of Spring Park 4349 Warren Ave. Spring Park, MN 55384 COMMERCIAL MECHANICAL PERMIT APPLICATION City: 952-471-9051 MNSPECT: 952-442-7520 Permit Number- ? 0- Job Address D Owner's Phone �� �O! 0 Owner's Name j', 4C Business Name .���4iI, _ Lc� �" Owner's Address _fieg. fvk-, City/State/Zip Mechanical Contractor _� d'�.�, c� / �„ r, Phone Address i,eq, City/State/Zip State Bond No. C1 Gas Fitters License No. CFIECK TYPE OF WORK: ❑ New US I /k3C dq) Furnace Boiler Air Cond Wall Heater Construction ❑ Addition ❑ Alteration )V Replacement y1�7� L>ay�j �In�Flo�orHeat �Alrxch Fireplace Exhaust Fan Unit II 1 Unit Heater Equipment Efficiency . . VALUATION OF WORK $ VALUATION APPROVED $ Hood 11 1 Make -Up Air I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other state or local law regulating construction or the performance of construction. I agree to pay all plan review fees even if 1 choose not to proceed with the work I certify all taxes and Municipal flees owed in connection with this peity are current. b i Applicant's Signature Date OFFICE USE ONLY Permit Fee it is / . a5 Code Review ....................... ISILI. 31 State Surchaa ..........s..... 3 Other ....X..�Ai-S C Total Permit Charge 54g=L, ta'7 Plans checked by: Date: PARK Project Name: Date: Jurisdiction: ID: Applicant Phone: Jobsite: Code: Reviewed: 04/30/2024 City of Spring Park 24SP-00028 (651) 235-2094 4012 SHORELINE DRIVE City of Spring Park 4349 Warren Ave Spring Park, MN 55384 Phone (952) 471-9051 Fax (952) 471-9160 Approval Status: Approved As Is Construction Type: Applicant Name: J & S Mechanical - Eric Applicant Email: jsmechanicalinc@yahoo.com 20201300, Minnesota Building Code Administration; 20201305, Minnesota Building Code Mechanical The plans and specifications, for the project named above, have been reviewed for substantial compliance with the current Minnesota State Building Code. This review is limited to the submitted scope of work; is based upon the supposition that the data on which the design is based are correct and that the necessary legal authority has been obtained to construct the project. Although every attempt has been made to identify code issues or concerns for proper and necessary change, the project designer(s), the building contractor(s) and the property owner(s) are ultimately responsible for providing complete code compliance and maintaining minimum construction standards for the safeguarding of life or limb, health, public welfare and property while constructing this project. Approval is based on the correction of all noted deficiencies and compliance with all items listed below. Any oranges from these documents and/or additional information shall be submitted to the Department of Building Safety for code compliance review and approval. Written response of approval must be on site prior to implementation of such changes. The following information is related to the submitted plans/scope or as general information regarding code compliance. Compliance with the stated requirements will be verified during the construction process. All work shall be inspected. It is the responsibility of the contractor/installer to contact the Department of Building Safety, when ready to schedule an inspection, at (952) 442-7520 during regular business hours. If you have any questions or concerns regarding this plan review, please contact me via telephone at (952) 442-7520 or email at codereview@mnspect.com. Michael Hauan Plans Examiner (952) 442-7520 mhauan@mnspect.com 4012 SHORELINE DRIVE Page 1 PARK City of Spring Park 4349 Warren Ave Spring Park, MN 55384 Phone (952) 471-9051 Fax (952) 471-9160 Mechanical: Approved As Is - Michael Hauan, mhauan@bmnspect.00m Scope: Replace Furnace, AIC "Like for LIW Approval is based on the compliance with 011tems listed below. Comments: 1. Address shall be posted and visible from the fronting street. 2. Heating and cooling equipment shall be sized no more than 10 percent greater than the calculated peak heating and cooling loads. (MEC Subsection C403.2.2) 3. Any existing gravity load -carrying structural element for which an alteration causes an increase in design dead, live, or snow load, including snow drift effect, that increase the demand -capacity ratio to more than 105 percent, shall be replaced or altered as needed to carry the gravity loads, under a separate building permit. (MCCEB 503.3) 4. Carbon Monoxide Alarms: i. Carbon monoxide alarms shall be installed in new and existing rooms containing a fuel -burning appliance that is utilized to control environmental conditions and produces carbon monoxide during operation. (MFGC Subsection 311.1) ii. Carbon monoxide alarms shall comply with MFGC Subsection 311.2 5. Equipment Installation: 1. An unobstructed passageway measuring not less than 36 inches wide and 80 inches in height shall be provided for appliances within rooms. (MMC Subsection 306.2) ii. Guards shall be provided where various components that require service and roof hatch openings are located within 10 feet (3048 mm) of a roof edge. (MMC Subsection 304.11) iii. Where components that require service are installed on a roof having a slope of three units vertical in 12 units horizontal or greater and having an edge more than 30 inches above grade at such edge, a level platform shall be provided on each side of the component to which access is required for service, repair, or maintenance. (MMC Subsection 306.5.1) 6. Chimneys and Vents: 1. Venting components for appliances utilizing a power exhaust system shall have sealed joints. (MFGC Subsection 501.10) ii. Gas vents (type B, B-W, & L) shall be installed and terminate in accordance with MFGC Subsection 503.6. Single wall metal pipe vents shall be installed and terminate in accordance with MFGC Subsection 503.7. Mechanical vent systems shall be installed and terminate in accordance with MFGC Subsection 503.8. 7. Gas Piping: i. Gas piping shall be sized in compliance with MFGC section 402. ii. Corrugated stainless steel tubing (CSST) gas piping systems shall be bonded in accordance with MFGC Subsection 310.2 or 310.3 as applicable. iii. Gas piping exposed to corrosive action shall be protected in an approved manner. (MFGC Subsection 404.11) 4012 SHORELINE DRIVE Page 2 A_Y_ PARK City of Spring Park 4349 Warren Ave Spring Park, MN 55384 Phone (952) 471-9051 Fax (952) 471-9160 iv. Steel gas piping sizes % inch shall be supported at intervals not greater than 6 feet, % inch and 1 inch shall be supported at intervals of not greater than 8 feet, and piping sizes 1'/4 inch and larger shall be supported at intervals not greater than 10 feet. Refer to MFGC Table 415.1 of MFGC section 415 for support information for other sizes and/or materials. v. Copper gas tubing sizes '/z inch shall be supported at intervals not greater than 4 feet; ? inch and % inch shall be supported at intervals of not greater than 6 feet. Refer to MFGC Table 415.1 of MFGC section 415 for support information for other sizes and/or materials. A. Gas piping shall be elevated no less than 3%: inches above the ground/roof surface and protected from physical damage. (MFGC Subsection 404.9) vii. A minimum 3-inch sediment trap shall be installed prior to the regulator. If a tee fitting is used, it shall provide a 90-degree change in direction of gas flow. (MFGC Subsection 408.4) viii. Each appliance shall be provided with a shutoff valve in the gas line, separate from the appliance and no further than 6 feet from the appliance, or located within 50 feet of the appliance when located at a manifold. (MFGC Subsection 409.5) ix. All gas piping shall be tested and Inspected In compliance with MFGC section 406. a. Test Pressure:1 to operating pressure but not less than 25 psig b. Duration: thirty (30) minutes c. Gauge: 2 psig increments d. Test Pressure: Shall be within the middle 50 percent of the gauge pressure range x. A final gas piping system, appliance and equipment leakage test shall be conducted in the presence of the Inspector at the final Inspection. (MFGC Subsection 406.6) 8. Refrigerant Piping: i. Any portion of a refrigeration system that is subject to physical damage shall be protected in an approved manner. (MMC Subsection 1101.3) ii. Refrigerant circuit access ports located outdoors shall be fitted with locking -type tamper -resistant caps or shall be otherwise secured to prevent unauthorized access. (MMC Subsection 1101.10) ill. Refrigerant piping shall comply with MMC section 1107. iv. Refrigerant piping shall be of an approved material in accordance with MMC Subsection 1107.5. v. Refrigerant pipe joints erected on the premises shall be exposed to visual inspection prior to being covered or enclosed. (MMC Subsection 1107.7) vi. Piping insulation shall comply with Table C403.11.3. (MEC Subsection C403.11.3) vii. Piping insulation shall be protected by aluminum, sheet metal, painted canvas, plastic cover or other approved material. Cellular foam shall be protected by a previous identified method or painted with a coating that is water -retardant and shields against solar degradation. Adhesive tape shall not be permitted. (MEC Subsection C403.11.3.1) 9. Condensate: L Condensate from fuel-buming appliances shall discharge to an approved plumbing fixture via approved corrosion -resistant piping at a minimum slope of 1% slope. (MMC Subsection 307.1) ii. Condensate drain systems shall be provided for appliances containing evaporators or cooling coils. (MMC 4012 SHORELINE DRIVE Page 3 City of Spring Park 4349 Warren Ave Spring Park, MN 55384 Phone (952) 471-9051 Fax (952) 471-9160 section 307.2) iii. Condensate drain lines shall not be less than'/ -inch internal diameter. (MMC section 307.2.2) 4012 SHORELINE DRIVE Page 4 RECEIPT City c f Spring Park 4349 Warren Ave, Spring Park, MN 55384 (952) 471-9051 24SP-00028 i Mechanical (Commercial) Payment Amount: $318.89 Transaction Method Payer Check JS Mechanical Comments Assessed Fee Items Fee items being paid by this payment SPRIIL\� c, =AR! On Lah Winnetonky Receipt Number: 296 Cashier Reference Number Jamie Hoffman 4658 May 1, 2024 AssessBd Fee Item ACCount Code Assessed Amount Paid Balance Due On 04/30/24 State Surcharge $3.33 $3.33 $0.00 04/30/24 Commercial Mechanical Plan Review $124.31 $124.31 $0.00 04/30/24 Commercial Mechanical Permit $191.25 $191.25 $0.00 TOM' $318.89 $318.89 Application Info Property Address 4012 SHORELINE DRIVE SPRING PARK, MN 55384 Description of Work Previous Payments $0.00 Remaining Balance Due $0.00 Property Owner Property Owner Address Valuation CAPITAL ESTATES LLC 10876 JERSEY CIR N $6,666.00 BROOKLYN PARK, MN 55445 Furnace & A/C Replacement "Like for Like"