Permits - Permit# 24SP-00026 - 4016 Shoreline Drive - 5/1/2024City of Spring Park Mechanical (Commercial)
[�.T.� ,,
4349 Warren Ave, Spring Park, MN 55384
Phone:(952) 471-9051 Fax: (952) 471-9160
For Inspections: (952) "2-7520
24SP-00026
Date Issued: 05/01/2024
Property Owner: Water Carrier LLC
Expiration Date: 10/28/2024
Mailing Address: 3260 Carriage Druve
Job Site Address: 4016 SHORELINE DR, SPRING
PARK, MN 55384
Category: Commercial Miscellaneous
Permit Type: Mechanical (Commercial)
Valuation: $6,666.00
Medina, MN 55340
Phone: (612) 940-0405
Email: randall@skaar.com
Description of Work:
Furnace & AIC Replacement "Like for Like"
Subdivision:
Required Setbacks:
Parcel ID: 1711723330123-4016
Filing:
Lot:
Actual Setbacks:
Block:
Total Sq Ft:
Contractors:
Fee Items
Amount
Primary J&S Mechanical Inc (651) 235-2094
State Surcharge
$ 3.33
Commercial Mechanical Permit
$191.25
Commercial Mechanical Plan Review
$124.31
Total Fees:
$ 318.89
NOTICE
Signature of ApplicantlDate
Building Department Signature/Date
05/01/2024
MUST BE POSTED ON JOB SITE
* iz: z INSPECTION CARD
City of Spring Paris
SPRING PARK
Off LckS5tinmeta(g 4349 Warren Ave, Spring Park, M" 155384
POST THIS CARD IN A SAFE OONSPICUOUS LOCATION. PLEASE DO NOT REMOVE THIS NOTICE UNTIL ALL REQUIRED INSPECTIONS ARE MADE ADD SIGNED OFF BY THE APPROPRIATE
AUFMORITYAND THE BUILDING IS APPROVED FOR OCCUPANCY. STAMPED APPROVED PLANS MUST BE AVAILABLE ON THE JOBSITE.
APPLICATION NO.: 24SP-00026 TYPE: Mechanical
(Carnmerclal) ISSUED DATE: 05/01/2024 EXPIRATION DATE: 10/28/2024
PROJECT ADDRESS: 4016 SHORELINE DR, SPRING PARK, MN 55384 1711723330
PARCEL NO.: 123-4016
OWNER: Water Carrier LLC CONTRACTOR: J&S Mechanical Inc CONTRACTOR PHONE: (651) 235-2094
DESCRIPTION OF WORK: Furnace & AIC Replacement "Like for Like"
CONSTRUCTION TYPE: OCCUPANT LOAD:
DATE DATE
INSPECTION INSP PASSED COMMENTS INSPECTION INSP PASSED COMMENTS
Mechanical Rough -In Reports
Mechanical Final
Fire Approval:
PW Approval:
To request an Inspection: (M 442 75M
Date: Engineering Date:
Approval:
Date: Other ( }: Date:
Page 1 of 1
Apr,
PARK
Project Name:
City of Spring Park
4349 Warren Ave
Spring Park, MN 55384
Phone (952) 471-9051
Fax (952) 471-9160
Date:
04/30/2024
Approval Status: Approved As Is
Jurisdiction:
City of Spring Park
Construction Type:
ID:
24SP-00026
Applicant Name: J & S Mechanical
Applicant Phone:
(651) 235-2094
Applicant Email: jsmechanicalinc@yahoo.com
Jobslte:
4016 SHORELINE DR
Code:
20201300, Minnesota Building Code Administration; 20201305, Minnesota Building Code
Reviewed:
Mechanical
The plans and specifications, for the project named above, have been reviewed for substantial compliance with the
current Minnesota State Building Code. This review is limited to the submitted scope of work; is based upon the
supposition that the data on which the design is based are correct and that the necessary legal authority has been
obtained to construct the project. Although every attempt has been made to identify code issues or concerns for proper
and necessary change, the project designer(s), the building contractor(s) and the property owner(s) are ultimately
responsible for providing complete code compliance and maintaining minimum construction standards for the
safeguarding of life or limb, health, public welfare and property while constructing this project.
Approval is based on the correction of all noted deficiencies and compliance with all items listed below. Any changes from
these documents and/or additional information shall be submitted to the Department of Building Safety for code
compliance review and approval. Written response of approval must be on site prior to implementation of such changes.
The following information is related to the submitted plans/scope or as general information regarding code compliance.
Compliance with the stated requirements will be verified during the construction process.
All work shall be inspected. It is the responsibility of the contractorrinstaller to contact the Department of Building Safety,
when ready to schedule an inspection, at (952) 442-7520 during regular business hours.
If you have any questions or concerns regarding this plan review, please contact me via telephone at (952) 442-7520 or
email at codereview@mnspect.com.
Michael Hauen
Plans Examiner
(952) 442-7520
mhauan@mnspect.com
4016 SHORELINE DR Page 1
.or
ftii l
Plan Sp% fic Items:,
Mechanical: Approved As Is - Michael Hauen, mhauan@mn spect oom
Scope: Replace Furnace, A/C "Like for Like"
Approval Is based on the compliance with aff items listed below:
Comments:
1. Address shall be posted and visible from the fronting street.
City of Spring Park
4349 Warren Ave
Spring Park, MN 55384
Phone (952) 471-9051
Fax (952) 471-9160
2. Heating and cooling equipment shall be sized no more than 10 percent greater than the calculated peak heating
and cooling loads. (MEC Subsection C403.2.2)
3. Any existing gravity load -carrying structural element for which an alteration causes an increase in design dead,
live, or snow load, including snow drift effect, that increase the demand -capacity ratio to more than 105 percent,
shall be replaced or altered as needed to carry the gravity loads, under a separate building permit. (MCCEB
503.3)
4. Carbon Monoxide Alarms:
I. Carbon monoxide alarms shall be installed in new and existing rooms containing a fuel -burning appliance
that is utilized to control environmental conditions and produces carbon monoxide during operation. (MFGC
Subsection 311.1)
ii. Carbon monoxide alarms shall comply with MFGC Subsection 311.2
5. Equipment Installation:
An unobstructed passage way measuring not less than 36 inches wide and 80 inches in height shall be
provided for appliances within rooms. (MMC Subsection 306.2)
Guards shall be provided where various components that require service and roof hatch openings are
located within 10 feet (3048 mm) of a roof edge. (MMC Subsection 304.11)
ill. Where components that require service are installed on a roof having a slope of three units vertical in 12
units horizontal or greater and having an edge more than 30 inches above grade at such edge, a level
platform shall be provided on each side of the component to which access is required for service, repair, or
maintenance. (MMC Subsection 306.5.1)
6. Chimneys and Vents:
i. Venting components for appliances utilizing a power exhaust system shall have sealed joints. (MFGC
Subsection 501.10)
!L Gas vents (type B, B-W, & L) shall be installed and terminate in accordance with MFGC Subsection 503.6.
Single wall metal pipe vents shall be installed and terminate in accordance with MFGC Subsection 503.7.
Mechanical vent systems shall be installed and terminate in accordance with MFGC Subsection 503.8.
7. Gas Piping:
L Gas piping shall be sized in compliance with MFGC section 402.
ii. Corrugated stainless steel tubing (CSST) gas piping systems shall be bonded in accordance with MFGC
Subsection 310.2 or 310.3 as applicable.
iii. Gas piping exposed to corrosive action shall be protected in an approved manner. (MFGC Subsection
404.11)
4016 SHORELINE DR Page 2
AW
PAR f�
City of Spring Park
4349 Warren Ave
Spring Park, MN 55384
Phone (952) 471-9051
Fax (952) 471-9160
iv. Steel gas piping sizes'/z inch shall be supported at intervals not greater than 6 feet,'/ inch and 1 inch shall
be supported at intervals of not greater than 8 feet, and piping sizes 1'/ inch and larger shall be supported
at intervals not greater than 10 feet. Refer to MFGC Table 415.1 of MFGC section 415 for support
information for other sizes and/or materials.
V. Copper gas tubing sizes % inch shall be supported at intervals not greater than 4 feet;? inch and'/. inch
shall be supported at intervals of not greater than 6 feet. Refer to MFGC Table 415.1 of MFGC section 415
for support information for other sizes and/or materials.
vi. Gas piping shall be elevated no less than 3% inches above the ground/roof surface and protected from
physical damage. (MFGC Subsection 404.9)
vii. A minimum 3-inch sediment trap shall be installed prior to the regulator. If a tee fitting is used, it shall
provide a 90-degree change in direction of gas flow. (MFGC Subsection 408.4)
viii. Each appliance shall be provided with a shutoff valve in the gas line, separate from the appliance and no
further than 6 feet from the appliance, or located within 50 feet of the appliance when located at a manifold.
(MFGC Subsection 409.5)
ix. All gas piping shall be tested and Inspected in compliance with MFGC section 406.
a. Test Pressure: 1 % to operating pressure but not less than 25 psig
b. Duration: thirty (30) minutes
c. Gauge: 2 psig Increments
d. Test Pressure: Shall be within the middle 50 percent of the gauge pressure range
x. A final gas piping system, appliance and equipment leakage test shall be conducted In the presence of the
inspector at the final inspection. (MFGC Subsection 406.6)
8. Refrigerant Piping:
i. Any portion of a refrigeration system that is subject to physical damage shall be protected in an approved
manner. (MMC Subsection 1101.3)
ii. Refrigerant circuit access ports located outdoors shall be fitted with locking -type tamper -resistant caps or
shall be otherwise secured to prevent unauthorized access. (MMC Subsection 1101.10)
M. Refrigerant piping shall comply with MMC section 1107.
iv. Refrigerant piping shall be of an approved material in accordance with MMC Subsection 1107.5.
v. Refrigerant pipe joints erected on the premises shall be exposed to visual inspection prior to being covered
or enclosed. (MMC Subsection 1107.7)
vi. Piping insulation shall comply with Table C403.11.3. (MEC Subsection C403.11.3)
vii. Piping insulation shall be protected by aluminum, sheet metal, painted canvas, plastic cover or other
approved material. Cellular foam shall be protected by a previous identified method or painted with a
coating that is water -retardant and shields against solar degradation. Adhesive tape shall not be permitted.
(MEC Subsection C403.11.3.1)
9. Condensate:
i. Condensate from fuel-buming appliances shall discharge to an approved plumbing fixture via approved
corrosion -resistant piping at a minimum slope of 1% slope. (MMC Subsection 307.1)
ii. Condensate drain systems shall be provided for appliances containing evaporators or cooling coils. (MMC
4016 SHORELINE DR Page 3
PRING PART
$ e Minnetonka
section 307.2)
City of Spring Park
4349 Warren Ave
Spring Park, MN 55384
Phone (952) 471-9051
Fax (952) 471-9160
Condensate drain lines shall not be less than %-inch internal diameter. (MMC section 307.2.2)
4016 SHORELINE DR Page 4
City of Spring Park
4349 Warren Ave.
Spring Park, MN 55384
City: 952-471-9051 MNSPI
COMMERCIAL MECHANICAL
PERMIT APPLICATION
Permit Number• in Qos7
2�
Job Address �0 ;"'�W Owner's Phone
Owner's Name /, C Business Name J S
Owner's Address i eq. Air City/State/Zip
Mechanical Contractor % C� / �'r, Phone �� � � 2l957T/
Address P-e). �,? City/State/Zip �, 11fa ff j � f
State Bond No. o cif Gas Fitters License No.
CHECK TYPE OF WORK: ❑ New Construction ❑ Addition ❑ Alteration
vs �4:�zI/k3C&?)yaj�Fftj�,?
Equipment Efficiency
0 Replacement
Mfg. &
System Model Equipment Rated
Tag(s) Type
Heating
Rated
Minimum Rated
Cooling
Rated
Minimum Econ. Min.
No Capacity
Efficierjcy
Efficiency Capacity
Efficiency
Efficiency Efficiency
gheori, rn l�p�J
m e
D
y
M2 2 fir,
VALUATION OF WORK $��
VALUATION APPROVED $
I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and
ordinances governing this.type of work will be complied with whether specified herein or not. The granting of a permit does not presume
to give authority to`vibote or cancel the provisions of any other state or local law regulating construction or the performance of
construction. I agree to pdy�all plan review fees even if I choose not to proceed with the work. I certify all taxes and Municipal fees owed
In connection with this party are current.
Applicant's Signature Date
Permit Fee 19/ . ZA5
Code Review ....................... 9 . S t
State Surchake ........... V.....
Other ....X.
Total Permit Charee 5g9:;&_6
OFFICE USE ONLY
Plans checked by:
Date:
RECEIPT
City of Spring Park
4349 Warren Ave, Spring Park, MN 55384
(952)471-9051
24SP-00026 I Mechanical (Commercial)
Payment Amount: $318.89
Transaction Method Payer
Check JS Mechanical
Comments
Assessed Fee Items
SPI � j!-. UZ
On LakF Winnetoog
Receipt Number: 294
Cashier Reference Number
Jamie Hoffman 4658
May 1, 2024
Fee items being paid by this payment
Assessed Fee Item
Account Code Assessed Amount Paid Balance Due
04/30/24 State Surcharge
$3.33 $3.33 $0.00
04/30/24 Commercial Mechanical Plan Review $124.31 $124.31 $0.00
04/30/24 Commerrial MPr_haniral permit
Application Irdo
Property Address Property Owner
4016 SHORELINE DR Water Carrier LLC
SPRING PARK, MN 55384
Description of Work
Furnace & A/C Replacement "Like for Like"
$191.25 $191.25 $0.00
Tom $318.89 $318.89
Previous Payme ins $0.00
Remaining Balance Due $0.00
Property Owner Address Valuation
3260 Carriage Druve $6,666.00
Medina, MN 55340