Loading...
Permits - Permit# 24SP-00080 - 4068 Sunset Drive - 9/23/2024City of Spring Park Gas Line OnlyCommercial 4349 Warren Ave, Spring Park, MN 55384 PR1�IiG PARK 24SP-00080 Winneta Phone:(952) 471-9051 Fax: (952) 471-9160 La For Inspections: (952) 442-7520 Date Issued: 09/23/2024 Property Owner: SEASONAL INVESTMENTS LLC/CLIFF Expiration Date: 03/22/2025 ROCKVAM Job Site Address: 4068 SUNSET DRIVE, SPRING PARK, Mailing Address: 4068 SUNSET DR MN 55384 Category: Commercial Miscellaneous SPRING PARK, MN 55384 Permit Type: Gas Line Only (Commercial) Phone: (612) 865-4641 Valuation: $1,298.00 Email: Description of Work: New gas line for generator. Subdivision: Required Setbacks: Parcel ID: 1811723440005 Filing: Lot: Actual Setbacks: Block: Total Sq Ft: Contractors: Fee Items Amount Primary MIDWEST ELECTRIC AND GENERATOR State Surcharge $ 0.65 INC (612) 284-1550 Commercial Gas Line Only $ 78.50 Commercial Gas Line Only Plan Review $ 51.03 Total Fees: $130.18 NOTICE Signature of Applicant/Date Building Department Signature/Date 09/23/2024 MUST BE POSTED ON JOB SITE INSPECTION CARD �3 City of Spring Park On Lao Minnetonka 4349 Warren Ave, Spring Paris, MN 55384 POST THIS CARD IN A SAFE CONSPICUOUS LOCATION. PLEASE DO NOT REMOVE YM NcrnCE LKTIL ALL REGMED INSPECTIONS ARE MADE AND MWED OFF BY THE APPROPRIATE AUTHORFTY AND THE BUILDING 18 APPROVED FOR OCCUPANCY. STAMPED APPROVED PLANS MUST BE AVAILABLE ON THE JOBSRE. APPLICATION NO.: 245P-00080 TYPE: Gas Line Only (Commercial) ISSUED DATE: 09/23/2024 EXPIRATION DATE: 03I2W025 PROJECTADDRESS: 4068 SUNSET DRIVE, SPRING PARK, MN 55384 1811723440 PARCEL NO.: 005 SEASONAL INVESTMENTS MIDWEST ELECTRIC AND OWNER: LLC/CLIFF ROCKVAM CONTRACTOR: GENERATOR INC CONTRACTOR PHONE: (612) 284-1550 DESCRIPTION OF WORK: New gas line for generator. CONSTRUCTION TYPE: OCCUPANT LOAD: DATE INSPECTION INSP PASSED COMMENTS Mechanical Rough -In (U.G. R.I prior to covering gas piping) Mechanical Final Fire Approval: DATE INSPECTION INSP PASSED COMMENTS Gas Line Air Test Date: Engineering Approval: PW Approval: Date: _ Other To request an Inspection: (952) 442-7520 Date: )= Date: Page 1 of 1 The field copy of these plans must be kept on -site and made available to inspector during all inspections. To schedule inspections call (952) 442-7520 Please have the permit number and street address ready at the time of the call. Read all attached materials. Everyone performing work to which the code is applicable shall comply with the code. Plan Revisions All construction shall Comply with the approved Lan Plan revisions will not be reviewed in the field without prior approval from the Building Official. Submit all plan revisions to the Department of Building Safety for review, prior to their construction. REQUIRED INSPECTIONS: -Underground Rough -in prior to cover gas piping. -Gas pipe air test-25# for 30 minutes -Final-after gas line has been connected at both ends, valve(s) have been installed, and project is complete. NOTICE Plan review was done in accordance with the current Minnesota Building Code. Plan review does not waive any additional code compliance issues found on site. REFER TO APPROVAL LETTER FOR ADDITONAL COMMENTS AND REQUIREMENTS SCOPE OF WORK: Installing gas line from gas meter at the exterior of the building to the generator located adjacent to the building. Reviewed for Code Compliance This review is limited to the submitted scope of work, is based upon the supposition that the plan accurately depicts the intended construction and end -use, that the necessary legal authority has been obtained to construct the project and work is subject to code compliance and field inspection during construction. BY: 7mn Kraut Type of Construction: Na Date: 9M,12024 Occupancy Classification: nla Permit #: 24sP-00060 Code Edition: 2020 MN State Fuel Gas Code 4068 Sunset Drive, Spring Park, MN REVIEWED FOR CODE COMPLIANCE INSPECTOR NOTE: Gas line material, length, and Generator BTUs weren't provided during the permit application process. Use tables attached to this approved plan to verify the correct gas piping size has been installed based on the material, the distance from the meter to the generator, and the BTUs of the generator. 4068 Sunset Drive, Spring Park, MN 14 REVIEWED FOR CODE COMPLIANCE 100943272 TABLE 402,4(22) POLYETHYLENE PLASTIC PIPE GAS PIPING INSTALLATIONS of Natural rfffUrf2.0 psi rtffun psi pec rfv0.60 —1 01. 1 Hl" — �0.4 Run, 1 1007= JU4,5 mm, t Pound Per square inch — 6.895 kPa, 1-inch water column = 0.2489 kPa, 1 British thermal unit per hour — 0.2931 W, I cubic foot per hour = 0.0283 m'/h, 1 degree = 0.01745 Tad. Note: Table entries have been rounded to three significant digits. 2020 MINNESOTA FUEL GAS CODE 49 cuPrrighl B wza ICC &ASHRAE. ALL RIGH7i RE;ERVED. Aecnred 477n Krause [daaueegnuupea.mmA f-1 Order Nrnnbernuowzzn ao Aug 1e, zau rz:zx PM {PP77 Pun 1 m Ll.—Agreement .4h IOC k ASHRAE. No (..her repradunien, no 100913272 TABLE 4024(18) CORRUGATED STAINLESS STEEL TUBING (CSST) GAS PIPING INSTALLATIONS ura InW nsssun Pressure Drop 11.0 pal Dec e TUBE 81ZE Flow - (EHD} Designation 1J 15 19 19 23 25 1 30 1 31 1 37 1 39 46 4a 60 62 Length 00 Cepaclty In Cubic Feet of Gas Per Hour 10 270 353 587 700 1,100 1,370 1 2,590 2,990 4,510 5,037 9,600 10,700 18,600 21,600 25 166 220 374 444 709 876 J 1,620 1,870 2,890 3,258 6,040 6,780 11,900 13,700 30 151 200 342 405 650 801 1,480 1,700 2,640 2,987 5,510 6,200 10,900 127500 40 129 172 297 351 567 696 1,270 1,470 2,300 2,605 4,760 5,380 9,440 10,900 50 115 154 266 314 510 624 1,140 1,3 00 2,060 2,343 4,260 4,820 8,470 9,720 75 93 124 218 257 420 512 922 1,070 1,690 1,932 3,470 3,950 6,940 7,940 80 89 120 211 249 407 496 892 1,030 1,640 1,874 3,360 3,820 6,730 7,690 100 79 107 189 222 366 445 795 920 1,470 1,685 3,000 3,420 6,030 6,880 150 64 87 155 182 302 364 646 748 1,210 1,389 2,440 2,800 4,940 5,620 200 55 75 135 157 263 317 557 645 7050 1,212 2,110 2,430 4,290 4,870 250 49 67 121 141 236 284 497 576 941 1,090 1,890 2,180 3,850 4,360 300 44 61 110 1 99 217 260 453 525 862 999 1,720 1,990 3,520 3,980 400 38 52 96 111 189 225 390 453 749 971 1,490 1,730 3,060 3,450 500 34 86 100 170 202 348 404 1 552 783 1,330 1 1,550 2,740 3,090 F -r o1. 1 ml:ll - Zj-y =11, c cool - .3u4.a urn, 1 pound per square mch = 6.895 kPa, 1-inch water column = 0.2488 kPa, 1 British thermal unit per hour = 0.2931 W, 1 cubic foot per hour - 0.0283 m'/h, 1 degree = 0.01745 rad. Notes: 1. Table does not include effect of pressure drop across the line regulator. Where regulator loss exceeds 3/4 psi, DO NOT USE. THIS TABLE. Consult with the regulator manufacturer for pressure drops and capacity factors. Pressure drops across a regulator may vary with flow rate. 2. CAUTION: Capacities shown in the table might exceed maximum capacity for a selected regulator. Consult with the regulator or tubing manufacturer for guidance. 3. Table includes losses for four 90-degree bends and two end fittings. Tubing runs with larger numbers of bends or fittings shall be increased by an equivalent length of tubing to the following equation: L - 1.3n where L is additional length (feet) of tubing and n is the number of additional fittings or bends. 4. EHD-Equivalent Hydraulic Diameter, which is a measure of the relative hydraulic efficiency between different tubing sizes. The greater the value of EHD, the greater the gas capacity of the tubing. 5. Table entries have been rounded to three significant digits. 2020 MIINNESOTA FUEL GAS CODE 45 CIFShl V m ICC A ASHRAE ALL RIGHTS RESERVED. A--d by Thomas Krwie lO:rauseemnsperteeml, (.) Order Nwnbrr a� oaaa2zn m Acg K a 12:22 PM (FDT) punuanl m tJ<rnr Agreemrnr wuh ICC do ASKRAE N. funkier repred;klgo, no 300943272 GAS PIPING INSTALLATIONS TABLE 402.4(12) a atura SEMIRIGID COPPER TUBING rrvasure 2.0 psi uro rop psi TPORFur-MV11V TUBE SIZE (inch) Nominal K 6 L 114 '!, '!, 'I, 1 1114 1'!, 2 ACR '1, '!, '!, '!a 71, 1 1'!, 1318 - Outslde 0.375 0.500 0.625 0.750 0.875 1 1.125 137S 1.625 2125 Inside 0305 0.402 0.527 0.652 0.745 GMS 1.245 1ASI 1.l59 Length (ft) Capacity to Cuble Feat of Gas Per Hour 10 245 SD6 1,030 1,800 2,550 5,450 9,820 15,500 32,200 20 169 348 008 1,240 1,760 3,750 6,750 10,600 22,200 30 135 279 568 993 1,410 3,010 5,420 8,550 17,800 40 116 239 486 850 1 110 2,580 4,640 7,310 I5 200 50 03 212 431 754 1,070 2280 4,110 6,480 I3,500 60 93 93 192 39] b83 969 2070 3,730 5,870 12,2D0 70 86 177 359 628 891 1,900 3,430 5,400 11,300 80 80 164 334 5" 229 1,770 3,190 5,030 10,500 90 75 154 314 548 778 1,660 2,990 41720 9,820 100 71 146 296 518 735 1,570 2,830 4,450 9,280 125 63 129 263 459 651 1,390 2,500 3,950 8,220 150 57 117 238 416 590 1,260 2,270 3,580 7.450 175 52 109 119 383 543 1,160 2, 990 3,290 6,850 200 44 100 204 356 505 1,080 1,940 3,060 6,380 250 43 89 881 115 4 88 956 1,720 2,710 5,650 300 39 80 664 286 406 666 1,560 2,460 5,120 350 36 74 150 263 373 797 1,430 2,260 4 710 400 33 69 140 245 347 741 1.330 2,100 4,380 450 31 65 131 230 326 696 1,250 1,970 4,110 5D0 30 61 124 217 308 557 1,180 1,870 3,890 550 28 58 118 206 992 224 1,120 1,770 3,690 600 27 55 112 1% 279 595 1,070 1,690 3,520 650 26 53 106 188 267 570 1,030 1,620 3,370 700 25 51 103 l81 256 548 986 1,550 3,240 750 24 49 300 174 247 528 950 1,500 3,120 80o 23 47 96 668 239 510 917 1,450 3,010 850 22 46 93 163 231 493 R88 1,400 2,920 900 22 44 90 158 224 478 861 1,360 2,830 950 21 43 88 153 217 464 836 1,320 2,740 1,000 20 42 85 149 211 452 813 1,290 2,670 1,100 19 40 81 422 001 429 772 1,220 2,540 1,200 18 38 77 135 192 409 737 1,160 2,420 1,3DO 18 36 74 129 183 392 705 1,110 2,320 1,400 17 35 71 224 776 376 678 1,070 2,230 1,500 16 34 68 120 170 363 553 1,D30 2,140 1,600 16 33 66 116 164 350 630 994 2,070 1,700 15 31 64 112 159 339 610 962 2,000 1,800 25 30 62 lOR 154 329 592 933 1,940 1,900 14 30 60 105 l49 319 575 906 1,890 2,000 14 29 59 102 145 310 559 88l 1,830 For SI: I inch = 25.4 mm, I foot - 304.8 mm, I pound per square inch = 6.895 kPa, 1-inch water column = 0.2488 kPa, l British thermal unit per hour = 0.2931 W, 1 cubic foot per hour= 0.0283 m'/h, 1 degree o 0.01745 rad. Notes: 1. Table capacities are based on Type K capper tubing inside diameter (shown), which has the smallest inside diameter of the copper tubing products. 2, Table entries have been rounded to three significant digits. 2020 MINNESOTA FUEL GAS CODE 39 00prdg410'N''CC & ASHRAE. ALL RIGHTS RESERVED. A-m d by TM1Om,s Knu,e f �nure®e .rpestmml. (-) �>rda Nmi6.r,tmw��ry on Aug f 0. xosx rzz2 PM (PIY17 yurwe� b IJeau� Agnyre, W"h ICC & ASHRAE. No fw�u r pr ducu0%no .f^ Pro}ect Name: Date: JurisdkZw: ID: Applicant Phone: Jobsfte: Code: Reviewed: 09/19/2024 City of Spring Park 24S P-00080 (612) 284-1550 4068 SUNSET DRIVE Approval Status: Construction Type: Applicant Name: Applicant Email: City of Spring Park 4349 Warren Ave Spring Park, MN 55384 Phone (952) 471-9051 Fax (952) 471-9160 Approved with Comments Midwest Electric and Generator 2020 1300, Minnesota Building Code Administration; 20201305, Minnesota Building Code Mechanical The plans and specifications, for the project named above, have been reviewed for substantial compliance with the current Minnesota State Building Code. This review is limited to the submitted scope of work; is based upon the supposition that the data on which the design is based are correct and that the necessary legal authority has been obtained to construct the project. Although every attempt has been made to identify code issues or concerns for proper and necessary change, the project designer(s), the building contractor(s) and the property owner(s) are ultimately responsible for providing complete code compliance and maintaining minimum construction standards for the safeguarding of life or limb, health, public welfare and property while constructing this project. Approval is based on the correction of all noted deficiencies and compliance with all items listed below. Any changes from these documents and/or additional information shall be submitted to the Department of Building Safety for code compliance review and approval. Written response of approval must be on site prior to implementation of such changes. The following information is related to the submitted plans/scope or as general information regarding code compliance. Compliance with the stated requirements will be verified during the construction process. All work shall be inspected. It is the responsibility of the contractortinstaller to contact the Department of Building Safety, when ready to schedule an inspection, at (952) 442-7520 during regular business hours. If you have any questions or concerns regarding this plan review, please contact me via telephone at ( 952) 442-7520 or email at codereview@mnspect.com. Tom Krause Plans Examiner tkrause@safebuift.com 4068 SUNSET DRIVE Page 1 Or, PARK Plan S chic Items: City of Spring Park 4349 Warren Ave Spring Park, MN 55384 Phone (952) 471-9051 Fax (952) 471-9160 Mechanical: Approved with Comments - Tom Krause, tkrause@safebuiltcom SCOPE OF WORK: Installing gas line from gas meter at the exterior of the building to the generator located adjacent to the building. PLAN SPECIFIC ITEMS (to be completed during the cortsbxK;tlon process): 1. Minimum burial depth of the gas line shall be 12" below grade. (2020 Minnesota State Fuel Gas Code, Section 404.12) 2. Gas line installed underground shall be of approved material. 3. Plastic pipe installed underground shall be permitted to terminate above ground outside of buildings where installed in premanufactured anodeless risers or service head adapter risers that are installed in accordance with the manufacturer's instructions. (2020 Minnesota State Fuel Gas Code, Section 404.17) 4. A yellow insulated copper tracer wire or other approved conductor, or a product specially designed for that purpose, shall be installed adjacent to underground nonmetallic piping. Access shall be provided to the tracer wire or the tracer wire shall terminate above ground at each end of the nonmetallic piping. The tracer wire size shall be not less thanl8 AWG and the insulation type shall be suitable for direct burial. (2020 Minnesota State Fuel Gas Code, Section 44.17.3) 5. Gas piping installed above ground and outdoors shall be elevated not less than 3'/:" above ground. (2020 Minnesota State Fuel Gas Code, Section 404.9) 6. CSST gas piping placed underground or exposed to the exterior elements shall be installed in accordance with the manufacturer's installation instructions. 7. Gas line material, length, and Generator BTUs weren't provided during the permit application process. Use tables attached to the approved plan to verify the correct gas piping size has been installed based on the material, the distance from the meter to the generator, and the BTUs of the generator. 8. Gas line valves shall be of an approved type, shall be constructed of materials compatible with the piping, and shall comply with the standard that Is applicable for the pressure and application in accordance with Table 409.1.1 of the 2020 Minnesota State Fuel Gas Code. Valves shall also be installed wltttin 6'-0' of the appliance and upstream of the union (2020 Minnesota State Fuel Gas Code, Section 409.5. 1) 9. 408.4 Sediment trap (2020 Minnesota State Fuel Gas Code, Section 408.4). Where a sediment trap is not incorporated as part of the appliance, a sediment trap shall be installed downstream of the appliance shutoff valve as close to the inlet of the appliance as practical. The sediment trap shall be either a tee fitting having a capped nipple of any length installed vertically in the bottommost opening of thetee. GENERAL ITEMS: Construction or work shall be inspected in accordance with the requirements of Minnesota Rule 1300.0210. 2. It is the responsibility of the contractor/installer to contact the Department of Building Safety, when ready to schedule an inspection, at (952) 442-7520 between the hours of 8.00 a.m. and 4:30 p.m., Monday through Friday. 3. The approved permit and all related plans and documentation shall be on site and available to the inspector at the time of inspection. 4. Failure to provide the required documentation to the inspector at the time of inspection may result in a cancelation of the inspection and additional inspection fees for the additional inspection(s). 5. The field inspector may identify additional code requirement. 4068 SUNSET DRIVE page 2 A* - City of Spring Park 4349 Warren Ave Spring Park, MN 55384 Phone (952) 471-9051 Fax (952) 471-9160 6. Applicable Code(s): 2020 Minnesota State Mechanical and Fuel Gas Code Required Inspections: -Underground Roush -in prior to cover gas piping; -Gas pipe air test-25# for 30 minutes; - Final -after gas line has been connected at both ends, valve(s) have been installed, and project is complete. 4068 SUNSET DRIVE Page 3 City of Spring Park 4349 Warren Ave. Spring Park, MN 55384 City: 952-471-9051 MNSPECT: 952-442-7520 COMMERCIAL MECHANICAL PERMIT APPLICATION Permit i Number: . CC08 Job Address /�! o t�o2l Vrwo, Owner's Phone l U Owner's Name l.{ i�1-1— �OC'11� Business Named r� BQ7 f�f N 5 Owner's Address q6 to City/State/Zip o A 9L Mechanical Contractor9`A f haj&_ M A&Ucc4 phone U L Address :5--o1n `L2,141JCity/State/Zip R,Ir �� A) State Bond No. A.L Qa I Sb _ Gas Fitters License No. CHECK TYPE OF WORK: ❑ New Construction ❑ Addition �6 Alteration ❑ Replacement # # 11# # I 1 11#1# Furnace Air Cond In Floor Heat Air Exch Fireplace Exhaust Fan Boiler Wall HeaterJ Rooftop Unit Unit Heater Range Hood 11 1 Make -Up Air Equipmellt Efficiency System Tag(s) Mfg. & Model No. equipment Type HeatingCooling Rated Capacity Rated Efficiency Minimum Efficiency Rated Ca aci Rated Efficiency Minimum Efficiency Econ. Min. Efficient VALUATION OF WORK VALUATION APPROVED $ I hereby certify that 1 have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other state or local law regulating construction or the performance of construction. i agree to pay all plan review fees even ff I choose not to proceed with the work. i certify all taxes and Municipal fees owed in connectio with thl rty are current. Applicant's Signature Date Permit Fee ........................... '7$. 50 Code Review- .................... S1. 0,5 State Surcharge .................. • -0-5_ Other.................................. Total Permit Charge $ 13D• l8 loillifIALI-LyaliTlWA Pians checked by: Date: Jamie Hoffman From: payment4@thepaymentgroup.com Sent: Friday, September 20, 2024 1:01 PM To: Jamie Hoffman Cc: payment@thepaymentgroup.com Subject: KRISTIN KAUTZ Permit Payment to Spring Park, MN - Permits & Licenses from TPG Dear Spring Park, MN - Permits & Licenses, KRISTIN KAUTZ has made a web Payment through The Payment Group for: zzm� 0 Date Paid: Friday, 20 September 2024 13:01:03 CT Confirmation: WYBLPZ Credit Card Number (last 4 2531 digits): Credit Card Type: Visa MIDWEST ELECTRIC 10215 TWIN LAKES KRISTIN KAUTZ AND GENERATOR RD NW, ELK RIVER, 24SP-00080 $130.18 MN 55330 KRISTIN KAUTZ can be reached at: 612-284-1550 or kristin@midwestgenerators.com if there are any questions regarding this payment. Click here to login to your The Payment Group admin account Thank you once again for choosing The Payment Group! RECEIPT City of Spring Park 4349 Warren Ave, Spring Park, MN 55384 (952) 471-9051 24SP-00080 1 Gas Line Only (Commercial) Payment Amount: $130.18 Transaction Method Payer Cashier Credit Card Midwest Electric and Generator Jamie Hoffman Comments Assessed Fee Items SPRING PARK On Luke winneto* Receipt Number. 343 September 23, 2024 Reference Number WY8LPZ Fee items being paid by this payment Assessed Fee Item Account Code Assessed Amount Paid Balance Due 09/19/24 State Surcharge $0.65 $0.65 $0.00 09/19/24 Commercial Gas Line Only Plan Review $51.03 $51.03 $0.00 09/19/24 Commercial Gas Line Only $78.50 $78.50 $0.00 Application Info Property Address 4068 SUNSET DRIVE SPRING PARK, MN 55384 Description of Work New gas line for generator. Tota/s $130.18 $130.18 Previous Payments $0.00 Remaining Balance Due $0.00 Property Owner Property Owner Address Valuation SEASONAL INVESTMENTS 4068 SUNSET DR $1,298.00 LLC/CLIFF ROCKVAM SPRING PARK, MN 55384