Plans - 24SP-00018 - Approved Plan - 3990 SunsetBasements, Habitable attics and every Sleeping Room shall have at least one operable Emergency Escape and Rescue Opening leading directly to the outdoors. Required dimensions are as follow are measure to the edge of the clear opening: o Maximum sill height above finished floor 44-inches o Minimum opening area of 5.7 square feet, except grade floor openings shall have 5.0 square feet minimum o Minimum opening height of 24-inches o Minimum opening width of 20-inches Openings shall be operable from the inside without the use of tools, keys or special knowledge. Read all attached materials. Everyone performing work to which the code is applicable shall comply with the code. The field copy of these plans must be kept on-site and made available to inspector during all inspections. To schedule inspections call (952) 442-7520 Please have the permit number and street address ready at the time of the call. Electrical All electrical must be approved by local Electrical Inspector. For electrical permit inquiries please contact the City of Mound Electrical Inspector. Dave Hucky (952) 442-7520 Hardwired and interconnected smoke alarms are required in the following locations: 1 (one) in every bedroom 1 (one) in the area outside every bedroom At least 1 (one) per floor where no bedrooms exist including basements and habitable attics Hardwired and interconnected CO alarms are required in the following locations: 1 (one) Carbon Monoxide (CO) alarm is required outside of and within 10-feet of every bedroom or sleeping area. 1 (one) CO alarm is required on every level that contains a bedroom or sleeping area. 1 (one) CO alarm is required inside bedrooms when that bedroom or attached bathroom contains a fuel fired appliance Interconnection may be achieved by use of a UL 217 or UL 2034 Listed Wireless System Exceptions: Existing spaces, where interior finishes are not removed exposing the structure, may have battery operated smoke or CO alarms that are not interconnected. All required alarms must be installed and operational at time of final building inspection. Reviewed for Code Compliance By: Date: This review is limited to the submitted scope of work, is based upon the supposition that the plan accurately depicts the intended construction and end-use, that the necessary legal authority has been obtained to construct the project and work is subject to code compliance and field inspection during construction. Permit #:Code Edition: Occupancy Classification: Type of Construction:Nick Qualle 5/31/2024 24SP-00018 V-B R-2 2020 MN Buildig Code Separate Permits Required For: X X X Electrical Mechanical Plumbing Fireplace Demolition Fire Suppression System Septic Per phone conversation with Don Driggs, all structural components to be completed by contractor and then inspected by engineer. Engineer to provide final structural report on all structural repairs completed. Engineering report shall be made available at the framing inspection for review and sign off of the framing portion of the project. Replacing three floor joists due to fire damage. Sistering rest of floor joists to level floor out and then installing new floor sheathing. Remove and replaced some of siding and sheathing Removing existing door and windows and installing 10' wide patio door unit. Engineer report to address all structural requirements. Items written in blue were provided during a phone conversation by Don Driggs on 06/03/2024. Remove and replaced some siding and sheathing Additional porch roof rafters may need to be replaced. Will verify once repairs are underway and engineer will include in framing report. Gut and rebuilt entire upper level.