Plans - 24SP-00018 - Approved Plan - 3990 SunsetBasements, Habitable attics and every
Sleeping Room shall have at least one
operable Emergency Escape and Rescue
Opening leading directly to the outdoors.
Required dimensions are as follow are
measure to the edge of the clear opening:
o Maximum sill height above finished floor
44-inches
o Minimum opening area of 5.7 square
feet, except grade floor openings shall
have 5.0 square feet minimum
o Minimum opening height of 24-inches
o Minimum opening width of 20-inches
Openings shall be operable from the inside
without the use of tools, keys or special
knowledge.
Read all attached materials.
Everyone performing work to
which the code is applicable
shall comply with the code.
The field copy of these plans must be kept
on-site and made available to inspector
during all inspections.
To schedule inspections call
(952) 442-7520
Please have the permit number and street
address ready at the time of the call.
Electrical
All electrical must be approved by local Electrical Inspector.
For electrical permit inquiries please contact the City of Mound
Electrical Inspector.
Dave Hucky (952) 442-7520
Hardwired and interconnected smoke alarms are
required in the following locations:
1 (one) in every bedroom
1 (one) in the area outside every bedroom
At least 1 (one) per floor where no bedrooms exist
including basements and habitable attics
Hardwired and interconnected CO alarms are
required in the following locations:
1 (one) Carbon Monoxide (CO) alarm is required outside
of and within 10-feet of every bedroom or sleeping area.
1 (one) CO alarm is required on every level that contains
a bedroom or sleeping area.
1 (one) CO alarm is required inside bedrooms when that
bedroom or attached bathroom contains a fuel fired
appliance
Interconnection may be achieved by use of a
UL 217 or UL 2034 Listed Wireless System
Exceptions:
Existing spaces, where interior finishes are not removed
exposing the structure, may have battery operated smoke
or CO alarms that are not interconnected.
All required alarms must be installed and operational
at time of final building inspection.
Reviewed for Code Compliance
By:
Date:
This review is limited to the submitted scope of work, is based upon the supposition that the plan
accurately depicts the intended construction and end-use, that the necessary legal authority has
been obtained to construct the project and work is subject to code compliance and field
inspection during construction.
Permit #:Code Edition:
Occupancy Classification:
Type of Construction:Nick Qualle
5/31/2024
24SP-00018
V-B
R-2
2020 MN Buildig Code
Separate Permits
Required For:
X
X
X
Electrical
Mechanical
Plumbing
Fireplace
Demolition
Fire Suppression System
Septic
Per phone conversation with Don Driggs, all structural components to
be completed by contractor and then inspected by engineer.
Engineer to provide final structural report on all structural repairs
completed. Engineering report shall be made available at the framing
inspection for review and sign off of the framing portion of the project.
Replacing three floor joists due to
fire damage. Sistering rest of floor
joists to level floor out and then
installing new floor sheathing.
Remove and replaced some
of siding and sheathing
Removing existing door and
windows and installing 10' wide
patio door unit. Engineer report to
address all structural requirements.
Items written in blue were provided
during a phone conversation by
Don Driggs on 06/03/2024.
Remove and replaced
some siding and sheathing
Additional porch roof
rafters may need to
be replaced. Will
verify once repairs
are underway and
engineer will include
in framing report.
Gut and rebuilt
entire upper level.