Permits - Permit# 25SP-00054 - 4100 Spring Street - 8/7/2025'i", I City of Spring Park I Re -roof (Commercial)
PARK
Oft f
4349 Warren Ave, Spring Park, MN 55384
Phone:(952) 471-9051 Fax: (952) 471-9160
For Inspections: (952) 442-7520
25SP-00054
Date Issued: 08/07/2025
Property Owner: LAKEVIEW LOFTS CONDO/GCM
Expiration Date: 02/03/2026
Construction & Maintenance
Job Site Address: 4100 SPRING ST, SPRING PARK, MN
Mailing Address: 2655 CHESHIRE LA N
55384
Category: Commercial Miscellaneous
PLYMOUTH, MN 55447
Permit Type: Re -roof (Commercial)
Phone (612) 859-9596
Valuation: $74,875.00
Email:
Description of Work:
Tear off and re -roof of the shingle roof section, excluding the flat roof sections
Subdivision:
Required Setbacks:
Parcel ID: 18-117-23-44-0106
Filing:
Actual Setbacks:
Lot:
Block:
Total Sq Ft:
Contractors:
Fee Items
Amount
Primary Walker Roofing Company (651) 251-0910
State Surcharge
$ 37.44
Building Walker Roofing Company (651) 251-0910
Commercial Roof/Siding/Window/Door
$ 1,050.75
Commercial R/S/W/D Plan Review
$ 682.99
Total Fees:
$ 1,771.18
NOTICE
Signature of Applicant/Date
Building Department Signature/Date
08/07/2025
MUST BE POSTED ON JOB SITE
INSPECTION CARD
City of Spring Park
SPRING PARK
On Lake Minnetonka 4349 Warren Ave, Spring Park, MN 55384
POST THIS CARD IN A SAFE CONSPICUOUS LOCATION. PLEASE DO NOT REMOVE THIS NOTICE UNTIL ALL REQUIRED INSPECTIONS ARE MADE AND SIGNED OFF BY THE APPROPRIATE
AUTHORITY AND THE BUILDING IS APPROVED FOR OCCUPANCY. STAMPED APPROVED PLANS MUST BE AVAILABLE ON THE JOBSITE.
Re -roof
PERMIT NO.: 25SP-00054 PERMIT TYPE: (Commercial) ISSUED DATE: 08/07/2025 EXPIRATION DATE: 02/03/2026
18-117-23-
PROJECT ADDRESS: 4100 SPRING ST, SPRING PARK, MN 55384 PARCEL NO.: 44-0106
LAKEVIEW LOFTS CONDO/GCM
OWNER: Construction & Maintenance OWNER PHONE: (612) 859-9596
CONTRACTOR: Walker Roofing Company CONTRACTOR PHONE: (651) 251-0910
APPLICANT: Walker Roofing - Kang APPLICANT PHONE: (651) 251-0910
DESCRIPTION OF WORK: Tear off and re -roof of the shingle roof section, excluding the flat roof sections
CONSTRUCTION TYPE: OCCUPANT LOAD:
INSPECTION
Final/In-Progress
Fire Approval:
DATE
INSP PASSED
PW Approval:
To request an inspection: (952) 442-7520
COMMENTS
Date:
Date:
DATE
INSPECTION INSP PASSED
Engineering
Approval:
Other (
Date:
Date:
COMMENTS
Page 1 of 1
CITY OF SPRING PARK
BUILDING PERMIT
PAGE 1
4349 Warren Avenue
25SP-00054
Spring Park, MN 55384 ❑ Handout Given
Routed to SAFEbuilt
Phone: 952-471-9051 Fax: 952-471-9160 ❑ Lead Handout Given
SITE ADDRESS:4100 SDrina Street _ PID: _
1) Was the home constructed before 1978? (YES❑, continue with line 2, NO ❑ continue without completing EPA Section)
2) Will the work disturb >_6 sq ft of interior painted surfaces or >_20 sq ft of exterior painted surfaces? (YES ❑ go to line 4, NOpline 3)
3) Are there any windows being replaced? (YES ❑, go to line 4, NODcontinue without completing EPA Section)
4) Has this home been Certified Lead Free? (YES ❑ , you MUST Attach Certification Information, NO ❑ complete line 5)
5) EPA Contractor Certification Number: NAT -
PROPERTY OWNER: Lakeview Lofts Address:4100 Spring St
cit :Spring Park State: MN zip. 55384 Email:
Contact Name:Jeff Reinholdz Phone:612-859-9596
CONTRACTOR: Walker Roofing Address:2441 Ventura Dr
cit : Woodbury State: MN zip:55125 Phone: 651-251-0910 Fax -
Contractor License No: BC004229 Contact Name: Kang Phone: 651-251-0910
Email: permits@walkerroofing.com
ARCHITECT: Address:
Cit State: MN zip. Phone: Fax:
Email: Contact Name. Phone:
TYPE OF WORK: ❑New Construction ❑Deck [DRe-Roof
pCommercial ❑Residential ❑Change of Use ❑Pool ❑Re -Side
EST. VALUATION OF WORK ❑Finish Basement ❑Retaining Wall ❑Fence
$ 74875.00 ❑ Remodel ❑Porch ❑Shed _ sq ft
Square feet: ❑Addition ❑Demolition ❑Window/Door Replacement
115 ❑Garage-Attached/Detach ❑Plumbing -provide detail on Page 2 # being replaced
Detailed Description of Work: I El Accessory Structure ❑Mechanical -provide detail on Paqe 2 ❑Mist Other
Tear off and re -roof of the shingle roof sections, excluding the flat roof sections.
Signature of this application by the legal property owner or a licensed contractor, as the owner's tepresentalive, is required and authorizes the Zoning Adrihnrst airy or designee and the Building
Olr'Crel or designee to enter upon the property to perform needed inspections. Entry may be without prior notice. I hereby acknowledge that I have read this application and state that all information
,s true and correct to the best of my knowledge, I further agree that all work performed will be In accordance with approved plans, specifications and conditions and to abide by all ordinances of the
Municipality and the laws of the State of Minnesota regarding actions taken pursuant to this permit. I agree to pay all plan review fees even if I choose not to proceed with the work. Permit
expires when work is not commenred within 180 d ys from date of permit, or if work is suspended, abandoned. or not inspected for 180 days Work beyond Me swpe of this permit, or work without
.l pemil or rns-eclion, w,ll be subject to a pen. re
SIGNATURE OF APP (CANT: DATE:a' 2
PRINTED NAME: This is the signature of: ❑Owner or wner's Representative
OCCUP. TYPE: -CANST. TYPE: CODE: BLDG SPRINKLED Yes / No
VALUATION: $
Permit Fee: $ t Park Dedication: $
Plan Review Fee: $ a • SAC Charge: $
State Surcharge: $ ,3� . y �{ WAC Charge: $
Site Inspection Fee: $ Sewer Hook -Up: $
S.E.C. Fee: $ Water Hook -Up: $
Investigation Fee / Other Fee: $ Sewer Trunk: S
zCopy
Charge ($.25 per 8.5xl 1 page) $ Water Trunk: $
O
License Check ($5) / Lead Check ($5) $ Water Meter $
W
SUB -TOTAL $ �'. ��i City Fee: $Cn
D
Plumbing Fee (from Page 2) $ Other: S
v
_
Mechanical Fee (from Page 2) $ TOTAL DUE: $ �'"( , L$
LL
Special Conditions/Required Setbacks:
O
Building Approval By: DATE: 8/ 0 5/ 2 0 2 5
Printed Building Approval By: Kevin Kamerud ❑ License Verification ❑ Lead Verification - Checked By:
City Approval By- DATE:
Paid: Date. Receipt No. By:
Read all attached
materials.
Everyone performing
work to which the code
is applicable shall
comply with the code.
The field copy of these plans must
be kept on -site and made
available to inspector during all
inspections.
To schedule inspections call
(952) 442-7520
Please have the permit number
and street address ready at the
time of the call.
Plan Revisions
All construction shall
comply with the approved
Ip ans.
Plan revisions will not be
reviewed in the field without
prior approval from the
Building Official. Submit all
plan revisions to the
Department of Building
Safety for review, prior to
their construction.
Buildings shall have approved address numbers,
building numbers or approved building identification
placed in a position that is plainly legible and visible
from the street or road fronting the property. These
numbers shall contrast with their background.
Addresses shall be Arabic numbers or alphabetical
letters. Numbers shall not be spelled out. Each
character shall be a minimum of 4 inches high with
a minimum stroke width of 1/2 inch. Where access
is by means of a private road and the building
cannot be viewed from the public way, a
monument, pole or other sign or means of
identification shall be used and maintained.
Electrical
All electrical must be approved by State Electrical Inspector.
For electrical permit inquiries please contact the
Department of Labor & Industry.
www.dli.mn.gov
dli.electricity@state.mn.us / (651) 284-5026
REFER TO APPROVAL LETTER
FOR ADDITONAL COMMENTS AND
REQUIREMENTS
Manufacturer's Installation Instructions
Shall Be Followed And Available To The
Field Inspector At Time Of Inspection.
Reviewed for Code Compliance
This review is limited to the submitted scope of work, is based upon the supposition that the plan
accurately depicts the intended construction and end -use, that the necessary legal authority has
been obtained to construct the project and work is subject to code compliance and field
inspection during construction.
By: XevinXamerud Type of Construction: Not Applicable
Date: 8/5/2025 Occupancy Classification:
Permit #: 25SP-00054 Code Edition: 2020 MN Building Code
�� Phone: 952-442-7520
MN.. -.,PE LLC Fax: 952-442-7521
f , 1P` (� ; -x• Email: infoPmnspect.com
Commercial Roofing Replacement - General Scope of Work
Answer all questions and submit with your permit application.
1. What is the total area of the roof in square feet? j 0 sq. ft.
2. What is/are the roof pitch (es)? :12 :12 :12
3. Is there an attic or u onditioned space between the interior ceiling and the roof deck?
(circle one) s No
4. Will you be replaci or ai�ing anything otherthan the roof covering?
(circle one) Yes No
5. If you answered "yes" to question 4, identify what will be replaced or repaired.
6. What is/are the existing roof covering(s)?
SAL
7. What is the new roof covering to be installed?
8. Will you be removin a existing roof 6vering?
(circle one) " No
9. Will you be reusing any of thLQ existing materials?
(circle one) Yes to
10. If you answered "yes" to question 8, identify all of the materials that will be reused (i.e.
flashing, insulation, etc.)
11.Is there soffitventing?
(circle one) ( Yes) No
12. Identifyventing type, numberof vents to be installed, and the vent opening size?
Ridge Venting: wide x long /'Y(r X.14- e4 S 1012"
Roof Vents: 8" x 8" 10" x 10" Other x
Mechanical:
Oth er:
Commercial Roofing ScopeofWork Page 1 of 1 Revised July2020
City of Spring Park
4349 Warren Ave
Spring Park, MN 55384
Phone (952) 471-9051
PARK
Fax (952) 471-9160
Project Name:
Date:
08/05/2025
Approval Status: Approved with Comments
Jurisdiction:
City of Spring Park
Construction Type:
ID:
25SP-00054
Applicant Name: Walker Roofing - Kang
Applicant Phone:
(651) 251-0910
Applicant Email: permits@walkerroofing.com
Jobsite:
4100 SPRING ST
Code:
2020 1300, Minnesota Building
Code Administration; 2020 1305, Minnesota Building Code
Reviewed:
Building
The plans and specifications, for the project named above, have been reviewed for substantial compliance with the
current Minnesota State Building Code. This review is limited to the submitted scope of work; is based upon the
supposition that the data on which the design is based are correct and that the necessary legal authority has been
obtained to construct the project. Although every attempt has been made to identify code issues or concerns for proper
and necessary change, the project designer(s), the building contractor(s) and the property owner(s) are ultimately
responsible for providing complete code compliance and maintaining minimum construction standards for the
safeguarding of life or limb, health, public welfare and property while constructing this project.
Approval is based on the correction of all noted deficiencies and compliance with all items listed below. Any changes from
these documents and/or additional information shall be submitted to the Department of Building Safety for code
compliance review and approval. Written response of approval must be on site prior to implementation of such changes.
The following information is related to the submitted plans/scope or as general information regarding code compliance.
Compliance with the stated requirements will be verified during the construction process.
All work shall be inspected. It is the responsibility of the contractor/installer to contact the Department of Building Safety,
when ready to schedule an inspection, at (952) 442-7520 during regular business hours.
If you have any questions or concerns regarding this plan review, please contact me via telephone at (952) 442-7520 or
email at codereview@mnspect.com.
Kevin Kamerud
Plans Examiner
(952) 442-7520
kkamerud@safebuilt.com
4100 SPRING ST Page 1
G PARK
Plan Specific Items:
Building: Approved with Comments - Kevin Kamerud, kkamerud@safebuilt.com
1. Minnesota Building Code Items:
City of Spring Park
4349 Warren Ave
Spring Park, MN 55384
Phone (952) 471-9051
Fax (952) 471-9160
i. Roof Coverings shall be installed according to the MN building code and the approved manufacturer's
instructions such that they shall protect the building. (MBC 1503.1). All roof coverings and roof assemblies
must comply with performance requirements (MBC 1504) and fire classification (MBC 1505)
ii. Flashina: Flashing shall be installed in such a manner so as to prevent moisture entering the wall and roof.
Flashing shall be installed at wall and roof intersections, at gutters, wherever there is a change in roof slope
or direction, and around roof openings. Metal flashing shall be corrosion resistant with a thickness of not
less than 0.019-inch galvanized steel (MBC 1503.2)
iii. Crickets and saddles: A cricket or saddles shall be installed on the ridge side of any chimney or penetration
greater than 30" (MBC 1503.5)
iv. Roof replacement shall include removing all existing layers of roof coverings down to the roof deck. (MBC
1511.3)
a. Exception: Where existing roof assembly includes an ice barrier membrane that is adhered to the
roof deck, the existing ice barrier membrane shall be permitted to remain in place and covered with
an additional layer of ice barrier membrane
v. Roof recover: (MBC 1511.3.1) The installation of a new roof covering over an existing roof covering shall be
permitted where any of the following occur:
a. The new roof covering is installed in accordance with the manufacturer's instructions.
b. Complete and separate roofing systems, such as standing -seam metal panel systems that are
designed to transmit the roof loads directly to the buildings structural system and do not rely on the
existing roof covering for support shall not require the removal of existing coverings.
c. Metal panel, metal shingle, and concrete and clay tile roof coverings shall be installed over existing
wood shake roofs.
d. The application of a new protective roof coating over and existing protective roof coating, metal roof
panel, spray poly foam roof, built-up roof, modified roofing, thermoset and thermoplastic single -ply
roofing shall be permitted without tear off of existing coverings.
vi. A roof recover shall not be permitted where any of the following conditions occur:
a. The existing roof or roof covering is water soaked or has deteriorated to the point where the existing
roof or roof covering is not adequate as a base for additional roofing.
b. Where the existing roof covering is wood shake, slate, clay, cement, or asbestos -cement tile.
c. Where the existing roof has two or more applications of any type of roof covering.
vii. Reinstallation of materials_ Existing vent flashing, metal edging, drain outlets, collars, and metal
counterflashing shall not be reinstalled where rusted, damaged, or deteriorated. Flashings shall be
reconstructed in accordance with the manufacturer's instructions (MBC 1511.5)
viii. Roof Ventilation: Intake and exhaust vents shall be provided in accordance with Section 1202.2 and the
manufacturer's installation instructions. (MBC 1503.4)
a. The net free ventilating area shall not be less than 1/150 of the space ventilated.
4100 SPRING ST Page 2
City of Spring Park
4349 Warren Ave
Spring Park, MN 55384
Phone (952) 471-9051
Fax (952) 471-9160
1. Exception: The net free cross -ventilation area shall be reduced to 1/300 if a Class I or II vapor
retarder is installed on the warm -in -winter side of the ceiling. At least 40%, but no more than
50% of the required venting area is provided by ventilators located in the upper portion of the
attic or rafter space, not more than 3 feet below the ridge, with the balance of ventilation
provided by eave or cornice vents. (MBC 1202.2.2)
b. Openings for ventilation over 1/4 inch shall be provided with corrosion -resistant wire screening or
similar material with openings between 1/16 -'/ inch.
ix. Underlayment: Table 1507.1.1(2)
Asphalt Shingles: For roof slopes from two units vertical in 12 units horizontal (2:12), up to four units
vertical in 12 units horizontal (4:12), underlayment shall be two layers applied as follows: Apply a 19-
inch strip of underlayment felt parallel to and starting at the eaves. Starting at the eave, apply 36-
inch-wide sheets of underlayment, overlapping successive sheets 19 inches. End laps shall be 4
inches and shall be offset by 6 feet. Distortions in the underlayment shall not interfere with the ability
of the shingles to seal. For roof slopes of four units vertical in 12 units horizontal (4:12) or greater,
underlayment shall be one layer applied as follows: Underlayment shall be applied shingle fashion,
parallel to and starting from the eave and lapped 2 inches, Distortions in the underlayment shall not
interfere with the ability of the shingles to seal. End laps shall be 4 inches and shall be offset by 6
feet.
2. Roof Type:
i. (MBC 1507.2) Asphalt Shingles:
a. Asphalt shingles shall be fastened to solidly sheathed decks
b. Asphalt shingles shall only be used on roof slopes of two units vertical and twelve units horizontal
(17%) or greater. Roof slopes 17% - 33 % double underlayment is required.
c. Required underlayment shall conform to ASTM D226 Type I or 11, ASTM D 4869 Type I -IV, or ASTM
D6757.
d. Asphalt shingles shall comply with ASTM D225 or ASTM D1970. (MBC 1507.2.5)
e. Fasteners shall be galvanized, stainless steel, aluminum, or copper roofing nails, minimum 12 gage
shank with a minimum 3/8" diameter head, and a minimum length of 3/" into the roof sheathing.
f. Asphalt shingles shall have the minimum number of fasteners required by the manufacturer, but not
less than four fasteners per strip shingle or two fasteners per individual shingle.
g. Asphalt shingles shall have a minimum wind resistance complying with Table 1507.2.7
h. Underlayment shall comply with MBC 1507.1.1
i. Ice barrier: In areas where there has been a history of ice forming along the eaves causing a backup
of water, an ice barrier shall be installed for asphalt shingles, metal roof shingles, mineral -surfaced
roll roofing, slate and slate -type shingles, wood shingles, and wood shakes. The ice barrier shall
consist of not less than two layers of underlayment cemented together, or a self -adhering polymer
modified bitumen sheet shall be used in place of normal underlayment and extend from the lowest
edges of all roof surfaces to a point not less than 24 inches inside the exterior wall line of the
building.
j. Valley linings shall be installed in accordance with manufacturer's instructions before applying
shingles.
k. Drip edge shall be provided at eave and rake edges or shingle roofs. Adjacent segments of the drip
edge shall be lapped no less than 2-inches. The vertical leg of drip edges shall be no less than 1-1/2"
in width and shall extend no less than 1/4"-inch below sheathing. The drip edge shall extend back on
4100 SPRING ST Page 3
7 City of Spring Park
4349 Warren Ave
Spring Park, MN 55384
one (952) 471-9051
ING PARK PhFax (952) 471-91160
JII?Irrctouha
the roof no less than 2-inches. Underlayment shall be installed over drip edges along rake edges.
Drip edges shall be mechanically fastened at intervals not greater than 12-inches.
3. Inspections:
4. Construction or work shall be inspected according to MN Rule 1300.0210 requirements.
5. The contractor/installer is responsible for contacting the Department of Building Safety to schedule all required
inspections. To schedule an inspection call (952) 442-7520 between the hours of 8:00 a.m. and 4:30 p.m., Monday
- Friday. Please have permit number available at the time of call.
6. The approved permit and all related plans and documentation shall be on site and available to the inspector at the
time of inspection. Failure to provide the required documentation to the inspector at the time of inspection may
result in a cancelation of the inspection and additional inspections fees for the additional inspection(s).
7. The field inspector may identify additional code compliance requirements. Any additional identified code
compliance requirements shall be completed.
1. Applicable Codes:
2. 2020 MN Building Code, (2018 IBC as amended)
3. 2020 MN State Fire Code, (2018 IFC as amended)
4. 2020 MN Energy Code (2018 as amended)
5. 2020 MN Mechanical & Fuel Gas Code (MMC) (2018 IMC & 2018 IFGC, ASHRAE 2016)
6. 2020 MN State Plumbing Code (MPC) (2012 UPC as amended)
4100 SPRING ST Page 4
Jamie Hoffman
From: payment5=thepaymentgroup.com@mg.thepaymentgroup.com on behalf of payment5
@thepaymentgroup.com
Sent: Wednesday, August 6, 2025 10:27 AM
To: Jamie Hoffman
Cc: payment@thepaymentgroup.com
Subject: CHER BAPP Permit Payment to Spring Park, MN - Permits & Licenses from TPG
Dear Spring Park, MN - Permits & Licenses,
MICHAEL KOHLER has made a web Payment through The Payment Group for:
Date Paid:
Confirmation:
Credit Card Number (last 4
digits):
Credit Card Type:
Wednesday, 06 August 2025 10:27:21 CT
WMISUV
Visa
CHER BAPP WALKER ROOFING 4100 SPRING ST
COMPANY
25SP-00054 $1,771.18
MICHAEL KOHLER can be reached at: 651-251-0910 or permits@walkerroofing.com if there are
any questions regarding this payment.
Click here to login to your The Payment Group admin account
Thank you once again for choosing The Payment Group!
RECEIPT
City of Spring Park
4349 Warren Ave, Spring Park, MN 55384
(952) 471-9051
25SP-00054 I Re -roof (Commercial)
Payment Amount: $1,771.18
SPRING PARK
On Lake Minnetonka
Receipt Number: 464
August 7, 2025
Transaction Method Payer Cashier Reference Number
Credit Card Walker Roofing Jamie Hoffman WMISUV
Comments
Assessed Fee Items
Fee items being paid by this payment
Assessed Fee Item Account Code Assessed Amount Paid Balance Due
On
08/05/25 State Surcharge $37.44 $37.44 $0.00
08/05/25 Commercial R/S/W/D Plan Review $682.99 $682.99 $0.00
08/05/25 Commercial Roof/Siding/Window/Door $1,050.75 $1,050.75 $0.00
Totals: $1,771.18 $1,771.18
Previous Payments $0.00
Remaining Balance Due $0.00
Application Info
Property Address Property Owner Property Owner Address Valuation
4100 SPRING ST LAKEVIEW LOFTS 2655 CHESHIRE LA N $74,875.00
SPRING PARK, MN 55384 CONDO/GCM Construction & PLYMOUTH, MN 55447
Maintenance
Description of Work
Tear off and re -roof of the shingle roof section, excluding the flat roof sections