Loading...
Plans - Permit# 26SP-00001 - 3880 Sunset Drive - 4/27/2026Adhered Masonry Veneer shall be installed in accordance with manufacturer's instructions, Lath Inspection required. The field copy of these plans must be kept on-site and made available to inspector during all inspections. To schedule inspections call (952) 442-7520 Please have the permit number and street address ready at the time of the call. Read all attached materials. Everyone performing work to which the code is applicable shall comply with the code. Plan Revisions All construction shall comply with the approved plans. Plan revisions will not be reviewed in the field without prior approval from the Building Official. Submit all plan revisions to the Department of Building Safety for review, prior to their construction. BEFORE YOU DIG Contact Gopher State One Call to locate buried utilities. 651-454-0002 or 800-252-1166 http://www.gopherstateonecall.org In accordance with Minnesota law, you must wait 48 hours (excluding weekends and holidays) after you’ve submitted your dig information to begin your digging project. Electrical All electrical must be approved by State Electrical Inspector. For electrical permit inquiries please contact the Department of Labor & Industry. www.dli.mn.gov dli.electricity@state.mn.us / (651) 284-5026 Reviewed for Code Compliance By: Date: This review is limited to the submitted scope of work, is based upon the supposition that the plan accurately depicts the intended construction and end-use, that the necessary legal authority has been obtained to construct the project and work is subject to code compliance and field inspection during construction. Permit #:Code Edition: Occupancy Classification: Type of Construction:DerrickWyman 4/23/2026 26SP-00001 N/A IRC-1 Single Family Dwelling 2020 MN Residential Code Separate Permits Required For: X X X X Electrical Mechanical Plumbing Fireplace Demolition Fire Suppression System Septic Registered Plans All construction shall comply with the approved plans. Construction details in plans prepared and certified by registered design professionals cannot be altered without prior written approval from the designer of record and review & approval from the Department of Building Safety. Submit all plan revisions to the Department of Building Safety for review, prior to their construction. REFER TO APPROVAL LETTER FOR ADDITONAL COMMENTS AND REQUIREMENTS Adhered Masonry Veneer shall be installed in accordance with manufacturer's instructions, Lath Inspection required. THIS FOUNDATION WAS REVIEWED AND APPROVED UNDER PERMIT # 26SP-00019. REFER TO PERMIT 26SP-00019 FOR APPROVED FOUNDATION PLANS AND NOTES. Beams require bearing under the full width of the beam. 7" beam requires 8"x8" post. 6"x6" does not provide a bearing width of 7". Beams require bearing under the full width of the beam. 7" beam requires 8"x8" post. 6"x6" does not provide a bearing width of 7". Manufacturer's Installation Instructions Shall Be Followed And Available To The Field Inspector At Time Of Inspection. 1,296.556 sf Install draft stopping consisting of minimum 1/2-inch drywall or 3/8-inch wood structural panel parallel to floor framing so concealed space does not exceed 1000 ft sq. Draft-stopping shall divide concealed spaces into approximately equal areas. The integrity of draft-stopping shall be maintained. << Draft Stop Required >><< Draft Stop Required >><< Draft Stop Required >><< Draft Stop Required >><< Draft Stop Required >><< Draft Stop Required >> All vehicle access doors (overhead doors) must be rated to withstand 115 M.P.H Ultimate wind loads. Approved assemblies must be marked/labeled as compliant with ANSI/DASMA108. Door specific wind rating drawing and Manufacturer's instructions must be present on site for building inspector. Garage and it's attic is required to be separated from the dwelling and its attic by not less than 1/2-inch gypsum fastened per Table R702.3.5 If dwelling extends above garage, then garage ceiling to be protected with not less than 5/8-inch Type X gypsum attached perpendicular to the framing using minimum 1 7/8" 6d nails or equivalent screws 6" o.c. All structure that supports required separation is to be protected with 1/2" Gypsum fastened per Table R702.3.5 Fire-blocking. In combustible construction, fire-blocking shall be provided to cut off all concealed draft openings (both vertical and horizontal) and to form an effective fire barrier between stories, and between a top story and the roof space. Fire-blocking shall be provided in wood-frame construction in the following locations: •In concealed spaces of stud walls and partitions, including furred spaces and parallel rows of studs or staggered studs, as follows: Vertically at the ceiling and floor levels. Horizontally at intervals not exceeding 10 feet. •At all interconnections between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings and cove ceilings. •In concealed spaces between stair stringers at the top and bottom of the run. •At openings around vents, pipes, ducts, cables and wires at ceiling and floor level, with an approved material to resist the free passage of flame and products of combustion. •At chimneys and fireplaces per Section R1003.19. •At cornices in two family dwellings at the line of dwelling separation. << Draft Stop Required >><< Draft Stop Required >><< Draft Stop Required >><< Draft Stop Required >><< Draft Stop Required >><< Draft Stop Required >> Attic Access Required, Builder to Locate Provide attic access to enclosed attic areas 30sq' or greater with a ceiling height 30" or greater. Access shall be 22"x30" and placed in a readily accessible location. If placed in a wall, the access shall be a minimum of 22" wide by 30" tall Exterior non-draining foundation insulation shall be covered with a 6-mil polyethylene slip sheet over the entire exterior surface. Rim Minimum R-20 Floor Minimum R-30 Trusses with an uplift force greater than 200 pounds shall be attached to wall assembly with metal connectors capable of resisting minimum uplift force of the values given in the truss design drawings. Provide individual truss drawings at time of framing inspection.