Permits - Permit# 26SP-00043 - 4201 Sunset Drive - #213 - 6/3/2026 City of Spring Park Mechanical (Commercial)
4349 Warren Ave, Spring Park, MN 55384
PR1NG PARK 26SP-00043
n La a Minneton a Phone:(952)471-9051 Fax:(952)471-9160
For Inspections: (952) 442-7520
Date Issued: 06/03/2026 Property Owner: PAUL MORALES
Expiration Date: 11/30/2026 Mailing Address: 4201 SUNSET DR#N213
Job Site Address: 4201 SUNSET DR#N213, SPRINK
PARK, MN 55384 SPRING PARK, MN 55384
Category: Commercial Miscellaneous Phone: (612)636-9220
Permit Type: Mechanical (Commercial) Email:
Valuation: $6,800.00
Description of Work:
Gas fireplace(25,000 BTU) Heat&Glo SL-7-IFT
Subdivision: THE MIST A CONDOMINIUM Required Setbacks:
Parcel ID: 18-117-23-44-0147
Filing:
Lot: Actual Setbacks:
Block:
Total Sq Ft:
Contractors: Fee Items Amount
Primary HEARTH & HOME TECHNOLOGIES (651) State Surcharge $3.40
842-4228 Commercial Mechanical Permit
Mechanical HEARTH & HOME TECHNOLOGIES (651) $ 191.25
842-4228 Commercial Mechanical Plan Review $ 124.31
Total Fees: $318.96
NOTICE
Signature of Applicant/Date Building Department Signature/Date
06/03/2026
MUST BE POSTED ON JOB SITE
INSPECTION CARD
4 i=z City of Spring Park
SPRING PARK
OnGakeMinnetonka 4349 Warren Ave, Spring Park, MN 55384
POST THIS CARD IN A SAFE CONSPICUOUS LOCATION.PLEASE DO NOT REMOVE THIS NOTICE UNTIL ALL REQUIRED INSPECTIONS ARE MADE AND SIGNED OFF BY THE APPROPRIATE
AUTHORITY AND THE BUILDING IS APPROVED FOR OCCUPANCY.STAMPED APPROVED PLANS MUST BE AVAILABLE ON THE JOBSITE.
Mechanical
PERMIT NO.: 26SP-00043 PERMITTYPE: (Commercial) ISSUED DATE: 06/03/2026 EXPIRATION DATE: 11/30/2026
18-117-23-
PROJECT ADDRESS: 4201 SUNSET DR#N213,SPRINK PARK,MN 55384 PARCEL NO.: 44-0147
OWNER: PAUL MORALES OWNER PHONE: (612)636-9220
CONTRACTOR: HEARTH&HOME TECHNOLOGIES CONTRACTOR PHONE: (651)842-4228
FIRESIDE HEARTH&HOME
APPLICANT: TECHNOLOGIES,INC. APPLICANT PHONE: (651)842-4228
DESCRIPTION OF WORK: Gas fireplace(25,000 BTU)Heat&Glo SL-7-IFT
CONSTRUCTION TYPE: OCCUPANT LOAD:
DATE DATE
INSPECTION INSP PASSED COMMENTS INSPECTION INSP PASSED COMMENTS
Mechanical Rough-In Fire/Smoke Damper
Air/Hydrostatic Test Rough-In
Duct Leakage Test Types 1&2 Hood
(Types 1&2 Hood) Rough-In
Reports Duct Fire Wrap
Mechanical Final
Fire Approval: Date: Engineering Date:
Approval:
PW Approval: Date: Other( ): Date:
To request an inspection:(952)442-7520
Page 1 of 1
City of Spring Park
4349 Warren Ave
Spring Park, MN 55384
Phone(952)471-9051
PRING PARK Fax(952)471-9160
n Lake Minnetonka
Project Name:
Date: 06/02/2026 Approval Status: Approved As Is
Jurisdiction: City of Spring Park Construction Type:
ID: 26SP-00043 Applicant Name: FIRESIDE HEARTH & HOMETECHNOLOGIES, INC.
Applicant Phone: (651)842-4228 Applicant Email:
Jobsite: 4201 SUNSET DR#N213
Code: 2020 1300, Minnesota Building Code Administration; 2020 1305, Minnesota Building Code
Reviewed: Mechanical
The plans and specifications,for the project named above, have been reviewed for substantial compliance with the
current Minnesota State Building Code. This review is limited to the submitted scope of work; is based upon the
supposition that the data on which the design is based are correct and that the necessary legal authority has been
obtained to construct the project.Although every attempt has been made to identify code issues or concerns for proper
and necessary change,the project designer(s), the building contractor(s) and the property owner(s)are ultimately
responsible for providing complete code compliance and maintaining minimum construction standards for the
safeguarding of life or limb, health, public welfare and property while constructing this project.
Approval is based on the correction of all noted deficiencies and compliance with all items listed below. Any changes from
these documents and/or additional information shall be submitted to the Department of Building Safety for code
compliance review and approval. Written response of approval must be on site prior to implementation of such changes.
The following information is related to the submitted plans/scope or as general information regarding code compliance.
Compliance with the stated requirements will be verified during the construction process.
All work shall be inspected. It is the responsibility of the contractor/installer to contact the Department of Building Safety,
when ready to schedule an inspection, at(952)442-7520 during regular business hours.
If you have any questions or concerns regarding this plan review, please contact me via telephone at(952)442-7520 or
email at codereview@mnspect.com.
Derrick Wyman
Plans Examiner
dwyman@safebuilt.com
4201 SUNSET DR#N213 Page 1
City of Spring Park
4349 Warren Ave
Spring Park, MN 55384
Phone(952)471-9051
WRING PARK Fax(952)471-9160
n La fie Minneton a
Plan Specific Items:
Mechanical:Approved As Is- Derrick Wyman, dwyman@safebuilt.com
4201 SUNSET DR#N213 Page 2
Read all attached The field copy of these plans must Plan Revisions
materials. be kept on-site and made
available to inspector during all All construction shall
inspections. comply with the approved
Everyone performing laps,
work to which the code To schedule inspections call
is applicable shall (952) 442-7520 Plan revisions will not be
I with the code. reviewed in the field without
comply y Please have the permit number prior approval from the
and street address ready at the Building Official. Submit all
time of the call. plan revisions to the
Department of Building
Safety for review, prior to
their construction.
NOTICE
Plan review was done in accordance with the current
Minnesota Building Code. Plan review does not waive any
additional code compliance issues found on site.
REFER TO APPROVAL LETTER SCOPE OF WORK:
FOR ADDITONAL COMMENTS AND Install new Gas fireplace (25,000 BTU)
REQUIREMENTS Heat & Glo SL-7-IFT
Reviewed for Code Compliance Separate Permits
Required For:
This review is limited to the submitted scope of work, is based upon the supposition that the plan Electrical
accurately depicts the intended construction and end-use, that the necessary legal authority has
been obtained to construct the project and work is subject to code compliance and field Mechanical
inspection during construction. Plumbing
By: Verrickv man Type of Construction: V-B Fireplace
Demolition
Date: 6/2/2026 Occupancy Classification: R-2 Fire Suppression System
Septic
Permit#: 26SP-00043 Code Edition: 2020 MN Building Code �' Building
4201 Sunset Dr#N213, Spring Park, Minnesota 55384
_i A
O
E
F MEASURE FROM TOP OF
APPLIANCE OPENING
B i\
H
D
J�
`MINIMUM FRAMING DIMENSIONS
A B C D E F G H I J
DVP Pipe SLP Pipe **DVP Pipe SLP Pipe
Models Rough Rough Clearance ***Combustible ****Minimum Behind Sides of Front of
Rough Rough Opening Rough Rough Opening to Room Hearth
Opening Opening (Height) Opening Opening (Width) Ceiling Floor Required Appliance Appliance Appliance
(Width) (Width) (Depth) (Depth)
SL-S-IFT n. 10 8-5/8 34-3/4 16-1/4 16-1/4 37 32 0 0 1/2 1/2 36
mm 254 219 882 413 413 940 813 0 0 13 13 914
in. 10 8-5/8 38-1/4 16-1/4 16-1/4 42 32 0 0 1/2 1/2 36
SL-7-IFT
mm 254 219 972 413 413 1067 813 0 0 13 13 914
in. 10 8-5/8 40-1/4 16-1/4 16-1/4 49 32 0 0 1/2 1/2 36
SL-9-IFT
mm 254 219 1022 413 413 1245 813 0 0 13 13 914
*Adjust framing dimensions for interior sheathing(such as sheetrock)
**Add 12 inches when rear venting with one 900 elbow.
***When using combustible flooring materials, such as carpeting and padding,the combustible flooring material must not extend
higher than one inch from the base of the appliance when the appliance is mounted at floor level.
****For installations with vinyl flooring,see Section 3.D.
Figure 3.10 Clearances to Combustibles
18 Heat&Glo * SL-5/51-P-IFT,SL-7/71-P-IFT,SL-9/9LP-IFT Installation Manual • 2632-980 Rev.H • 5/23
C. Constructing the Appliance Chase
NOTICE:Install appliance on hard metal or wood surfaces
extending full width and depth. DO NOT install directly on
carpeting, vinyl, or any combustible material other than
wood.
WARNING! Risk of Fire! Maintain specified air space
clearances to appliance and vent pipe:
• Insulation and othermaterials must be secured to prevent A
accidental contact.
• The chase must be properly blocked to prevent blown 1 1
insulation or other combustibles from entering and 3 IN.MIN. —_B'
making contact with fireplace or chimney. T
• Failure to maintain airspace may cause overheating and
a fire. SL-5-IFT=42-3/4 IN.
SL-7-IFT=46-1/4 IN.
SL-9-IFT=48-1/4 IN.
A chase is a vertical box-like structure built to enclose the
gas appliance and/or its vent system. In cooler climates
the vent should be enclosed inside the chase.
NOTICE: Treatment of ceiling firestops and wall shield
firestops and construction of the chase may vary with the °
type of building. These instructions are not substitutes
for the requirements of local building codes. Therefore,
you MUST check local building codes to determine the
requirements to these steps.
NOTICE:Where required by code,install only sprinkler
heads with a sprinkler activation temperature classified =REQUIRED MINIMUM OFF TOP=0 IN.
as Extra High. *NOTE: If overhang"A"is less than 2 inches,clearance from
top of termination cap to bottom of overhang"B"MUST be a
• Sprinklers inside of chase: Keep sprinkler head away minimum of 4 inches. If"A"is two inches or greater,see Figure
from vent and chimney. 4.5,"Minimum Clearances for Termination.
• Heat Management applications: Maintain 36 inches of
clearance to openings from which heat is discharged Figure 3.11 Exterior Chase-Minimum Height Requirements
such as convection slots, passive heat registers, heat
zone registers, etc. Refer to Section 6.8 for Heat
Management options allowed for this appliance.
Chases should be constructed and insulated in the same
manner as the thermal envelope of the home based on
the code requirements for that climate zone to prevent air
leakage and draft problems.The chase is an extension of
the building thermal envelope.
To further prevent drafts and air leakage, the wall shield D. Floor Protection
and ceiling firestops should be sealed with caulk with
a minimum of 300 OF continuous exposure rating to Vinyl Flooring
seal gaps. Gas line holes and other openings should
be sealed with caulk with a minimum of 300 OF continu- Vinyl flooring is sensitive to heat. Hearth and Home
ous exposure rating or stuffed with unlaced insulation. If the Technologies does not recommend adhesive based vinyl
appliance is being installed on a cement surface, a layer of flooring due to thermal expansion. Floating-style flooring
plywood may be placed underneath to prevent conducting can be used, but will reach temperatures up to 110 OF in a
cold up into the room. room with ambient temperature of 70 OF. Consult flooring
Minimum height requirements for an exterior chase on a top-
specifications to ensure compatibility.
vented appliance are shown in Figure 3.11. Reference Fig-
ure 4.5 for additional clearances.
Heat&Go • SL-5/5LP-IFT,SL-7/7LP-IFT,SL-9/91_13-IFT Installation Manual • 2632-980 Rev.H • 5/23 19
C. Vent Terminal Clearances ® =AREA WHERE TERMINAL IS NOT PERMITTED
OX =AIR SUPPLY INLET
I "
c y �V =VENT TETel
L
I� V K Electrical K V
H or I Service
o U V V
V M H C
V VHV OI
A
A V
U.S.A.Installations: In accordance with the current ANSI Z223.1/NFPA 54,National Fuel Gas Code.
Canadian Installations: In accordance with the current CSA B149.1,Natural Gas and Propane Installation Code.
U.S.A. CANADA
A clearance above grade,veranda, porch,deck,balcony or roof. 12 in. (305 mm) 12 in. (305 mm)
B clearance to window or door that may be opened,or to permanently closed window 9 in min. 12 in.min.
(229 mm min.) (305 mm min.)
clearance below unventilated soffit 18 in. (457 mm) 18 in. (457 mm)
C clearance below ventilated soffit 18 in. (457 mm) 18 in. (457 mm)
clearance below any vinyl soffits and electrical service 30 in. (762 mm) 30 in. (762 mm)
D clearance to outside corner 6 in. (152 mm) 6 in. (152 mm)
E clearance to inside corner 6 in. (152 mm) 6 in. (152 mm)
Clearance in accor- 3 ft(914 mm)
dance with local in- within a height 15
F clearance to each side of center line extended above gas meter/regulator assembly stallation codes and ft(4.5 m)above
the requirements of the meter/regula-
the gas supplier. for assembly
G clearance to gas service regulator vent outlet 3 ft(914 mm) 3 ft(914 mm)
H clearance to non-mechanical air supply inlet to building or the combustion air inlet to 9 in min. 12 in.min.
any other appliance termination(mechanical or non-mechanical) (229 mm min.) (305 mm min.)
clearance to a mechanical(powered)air supply inlet
I ***(All mechanical air intakes within 10 feet of a horizontal termination cap must be 3 ft(914 mm)*** 6 ft(1.8 m)
a minimum of 3 feet below termination.)
On public property: clearance above paved sidewalk or a paved driveway. 7 ft (2.1 m) 7 ft(2.1 m)**
J
**(A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings
and serves both dwellings.)
clearance from sides of electrical service 6 in. (152 mm) 6 in. (152 mm)
K
Location of the vent termination must not interfere with access to the electrical service.
clearance above electrical service 12 in. (305 mm) 12 in. (305 mm)
L
Location of the vent termination must not interfere with access to the electrical service.
clearance under veranda,porch,deck,balcony or overhang
*(Permitted only if veranda, porch,deck,or balcony is fully open on a minimum of 18 in. (457 mm) 12 in.(305 mm)*
M two sides beneath the floor.)
vinyl or composite overhang 42 in.(1.1 m) 42 in.(1.1 m)
Figure 4.5 Minimum Clearances for Termination
22 Heat&Glo • SL-5/5LP-IFT,SL-7/7LP-IFT,SL-9/9LP-IFT Installation Manual • 2632-980 Rev.H • 5/23
D. Use of Elbows
Diagonal runs have both vertical and horizontal vent as-
pects when calculating the effects. Use the rise for the
vertical aspect and the run for the horizontal aspect. See
Figure 4.6. I Y
Two 450 elbows may be used in place of one 901 elbow. I
On 451 runs, one foot of diagonal is equal to 8-1/2 inch I
(216 mm) horizontal run and 8-1/2 inch (216 mm)vertical
run.A length of straight pipe is allowed between two 450 I — _
elbows. See Figure 4.6.
Figure 4.7 shows the vertical and horizontal offsets for X I,(—
DVP or SLP elbows.
Vent X Y
Type Inches Millimeters Inches Millimeters
DVP 6-5/8 168 16-1/2 419
i
SLP 5-1/4 133 11-3/8 289
i
i
VERTICAL
y - - — — — — — —
Lu
—
�Q��O W
RUN x
I
77- --
°
i
I
I _ _
HORIZONTAL I —
I
E— X
SLP Effective Length Rise/Run
Pipe Inches Millimeters Inches Millimeters X
SLP4 4 102 2-3/4 70 Vent Type
Inches Millimeters
SLP6 6 152 4-1/4 108 DVP 16-1/4 413
SLP12 12 305 8-1/2 216 SLP 11-1/4 286
SLP24 24 610 17 432
SLP36 36 914 25-1/2 648
SLP48 48 1219 34 864 Figure 4.7 Vertical and Horizontal Offset for DVP and SLP Elbows
SLP6A 3 to 6 76 to 152 2-1/8-4-1/4 54-108
SLP12A 3 to 12 1 76 to 305 2-1/8-8-1/2 1 54-216
DVP Effective Length Rise/Run
Pipe Inches Millimeters Inches Millimeters
DVP4 4 102 2-3/4 70
DVP6 6 152 4-1/4 108
DVP12 12 305 8-1/2 216
DVP24 24 610 17 1 432
DVP36 36 914 25-1/2 648
DVP48 48 1219 34 864
DVP6A 3 to 6 76 to 152 2-1/8-4-1/4 54-108
DVP12A 3 to 12 t 76 to 305 2-1/8-8-1/2 54-216
Figure 4.6
Heat&Glo • SL-5/5LP-IFT,SL-7/71-13-IFT,SL-9/9LP-IFT Installation Manual 2632-980 Rev. H 5/23 23
E. Use of Flex Vent (SLP-FLEX Series 6-5/8
Inch)
The flex vent must be supported with the spacing between
support intervals not exceeding 4 feet, with no more than
1/2 inch sag between supports.
A support is required at each change in venting direction,
and in any location where it is necessary to maintain the
necessary clearance to combustibles. A simple "up and
out'installation (Figure 4.8)requires only enough support
to maintain the necessary clearance to combustibles.
However, the vent attachment point and the firestop loca-
tion are considered to be supports.
TERMINATION
3 in.CLEARANCE CAP
FLEX-VENT
____T 1 in.
CLEARANCE
Figure 4.8 Flex Vent Pipe-Generic Fireplace Shown
24 Heat&Glo • SL-5/5LP-IFT,SL-7/7LP-IFT,SL-9/9LP-IFT Installation Manual 2632-980 Rev.H 5/23
F. Vent Diagrams Measuring Standards:
General Rules: Vertical and horizontal measurements listed in the vent
• SUBTRACT 3 ft.from the total H measurement for each diagrams and clearances for termination were made
900 elbow installed horizontally.
using the following standards:
• SUBTRACT 1-1/2 ft. from the total H measurement for
• Pipe measurements are shown using the effective length
each 450 elbow installed horizontally. of pipe. See Section 12.A(Figure 12.1 for DVP, Figure
12.9 for SLP)for information on effective length of pipe
• Rear Vented: A maximum of three 900 elbows(or six 451 components.
elbows) may be used in any vent configuration. Some . Horizontal terminations are measured to the outside
elbows may be installed horizontally. See Figure 4.23
mounting surface (flange of termination cap) See
and 4.26. Figure 4.10
• Top Vented: A maximum of four 90°elbows(or eight 45" . Vertical terminations are measured to top of last section
elbows) may be used in any vent configuration. Some
elbows may be installed horizontally. See Figure 4.19. of pipe. See Figure 4.11.
• Elbows may be placed back to back anywhere in the
• Horizontal pipe installed level with no rise.
system.
• Any 901 elbow may be replaced with two back to back
450 elbows.
• When penetrating a combustible wall, a wall shield -
firestop must be installed.
• When penetrating a combustible ceiling,a ceiling firestop
must be installed.
• Horizontal runs of vent do not require vertical rise;
horizontal runs may be level. o
• Horizontal termination cap should have a 1/4 inch
4
H
downward slant to allow any moisture In cap to be
released. See Figure 4.9.
OQIe
MEASURE TO SHADED SURFACE
(OUTSIDE MOUNTING SURFACE)
Figure 4.10 Measure to Outside Mounting Surface F
I W
IAI
L
L
I
I I
1/4 in,max. I I
(6 mm) I
I I
4 D
4 Figure 4.9
Figure 4.11 Measure to Top of Last Section of Pipe
Heat&Glo SL-5/51-P-IFT,SL-7/71-P-IFT,SL-9/9LP-IFT Installation Manual • 2632-980 Rev. H • 5/23 25
(_gM;4 , ,CC 5/1yl
City of Spring Park COMMERCIAL MECHANICAL
4349 Warren Ave. PERMIT APPLICATION
Spring Park, MN 55384
City: 952-471-9051 MNSPECT: 952-442-7520 �����
Permit Number: CQ
Job Address I Su b Uz i f 9J3 Owner's Phone
Owner's Name Au� /71 Business Name
Owner's Address yet) S"`4.1S,,/ bF (i / 91 S City/State/Zip � `'`%
Mechanical Contractor __Phone
Address,?&V PA((e yi e-L-1 llvc /1,/ City/State/Zip A§Gcic
State Bond No.AL36(o,'�5 7;�- Gas Fitters License No. 4)nO 90efo
CHECK TYPE OF WORK: ❑ New Construction ❑ Addition ❑ Alterat ion Replacement
Furnace Air Cond In Floor Heat Air Exch Fireplace Exhaust Fan
Boiler Wall Heater Rooftop Unit Unit Heater Range Hood Make-Up Air
Equipment Efficiency
System
Mfg.& Equipment Heating Cooling
g� ) Model Rated Rated Minimum Rated Rated Minimum Econ. Min.
Tag(s)s No Type Capacity Effli�ciency Efficiency Capacity Efficiency Efficiency Efficiency
VALUATION OF WORK$ "00' co VALUATION APPROVED$
1 hereby certify that l have read and examined this application and know the same to be true and correct. All provisions of laws and
ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume
to give authority to violate or cancel the provisions of any other state or local law regulating construction or the performance of
construction. I agree to pay all plan review fees even if 1 choose not to proceed with the work. I certify all taxes and Municipal fees owed
in connection with this property are current.
Applicant's ` "nature Date
OFFICE USE ONLY
Permit Fee ........................... 19 t .o"tS Plans checked by:
Code Review 1
State Surcharge ..................
Other.................................. � Date: CO oZ
Total Permit Charge $
Jamie Hoffman
From: payment=thepaymentgroup.com@mg.thepaymentgroup.com on behalf of
payment@thepaymentgroup.com
Sent: Wednesday, June 3, 2026 7:50 AM
To: Jamie Hoffman
Cc: payment@thepaymentgroup.com
Subject: DOUG CARLSON Permit Payment to Spring Park, MN - Permits & Licenses from TPG
ATTENTION: if you need assistance with this payment, please FORWARD this email to
tpgclientsupport@nuvei.com and include your request. Your client manager will respond.
Dear Spring Park, MN - Permits & Licenses,
CHRISTA WEGWART has made a web Payment through The Payment Group for:
Payment Information
Date Paid: Wednesday, 03 June 2026 07:50:22 CT
Confirmation: CYFVM4
Credit Card Number(last 4 4616
digits):
Credit Card Type: MasterCard
Full Address - Permit or
Business Payment
First Name Last Name Name City, State & License Amount
Zip Number
FIRESIDE 4201 SUNSET
DOUG CARLSON HEARTH & DRIVE #213,SPRING PARK, 26SP-00043 $318.96
HOME
MN, 55384
CHRISTA WEGWART can be reached at : 651-842-4228 or roseville_builder_ops@hnicorp.com if
there are any questions regarding this payment.
Click here to login to your The Payment Group admin account
Thank you once again for choosing The Payment Group!
1
RECEIPT
City of Spring Park
4349 Warren Ave, Spring Park, MN 55384
(952)471-9051
SPRING PARK
26SP-00043 1 Mechanical (Commercial) On Lake 914innetonka
Receipt Number:562
Payment Amount: $318.96 June 3,2026
Transaction Method Payer Cashier Reference Number
Credit Card Fireside Hearth and Home Jamie Hoffman CYFVM4
Comments
Assessed Fee Items
Fee items being paid by this payment
Assessed Fee Item Account Code Assessed Amount Paid Balance Due
On
06/02/26 State Surcharge $3.40 $3.40 $0.00
06/02/26 Commercial Mechanical Plan Review $124.31 $124.31 $0.00
06/02/26 Commercial Mechanical Permit $191.25 $191.25 $0.00
Totals: $318.96 $318.96
Previous Payments $0.00
Remaining Balance Due $0.00
Application Info
Property Address Property Owner Property Owner Address Valuation
4201 SUNSET DR#N213 PAUL MORALES 4201 SUNSET DR#N213 $6,800.00
SPRINK PARK, MN 55384 SPRING PARK, MN 55384
Description of Work
Gas fireplace(25,000 BTU) Heat&Glo SL-7-IFT