Loading...
Permits - Permit# 25SP-00073 - Plan Revision - 4365 Warren Avenue - 6/4/2026Read all attached materials. Everyone performing work to which the code is applicable shall comply with the code. BEFORE YOU DIG Contact Gopher State One Call to locate buried utilities. 651-454-0002 or 800-252-1166 http://www.gopherstateonecall.org/ In accordance with Minnesota law, you must wait 48 hours (excluding weekends and holidays) after you’ve submitted your dig information to begin your digging project. Approved lateral load connections are required at connection of deck to house. Deck footings require inspection after excavation of all footings is complete but prior to placing any concrete. Minimum concrete compressive strength of 2500psi required. The field copy of these plans must be kept on-site and made available to inspector during all inspections. To schedule inspections call (952) 442-7520 Please have the permit number and street address ready at the time of the call. Deck Ledger to be positively bolted to structure following the requirements of Table R507.9.1.3(1) and Table R507.9.1.3(2) All fasteners shall be hot dipped galvanized or stainless steel and shall be installed in accordance with Figures R507.9.1.3(1) and R507.9.1.3(2) Install corrosion resistance flashing above all ledgers and seal sides and bottom with approved sealants. If using alternate fasteners provide manufacturer's specifications to inspector at time of framing inspection. REFER TO APPROVAL LETTER FOR ADDITONAL COMMENTS AND REQUIREMENTS Reviewed for Code Compliance By: Date: This review is limited to the submitted scope of work, is based upon the supposition that the plan accurately depicts the intended construction and end-use, that the necessary legal authority has been obtained to construct the project and work is subject to code compliance and field inspection during construction. Permit #:Code Edition: Occupancy Classification: Type of Construction:DerrickWyman 6/2/2026 25SP-00073 V-B R2 2020 MN Building Code Building size is 26 x 40.5 with 6' gables in two sides. Entry decks are 4x8 with steps to grade. Items written in blue were provided via email conversation by Brian Chou on 9/26/2025. Approved lateral load connections are required at connection of deck to house. All columns resting on footings require lateral restraint by means of mechanical connections or 12" embedment in concrete or surrounding soils. (MN Rules 1309.R507.4.1) Girder/Beam plies shall be fastened together according to MRC Table R602.3 (1) or according to engineered lumber manufacturer's published installation instructions. Deck beams shall be attached to supports in a manner capable of transferring vertical loads and resisting horizontal displacement. Deck beam connections to wood posts shall be in accordance with Figures R507.5.1(1) and R507.5.1(2). Manufactured post-to-beam connectors shall be sized for the post and beam sizes. Bolts shall have washers under the head and nut. (MN Rules1309.R507.5.2) The ends of beams shall have not less than 1-1/2 inches of bearing on wood or metal and not less than 3 inches of bearing on concrete or masonry for the entire width of the beam. (MN Rules 1309.R507.5.1) Lateral Load Connectors Required When installing in accordance with Figure R507.9.2(1), install not less than two (2) within 24" of each end of the deck. When installing in accordance with Figure R507.9.2(2), install not less than four (4) devices with a minimum load rating of 750lbs each. TABLE R507.9.1.3(1) DECK LEDGER CONNECTION TO BAND JOIST a (Deck live load = 40 psf, deck dead load = 10 psf For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa. a. Ledgers shall be flashed in accordance with Section R703.4 to prevent water from contacting the house band joist. b. The tip of the lag screw shall fully extend beyond the inside face of the band joist. c. Sheathing shall be wood structural panel or solid sawn lumber. d. Sheathing shall be permitted to be wood structural panel, gypsum board, fiberboard, lumber, or foam sheathing. Up to 1/2-inch thickness of stacked washers shall be permitted to substitute for up to 1/2 inch of allowable sheathing thickness where combined with wood structural panel or lumber sheathing. CONNECTION DETAILS JOIST SPAN 6 and less 6 1 to 8 81 to 10 101 to 12 121 to 14 141 to 16 161 to 18  On-center spacing of fasteners 1/2-inch diameter lag screw with 1/2-inch maximum sheathingb, c 30 23 18 15 13 11 10 1/2-inch diameter bolt with 1/2-inch maximum sheathingc 36 36 34 29 24 21 19 1/2-inch diameter bolt with 1-inch maximum sheathingd 36 36 29 24 21 18 16 >> M N M N M N M N M N M N TABLE R507.9.1.3(2) PLACEMENT OF LAG SCREWS AND BOLTS IN DECK LEDGERS AND BAND JOISTS   For SI: 1 inch = 25.4 mm. a. Lag screws or bolts shall be staggered from the top to the bottom along the horizontal run of the deck ledger in accordance with Figure R507.9.1.3(1). b. Maximum 5 inches. c. For engineered rim joists, the manufacturer’s recommendations shall govern. d. The minimum distance from bottom row of lag screws or bolts to the top edge of the ledger shall be in accordance with Figure R507.9.1.3(1). MINIMUM END AND EDGE DISTANCES AND SPACING BETWEEN ROWS TOP EDGE BOTTOM EDGE ENDS ROW SPACING Ledgera 2 inchesd3/4 inch 2 inchesb 15/8 inchesb Band Joistc3/4 inch 2 inches 2 inchesb 15/8 inchesb