Permits - Permit# 26SP-00049 - 4154 Shoreline Drive - 6/26/20261NG PARK City of Spring Park I Fire Suppression (Commercial) 4349 Warren Ave, Spring Park, MN 55384 Phone:(952) 471-9051 Fax: (952) 471-9160 For Inspections: (952) 442-7520 26SP-00049 Date Issued: 06/26/2026 Property Owner: CORNERSTONE INVESTORS ET AL / Expiration Date: 12/23/2026 CORNERSTONE INVESTORS LLC / TONKA VENTURES LLC Job Site Address: 4154 SHORELINE DR, STE 200, SPRING PARK, MN 55364 Mailing Address: 102 JONATHAN BLVD N #200 Category: Fire Permit Type: Fire Suppression (Commercial) CHASKA, MN 55318 Valuation: $4,070.00 Phone: (612) 723-0783 Email: cole@cornerstone-mn.com Description of Work: Relocate 13 pendant sprinkler heads for the ceilings & walls Subdivision: Required Setbacks: Parcel ID: 18-117-23-44-0038 Filing: Actual Setbacks: Lot: Block: Total Sq Ft: Contractors: Fee Items Amount Primary THE FIRE GROUP, INC (651) 302-3977 State Surcharge $ 2.04 Fire THE FIRE GROUP, INC (651) 302-3977 Commercial Fire Permit $ 155.75 Commercial Fire Plan Review $ 101.24 Total Fees: $ 259.03 NOTICE Signature of Applicant/Date Building Department Signature/Date 06/26/2026 MUST BE POSTED ON JOB SITE INSPECTION CARD *Az� City of Spring Park SPRING PARK OnGa�f%innetonka 4349 Warren Ave, Spring Park, MN 55384 POST THIS CARD IN A SAFE CONSPICUOUS LOCATION. PLEASE DO NOT REMOVE THIS NOTICE UNTIL ALL REQUIRED INSPECTIONS ARE MADE AND SIGNED OFF BY THE APPROPRIATE AUTHORITY AND THE BUILDING IS APPROVED FOR OCCUPANCY. STAMPED APPROVED PLANS MUST BE AVAILABLE ON THE JOBSITE. Fire Suppression PERMIT NO.: 26SP-00049 PERMIT TYPE: (Commercial) ISSUED DATE: 06/26/2026 EXPIRATION DATE: 12/23/2026 PROJECT ADDRESS: 4154 SHORELINE DR, STE 200, SPRING PARK, MN 55364 CORNERSTONE INVESTORS ET AL OWNER: / CORNERSTONE INVESTORS LLC / OWNER PHONE: TONKA VENTURES LLC CONTRACTOR: THE FIRE GROUP, INC CONTRACTOR PHONE: THE FIRE GROUP INC - Dan Del APPLICANT: Monico APPLICANT PHONE: DESCRIPTION OF WORK: Relocate 13 pendant sprinkler heads for the ceilings & walls (612)723-0783 (651) 302-3977 (651) 302-3977 18-117-23- PARCEL NO.: 44-0038 CONSTRUCTION TYPE OCCUPANT LOAD: DATE DATE INSPECTION INSP PASSED COMMENTS INSPECTION INSP PASSED COMMENTS Fire Suppression Fire Suppression Final Rough -IN Fire Approval: PW Approval: To request an inspection: (952) 442-7520 Date: Engineering Approval: Date: Other ( Date: Date: Page 1 of 1 .1" PARK City of Spring Park 4349 Warren Ave Spring Park, MN 55384 Phone (952) 471-9051 Fax (952) 471-9160 Project Name: Date: 06/19/2026 Approval Status: Approved with Comments Jurisdiction: City of Spring Park Construction Type: ID: 26SP-00049 Applicant Name: THE FIRE GROUP INC - Dan Del Monico Applicant Phone: (651) 302-3977 Applicant Email: dan.delmonico@thefiregroupinc.com Jobsite: 4154 SHORELINE DR, STE 200 Code: Reviewed: Fire Sprinkler The plans and specifications, for the project named above, have been reviewed for substantial compliance with the current Minnesota State Building Code. This review is limited to the submitted scope of work; is based upon the supposition that the data on which the design is based are correct and that the necessary legal authority has been obtained to construct the project. Although every attempt has been made to identify code issues or concerns for proper and necessary change, the project designer(s), the building contractor(s) and the property owner(s) are ultimately responsible for providing complete code compliance and maintaining minimum construction standards for the safeguarding of life or limb, health, public welfare and property while constructing this project. Approval is based on the correction of all noted deficiencies and compliance with all items listed below. Any changes from these documents and/or additional information shall be submitted to the Department of Building Safety for code compliance review and approval. Written response of approval must be on site prior to implementation of such changes. The following information is related to the submitted plans/scope or as general information regarding code compliance. Compliance with the stated requirements will be verified during the construction process. All work shall be inspected. It is the responsibility of the contractor/installer to contact the Department of Building Safety, when ready to schedule an inspection, at (952) 442-7520 during regular business hours. If you have any questions or concerns regarding this plan review, please contact me via telephone at (952) 442-7520 or email at codereview@mnspect.com. Derrick Wyman Plans Examiner dwyman@safebuilt.com 4154 SHORELINE DR, STE 200 Page 1 SPRING PARK .)n Lake :arnnelunl;,r Plan Specific Items: Fire Sprinkler: Approved with Comments - Derrick Wyman, dwyman@safebuilt.com PLANS DATED: 5/26/2026 PLAN SHEETS REVIEWED: 1 of 1 SCOPE OF WORK: Relocate 13 pendant sprinkler heads for the ceilings & walls SPRINKLER SYSTEM (Y/N & TYPE): NFPA 13 PLAN SPECIFIC ITEMS (to be completed during the construction process). 1. Sprinkler heads shall be not less than 6'-0" to each other. City of Spring Park 4349 Warren Ave Spring Park, MN 55384 Phone (952) 471-9051 Fax (952) 471-9160 2. A supply of at least six spare sprinklers (never fewer than six) shall be maintained on the premises so that any sprinklers that have operated or been damaged in any way can be promptly replaced. i. The sprinklers shall be kept in a cabinet located where the temperature to which they are subjected will not exceed 100°F. ii. One sprinkler wrench as specified by the sprinkler manufacturer shall be provided in the cabinet for each type of sprinkler installed to be used for the removal and installation of sprinklers in the system. iii. A list of sprinklers installed in the property shall be posted in the sprinkler cabinet and shall include the following: Sprinkler identification number if equipped; or the manufacturer, model, orifice, deflector type, thermal sensitivity, and pressure rating; General description; Quantity of each type to be contained in the cabinet; Issue date or revision date of the list. 3. Where flexible sprinkler hose fittings are used to connect sprinklers to branch lines in suspended ceilings, a label limiting relocation of the sprinkler shall be provided on the anchoring component. (NFPA 13-2016, Section 9.2.1.3.3.4) GENERAL ITEMS: 1. Construction or work shall be inspected in accordance with the requirements of Minnesota Rule 1300.0210. 2. It is the responsibility of the contractor/installer to contact the Department of Building Safety, when ready to schedule an inspection, at (952) 442-7520 between the hours of 8:00 a.m. and 4:30 p.m., Monday through Friday. 3. The approved permit and all related plans and documentation shall be on site and available to the inspector at the time of inspection. 4. Failure to provide the required documentation to the inspector at the time of inspection may result in a cancelation of the inspection and additional inspection fees for the additional inspection(s). 5. The field inspector may identify additional code requirements during inspections. (Example of code requirement items that might be identified are fire sprinkler heads being obstructed by framing, beams, lighting, ceiling configurations, plumbing pipes, and mechanical system ductwork that will require review by the fire suppression plan reviewer. Additional work being completed that is not consistent with the project scope of work or the approved plans.) 6. Applicable Codes: 2020 Minnesota State Building Code, 2020 Minnesota State Fire Code, NFPA 13-2016 4154 SHORELINE DR, STE 200 Page 2 A-r. PARK om City of Spring Park 4349 Warren Ave Spring Park, MN 55384 Phone (952) 471-9051 Fax (952) 471-9160 4154 SHORELINE DR, STE 200 Page 3 Bulletin 074 January 2023 Relmiabld Features • Standard coverage quick -response sprinklers • Upright, pendent, horizontal sidewall, and vertical sidewall deflectors • Low profile, compact design • Available in a wide variety of finishes Product Description Reliable Model F1 FR56 series sprinklers are quick -response standard spray automatic fire sprinklers utilizing a sensitive 3.0 mm glass bulb thermal element. Pendent and horizontal sidewall sprinklers may be installed exposed or surface mounted using escutcheons such as the Reliable Models B, C, or HB (reference Technical Bulletin 204). When installed recessed or concealed, the Model F1 FR56 series sprinklers are specifically listed with and may only be installed with listed Reliable escutcheons and cover plates. Refer to the technical information on the following pages for specific listings for recessed and concealed installations and refer to Figures 5 and 6 for dimensional information. When fitted with an approved water shield, these sprinklers may considered intermediate sprinklers for use in racks, below grated walkways, and other areas where intermediate level sprinklers are required. Table A provides a summary of the approvals and availability of specific Model F1 FR series sprinkler configurations. Additional technical information for each sprinkler model is provided on the following pages. F1 FR56 Series Quick Response Sprinklers K-factor 5.6 (80) Model F1 FR56 Pendent Model F1 FR56 Upright q� - 7T �ft' . FVAI Model F1 FR56 Vertical Sidewall Model F1 FR56 Horizontal Sidewall Note: Not all versions of the product are shown. Note: This bulletin may contain information on New and Legacy sprinklers that reflects a dimensional change only. Sprinkler Iden- tification Number (SIN), application, performance, and listings/ approval are not otherwise affected. Sprinklers with New frames will include the suffix "N" in the order. F1 FIR Series Sprinkler Summary Sprinkler K-Factor gpm/psl'R Max. Working Pressure Sprinkler Model (Ipm/bar'n) Orientation Listings & Approvals psi (bar) Identification Number (SIN) Upright cULus, FM, LPCB, VdS, 175 (12) RA1425 Intermediate Upright EC, WM, UKCA 250 (17) (cULus only) Pendent cULus, FM, LPCB, VdS, 175 (12) RA1414 EC, WM, UKCA 250 (17) (cULus only) Concealed Pendent cULus, VdS, EC, WM, 175 (12) RA1414 F1 FR56 5.6(80) UKCA 250 (17) (cULus only) Horizontal Sidewall cULus, FM 175 (12) 250 (17) (cULus only) RA1435 Vertical Sidewall cULus, FM, LPCB, 175 (12) RA1485 UKCA www.reliablesprinkler.com Technical Specifications Style: Upright, Intermediate Upright Threads: 1/2" NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) 250 psi (17 bar) (cULus only) Material Specifications Thermal Sensor: 3 mm Glass Bulb Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table B) Sensitivity Quick response Temperature Ratings 135°F (57°C) 155-F(68-C) 175-F (79-C) 200-F(93-C) 286-F (141 °C) Guards & Shields (New Frames) Factory Water Shield (cULus, FM) F-1 Guard (cULus, FM) F-3 Guard with Shield (cULus, FM) Guards and Shields (Legacy Frames) Factory Water Shield C-1 Guard (FM) C-3 Guard with Shield (cULus, FM) D-1 Guard (cULus) D-3 Guard with Shield (cULus) Sprinkler Wrench Model W2 Model J (New frame with guard installed) Model JD (Legacy frame with guard installed) Listings and Approvals cULus Listed FM Approved LPCB VdS EC WM U KCA: 0832-U KCA-CPR-S 5045 Model F1 FR56 Upright Sprinkler Components and Dimensions Load Screw Deflector Glass Bulb , (3 mm) Wrench Flat A, Co Threads ` Bulletin 074 January 2023 F1FR.HALF. UPR INT Cap/Seal Assem ,. 3 1/4" [83mm] Shown with Optional Factory Installed Water Shield ( Intermediate Upright) 2 1/4" [58mm] Page 2 of 9 www.reliablesprinkler.com Technical Specifications Style: Pendent Recessed Pendent Concealed Pendent Threads: 1/2" NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) 250 psi (17 bar) (cULus only) Material Specifications Thermal Sensor: 3 mm Glass Bulb Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table B) Sensitivity Quick response Temperature Ratingsi'i 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F(93°C) 286°F (141°C) Recessed Escutcheons Model F1 (cULus, LPCB, VdS, CE, WM) Model F2 (cULus, FM, LPCB, VdS, CE, WM) Model FP (cULus, VdS, CE, WM) Cover Plate Model CCP (cULus, VdS(2), CE(z)) Guards & Shields (New Frames)(') F-1 Guard (FM) F-5 Guard/Shield Kit (FM) F-7 Guard (cULus) F-8 Guard/Shield Kit (cULus) S-1 Shield (cULus, FM) Guards $ Shields (Legacy Frames)(') C-1 Guard (FM) C-5 Guard/Shield Kit (FM) D-1 Guard (cULus, FM) D-4 Guard/Shield Kit (FM) D-5 Guard/Shield Kit (cULus, FM) S-1 Shield (cULus, FM) Sprinkler Wrenches Model W2 (pendent) Model W4 (recessed or concealed) Model J (New frame with guard installed) Model JD (Legacy frame with guard installed) Listings and Approvals(") cULus Listed FM Approved LPCB VdS EC WM U KCA: 0832-U KCA-CPR-S5045, 0831-UKCA-CPR-5072 (CCP) Notes: 1. 286°F (141 °C) temperature rated sprinkler not listed for recessed or concealed use. 2. VdS and CE approval for CCP concealed use is for 155'C (68°C) sprinkler ONLY. 3. Not suitable for recessed or concealed pendent installations. 4. When used surface mounted or exposed. See Recessed Escutcheon and Cover Plate section for specific approvals when installed recessed or concealed. Model F1 FR56 Pendent Sprinkler Components and Dimensions Threads Wrench Flat Glass Bulb (3 mm) Deflector FIFR HALF PEND PIT Cap/Seal Assembly Load Screw Note: Please refer to Figure 8 for recessed and concealed installation. —� V [25mm] I — Shown with Optional S-1 Water Shield (Ordered Separately) ,mm] Figure 2 Bulletin 074 pet Page 3 of 9 January2023 f1 www.reliablesprinkler.com Technical Specifications Style: Horizontal Sidewall Recessed Horizontal Sidewall Threads: 1/2" NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) 250 psi (17 bar) (cULus only) Material Specifications Thermal Sensor: 3 mm Glass Bulb Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table B) Sensitivity Quick response Temperature Ratings 135-F(57°C) 155-F(68°C) 175°F (79°C) 200-F(93°C) 286-F(141°C) Recessed Escutcheons(') Model F1 (cULus) Model F2 (cULus, FM) Model FP (cULus) Guards & Shields (New Frames)(') F-4 Guard (FM) F-7 Guard (cULus) Guards & Shields (Legacy Frames)(') C1 Guard (FM) D1 Guard (cULus) Sprinkler Wrenches Model W2 (non -recessed) Model W4 (recessed) Model J (New frame with guard installed) Model JD (Legacy frame with guard installed) Listings and Approvals cULus Listed) FM Approved') Notes: 1. 286°F (141 °C) temperature rated sprinkler not listed for recessed use. 2. FM approved recessed installation when used with Model F2 escutcheon ONLY. 3. Not suitable for recessed horizontal sidewall installations. 4. cULus Listed for Light and Ordinary Hazard when installed exposed or surface mounted. Listed for Light Hazard ONLY when installed recessed. 5. FM Approved for Light Hazard ONLY. Model F1 FR56 Horizontal Sidewall Sprinkler Components and Dimensions Deflector Glass Bulb (3 mm) Wrench Flat Load Screw Note: Please refer to Figure 9 for recessed installation. Frame F1FR-HALF-HSW Cap/Seal Assembly Threads 1 1/8" [28mm] 2 3/4" [70mm] T Bulletin 074 Page 4 of 9 Reliable www January 2023 _ .reliablesprinkler.com Technical Specifications Style: Upright Vertical Sidewall Pendent Vertical Sidewall Threads: 1/2" NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm Glass Bulb Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table B) Sensitivity Quick response Temperature Ratings 135°F (57°C) 155°F (68°C) 175-F(79°C) 200°F(93°C) 286°F (141°C) Guards & Shields (New Frames) F-2 Guard (FM) Guards & Shields (Legacy Frames) C1 Guard (FM) Sprinkler Wrenches Model W2 Model J (New frame with guard installed) Model JD (Legacy frame with guard installed) Listings and Approvals0) cULus Listed FM Approved LPCB(z) UKCA:0832-UKCA-CPR-S5045 Notes: 1. Listed and approved for Light Hazard ONLY. 2. LPCB approved for use in pendent position ONLY. Model F1 FR56 Vertical Sprinkler Components and Dimensions Deflector Glass Bulb (3 mm) Wrench Flat Load Screw Frame F1FR HALF VSW Cap/Seal Assembly Threads 40- 1 1/2" [38mm] 1CO- 2 1/4" [57mm] 11 Bulletin 074 Reliably Page 5 of 9 January 2023 www.reliablesprinkler.com Recessed and Concealed Installation: Pendent Sprinklers 2-1/4" 2-1/4" �.— (57 mm) Dia. (57 mm) Dia. Hole in Ceiling Hole in Ceiling 1-15/16" 1-15/16" (49 mm) Dia. Reducing (49 mm) Dia. Reducing Fitting Fitting Face of Fitting Face of Fitting to Face of Ceiling to Face of Ceiling 1-1/8" (29 mm) at 7/8" (22 mm) at Max. Recess i Max. Recess — — 3/8" (10 mm) at 3/8'. (10 mm) at Min. Recess I _ Min. Recess 1-3/4" 1-3/4" (44 mm) 7' (44 mm) 1-1/4" (25 mm) (32 mm) 1 L Minimum Maximum Minimum Maximum Recess — 2-7/8" (72 mm) Dia. Recess Recess 2.7/B' (72 mm) Dia. Recess Models F1 & F1 FIR Pendent Sprinkler Models F1 & F1 FIR Pendent Sprinkler with Model F1 Recessed Escutcheon with Model F2 Recessed Escutcheon 3/4" (19mm) Nominal Adjustment 1/2" (13mm) Nominal Adjustment Ft REC PENC CCP 2-1/2" 2-1/2" (64 mm) Dia. - (64 mm) Dia. Hale in Ceiling Hole in Ceiling 2-5/16" 2-5/16" (59 mm) Dia. Reducing (59 mm) Dia. Reducing Fitting Filling Face of Fitting Face of Fitting Vented Cup to Face of Ceiling Vented Cup — to Face of Ceiling 1-112" (31 mm) at \ 1-1/2" (38 mm) at Max. Recess Max- Recess I 1" (25 mm) at 1" (25 mm) at I Min, Recess __ Min. Recess L (25 mm) 1/2" .L (121mm) Minimum 3-3/16" (78 mm) Dia. Recess Maximum Recess Models F1 & F1 FIR Pendent Sprinkler with Model FP Recessed Escutcheon 1/2" (13mm) Nominal Adjustment Note: Model FP recessed assemblies may not be used where the pressure in the space above the ceiling is positive with respect to the protected area. Ensure that the openings in the Model FP cup are unobstructed following installation. F1 Escutcheon (F2 Similar) _ Al (12 mm) Minimum Recess I Maximum 3-5/16- (84 mm) Dia. Recess Model F1 FR56 CCP Conical Concealed Sprinkler 1/2" (13mm) Nominal Adjustment (Nominal Cover Plate Projection is 1" (25 mm)) Note: Model CCP concealed assemblies may not be used where the pressure in the space above the ceiling is positive wilh respect to the protected area. Ensure that the openings in the Model CCP cup are unobstructed following installation. FP Escutcheon CCP Cover Plate Bulletin 074 e Page 6 of 9 January 2023 www.reliablesprinkler.com Recessed Installation: Horizontal Sidewall Sprinklers 1/2" (12 mm) Reducing +1- 3/8" (10 mm) F-1 -T Fitting Face of fitting 1-3/8" (35 mm) Maximum Recess to face of wall i 1 4"-12" Deflector mm - 305 mm) � Deflectartoceiling (5-1/4" 1-15/16" — 2-7/8" Dia. (49 mm) (73 mm) Hole Dia. Dia. 11 1 F1 Recessed escutcheon 3/4" (19 mm) Adjustment T2 1/8" (54 mm) Minimum Recess Model F1 FIR Horizontal Sidewall Sprinkler with Model F1 Recessed Escutcheon 3/4" (19mm) Nominal Adjustment NFR-REC_HSW 3/8" (16 mm) Reducing — +/- 1/4" (6 mm) Fitting \ Face of fitting 1-5/8" (42 mm) Maximum Recess to face of wall 1 4" - 12" 1 1 (102 mm - 305 mm) Deflector to ceiling 2-1/4" 1-15116" 1 2-7/8" (SDam) (49 mm) — — '� —1 (73 mm) Hole DIA. Dia 9/16" [14mm] [ 1 [ F2 Recessed escutcheon 1/2" (13 mm) Adjustment 2-1/8" (54 mm) Minimum Recess Model F1 FIR Horizontal Sidewall Sprinkler with Model F2 Recessed Escutcheon 1/2" (13mm) Nominal Adjustment 1-1/4" (32 mm) Reducing — +/- 1/4" (6 mm) 7/8" (22 mm) Maximum Recess FittingFace of fitting \ to face of wall 1 4" - 12" j I I(102 mm - 305 mm) Deflector Deflector to ceiling (6 -5/8" 2-5116" t 3-1 /4" Dia (58 — - (83 Hole. Dia.ia. Dia,a 9/16" [14mm] I Vented Cup_ 1-3/8" (35 mm) Minimum Recess Model F1 FIR Horizontal Sidewall Sprinkler with Model FP Recessed Escutcheon 1/2" (13mm) Nominal Adjustment Note: Model FP recessed assemblies may not be used where the pressure in the space behind the sprinkler is positive with respect to the space in the protected area. Ensure that the openings in the Model FP cup are unobstructed following installation. Bulletin 074 Page 7 of 9 January 2023 Reliable www reliablesprinkler.com AV U --- - _2 Model W2 (upright, pendent) Model J (New frame with guard installed) - Model JD (Legacy frame with guard installed, similar but with zinc finish) Model W4 (recessed, concealed pendent) Finishes0) FM . Standard Finishes Special Application Finishes Sprinkler I F1, F2 and FP(2) Escutcheons CCP Cover Plate(2) Sprinkler p F1, F2 and FP(2) Escutcheons CCP Cover Plate(2) Bronze Brass Chrome Electroless Nickel PTFE(3)(4) Bright Brass Bright Brass Chrome Chrome White Paint Bright Brass(5) Satin Chrome Satin Chrome White Pol ester<3> White Polyester I Satin Chrome Custom Color Polyester Custom Color Paint Custom Color Polvester(3) Notes: 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. 2 Model FP escutcheons and Model CCP sprinklers utilize a galvanized steel cup with a finished trim ring or cover plate. 3. cULus Listed as corrosion resistant. 4. FM Approved as corrosion resistant. 5. For 200°F (93°C) maximum temperature rated sprinklers only. Installation Model F1 FR Series sprinklers must be installed in accordance with NFPA13 and the requirements of all applicable authorities having jurisdiction. Model F1 FR Series sprinklers must be installed with the Reliable sprinkler installation wrench identified in this Bulletin. Any other wrench may damage the sprinkler. The Models W2 and W4 wrenches have two sets of jaws. Use the smallest set of jaws that fit on the wrench flats of the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N•m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Glass bulb sprinklers have orange bulb protectors or protective caps to minimize bulb damage during shipping, handling and installation. Reliable sprinkler installation wrenches are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprinkler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vulnerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. Maintenance Reliable Model F1 FR series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non -operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuuming without touching the sprinkler. Replace any sprinkler which has been painted (other than factory applied). A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadvertent operation or non -operation during a fire event. Bulletin 074 Reliable Page 8 of 9 January 2023 www.reliablesprinkler.com Guarantee For the guarantee, terms, and conditions, visit www. reliablesprinkler.com. Ordering Information Specify the following when ordering: Model F1FR56 Deflector/Orientation • Upright • Intermediate Upright • Pendent • CCP Concealed Pendent • Horizontal Sidewall • Vertical Sidewall Temperature Rating • See sprinkler technical specifications Sprinkler Finish • See Table B Recessed Escutcheon(')(z) • F1 • F2 • FP Escutcheon Finish • See Table B CCP Cover Plate Temperature Rating • 135°F (57°C) [For use with 135°F (57°C) and 155°F (68°C) sprinklers.] • 165°F (74°C) [For use with 175°F (79°C) and 200°F (93°C) sprinklers.] CCP Cover Plate Finish • See Table B Sprinkler Wrench • Model W2 • Model W4 (recessed, concealed) • Model J (New frame with guard installed) • Model JD (Legacy frame with guard installed) Notes: 1. 286°F (141 °C) sprinklers are not listed to be used recessed or concealed. 2. For FM, recessed sprinklers must use the Model F2 escutcheon. Bulletin 074 ;ab Page 9 of 9 January 2023 www reliablesprinkler.com co N CO 0 M M M M M G' 6F � ri i ai L • I I .i _ _ �. ri•3�r,� J 0 W YA W LL O CITY OF SPRING PARK PAGE 1 4349 Warren Avenue Spring Park, MN 55384 ❑ Handout Given Phone:952-471-9051 Fax:952-471-9160 ❑ Lead Handout Given 6N1LDDili NG PERMIT ALT iITE ADDRESS: �614- oarhwr '.,�;t 4200 PID: ) Was the home constructed before 1978? (YES ❑, continue with line 2, NO ❑ continue without completing EPA Section) ) Will the work disturb Z6 sq ft of interior painted surfaces or>20 sq ft of exterior painted surfaces? (YES r. go to line 4, NO - line 3) Are there any windows being replaced? (YES o, go to line 4, NO o continue without completing EPA Section) Has this home been Certified Lead Free? (YES o, you MUST Attach Certification Information, NO n complete line b) I EPA Contractor Certification Number. NAT - (applies to contractor only) ROPERTY OWNER: Address W State, Contact Name- _ CONTRACTOR: %% C+ A.) State Contractor License No: ( Email: N_o�r� ARCHITECT: N`j` City: State Email: TYPE OF WORK: ❑ Commercial ❑ Residential EST VALUATION OF WORK Square feet: Detailed Description of Work: Phone. j2,5I-SDz . 5:R Fax - Contact Name 1�h. "uMtaPhona: 1.ri-1/l� Contact Name a New Construction _ o Deck o Change of Use c Pool u Finish Basement i Retaining Wail td Remodel n Porch ❑Addition , Demolition u Garage-Attacheci/Detach n Plumbing -provide detail on Page 2 ❑ Accessory Structure a Mechanical -provide detail on Page 2 Fax 7 Phone: ❑ Re -Roof ❑ Re -Side ❑ Fence ❑ Shed ❑ Window/Door Replacement # being replaced . gna;vre or this application by U1e legal property owner Ora iconsad cartlraclor. as the or nvfs repraemaave. Is raqukod and authorities the Zen" Admintst2tor or dn171" and the Building OmCil designee to enter upon the property to perform needed Irtapochom Entry may be wtitlo A prior nofke. I hereby acknowledge that 1 have read this applkabon and state that ea wb mmbn Is true and w vct to the best or my knowledge. I further agree that all work performed will !Erin accordance with approved plans, spoclkahons and condflbns and to ablde by all ordhances of the Atunkpalty Id the laws or the State of Minnesota reoardng a Ut m taken pwsuanl to" parrs l agree to pay all plan renew fees even If i choose not to proceed With the work. Pertna erpiros when work riot COIrlmemed within 180 days front date of pehmlt or irwark Is %v5ponded. abandoned. or not Inspected for iao days. work beyond Ina scope of this perms. t e Work. P t a parml Or When ark u be eubtect to a penalty. on Noise Ordinance In Effect: MONDAY - FRIDAY Before 7 a.m. and after 10 P.M. WeekendslHolidays before 7 a.m. and after 8 o.m. SIGNATURE OF APPLICANT: i PRINTED NAME: P'1 S'Go OCCUP. TYPE: CONST. TYPE. CODE VALUATION S Permit Fee: $ I SS • 5 Plan Review Fee: $ t State Surcharge: $ Site Inspection Fee: $ _ S.E.C_ Fee: $ Investigation Fee / Other Fee: $ Copy Charge ($.25 per 8.5 xi page) $ License Check (Sr)) / Lead Check ($5) $ SUB -TOTAL $ Plumbing Fee (from Page 2) $ Mechanical Fee (from :age 2) $ ceclal Conditions/Required Setbacks: Building Approval By: Printed Building Ap o I B City Approval By: Paid:at—_m d Date: t Receipt No. DATE: �/2mwn This is the signature of: Owner or ❑ Owner's Representative BLDG SPRINKLED Yes / No WAC Charge: $ _ Sewer & Water Hook -Up: $ Sewer & Water Disconnect: $ Water Meter $ _ Muni SE/WA Fee: $ _ e2016 SAC Escrow. $2485 Other. $ TOTAL DUE: $ -NOTE: Commercial plans will be submitted to the Met Council Environmental Svcs .for SAC determination. Escrow payment will be required when permit ,s issued. It after Met Council review no SAC Is determined escrow will be refunded In full. DATE: ❑ License Verification ❑ Lead Verification - Checked By: DATE: as C�i By Jamie Hoffman From: payment@thepaymentgroup.com Sent: Thursday, June 25, 2026 12:21 PM To: Jamie Hoffman Cc: payment@thepaymentgroup.com Subject: DANIEL DELMONICO Permit Payment to Spring Park, MN - Permits & Licenses from TPG ATTENTION: if you need assistance with this payment, please FORWARD this email to tp,gcli-e-Ms-up-p-Qft-@—nuvei.com and include your request. Your client manager will respond. Dear Spring Park, MN - Permits & Licenses, DANIEL DELMONICO has made a web Payment through The Payment Group for: ayment Information Date Paid: Thursday, 251une 2026 12:20:50 CT Confirmation: IFKFRB Credit Card Number (last 4 1009 digits): Credit Card Type: First Name J_1►11:111 Last Name American Express DELMONICO Business Name THE FIRE GROUP INC Full Address - Permit or City, State & License Zip Number HUDSON C190 Payment Amount $259.03 DANIEL DELMONICO can be reached at: 651-302-3977 or dan.delmonico@thefiregroupinc.com if there are any questions regarding this payment. Click here to login to your The Payment Group admin account Thank you once again for choosing The Payment Group! 1 RECEIPT City of Spring Park 4349 Warren Ave, Spring Park, MN 55384 (952) 471-9051 26SP-00049 1 Fire Suppression (Commercial) Payment Amount: $259.03 SPRING PARK On Lake %innetonka Receipt Number: 570 June 26, 2026 Transaction Method Payer Cashier Reference Number Credit Card The Fire Group Inc. Jamie Hoffman IFKFRB Comments Assessed Fee Items Fee items being paid by this payment Assessed Fee Item Account Code Assessed Amount Paid Balance Due On 06/19/26 State Surcharge $2.04 $2.04 $0.00 06/19/26 Commercial Fire Plan Review $101.24 $101.24 $0.00 06/19/26 Commercial Fire Permit $155.75 $155.75 $0.00 Totals. $259.03 $259.03 Previous Payments $0.00 Remaining Balance Due $0.00 Application Info Property Address Property Owner Property Owner Address Valuation 4154 SHORELINE DR, STE CORNERSTONE INVESTORS 102 JONATHAN BLVD N #200 $4,070.00 200 ET AL / CORNERSTONE CHASKA, MN 55318 SPRING PARK, MN 55364 INVESTORS LLC / TONKA VENTURES LLC Description of Work Relocate 13 pendant sprinkler heads for the ceilings & walls Jamie Hoffman From: Andy Drilling <adrilling@moundfire.com> Sent: Sunday, May 31, 2026 9:24 AM To: Jamie Hoffman Subject: Fw: Permit application (fire sprinkler) Hi Jamie, Our fire marshal reviewed the plans and they look good. Andy Drilling Fire Chief Mound Fire Department 2415 Wilshire Blvd Mound, MN 55364 952-472-3555 Office 1 952-472-3775 Fax adrilling@moundfire.com I www.moundfire.com From: Benjamin Foster<bfoster@frontierfiremn.com> Sent: Friday, May 29, 2026 7:33 AM To:Andy Drilling<adrilling@moundfire.com> Subject: RE: Permit application (fire sprinkler) Edward Jones Spring Park sprinkler plans look good. No issue. Ben Foster,CFPS is Office: 651-489-1200 1 Cell:651-797-9448 FRONTIER IER Fax: 651-489-1210 FIRE PROTECTION,INC. Email: bfoster@frontierfiremn.com Frontier Fire Protection, Inc. 1 550 County Road D West,Suite 18 New Brighton, MN 55112 From: Ben Foster<bfoster@moundfire.com> Sent:Thursday, May 28, 2026 7:44 PM To: Benjamin Foster<bfoster@frontierfiremn.com> Subject: Fw: Permit application (fire sprinkler) Get Outlook for iOS i From:Andy Drilling<adrilling@moundfire.com> Sent:Tuesday, May 26, 2026 4:24:57 PM To: Ben Foster<bfoster@moundfire.com> Subject: Fw: Permit application (fire sprinkler) Hi Ben, Can you please take a look at these sprinkler plans for the new location of Edward Jones in Spring Park? Thank you. Andy Drilling Fire Chief Mound Fire Department 2415 Wilshire Blvd Mound, MN 55364 952-472-3555 Office 1 952-472-3775 Fax aa"eiiling@moundfire.com www.moundfire.com lip From:Jamie Hoffman <ikhoffman@ci.spring-park.mn.us> Sent:Tuesday, May 26, 2026 2:33 PM To: Marcy Miller<mamiller@safebuilt.com>; Andy Drilling<adrilling@moundfire.com> Subject: FW: Permit application (fire sprinkler) Commercial fire permit for 4154 Shoreline. Andy—copying you for awareness and to ensure compliance with fire code, etc. Let me know if you want someone else to receive these when they come in. Thanks! �r Jamie Hoffman — City Clerk City of Spring Park SPRING PARK 4349 Warren Ave Spring Park, MN 55384 952.999.7491 (Direct) 952.471.9051 (City Hall) jkhoffman(�ci.sprin�-park.mn.us www.ci.spring-park.mn.us City Hall Hours are Monday—Thursday, 7:30am—S:OOpm, Friday 7:30am - 11:30am From: Dan Delmonico<dan.delmonico@fsstechnologies.com> Sent:Tuesday, May 26, 2026 2:28 PM 2 To:Jamie Hoffman <ikhoffman@ci.spring-park.mn.us> Subject: FW: Permit application (fire sprinkler) Please let me know if you need anything else from me. Thanks much, FSS Technologies 4W) Dan DelMonico Sr. Sales 651-302.3977 dan.delmonico@fsstechnologies.com 3