Description of Work:
Relocate 13 pendant sprinkler heads for the ceilings & walls
Subdivision:
Required Setbacks:
Parcel ID: 18-117-23-44-0038
Filing:
Actual Setbacks:
Lot:
Block:
Total Sq Ft:
Contractors:
Fee Items
Amount
Primary THE FIRE GROUP, INC (651) 302-3977
State Surcharge
$ 2.04
Fire THE FIRE GROUP, INC (651) 302-3977
Commercial Fire Permit
$ 155.75
Commercial Fire Plan Review $ 101.24
Total Fees: $ 259.03
NOTICE
Signature of Applicant/Date
Building Department Signature/Date
06/26/2026
MUST BE POSTED ON JOB SITE
INSPECTION CARD
*Az� City of Spring Park
SPRING PARK
OnGa�f%innetonka 4349 Warren Ave, Spring Park, MN 55384
POST THIS CARD IN A SAFE CONSPICUOUS LOCATION. PLEASE DO NOT REMOVE THIS NOTICE UNTIL ALL REQUIRED INSPECTIONS ARE MADE AND SIGNED OFF BY THE APPROPRIATE
AUTHORITY AND THE BUILDING IS APPROVED FOR OCCUPANCY. STAMPED APPROVED PLANS MUST BE AVAILABLE ON THE JOBSITE.
Fire Suppression
PERMIT NO.: 26SP-00049 PERMIT TYPE: (Commercial) ISSUED DATE: 06/26/2026 EXPIRATION DATE: 12/23/2026
PROJECT ADDRESS: 4154 SHORELINE DR, STE 200, SPRING PARK, MN 55364
CORNERSTONE INVESTORS ET AL
OWNER: / CORNERSTONE INVESTORS LLC / OWNER PHONE:
TONKA VENTURES LLC
CONTRACTOR: THE FIRE GROUP, INC CONTRACTOR PHONE:
THE FIRE GROUP INC - Dan Del
APPLICANT: Monico APPLICANT PHONE:
DESCRIPTION OF WORK: Relocate 13 pendant sprinkler heads for the ceilings & walls
(612)723-0783
(651) 302-3977
(651) 302-3977
18-117-23-
PARCEL NO.: 44-0038
CONSTRUCTION TYPE OCCUPANT LOAD:
DATE DATE
INSPECTION INSP PASSED COMMENTS INSPECTION INSP PASSED COMMENTS
Fire Suppression Fire Suppression Final
Rough -IN
Fire Approval:
PW Approval:
To request an inspection: (952) 442-7520
Date: Engineering
Approval:
Date: Other (
Date:
Date:
Page 1 of 1
.1"
PARK
City of Spring Park
4349 Warren Ave
Spring Park, MN 55384
Phone (952) 471-9051
Fax (952) 471-9160
Project Name:
Date:
06/19/2026
Approval Status:
Approved with Comments
Jurisdiction:
City of Spring Park
Construction Type:
ID:
26SP-00049
Applicant Name:
THE FIRE GROUP INC - Dan Del
Monico
Applicant Phone:
(651) 302-3977
Applicant Email:
dan.delmonico@thefiregroupinc.com
Jobsite:
4154 SHORELINE DR, STE 200
Code:
Reviewed:
Fire Sprinkler
The plans and specifications, for the project named above, have been reviewed for substantial compliance with the
current Minnesota State Building Code. This review is limited to the submitted scope of work; is based upon the
supposition that the data on which the design is based are correct and that the necessary legal authority has been
obtained to construct the project. Although every attempt has been made to identify code issues or concerns for proper
and necessary change, the project designer(s), the building contractor(s) and the property owner(s) are ultimately
responsible for providing complete code compliance and maintaining minimum construction standards for the
safeguarding of life or limb, health, public welfare and property while constructing this project.
Approval is based on the correction of all noted deficiencies and compliance with all items listed below. Any changes from
these documents and/or additional information shall be submitted to the Department of Building Safety for code
compliance review and approval. Written response of approval must be on site prior to implementation of such changes.
The following information is related to the submitted plans/scope or as general information regarding code compliance.
Compliance with the stated requirements will be verified during the construction process.
All work shall be inspected. It is the responsibility of the contractor/installer to contact the Department of Building Safety,
when ready to schedule an inspection, at (952) 442-7520 during regular business hours.
If you have any questions or concerns regarding this plan review, please contact me via telephone at (952) 442-7520 or
email at codereview@mnspect.com.
Derrick Wyman
Plans Examiner
dwyman@safebuilt.com
4154 SHORELINE DR, STE 200 Page 1
SPRING PARK
.)n Lake :arnnelunl;,r
Plan Specific Items:
Fire Sprinkler: Approved with Comments - Derrick Wyman, dwyman@safebuilt.com
PLANS DATED: 5/26/2026
PLAN SHEETS REVIEWED: 1 of 1
SCOPE OF WORK: Relocate 13 pendant sprinkler heads for the ceilings & walls
SPRINKLER SYSTEM (Y/N & TYPE): NFPA 13
PLAN SPECIFIC ITEMS (to be completed during the construction process).
1. Sprinkler heads shall be not less than 6'-0" to each other.
City of Spring Park
4349 Warren Ave
Spring Park, MN 55384
Phone (952) 471-9051
Fax (952) 471-9160
2. A supply of at least six spare sprinklers (never fewer than six) shall be maintained on the premises so that any
sprinklers that have operated or been damaged in any way can be promptly replaced.
i. The sprinklers shall be kept in a cabinet located where the temperature to which they are subjected will not
exceed 100°F.
ii. One sprinkler wrench as specified by the sprinkler manufacturer shall be provided in the cabinet for each
type of sprinkler installed to be used for the removal and installation of sprinklers in the system.
iii. A list of sprinklers installed in the property shall be posted in the sprinkler cabinet and shall include the
following: Sprinkler identification number if equipped; or the manufacturer, model, orifice, deflector type,
thermal sensitivity, and pressure rating; General description; Quantity of each type to be contained in the
cabinet; Issue date or revision date of the list.
3. Where flexible sprinkler hose fittings are used to connect sprinklers to branch lines in suspended ceilings, a label
limiting relocation of the sprinkler shall be provided on the anchoring component. (NFPA 13-2016, Section
9.2.1.3.3.4)
GENERAL ITEMS:
1. Construction or work shall be inspected in accordance with the requirements of Minnesota Rule 1300.0210.
2. It is the responsibility of the contractor/installer to contact the Department of Building Safety, when ready to
schedule an inspection, at (952) 442-7520 between the hours of 8:00 a.m. and 4:30 p.m., Monday through Friday.
3. The approved permit and all related plans and documentation shall be on site and available to the inspector at the
time of inspection.
4. Failure to provide the required documentation to the inspector at the time of inspection may result in a cancelation
of the inspection and additional inspection fees for the additional inspection(s).
5. The field inspector may identify additional code requirements during inspections. (Example of code requirement
items that might be identified are fire sprinkler heads being obstructed by framing, beams, lighting, ceiling
configurations, plumbing pipes, and mechanical system ductwork that will require review by the fire suppression
plan reviewer. Additional work being completed that is not consistent with the project scope of work or the
approved plans.)
6. Applicable Codes: 2020 Minnesota State Building Code, 2020 Minnesota State Fire Code, NFPA 13-2016
4154 SHORELINE DR, STE 200 Page 2
A-r.
PARK
om
City of Spring Park
4349 Warren Ave
Spring Park, MN 55384
Phone (952) 471-9051
Fax (952) 471-9160
4154 SHORELINE DR, STE 200 Page 3
Bulletin 074 January 2023
Relmiabld
Features
• Standard coverage quick -response sprinklers
• Upright, pendent, horizontal sidewall, and vertical sidewall
deflectors
• Low profile, compact design
• Available in a wide variety of finishes
Product Description
Reliable Model F1 FR56 series sprinklers are quick -response
standard spray automatic fire sprinklers utilizing a sensitive 3.0
mm glass bulb thermal element.
Pendent and horizontal sidewall sprinklers may be installed
exposed or surface mounted using escutcheons such as the
Reliable Models B, C, or HB (reference Technical Bulletin 204).
When installed recessed or concealed, the Model F1 FR56 series
sprinklers are specifically listed with and may only be installed
with listed Reliable escutcheons and cover plates. Refer to the
technical information on the following pages for specific listings
for recessed and concealed installations and refer to Figures 5
and 6 for dimensional information.
When fitted with an approved water shield, these sprinklers may
considered intermediate sprinklers for use in racks, below grated
walkways, and other areas where intermediate level sprinklers are
required.
Table A provides a summary of the approvals and availability of
specific Model F1 FR series sprinkler configurations. Additional
technical information for each sprinkler model is provided on the
following pages.
F1 FR56 Series
Quick Response Sprinklers
K-factor 5.6 (80)
Model F1 FR56 Pendent Model F1 FR56 Upright
q� - 7T �ft' . FVAI
Model F1 FR56 Vertical Sidewall Model F1 FR56
Horizontal Sidewall
Note: Not all versions of the product are shown.
Note: This bulletin may contain information on New and Legacy
sprinklers that reflects a dimensional change only. Sprinkler Iden-
tification Number (SIN), application, performance, and listings/
approval are not otherwise affected. Sprinklers with New frames
will include the suffix "N" in the order.
F1 FIR Series Sprinkler Summary
Sprinkler K-Factor gpm/psl'R Max. Working Pressure Sprinkler
Model (Ipm/bar'n) Orientation Listings & Approvals psi (bar) Identification
Number (SIN)
Upright
cULus, FM, LPCB, VdS,
175 (12)
RA1425
Intermediate Upright
EC, WM, UKCA
250 (17) (cULus only)
Pendent
cULus, FM, LPCB, VdS,
175 (12)
RA1414
EC, WM, UKCA
250 (17) (cULus only)
Concealed Pendent
cULus, VdS, EC, WM,
175 (12)
RA1414
F1 FR56
5.6(80)
UKCA
250 (17) (cULus only)
Horizontal Sidewall
cULus, FM
175 (12)
250 (17) (cULus only)
RA1435
Vertical Sidewall
cULus, FM, LPCB,
175 (12)
RA1485
UKCA
www.reliablesprinkler.com
Technical Specifications
Style: Upright, Intermediate Upright
Threads: 1/2" NPT or ISO 7-R1/2
Nominal K-Factor: 5.6 (80 metric)
Max. Working Pressure:
175 psi (12 bar)
250 psi (17 bar) (cULus only)
Material Specifications
Thermal Sensor: 3 mm Glass Bulb
Sprinkler Frame: Brass Alloy
Cap: Bronze Alloy
Sealing Washer: Nickel with PTFE
Load Screw: Copper Alloy
Deflector: Brass Alloy
Sprinkler Finishes
(See Table B)
Sensitivity
Quick response
Temperature Ratings
135°F (57°C)
155-F(68-C)
175-F (79-C)
200-F(93-C)
286-F (141 °C)
Guards & Shields (New Frames)
Factory Water Shield (cULus, FM)
F-1 Guard (cULus, FM)
F-3 Guard with Shield (cULus, FM)
Guards and Shields (Legacy Frames)
Factory Water Shield
C-1 Guard (FM)
C-3 Guard with Shield (cULus, FM)
D-1 Guard (cULus)
D-3 Guard with Shield (cULus)
Sprinkler Wrench
Model W2
Model J (New frame with guard installed)
Model JD (Legacy frame with guard
installed)
Listings and Approvals
cULus Listed
FM Approved
LPCB
VdS
EC
WM
U KCA: 0832-U KCA-CPR-S 5045
Model F1 FR56 Upright Sprinkler Components and Dimensions
Load Screw
Deflector
Glass Bulb
,
(3 mm)
Wrench Flat
A, Co
Threads
`
Bulletin 074
January 2023
F1FR.HALF. UPR INT
Cap/Seal Assem
,. 3 1/4" [83mm]
Shown with Optional
Factory Installed Water Shield
( Intermediate Upright)
2 1/4" [58mm]
Page 2 of 9
www.reliablesprinkler.com
Technical Specifications
Style:
Pendent
Recessed Pendent
Concealed Pendent
Threads: 1/2" NPT or ISO 7-R1/2
Nominal K-Factor: 5.6 (80 metric)
Max. Working Pressure:
175 psi (12 bar)
250 psi (17 bar) (cULus only)
Material Specifications
Thermal Sensor: 3 mm Glass Bulb
Sprinkler Frame: Brass Alloy
Cap: Bronze Alloy
Sealing Washer: Nickel with PTFE
Load Screw: Copper Alloy
Deflector: Brass Alloy
Sprinkler Finishes
(See Table B)
Sensitivity
Quick response
Temperature Ratingsi'i
135°F (57°C)
155°F (68°C)
175°F (79°C)
200°F(93°C)
286°F (141°C)
Recessed Escutcheons
Model F1 (cULus, LPCB, VdS, CE, WM)
Model F2 (cULus, FM, LPCB, VdS, CE,
WM)
Model FP (cULus, VdS, CE, WM)
Cover Plate
Model CCP (cULus, VdS(2), CE(z))
Guards & Shields (New Frames)(')
F-1 Guard (FM)
F-5 Guard/Shield Kit (FM)
F-7 Guard (cULus)
F-8 Guard/Shield Kit (cULus)
S-1 Shield (cULus, FM)
Guards $ Shields (Legacy Frames)(')
C-1 Guard (FM)
C-5 Guard/Shield Kit (FM)
D-1 Guard (cULus, FM)
D-4 Guard/Shield Kit (FM)
D-5 Guard/Shield Kit (cULus, FM)
S-1 Shield (cULus, FM)
Sprinkler Wrenches
Model W2 (pendent)
Model W4 (recessed or concealed)
Model J (New frame with guard installed)
Model JD (Legacy frame with guard
installed)
Listings and Approvals(")
cULus Listed
FM Approved
LPCB
VdS
EC
WM
U KCA: 0832-U KCA-CPR-S5045,
0831-UKCA-CPR-5072 (CCP)
Notes:
1. 286°F (141 °C) temperature rated sprinkler not listed for recessed or concealed use.
2. VdS and CE approval for CCP concealed use is for 155'C (68°C) sprinkler ONLY.
3. Not suitable for recessed or concealed pendent installations.
4. When used surface mounted or exposed. See Recessed Escutcheon and Cover Plate section for specific approvals when installed recessed or concealed.
Model F1 FR56 Pendent Sprinkler Components and Dimensions
Threads
Wrench Flat
Glass Bulb
(3 mm)
Deflector
FIFR HALF PEND PIT
Cap/Seal
Assembly
Load Screw
Note: Please refer to Figure 8 for recessed and concealed installation.
—� V [25mm] I —
Shown with Optional S-1 Water
Shield (Ordered Separately)
,mm]
Figure 2
Bulletin 074 pet Page 3 of 9
January2023 f1 www.reliablesprinkler.com
Technical Specifications
Style:
Horizontal Sidewall
Recessed Horizontal Sidewall
Threads: 1/2" NPT or ISO 7-R1/2
Nominal K-Factor: 5.6 (80 metric)
Max. Working Pressure:
175 psi (12 bar)
250 psi (17 bar) (cULus only)
Material Specifications
Thermal Sensor: 3 mm Glass Bulb
Sprinkler Frame: Brass Alloy
Cap: Bronze Alloy
Sealing Washer: Nickel with PTFE
Load Screw: Copper Alloy
Deflector: Brass Alloy
Sprinkler Finishes
(See Table B)
Sensitivity
Quick response
Temperature Ratings
135-F(57°C)
155-F(68°C)
175°F (79°C)
200-F(93°C)
286-F(141°C)
Recessed Escutcheons(')
Model F1 (cULus)
Model F2 (cULus, FM)
Model FP (cULus)
Guards & Shields (New Frames)(')
F-4 Guard (FM)
F-7 Guard (cULus)
Guards & Shields (Legacy Frames)(')
C1 Guard (FM)
D1 Guard (cULus)
Sprinkler Wrenches
Model W2 (non -recessed)
Model W4 (recessed)
Model J (New frame with guard installed)
Model JD (Legacy frame with guard
installed)
Listings and Approvals
cULus Listed)
FM Approved')
Notes:
1. 286°F (141 °C) temperature rated sprinkler not listed for recessed use.
2. FM approved recessed installation when used with Model F2 escutcheon ONLY.
3. Not suitable for recessed horizontal sidewall installations.
4. cULus Listed for Light and Ordinary Hazard when installed exposed or surface mounted. Listed for Light Hazard ONLY when
installed recessed.
5. FM Approved for Light Hazard ONLY.
Model F1 FR56 Horizontal Sidewall Sprinkler Components and Dimensions
Deflector
Glass Bulb
(3 mm)
Wrench Flat
Load Screw
Note: Please refer to Figure 9 for recessed installation.
Frame
F1FR-HALF-HSW
Cap/Seal Assembly
Threads
1 1/8" [28mm]
2 3/4" [70mm]
T
Bulletin 074 Page 4 of 9
Reliable
www
January 2023 _ .reliablesprinkler.com
Technical Specifications
Style:
Upright Vertical Sidewall
Pendent Vertical Sidewall
Threads: 1/2" NPT or ISO 7-R1/2
Nominal K-Factor: 5.6 (80 metric)
Max. Working Pressure: 175 psi (12 bar)
Material Specifications
Thermal Sensor: 3 mm Glass Bulb
Sprinkler Frame: Brass Alloy
Cap: Bronze Alloy
Sealing Washer: Nickel with PTFE
Load Screw: Copper Alloy
Deflector: Brass Alloy
Sprinkler Finishes
(See Table B)
Sensitivity
Quick response
Temperature Ratings
135°F (57°C)
155°F (68°C)
175-F(79°C)
200°F(93°C)
286°F (141°C)
Guards & Shields (New Frames)
F-2 Guard (FM)
Guards & Shields (Legacy Frames)
C1 Guard (FM)
Sprinkler Wrenches
Model W2
Model J (New frame with guard installed)
Model JD (Legacy frame with guard
installed)
Listings and Approvals0)
cULus Listed
FM Approved
LPCB(z)
UKCA:0832-UKCA-CPR-S5045
Notes:
1. Listed and approved for Light Hazard ONLY.
2. LPCB approved for use in pendent position ONLY.
Model F1 FR56 Vertical Sprinkler Components and Dimensions
Deflector
Glass Bulb
(3 mm)
Wrench Flat
Load Screw
Frame
F1FR HALF VSW
Cap/Seal Assembly
Threads
40- 1 1/2" [38mm]
1CO-
2 1/4" [57mm]
11
Bulletin 074 Reliably Page 5 of 9
January 2023 www.reliablesprinkler.com
Recessed and Concealed Installation: Pendent Sprinklers
2-1/4" 2-1/4"
�.— (57 mm) Dia. (57 mm) Dia.
Hole in Ceiling Hole in Ceiling
1-15/16" 1-15/16"
(49 mm) Dia. Reducing (49 mm) Dia. Reducing
Fitting Fitting
Face of Fitting Face of Fitting
to Face of Ceiling to Face of Ceiling
1-1/8" (29 mm) at 7/8" (22 mm) at
Max. Recess i Max. Recess
— — 3/8" (10 mm) at 3/8'. (10 mm) at
Min. Recess I _ Min. Recess
1-3/4" 1-3/4"
(44 mm) 7' (44 mm) 1-1/4"
(25 mm) (32 mm)
1 L
Minimum Maximum Minimum Maximum
Recess — 2-7/8" (72 mm) Dia. Recess Recess 2.7/B' (72 mm) Dia. Recess
Models F1 & F1 FIR Pendent Sprinkler Models F1 & F1 FIR Pendent Sprinkler
with Model F1 Recessed Escutcheon with Model F2 Recessed Escutcheon
3/4" (19mm) Nominal Adjustment 1/2" (13mm) Nominal Adjustment
Ft REC PENC CCP
2-1/2" 2-1/2"
(64 mm) Dia. - (64 mm) Dia.
Hale in Ceiling Hole in Ceiling
2-5/16" 2-5/16"
(59 mm) Dia. Reducing (59 mm) Dia. Reducing
Fitting Filling
Face of Fitting Face of Fitting
Vented Cup to Face of Ceiling Vented Cup — to Face of Ceiling
1-112" (31 mm) at \ 1-1/2" (38 mm) at
Max. Recess Max- Recess
I 1" (25 mm) at 1" (25 mm) at
I Min, Recess __ Min. Recess
L
(25 mm) 1/2"
.L (121mm)
Minimum 3-3/16" (78 mm) Dia.
Recess Maximum
Recess
Models F1 & F1 FIR Pendent Sprinkler
with Model FP Recessed Escutcheon
1/2" (13mm) Nominal Adjustment
Note: Model FP recessed assemblies may not be used where the
pressure in the space above the ceiling is positive with respect to
the protected area. Ensure that the openings in the Model FP cup
are unobstructed following installation.
F1 Escutcheon
(F2 Similar)
_ Al
(12 mm)
Minimum
Recess I Maximum
3-5/16- (84 mm) Dia. Recess
Model F1 FR56 CCP Conical Concealed Sprinkler
1/2" (13mm) Nominal Adjustment
(Nominal Cover Plate Projection is 1" (25 mm))
Note: Model CCP concealed assemblies may not be used where
the pressure in the space above the ceiling is positive wilh
respect to the protected area. Ensure that the openings in the
Model CCP cup are unobstructed following installation.
FP Escutcheon
CCP Cover Plate
Bulletin 074 e Page 6 of 9
January 2023 www.reliablesprinkler.com
Recessed Installation: Horizontal Sidewall Sprinklers
1/2" (12 mm)
Reducing +1- 3/8" (10 mm) F-1 -T
Fitting Face of fitting 1-3/8" (35 mm) Maximum Recess
to face of wall
i
1 4"-12"
Deflector
mm - 305 mm)
� Deflectartoceiling
(5-1/4" 1-15/16" — 2-7/8"
Dia. (49 mm) (73 mm)
Hole Dia. Dia.
11 1
F1 Recessed escutcheon
3/4" (19 mm) Adjustment T2 1/8" (54 mm) Minimum Recess
Model F1 FIR Horizontal Sidewall Sprinkler
with Model F1 Recessed Escutcheon
3/4" (19mm) Nominal Adjustment NFR-REC_HSW
3/8" (16 mm)
Reducing — +/- 1/4" (6 mm)
Fitting \ Face of fitting 1-5/8" (42 mm) Maximum Recess
to face of wall
1 4" - 12" 1
1 (102 mm - 305 mm)
Deflector to ceiling
2-1/4" 1-15116" 1 2-7/8"
(SDam) (49 mm) — — '� —1 (73 mm)
Hole DIA. Dia
9/16" [14mm]
[ 1
[
F2 Recessed escutcheon
1/2" (13 mm) Adjustment 2-1/8" (54 mm) Minimum Recess
Model F1 FIR Horizontal Sidewall Sprinkler
with Model F2 Recessed Escutcheon
1/2" (13mm) Nominal Adjustment
1-1/4" (32 mm)
Reducing — +/- 1/4" (6 mm) 7/8" (22 mm) Maximum Recess
FittingFace of fitting
\ to face of wall
1
4" - 12"
j I I(102 mm - 305 mm)
Deflector
Deflector to ceiling
(6 -5/8" 2-5116" t 3-1 /4"
Dia (58 — - (83
Hole. Dia.ia. Dia,a
9/16" [14mm]
I
Vented Cup_ 1-3/8" (35 mm) Minimum Recess
Model F1 FIR Horizontal Sidewall Sprinkler
with Model FP Recessed Escutcheon
1/2" (13mm) Nominal Adjustment
Note: Model FP recessed assemblies may not be used where the
pressure in the space behind the sprinkler is positive with respect
to the space in the protected area. Ensure that the openings in
the Model FP cup are unobstructed following installation.
Bulletin 074 Page 7 of 9
January 2023 Reliable www reliablesprinkler.com
AV
U --- - _2
Model W2 (upright, pendent)
Model J (New frame with guard installed) -
Model JD (Legacy frame with guard installed, similar but with zinc finish) Model W4
(recessed, concealed pendent)
Finishes0) FM .
Standard Finishes
Special Application Finishes
Sprinkler
I F1, F2 and FP(2)
Escutcheons
CCP Cover
Plate(2)
Sprinkler
p
F1, F2 and FP(2)
Escutcheons
CCP Cover Plate(2)
Bronze
Brass
Chrome
Electroless Nickel PTFE(3)(4)
Bright Brass
Bright Brass
Chrome
Chrome
White Paint
Bright Brass(5)
Satin Chrome
Satin Chrome
White Pol ester<3>
White Polyester
I Satin Chrome
Custom Color Polyester
Custom Color Paint
Custom Color Polvester(3)
Notes:
1. Paint or any other coating applied over the factory finish will void all approvals and warranties.
2 Model FP escutcheons and Model CCP sprinklers utilize a galvanized steel cup with a finished trim ring or cover plate.
3. cULus Listed as corrosion resistant.
4. FM Approved as corrosion resistant.
5. For 200°F (93°C) maximum temperature rated sprinklers only.
Installation
Model F1 FR Series sprinklers must be installed in accordance with
NFPA13 and the requirements of all applicable authorities having
jurisdiction. Model F1 FR Series sprinklers must be installed with
the Reliable sprinkler installation wrench identified in this Bulletin.
Any other wrench may damage the sprinkler. The Models W2 and
W4 wrenches have two sets of jaws. Use the smallest set of jaws
that fit on the wrench flats of the sprinkler. A leak tight sprinkler
joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24
N•m). Do not tighten sprinklers over the maximum recommended
installation torque. Exceeding the maximum recommended
installation torque may cause leakage or impairment of the
sprinkler.
Glass bulb sprinklers have orange bulb protectors or protective
caps to minimize bulb damage during shipping, handling and
installation. Reliable sprinkler installation wrenches are designed
to install sprinklers with bulb protectors in place. Remove the bulb
protector at the time when the sprinkler system is placed in service
for fire protection. Removal of the bulb protector before this time
may leave the bulb vulnerable to damage. Remove bulb protectors
by undoing the clasp by hand. Do not use tools to remove bulb
protectors.
Maintenance
Reliable Model F1 FR series sprinklers should be inspected and
the sprinkler system maintained in accordance with NFPA 25, as
well as the requirements of any Authorities Having Jurisdiction.
Prior to installation, sprinklers should remain in the original
cartons and packaging until used. This will minimize the potential
for damage to sprinklers that could cause improper operation or
non -operation.
Do not clean sprinklers with soap and water, ammonia liquid or
any other cleaning fluids. Remove dust by gentle vacuuming
without touching the sprinkler.
Replace any sprinkler which has been painted (other than factory
applied). A stock of spare sprinklers should be maintained to
allow quick replacement of damaged or operated sprinklers.
Failure to properly maintain sprinklers may result in inadvertent
operation or non -operation during a fire event.
Bulletin 074 Reliable Page 8 of 9
January 2023 www.reliablesprinkler.com
Guarantee
For the guarantee, terms, and conditions, visit www.
reliablesprinkler.com.
Ordering Information
Specify the following when ordering:
Model
F1FR56
Deflector/Orientation
• Upright
• Intermediate Upright
• Pendent
• CCP Concealed Pendent
• Horizontal Sidewall
• Vertical Sidewall
Temperature Rating
• See sprinkler technical specifications
Sprinkler Finish
• See Table B
Recessed Escutcheon(')(z)
• F1
• F2
• FP
Escutcheon Finish
• See Table B
CCP Cover Plate Temperature Rating
• 135°F (57°C) [For use with 135°F (57°C)
and 155°F (68°C) sprinklers.]
• 165°F (74°C) [For use with 175°F (79°C)
and 200°F (93°C) sprinklers.]
CCP Cover Plate Finish
• See Table B
Sprinkler Wrench
• Model W2
• Model W4 (recessed, concealed)
• Model J (New frame with guard installed)
• Model JD (Legacy frame with guard installed)
Notes:
1. 286°F (141 °C) sprinklers are not listed to be used recessed or concealed.
2. For FM, recessed sprinklers must use the Model F2 escutcheon.
Bulletin 074 ;ab Page 9 of 9
January 2023 www reliablesprinkler.com
co
N
CO
0
M
M
M
M
M
G'
6F �
ri
i
ai L • I I .i _ _ �.
ri•3�r,�
J
0
W
YA
W
LL
O
CITY OF SPRING PARK PAGE 1
4349 Warren Avenue
Spring Park, MN 55384 ❑ Handout Given
Phone:952-471-9051 Fax:952-471-9160 ❑ Lead Handout Given
6N1LDDili NG PERMIT
ALT
iITE ADDRESS: �614- oarhwr '.,�;t 4200
PID:
) Was the home constructed before 1978? (YES ❑, continue with line 2, NO ❑ continue without completing EPA Section)
) Will the work disturb Z6 sq ft of interior painted surfaces or>20 sq ft of exterior painted surfaces? (YES r. go to line 4, NO - line 3)
Are there any windows being replaced? (YES o, go to line 4, NO o continue without completing EPA Section)
Has this home been Certified Lead Free? (YES o, you MUST Attach Certification Information, NO n complete line b)
I EPA Contractor Certification Number. NAT - (applies to contractor only)
ROPERTY OWNER: Address
W State,
Contact Name- _
CONTRACTOR: %%
C+ A.) State
Contractor License No: (
Email: N_o�r�
ARCHITECT: N`j`
City: State
Email:
TYPE OF WORK:
❑ Commercial ❑ Residential
EST VALUATION OF WORK
Square feet:
Detailed Description of Work:
Phone. j2,5I-SDz . 5:R Fax -
Contact Name 1�h. "uMtaPhona: 1.ri-1/l�
Contact Name
a New Construction
_
o Deck
o Change of Use
c Pool
u Finish Basement
i Retaining Wail
td Remodel
n Porch
❑Addition
, Demolition
u Garage-Attacheci/Detach
n Plumbing -provide detail on Page 2
❑ Accessory Structure
a Mechanical -provide detail on Page 2
Fax
7
Phone:
❑ Re -Roof
❑ Re -Side
❑ Fence
❑ Shed
❑ Window/Door Replacement
# being replaced .
gna;vre or this application by U1e legal property owner Ora iconsad cartlraclor. as the or nvfs repraemaave. Is raqukod and authorities the Zen" Admintst2tor or dn171" and the Building OmCil
designee to enter upon the property to perform needed Irtapochom Entry may be wtitlo A prior nofke. I hereby acknowledge that 1 have read this applkabon and state that ea wb mmbn Is true and
w vct to the best or my knowledge. I further agree that all work performed will !Erin accordance with approved plans, spoclkahons and condflbns and to ablde by all ordhances of the Atunkpalty
Id the laws or the State of Minnesota reoardng a Ut m taken pwsuanl to" parrs l agree to pay all plan renew fees even If i choose not to proceed With
the work. Pertna erpiros when work
riot COIrlmemed within 180 days front date of pehmlt or irwark Is %v5ponded. abandoned. or not Inspected for iao days. work beyond Ina scope of this perms. t e Work.
P t a parml Or When ark
u be eubtect to a penalty.
on
Noise Ordinance In Effect: MONDAY - FRIDAY Before 7 a.m. and after 10 P.M. WeekendslHolidays before 7 a.m. and after 8 o.m.
SIGNATURE OF APPLICANT: i
PRINTED NAME: P'1 S'Go
OCCUP. TYPE: CONST. TYPE. CODE
VALUATION S
Permit Fee: $ I SS • 5
Plan Review Fee: $ t
State Surcharge: $
Site Inspection Fee: $ _
S.E.C_ Fee: $
Investigation Fee / Other Fee: $
Copy Charge ($.25 per 8.5 xi page) $
License Check (Sr)) / Lead Check ($5) $
SUB -TOTAL $
Plumbing Fee (from Page 2) $
Mechanical Fee (from :age 2) $
ceclal Conditions/Required Setbacks:
Building Approval By:
Printed Building Ap o I B
City Approval By:
Paid:at—_m d Date: t Receipt No.
DATE: �/2mwn
This is the signature of: Owner or ❑ Owner's Representative
BLDG SPRINKLED Yes / No
WAC Charge: $ _
Sewer & Water Hook -Up: $
Sewer & Water Disconnect: $
Water Meter $ _
Muni SE/WA Fee: $ _
e2016 SAC Escrow. $2485
Other. $
TOTAL DUE: $
-NOTE: Commercial plans will be submitted to the Met Council Environmental Svcs
.for SAC determination. Escrow payment will be required when permit ,s issued. It
after Met Council review no SAC Is determined escrow will be refunded In full.
DATE:
❑ License Verification ❑ Lead Verification - Checked By:
DATE: as C�i
By
Jamie Hoffman
From: payment@thepaymentgroup.com
Sent: Thursday, June 25, 2026 12:21 PM
To: Jamie Hoffman
Cc: payment@thepaymentgroup.com
Subject: DANIEL DELMONICO Permit Payment to Spring Park, MN - Permits & Licenses from
TPG
ATTENTION: if you need assistance with this payment, please FORWARD this email to
tp,gcli-e-Ms-up-p-Qft-@—nuvei.com and include your request. Your client manager will respond.
Dear Spring Park, MN - Permits & Licenses,
DANIEL DELMONICO has made a web Payment through The Payment Group for:
ayment Information
Date Paid: Thursday, 251une 2026 12:20:50 CT
Confirmation:
IFKFRB
Credit Card Number (last 4 1009
digits):
Credit Card Type:
First Name
J_1►11:111
Last Name
American Express
DELMONICO
Business
Name
THE FIRE
GROUP INC
Full Address - Permit or
City, State & License
Zip Number
HUDSON C190
Payment
Amount
$259.03
DANIEL DELMONICO can be reached at: 651-302-3977 or dan.delmonico@thefiregroupinc.com if
there are any questions regarding this payment.
Click here to login to your The Payment Group admin account
Thank you once again for choosing The Payment Group!
1
RECEIPT
City of Spring Park
4349 Warren Ave, Spring Park, MN 55384
(952) 471-9051
26SP-00049 1 Fire Suppression (Commercial)
Payment Amount: $259.03
SPRING PARK
On Lake %innetonka
Receipt Number: 570
June 26, 2026
Transaction Method Payer Cashier Reference Number
Credit Card The Fire Group Inc. Jamie Hoffman IFKFRB
Comments
Assessed Fee Items
Fee items being paid by this payment
Assessed Fee Item Account Code Assessed Amount Paid Balance Due
On
06/19/26 State Surcharge $2.04 $2.04 $0.00
06/19/26 Commercial Fire Plan Review $101.24 $101.24 $0.00
06/19/26 Commercial Fire Permit $155.75 $155.75 $0.00
Totals. $259.03 $259.03
Previous Payments $0.00
Remaining Balance Due $0.00
Application Info
Property Address Property Owner Property Owner Address Valuation
4154 SHORELINE DR, STE CORNERSTONE INVESTORS 102 JONATHAN BLVD N #200 $4,070.00
200 ET AL / CORNERSTONE CHASKA, MN 55318
SPRING PARK, MN 55364 INVESTORS LLC / TONKA
VENTURES LLC
Description of Work
Relocate 13 pendant sprinkler heads for the ceilings & walls
Jamie Hoffman
From: Andy Drilling <adrilling@moundfire.com>
Sent: Sunday, May 31, 2026 9:24 AM
To: Jamie Hoffman
Subject: Fw: Permit application (fire sprinkler)
Hi Jamie,
Our fire marshal reviewed the plans and they look good.
Andy Drilling
Fire Chief
Mound Fire Department
2415 Wilshire Blvd Mound, MN 55364
952-472-3555 Office 1 952-472-3775 Fax
adrilling@moundfire.com I www.moundfire.com
From: Benjamin Foster<bfoster@frontierfiremn.com>
Sent: Friday, May 29, 2026 7:33 AM
To:Andy Drilling<adrilling@moundfire.com>
Subject: RE: Permit application (fire sprinkler)
Edward Jones Spring Park sprinkler plans look good. No issue.
Ben Foster,CFPS
is Office: 651-489-1200 1 Cell:651-797-9448
FRONTIER IER Fax: 651-489-1210
FIRE PROTECTION,INC. Email: bfoster@frontierfiremn.com
Frontier Fire Protection, Inc. 1 550 County Road D West,Suite 18
New Brighton, MN 55112
From: Ben Foster<bfoster@moundfire.com>
Sent:Thursday, May 28, 2026 7:44 PM
To: Benjamin Foster<bfoster@frontierfiremn.com>
Subject: Fw: Permit application (fire sprinkler)
Get Outlook for iOS
i
From:Andy Drilling<adrilling@moundfire.com>
Sent:Tuesday, May 26, 2026 4:24:57 PM
To: Ben Foster<bfoster@moundfire.com>
Subject: Fw: Permit application (fire sprinkler)
Hi Ben,
Can you please take a look at these sprinkler plans for the new location of Edward Jones in Spring Park?
Thank you.
Andy Drilling
Fire Chief
Mound Fire Department
2415 Wilshire Blvd Mound, MN 55364
952-472-3555 Office 1 952-472-3775 Fax
aa"eiiling@moundfire.com www.moundfire.com
lip
From:Jamie Hoffman <ikhoffman@ci.spring-park.mn.us>
Sent:Tuesday, May 26, 2026 2:33 PM
To: Marcy Miller<mamiller@safebuilt.com>; Andy Drilling<adrilling@moundfire.com>
Subject: FW: Permit application (fire sprinkler)
Commercial fire permit for 4154 Shoreline.
Andy—copying you for awareness and to ensure compliance with fire code, etc. Let me know if you want someone
else to receive these when they come in.
Thanks!
�r Jamie Hoffman
— City Clerk
City of Spring Park
SPRING PARK 4349 Warren Ave
Spring Park, MN 55384
952.999.7491 (Direct)
952.471.9051 (City Hall)
jkhoffman(�ci.sprin�-park.mn.us
www.ci.spring-park.mn.us
City Hall Hours are Monday—Thursday, 7:30am—S:OOpm, Friday 7:30am - 11:30am
From: Dan Delmonico<dan.delmonico@fsstechnologies.com>
Sent:Tuesday, May 26, 2026 2:28 PM
2
To:Jamie Hoffman <ikhoffman@ci.spring-park.mn.us>
Subject: FW: Permit application (fire sprinkler)
Please let me know if you need anything else from me.
Thanks much,
FSS Technologies
4W)
Dan DelMonico
Sr. Sales
651-302.3977 dan.delmonico@fsstechnologies.com
3