Permits - Permit# SP-2021-00039 - 4164 Shoreline Drive - 5/14/2021City of Spring Park Permit
1 CIIY OF
Cj"A RK
To Schedule an Inspection Call: 952-442-7520
Details
Permit Number: SP-2021-00034
Issue Date:
Zoning Type: COMMERCIAL
Use Type:
24 HOUR NOTICE REQUIRED FOR ALL INSPECTIONS ♦ MON-FRI: 8AM-4:30PM ♦ NO HOLIDAYS
Site Address: 4164 SHORELINE DRIVE, SP, MN 55384
Description:
Mechanical
Permit Granted To: Absolute Mechanical
Homeowners Name: TONKA VENTURES LLC
Phone Number:
Parcel #: 1811723430155
Fees
Permit Type: MECH - General (Comm)
Permit Exp: 11/8/2021
Valuation: $33,950.00
12358 State Surcharge 5/12/2021 1.00 5/14/2021 Paid Check: 21261 $16.98
12358 Permit Fee - PLG, MECH Comm 5/12/2021 1.00 5/14/2021 Paid Check: 21261 $625.50
12358 Plan Review Fee 5/12/2021 1.00 5/14/2021 Paid Check: 21261 $406.58
Total: $1,049.06
Notes
• This permit is issued in accordance with and subject to all provisions of Ordinances and policies governing building and zoning in City of
Spring Park.
• Permit Holder/Contractor/Owners Agent is responsible to call for the inspections!
• Permit Packet, including approved plan, and this inspection record must be posted in an accessible location before calling for inspection.
Maintain this inspection record until work is complete.
• No deviations from the approved plans are allowed without prior consent from the building inspections department.
• To Owner, Occupant, or Contractor: It is ILLEGAL TO OCCUPY this area/building until all required final inspections have been made,
approved, signed, and certificate of occupancy issued!
Scott Qualle, Building Official
City of Spring Park +4349 Warren Avenue ♦ 55384 Copyright 02021
INSPECTION RECORD
2020 MN State Building Code
City of Spring Park
SITE ADDRESS:
4164 SHORELINE DRIVE, SP, MN 55384
PERMIT TYPE:
MECH - General (Comm)
ZONE/USE TYPE:
COMMERCIAL
APPLICANT:
Absolute Mechanical
OWNER:
TONKA VENTURES LLC
Permit Number: SP-2021-00034 Issue Date:
Mechanical
Description:
No inspection will be performed, and a re -inspection fee will be charged, if this "Inspection Record", the "City of Spring Park Permit", and, when applicable, the
approved plans are not available to the inspector. This permit expires if construction activity does not commence within 180 days from obtaining this permit; when
construction activity has been suspended or abandoned for at least 180 days; or the work has not been inspected within 180 days from the last documented activity.
IF SEPARATE PERMITS ARE REQUIRED, REFER TO THE -SEPARATE PERMITS REQUIRED FOR:" STAMP ON YOUR APPROVED
PLANS/CONSTRUCTION DOCUMENTS TO IDENTIFY WHAT SEPARATE PERMITS ARE REQUIRED.
ALL REQUIRED ROUGH -IN INSPECTIONS, NOTED ON SEPARATE PERMITS, MUST BE COMPLETED PRIOR TO SCHEDULING A FRAMING
INSPECTION.
ALL REQUIRED FINAL INSPECTIONS, NOTED ON SEPARATE PERMITS, MUST BE COMPLETED PRIOR TO SCHEDULING A BUILDING FINAL
INSPECTION.
DO NOT COVER ITEMS TO BE INSPECTED.
Permit Card (8)
Inspection Inspector's Response Approval Date Comments or Corrections Required
Fire Dept Requirements Met Required
Gas Line Installation & Air Test Required
Duct Insulation Required
Balance Report(s) Required
Startup Report(s) Required
Mechanical Rough -In Required
Gas Line Air Test Required
Mechanical Final Required
MUST CALL TO SCHEDULE NO LATER THAN THE BUSINESS DAY PRIOR TO THE INSPECTION DAY: 8:00 A.M. TO 4:30 P.M. MOND" THRU
FRIDAY. PHONE NUMBER TO CALL: 952-442-7520
When a Certificate of Occupancy is needed, return this card and the approved final inspection notice to
the City of Spring Park office.
Thank you for your Payment!
Transaction ID: 12358
Transaction Number.
Transaction Type: Payment
Recipient: Contractor
Notes:
Fees
-� CI rYou
C )A
City of Spring Park
4349 Warren Avenue
SP MN,55384
Ph:952-442-7520
$1,049.06
Date: 5/14/2021
Method: Check: 21261
Address: 4164 SHORELINE DRIVE, SP, MN 55384
Reference: Permit Number: SP-2021-00034 Type: MECH - General
(Comm) for Absolute Mechanical
Plan Review Fee
Paid
1.00
$406.58
State Surcharge
Paid
1.00
$16.98
Permit Fee - PLG, MECH Comm
Paid
1.00
$625.50
$406.58
$16.98
$625.50
Total Amount: $1,049.06
Page 1 of 1 Printed on: 5/14/2021
(C,:� � 00 , L
City of Spring Park
4349 Warren Ave.
Spring Park, MN 55384
City: 952-471-9051 MNSPECT: 952-442-7520
Job Address 4164 Shoreline Drive
COMMERCIAL MECHANICAL
PERMIT APPLICATION
Permit Number: SP-�1021-0403y
Owner's Phone 952-471-9855
Owner's Name Brian Yoss Business Name Boomerang Labs
Owner's Address 4164 Shoreline Drive
City/State/Zip Spring Park MN 55384
Mechanical Contractor Absolute Mechanical LLC Phone 952-831-0001
Address
7338 Ohms Lane mkranz@absmech.c0m
State Bond No. MB004888
City/State/Zip Edina MN 55439
Gas Fitters License No. MPLS TLIC21566
CHECK TYPE OF WORK: ❑ New Construction ❑ Addition llZ Alteration ❑ Replacement
Furnace
Boiler
Air Cond
Wall Heater
3
In Floor Heat
Rooftop Unit
Air Exch
Unit Heater
Fireplace
Range Hood
Exhaust Fan
Make -Up Air
Equipment EfFiciencv
System
Tag (s)
1, 2, 3
Mfg. &
Model
No.
Bryant
Equipment
Type
RTU
Heating
Cooling
Rated
Capacity
180,000
Rated
Efficiency
82%
Minimum
__Efficiency
Rated
Capacity
12.0 EER/14.3i
Rated
Efficiency
ER
Minimum
Efficiency .
Econ. Min.
Efficiency
ultra low leak
VALUATION OF WORK $ 33,950.00 VALUATION APPROVED $ S3 , q5 0
I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and
ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume
to give authority to violate or cancel the provisions of any other state or local law regulating construction or the performance of
construction. 1 agree to pay all plan review fees even if 1 choose not to proceed with the work 1 certify all taxes and Municipal fees owed
In connection with this property are current.
Applicant's Sign
Permit Fee ........................... 625.50
Code Review ....................... 406.58
State Surcharge .................. 16.98
Other..................................
Total Permit Charge $1,049.06
4/13/2021
Date
OFFICE USE ONLY
Plans checked by:
Nicole Kastern
Date: 05/11 /2021
SPRING PARK
On Lake Minnetonka
May, 11, 2021
Permit Number !SP- 2C1Z1-bVe 2A
Project Location: 4164 Shoreline Drive
Mechanical Contractor: Absolute Mechanical, LLC
7338 Ohms Ln
Edina, MN 55439
Scope: Installation of three new Roof Top Units on an existing building.
Approval is based on the correction of all noted deficiencies and compliance with all items
listed below.
The plans and specifications, for the project named above, have been reviewed for substantial
compliance with the current Minnesota State Building Code. This review is limited to the
submitted scope of work; is based upon the supposition that the data on which the design is based
are correct; and that the necessary legal authority has been obtained to construct the project.
Although every attempt has been made to identify code issues or concerns for proper and
necessary change, the project designer(s), the building contractor(s) and the property owner(s)
are ultimately responsible for providing complete code compliance and maintaining minimum
construction standards for the safeguarding of life or limb, health, public welfare and property
while constructing this project.
The following comments are related to the approved plans and will be verified during the
construction process or is general information regarding code requirements, inspections, and/or
permits.
Items to be Addressed and/or Corrected:
1. n/a
General Information:
1. Inspections:
a. All mechanical installations must be inspected and tested in accordance with the
requirements of the Minnesota State Mechanical and Fuel Gas Code.
b. It is the responsibility of the contractor/installer to notify the inspection department
when ready to schedule an inspection. Call the building inspection department at
(952) 442-7520 between the hours of 8:00 a.m. and 4:30 p.m., Monday through
Friday.
c. The approved permit and all related plans and documentation shall be on
site and available to the inspector at the time of inspection.
d. Failure to provide the required documentation to the inspector at the time of
inspection may result in a cancelation of the inspection and additional inspections
fees for the additional inspection(s).
e. The field inspector may identify additional code compliance requirements.
Any additional identified code compliance requirements shall be completed.
Required Inspections:
Rough -in: Inspection of all materials installed prior to covering
Gas Line Installation/Air Test
Final with Manometer
Required Documentation:
• Mechanical systems shall be balanced to with 10% of the design
capacities. Provide a copy of the balance report(s) to the Building
Official for review and approval prior to the final mechanical
inspection. (MMC section 309.2)
• Provide copies of startup reports for each fuel fired appliance to the
Building Official for review and approval prior to the final mechanical
inspection.
2. Governing Codes:
• 2020 Minnesota Mechanical and Fuel Gas Code (MMC & MFGC) (MN Rule 1346)
➢ 2018 International Mechanical Code: Ch. 2-15 (IMC) as amended
➢ 2017 NFPA 96: Ch. 1-10 & 12-15 (NFPA) as amended
➢ 2018 International Fuel Gas Code: Ch. 2-8 (IFGC) as amended
• 2015 Minnesota Plumbing Code (MPC) (MN Rule 4714)
➢ 2012 Uniform Plumbing Code: Ch. 2-11, 14, 17 (UPC) as amended
• 2020 Minnesota Energy Code (MEC) (MN Rule 1322)
➢ 2018 International Energy Conservation Code: Residential provisions, Ch.
2-5 (IECC-RE) as amended
Comments:
a. Read all attached information.
b. Every person performing work for which the code is applicable shall comply with
the code requirements.
c. The person, firm, or organization securing the permit is responsible for code
compliance for the work being performed.
d. The site address shall be posted and visible from the fronting street.
4. Equipment Installation:
a. Equipment shall be installed as required by the terms of their approval, in accordance
with the conditions of the listing, the manufacturer's installation instructions and the
MN State Mechanical Code. Manufacturer's installation instructions shall be
available on the lob site at the time of inspection. (MMC section 304.1)
b. Clearance around appliances shall be sufficient to allow inspection, service, repair or
replacement. (MMC section 306.1)
c. An unobstructed passage way measuring not less than 36 inches wide and 80 inches
in height shall be provided for appliances within rooms. (MMC section 306.2)
d. Mechanical ventilation systems shall be provided with manual or automatic controls
that will operate such systems whenever the spaces are occupied. Air-conditioning
Page 2 of 5
systems that supply required ventilation air shall be provided with controls designed to
automatically maintain the required outdoor air supply rate during occupancy. (MMC
405.1)
5. Gas Piping:
a. Gas piping shall be sized in compliance with MFGC section 402.
b. Corrugated stainless steel tubing (CSST) gas piping systems shall be bonded to the
electrical service grounding electrode system with minimum 6 AWG copper wire of
equivalent. (MFGC section 310.1.1)
a. This section applies to corrugated stainless -steel tubing (CSST) that is listed
with an arc -resistant jacket or coating system in accordance with ANSI LC
1/CSA 6.26. The CSST shall be electrically continuous and bonded to an
effective ground fault current path. Where any CSST component of a piping
system does not have an arc -resistant jacket or coating system, the bonding
requirements of Section 310.2 shall apply. Arc -resistant -jacketed CSST shall
be considered to be bonded where it is connected to an appliance that is
connected to the appliance grounding conductor of the circuit that supplies that
appliance. (MFGC 310.3)
c. Fittings installed in concealed locations shall be limited to the following types: (MFGC
404.5)
a. Threaded elbows, tees and couplings.
b. Brazed fittings.
c. Welded fittings.
d. Fittings listed to ANSI LC-1/CSA 6.26 or ANSI LC-4.
d. Where gas piping will be concealed within light -frame construction assemblies, the
piping shall be protected against penetration by fasteners in accordance with Sections
404.7.1 through 404.7.3; except black steel piping and galvanized steel piping shall
not be required to be protected. (MFGC 404.7)
e. Gas piping exposed to corrosive action shall be protected in an approved manner.
(MFGC section 404.11)
f. Underground piping systems shall be installed a minimum depth of 12 inches below
grade. Individual underground lines serving outdoor appliances shall be installed a
minimum depth of 8 inches. (MFGC section 404.12)
g. Steel gas piping sizes'/z inch shall be supported at intervals not greater than 6 feet, %
inch and 1 inch shall be supported at intervals of not greater than 8 feet, and piping
sizes 1'/4 inch and larger shall be supported at intervals not greater than 10 feet. Refer
to MFGC Table 415.1 of MFGC section 415 for support information for other sizes
and/or materials.
h. Copper gas tubing sizes 'h inch shall be supported at intervals not greater than 4 feet;
% inch and 3/ inch shall be supported at intervals of not greater than 6 feet. Refer to
MFGC Table 415.1 of MFGC section 415 for support information for other sizes and/or
materials.
i. Gas piping shall be elevated no less than 3%2 inches above the ground/roof surface
and protected from physical damage. (MFGC section 404.9)
j. A minimum 3-inch sediment trap shall be installed prior to the regulator. If a tee fitting
is used, it shall provide a 90-degree change in direction of gas flow. (MFGC 408.4)
k. Each appliance shall be provided with a shutoff valve in the gas line, separate from
the appliance and no further than 6 feet from the appliance, or located within 50 feet
of the appliance when located at a manifold. (MFGC section 409.5)
Page 3 of 5
I. A readily accessible main shutoff valve with a permanently attached handle shall be
installed in the first available location before the first branch line inside the building.
(MFGC section 409.1.4)
m. Gas piping that serves equipment on the roof of a building shall have a main shutoff
valve located no closer than 10 feet from the roof edge and before the first branch line.
(MMC section 409.1.4 exception)
n. All new gas piping shall be tested and inspected in compliance with MFGC
section 406.
i. Test Pressure: 1% to operating pressure but not less than 25 psig
ii. Duration: thirty (30) minutes
iii. Gauge: 2 psig increments
iv. Test Pressure: Shall be within the middle 50 percent of the gauge
pressure range
o. A final gas piping system, appliance and equipment leakage test shall be
conducted in the presence of the inspector at the final inspection. (MFGC
section 406.6)
p. Shutoff valves installed in tubing systems shall be rigidly and securely supported
independently of the tubing. (MFGC 409.7)
6. Ducts:
a. All joints, longitudinal and transverse seams, and connections in ductwork shall be
securely fastened and sealed. (MMC section 603.9)
b. All duct work shall be hung and supported in compliance with MMC section 603.10
and SMACNA standards, and support spacing shall not exceed 12 feet. Flexible and
other factory -made ducts shall be supported in accordance with the manufacturer's
instructions. (MMC section 603.10)
c. All duct work shall be inspected prior to covering or concealing.
d. All duct insulation shall be inspected prior to covering.
7. Refrigerant Piping:
a. Any portion of a refrigeration system that is subject to physical damage shall be
protected in an approved manner. (MMC section 1101.3)
b. Refrigerant circuit access ports located outdoors shall be fitted with locking -type
tamper -resistant caps or shall be otherwise secured to prevent unauthorized access.
(MMC section 1101.10)
c. Refrigerant piping shall comply with MMC section 1107.
d. Refrigerant piping shall be of an approved material in accordance with MMC section
1107.5.
e. Refrigerant pipe joints erected on the premises shall be exposed to visual inspection
prior to being covered or enclosed. (MMC section 1107.7)
f. Piping insulation shall comply with IECC-12 Table C403.2.8. (MEC C403.2.8)
g. Piping insulation shall be protected from damage, including damage from sunlight,
moisture, equipment maintenance, and wind, and shall provide shielding from solar
radiation to deter degradation of the material. (MEC section C403.2.8.1)
8. Condensate:
a. Condensate from fuel -burning appliances shall discharge to an approved plumbing
fixture via approved corrosion -resistant piping at a minimum slope of 1% slope. (MMC
section 307.1)
b. Condensate drain systems shall be provided for appliances containing evaporators or
cooling coils. (MMC section 307.2)
Page 4of5
c. Condensate drain lines shall not be less than'/ -inch internal diameter. (MMC section
307.2.2)
9. Indoor Air Quality:
a. Every occupied space shall be ventilated by natural means in accordance with Section
402 or by mechanical ventilation in accordance with MMC Section 403. (MMC 401.2)
b. Mechanical ventilation shall be provided by a method of supply air and return or
exhaust air. The amount of supply air shall be approximately equal to the amount of
return and exhaust air. The system shall not be prohibited from producing negative or
positive pressure. The system to convey ventilation air shall be designed and installed
in accordance with MMC Chapter 6. (MMC 403.1)
If you have any questions or concerns regarding this code review please, contact me via
telephone at 952-442-7520, or e-mail at codereview@mnspect.com. Refer to the permit
number in all correspondences.
Regards,
Nicol Xasfern, R.A., NCARB
Plan Reviewer
MNSPECT, LLC
Helping You Comply With The Code
235 First St. W.
Waconia, MN 55367
O: 952-442-7520
F: 952-442-7521
www.mnsi)ect.com
Page 5 of 5
a z
o �
aCq a
N W
Ln C_
a i
I
(nrn
5
Itt 0
V) Z
Ln o __
z �a
fu oy
-m' c
W rr� w 0
O ai
U =
C Pa10 =
M E, I �0
rn
_bo
is J C'.
a3 V 2
:_
ro o
u
U ro
Q
4 c
2 o
o a
.a
a a`
Z c
ro
Z C
0
E
w
a�
E
E
0
H
co
CL
N 02 Q
c t;
E L
c t o
O a
v o 0o
M
L a V)
a)
L_
Q 41
a o w
L
4
P U C
00
c a m
ar a, t�
-0 N •a
V L -14
E 2 2
>. z 'n In. a
T H N M
Electrical
All electrical must be approved by
local Electrical Inspector.
For electrical permit inquiries please
contact the City of Spring Park
Electrical Inspector.
Dave Hucky
(952) 442-7520
or
} \� 30C 3013 `
130E FIRE TEO SlK)iNG 30£ !"`Y t 3[JD
co
QO09S TO REM+�a �\
REPLACE EXIST04G V- STa� rifiE Sz10tNG
.vl ctrc. ru.nc 4 Aranch\ ] IJQC1Ft$ TO REMJUN } i+1
244-0" ; 24'-0" 24'-0" 24'-0" 24'-0" 24`-0' 2-4'-0" 24'-00' .1
1.-
I I �O
i I 1
77
—2 X 4 F.R F R MtNG CO
W/ 5/8" GYP Bp
AT EACH SIDE TO PRODUCT PR(3�UCTf4�!
900F DECK. STORAGE f� �
I I 1 � Q
' � I
Mriji ye a
s i I icc I
CJ
� to
31R Us o be installed t (2) 2 /12 reg. 1300 cfm I -Pr v Je 3/4" gasII,�;
parallel to beam and (2) 1, /12 reg. 700 cfm con ctions to existingi
over cplumn Typ.3} on bf.
21 _F Z Z RTFY 2 W 1f
21
SiOR. COUNTER
tAYOtIT W/
REMOVE +<i LLS 1zZ ti T% SINKS BY
!.. __ --.. _ ....., �...�' ,....,e........,..,:..:..� �. _ _ OWNER -
11
,.. 4? y':vALtS!TO REttgtN.rt va
i ' r• o- PATCH' NO �tlSk � ✓t , • 1201
A
LAS : M M ,
SHOP
ROOF VENT
The field copy of these plans must be kept
on -site and made available to inspector
during all inspections.
To schedule inspections call
(952) 442-7520
Please have the permit number and street
address ready at the time of the call.
NSPECTM MANHOLE,
ram.+ P dr�r� 1
Absolute Mechanical LLC
ABSOLUTE
HANICA LLC
Contractors
Absolute Mechanical LLC - 7338 Ohms Lane, Edina MN 55439 - p 952.831.0001
JOB NAME JOB LOCATION
Boomerang - Production Area Conditioning 4164 Shoreline Drive, Spring Park MN
fV m HVAC Scope of work:
1. Provide (3) Bryant 581JE11D180 10 ton RTUs with economizers, hail guards, programmable thermostats,
c: I smoke detectors and curbs.
cD 2. Provide insulated supply drops with (4) register and return drops with grilles.
0 I Provide gas connections to existing gas pipe serving production area.
11
i)>
R211-o
Co
` oo� -
i
w-0 o-0 OO
OC)m m v
W _._� _ - - �-N •C� r - - .00
m —1
_ 30 {
((D
r I Q
1
I•
p
121 C
`< CO-,
�W
1N
f
�s
N .
�
N
r
I
�
Hareland Construction
& Engineering
507 E. River St
Monticello, MN 55362
763-295-3114
763-250-4522(m)
HCE# 2021-21
date-5/06/21
iohn.hareland@gmaii.com
contractor to install three (3) 10 ton rtu at production area
unit weight of 1249# to be placed on curb and located near,
steel column/ beam line
existing roofing is TPO,assumed loading of 65 psf .
Note:
structure is adequate to support additional loading
1
IPA A
Oc
SPA" 3u�
job name
Boomerang Production RTU's
address
4164 Shoreline Dr
city
Spring Park,.MN •
client .
Absolute Mechanical
contact
Mark Kranz
cell
952-39.3-8776
email
mkranz@absmech.com
supt
cell
-IL V
n-.f V
r
c4 H Tv-3
(51
v M9
5 PH
14
• ■