Loading...
Permits - Permit# SP-2021-00039 - 4164 Shoreline Drive - 5/14/2021City of Spring Park Permit 1 CIIY OF Cj"A RK To Schedule an Inspection Call: 952-442-7520 Details Permit Number: SP-2021-00034 Issue Date: Zoning Type: COMMERCIAL Use Type: 24 HOUR NOTICE REQUIRED FOR ALL INSPECTIONS ♦ MON-FRI: 8AM-4:30PM ♦ NO HOLIDAYS Site Address: 4164 SHORELINE DRIVE, SP, MN 55384 Description: Mechanical Permit Granted To: Absolute Mechanical Homeowners Name: TONKA VENTURES LLC Phone Number: Parcel #: 1811723430155 Fees Permit Type: MECH - General (Comm) Permit Exp: 11/8/2021 Valuation: $33,950.00 12358 State Surcharge 5/12/2021 1.00 5/14/2021 Paid Check: 21261 $16.98 12358 Permit Fee - PLG, MECH Comm 5/12/2021 1.00 5/14/2021 Paid Check: 21261 $625.50 12358 Plan Review Fee 5/12/2021 1.00 5/14/2021 Paid Check: 21261 $406.58 Total: $1,049.06 Notes • This permit is issued in accordance with and subject to all provisions of Ordinances and policies governing building and zoning in City of Spring Park. • Permit Holder/Contractor/Owners Agent is responsible to call for the inspections! • Permit Packet, including approved plan, and this inspection record must be posted in an accessible location before calling for inspection. Maintain this inspection record until work is complete. • No deviations from the approved plans are allowed without prior consent from the building inspections department. • To Owner, Occupant, or Contractor: It is ILLEGAL TO OCCUPY this area/building until all required final inspections have been made, approved, signed, and certificate of occupancy issued! Scott Qualle, Building Official City of Spring Park +4349 Warren Avenue ♦ 55384 Copyright 02021 INSPECTION RECORD 2020 MN State Building Code City of Spring Park SITE ADDRESS: 4164 SHORELINE DRIVE, SP, MN 55384 PERMIT TYPE: MECH - General (Comm) ZONE/USE TYPE: COMMERCIAL APPLICANT: Absolute Mechanical OWNER: TONKA VENTURES LLC Permit Number: SP-2021-00034 Issue Date: Mechanical Description: No inspection will be performed, and a re -inspection fee will be charged, if this "Inspection Record", the "City of Spring Park Permit", and, when applicable, the approved plans are not available to the inspector. This permit expires if construction activity does not commence within 180 days from obtaining this permit; when construction activity has been suspended or abandoned for at least 180 days; or the work has not been inspected within 180 days from the last documented activity. IF SEPARATE PERMITS ARE REQUIRED, REFER TO THE -SEPARATE PERMITS REQUIRED FOR:" STAMP ON YOUR APPROVED PLANS/CONSTRUCTION DOCUMENTS TO IDENTIFY WHAT SEPARATE PERMITS ARE REQUIRED. ALL REQUIRED ROUGH -IN INSPECTIONS, NOTED ON SEPARATE PERMITS, MUST BE COMPLETED PRIOR TO SCHEDULING A FRAMING INSPECTION. ALL REQUIRED FINAL INSPECTIONS, NOTED ON SEPARATE PERMITS, MUST BE COMPLETED PRIOR TO SCHEDULING A BUILDING FINAL INSPECTION. DO NOT COVER ITEMS TO BE INSPECTED. Permit Card (8) Inspection Inspector's Response Approval Date Comments or Corrections Required Fire Dept Requirements Met Required Gas Line Installation & Air Test Required Duct Insulation Required Balance Report(s) Required Startup Report(s) Required Mechanical Rough -In Required Gas Line Air Test Required Mechanical Final Required MUST CALL TO SCHEDULE NO LATER THAN THE BUSINESS DAY PRIOR TO THE INSPECTION DAY: 8:00 A.M. TO 4:30 P.M. MOND" THRU FRIDAY. PHONE NUMBER TO CALL: 952-442-7520 When a Certificate of Occupancy is needed, return this card and the approved final inspection notice to the City of Spring Park office. Thank you for your Payment! Transaction ID: 12358 Transaction Number. Transaction Type: Payment Recipient: Contractor Notes: Fees -� CI rYou C )A City of Spring Park 4349 Warren Avenue SP MN,55384 Ph:952-442-7520 $1,049.06 Date: 5/14/2021 Method: Check: 21261 Address: 4164 SHORELINE DRIVE, SP, MN 55384 Reference: Permit Number: SP-2021-00034 Type: MECH - General (Comm) for Absolute Mechanical Plan Review Fee Paid 1.00 $406.58 State Surcharge Paid 1.00 $16.98 Permit Fee - PLG, MECH Comm Paid 1.00 $625.50 $406.58 $16.98 $625.50 Total Amount: $1,049.06 Page 1 of 1 Printed on: 5/14/2021 (C,:� � 00 , L City of Spring Park 4349 Warren Ave. Spring Park, MN 55384 City: 952-471-9051 MNSPECT: 952-442-7520 Job Address 4164 Shoreline Drive COMMERCIAL MECHANICAL PERMIT APPLICATION Permit Number: SP-�1021-0403y Owner's Phone 952-471-9855 Owner's Name Brian Yoss Business Name Boomerang Labs Owner's Address 4164 Shoreline Drive City/State/Zip Spring Park MN 55384 Mechanical Contractor Absolute Mechanical LLC Phone 952-831-0001 Address 7338 Ohms Lane mkranz@absmech.c0m State Bond No. MB004888 City/State/Zip Edina MN 55439 Gas Fitters License No. MPLS TLIC21566 CHECK TYPE OF WORK: ❑ New Construction ❑ Addition llZ Alteration ❑ Replacement Furnace Boiler Air Cond Wall Heater 3 In Floor Heat Rooftop Unit Air Exch Unit Heater Fireplace Range Hood Exhaust Fan Make -Up Air Equipment EfFiciencv System Tag (s) 1, 2, 3 Mfg. & Model No. Bryant Equipment Type RTU Heating Cooling Rated Capacity 180,000 Rated Efficiency 82% Minimum __Efficiency Rated Capacity 12.0 EER/14.3i Rated Efficiency ER Minimum Efficiency . Econ. Min. Efficiency ultra low leak VALUATION OF WORK $ 33,950.00 VALUATION APPROVED $ S3 , q5 0 I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other state or local law regulating construction or the performance of construction. 1 agree to pay all plan review fees even if 1 choose not to proceed with the work 1 certify all taxes and Municipal fees owed In connection with this property are current. Applicant's Sign Permit Fee ........................... 625.50 Code Review ....................... 406.58 State Surcharge .................. 16.98 Other.................................. Total Permit Charge $1,049.06 4/13/2021 Date OFFICE USE ONLY Plans checked by: Nicole Kastern Date: 05/11 /2021 SPRING PARK On Lake Minnetonka May, 11, 2021 Permit Number !SP- 2C1Z1-bVe 2A Project Location: 4164 Shoreline Drive Mechanical Contractor: Absolute Mechanical, LLC 7338 Ohms Ln Edina, MN 55439 Scope: Installation of three new Roof Top Units on an existing building. Approval is based on the correction of all noted deficiencies and compliance with all items listed below. The plans and specifications, for the project named above, have been reviewed for substantial compliance with the current Minnesota State Building Code. This review is limited to the submitted scope of work; is based upon the supposition that the data on which the design is based are correct; and that the necessary legal authority has been obtained to construct the project. Although every attempt has been made to identify code issues or concerns for proper and necessary change, the project designer(s), the building contractor(s) and the property owner(s) are ultimately responsible for providing complete code compliance and maintaining minimum construction standards for the safeguarding of life or limb, health, public welfare and property while constructing this project. The following comments are related to the approved plans and will be verified during the construction process or is general information regarding code requirements, inspections, and/or permits. Items to be Addressed and/or Corrected: 1. n/a General Information: 1. Inspections: a. All mechanical installations must be inspected and tested in accordance with the requirements of the Minnesota State Mechanical and Fuel Gas Code. b. It is the responsibility of the contractor/installer to notify the inspection department when ready to schedule an inspection. Call the building inspection department at (952) 442-7520 between the hours of 8:00 a.m. and 4:30 p.m., Monday through Friday. c. The approved permit and all related plans and documentation shall be on site and available to the inspector at the time of inspection. d. Failure to provide the required documentation to the inspector at the time of inspection may result in a cancelation of the inspection and additional inspections fees for the additional inspection(s). e. The field inspector may identify additional code compliance requirements. Any additional identified code compliance requirements shall be completed. Required Inspections: Rough -in: Inspection of all materials installed prior to covering Gas Line Installation/Air Test Final with Manometer Required Documentation: • Mechanical systems shall be balanced to with 10% of the design capacities. Provide a copy of the balance report(s) to the Building Official for review and approval prior to the final mechanical inspection. (MMC section 309.2) • Provide copies of startup reports for each fuel fired appliance to the Building Official for review and approval prior to the final mechanical inspection. 2. Governing Codes: • 2020 Minnesota Mechanical and Fuel Gas Code (MMC & MFGC) (MN Rule 1346) ➢ 2018 International Mechanical Code: Ch. 2-15 (IMC) as amended ➢ 2017 NFPA 96: Ch. 1-10 & 12-15 (NFPA) as amended ➢ 2018 International Fuel Gas Code: Ch. 2-8 (IFGC) as amended • 2015 Minnesota Plumbing Code (MPC) (MN Rule 4714) ➢ 2012 Uniform Plumbing Code: Ch. 2-11, 14, 17 (UPC) as amended • 2020 Minnesota Energy Code (MEC) (MN Rule 1322) ➢ 2018 International Energy Conservation Code: Residential provisions, Ch. 2-5 (IECC-RE) as amended Comments: a. Read all attached information. b. Every person performing work for which the code is applicable shall comply with the code requirements. c. The person, firm, or organization securing the permit is responsible for code compliance for the work being performed. d. The site address shall be posted and visible from the fronting street. 4. Equipment Installation: a. Equipment shall be installed as required by the terms of their approval, in accordance with the conditions of the listing, the manufacturer's installation instructions and the MN State Mechanical Code. Manufacturer's installation instructions shall be available on the lob site at the time of inspection. (MMC section 304.1) b. Clearance around appliances shall be sufficient to allow inspection, service, repair or replacement. (MMC section 306.1) c. An unobstructed passage way measuring not less than 36 inches wide and 80 inches in height shall be provided for appliances within rooms. (MMC section 306.2) d. Mechanical ventilation systems shall be provided with manual or automatic controls that will operate such systems whenever the spaces are occupied. Air-conditioning Page 2 of 5 systems that supply required ventilation air shall be provided with controls designed to automatically maintain the required outdoor air supply rate during occupancy. (MMC 405.1) 5. Gas Piping: a. Gas piping shall be sized in compliance with MFGC section 402. b. Corrugated stainless steel tubing (CSST) gas piping systems shall be bonded to the electrical service grounding electrode system with minimum 6 AWG copper wire of equivalent. (MFGC section 310.1.1) a. This section applies to corrugated stainless -steel tubing (CSST) that is listed with an arc -resistant jacket or coating system in accordance with ANSI LC 1/CSA 6.26. The CSST shall be electrically continuous and bonded to an effective ground fault current path. Where any CSST component of a piping system does not have an arc -resistant jacket or coating system, the bonding requirements of Section 310.2 shall apply. Arc -resistant -jacketed CSST shall be considered to be bonded where it is connected to an appliance that is connected to the appliance grounding conductor of the circuit that supplies that appliance. (MFGC 310.3) c. Fittings installed in concealed locations shall be limited to the following types: (MFGC 404.5) a. Threaded elbows, tees and couplings. b. Brazed fittings. c. Welded fittings. d. Fittings listed to ANSI LC-1/CSA 6.26 or ANSI LC-4. d. Where gas piping will be concealed within light -frame construction assemblies, the piping shall be protected against penetration by fasteners in accordance with Sections 404.7.1 through 404.7.3; except black steel piping and galvanized steel piping shall not be required to be protected. (MFGC 404.7) e. Gas piping exposed to corrosive action shall be protected in an approved manner. (MFGC section 404.11) f. Underground piping systems shall be installed a minimum depth of 12 inches below grade. Individual underground lines serving outdoor appliances shall be installed a minimum depth of 8 inches. (MFGC section 404.12) g. Steel gas piping sizes'/z inch shall be supported at intervals not greater than 6 feet, % inch and 1 inch shall be supported at intervals of not greater than 8 feet, and piping sizes 1'/4 inch and larger shall be supported at intervals not greater than 10 feet. Refer to MFGC Table 415.1 of MFGC section 415 for support information for other sizes and/or materials. h. Copper gas tubing sizes 'h inch shall be supported at intervals not greater than 4 feet; % inch and 3/ inch shall be supported at intervals of not greater than 6 feet. Refer to MFGC Table 415.1 of MFGC section 415 for support information for other sizes and/or materials. i. Gas piping shall be elevated no less than 3%2 inches above the ground/roof surface and protected from physical damage. (MFGC section 404.9) j. A minimum 3-inch sediment trap shall be installed prior to the regulator. If a tee fitting is used, it shall provide a 90-degree change in direction of gas flow. (MFGC 408.4) k. Each appliance shall be provided with a shutoff valve in the gas line, separate from the appliance and no further than 6 feet from the appliance, or located within 50 feet of the appliance when located at a manifold. (MFGC section 409.5) Page 3 of 5 I. A readily accessible main shutoff valve with a permanently attached handle shall be installed in the first available location before the first branch line inside the building. (MFGC section 409.1.4) m. Gas piping that serves equipment on the roof of a building shall have a main shutoff valve located no closer than 10 feet from the roof edge and before the first branch line. (MMC section 409.1.4 exception) n. All new gas piping shall be tested and inspected in compliance with MFGC section 406. i. Test Pressure: 1% to operating pressure but not less than 25 psig ii. Duration: thirty (30) minutes iii. Gauge: 2 psig increments iv. Test Pressure: Shall be within the middle 50 percent of the gauge pressure range o. A final gas piping system, appliance and equipment leakage test shall be conducted in the presence of the inspector at the final inspection. (MFGC section 406.6) p. Shutoff valves installed in tubing systems shall be rigidly and securely supported independently of the tubing. (MFGC 409.7) 6. Ducts: a. All joints, longitudinal and transverse seams, and connections in ductwork shall be securely fastened and sealed. (MMC section 603.9) b. All duct work shall be hung and supported in compliance with MMC section 603.10 and SMACNA standards, and support spacing shall not exceed 12 feet. Flexible and other factory -made ducts shall be supported in accordance with the manufacturer's instructions. (MMC section 603.10) c. All duct work shall be inspected prior to covering or concealing. d. All duct insulation shall be inspected prior to covering. 7. Refrigerant Piping: a. Any portion of a refrigeration system that is subject to physical damage shall be protected in an approved manner. (MMC section 1101.3) b. Refrigerant circuit access ports located outdoors shall be fitted with locking -type tamper -resistant caps or shall be otherwise secured to prevent unauthorized access. (MMC section 1101.10) c. Refrigerant piping shall comply with MMC section 1107. d. Refrigerant piping shall be of an approved material in accordance with MMC section 1107.5. e. Refrigerant pipe joints erected on the premises shall be exposed to visual inspection prior to being covered or enclosed. (MMC section 1107.7) f. Piping insulation shall comply with IECC-12 Table C403.2.8. (MEC C403.2.8) g. Piping insulation shall be protected from damage, including damage from sunlight, moisture, equipment maintenance, and wind, and shall provide shielding from solar radiation to deter degradation of the material. (MEC section C403.2.8.1) 8. Condensate: a. Condensate from fuel -burning appliances shall discharge to an approved plumbing fixture via approved corrosion -resistant piping at a minimum slope of 1% slope. (MMC section 307.1) b. Condensate drain systems shall be provided for appliances containing evaporators or cooling coils. (MMC section 307.2) Page 4of5 c. Condensate drain lines shall not be less than'/ -inch internal diameter. (MMC section 307.2.2) 9. Indoor Air Quality: a. Every occupied space shall be ventilated by natural means in accordance with Section 402 or by mechanical ventilation in accordance with MMC Section 403. (MMC 401.2) b. Mechanical ventilation shall be provided by a method of supply air and return or exhaust air. The amount of supply air shall be approximately equal to the amount of return and exhaust air. The system shall not be prohibited from producing negative or positive pressure. The system to convey ventilation air shall be designed and installed in accordance with MMC Chapter 6. (MMC 403.1) If you have any questions or concerns regarding this code review please, contact me via telephone at 952-442-7520, or e-mail at codereview@mnspect.com. Refer to the permit number in all correspondences. Regards, Nicol Xasfern, R.A., NCARB Plan Reviewer MNSPECT, LLC Helping You Comply With The Code 235 First St. W. Waconia, MN 55367 O: 952-442-7520 F: 952-442-7521 www.mnsi)ect.com Page 5 of 5 a z o � aCq a N W Ln C_ a i I (nrn 5 Itt 0 V) Z Ln o __ z �a fu oy -m' c W rr� w 0 O ai U = C Pa10 = M E, I �0 rn _bo is J C'. a3 V 2 :_ ro o u U ro Q 4 c 2 o o a .a a a` Z c ro Z C 0 E w a� E E 0 H co CL N 02 Q c t; E L c t o O a v o 0o M L a V) a) L_ Q 41 a o w L 4 P U C 00 c a m ar a, t� -0 N •a V L -14 E 2 2 >. z 'n In. a T H N M Electrical All electrical must be approved by local Electrical Inspector. For electrical permit inquiries please contact the City of Spring Park Electrical Inspector. Dave Hucky (952) 442-7520 or } \� 30C 3013 ` 130E FIRE TEO SlK)iNG 30£ !"`Y t 3[JD co QO09S TO REM+�a �\ REPLACE EXIST04G V- STa� rifiE Sz10tNG .vl ctrc. ru.nc 4 Aranch\ ] IJQC1Ft$ TO REMJUN } i+1 244-0" ; 24'-0" 24'-0" 24'-0" 24'-0" 24`-0' 2-4'-0" 24'-00' .1 1.- I I �O i I 1 77 —2 X 4 F.R F R MtNG CO W/ 5/8" GYP Bp AT EACH SIDE TO PRODUCT PR(3�UCTf4�! 900F DECK. STORAGE f� � I I 1 � Q ' � I Mriji ye a s i I icc I CJ � to 31R Us o be installed t (2) 2 /12 reg. 1300 cfm I -Pr v Je 3/4" gasII,�; parallel to beam and (2) 1, /12 reg. 700 cfm con ctions to existingi over cplumn Typ.3} on bf. 21 _F Z Z RTFY 2 W 1f 21 SiOR. COUNTER tAYOtIT W/ REMOVE +<i LLS 1zZ ti T% SINKS BY !.. __ --.. _ ....., �...�' ,....,e........,..,:..:..� �. _ _ OWNER - 11 ,.. 4? y':vALtS!TO REttgtN.rt va i ' r• o- PATCH' NO �tlSk � ✓t , • 1201 A LAS : M M , SHOP ROOF VENT The field copy of these plans must be kept on -site and made available to inspector during all inspections. To schedule inspections call (952) 442-7520 Please have the permit number and street address ready at the time of the call. NSPECTM MANHOLE, ram.+ P dr�r� 1 Absolute Mechanical LLC ABSOLUTE HANICA LLC Contractors Absolute Mechanical LLC - 7338 Ohms Lane, Edina MN 55439 - p 952.831.0001 JOB NAME JOB LOCATION Boomerang - Production Area Conditioning 4164 Shoreline Drive, Spring Park MN fV m HVAC Scope of work: 1. Provide (3) Bryant 581JE11D180 10 ton RTUs with economizers, hail guards, programmable thermostats, c: I smoke detectors and curbs. cD 2. Provide insulated supply drops with (4) register and return drops with grilles. 0 I Provide gas connections to existing gas pipe serving production area. 11 i)> R211-o Co ` oo� - i w-0 o-0 OO OC)m m v W _._� _ - - �-N •C� r - - .00 m —1 _ 30 { ((D r I Q 1 I• p 121 C `< CO-, �W 1N f �s N . � N r I � Hareland Construction & Engineering 507 E. River St Monticello, MN 55362 763-295-3114 763-250-4522(m) HCE# 2021-21 date-5/06/21 iohn.hareland@gmaii.com contractor to install three (3) 10 ton rtu at production area unit weight of 1249# to be placed on curb and located near, steel column/ beam line existing roofing is TPO,assumed loading of 65 psf . Note: structure is adequate to support additional loading 1 IPA A Oc SPA" 3u� job name Boomerang Production RTU's address 4164 Shoreline Dr city Spring Park,.MN • client . Absolute Mechanical contact Mark Kranz cell 952-39.3-8776 email mkranz@absmech.com supt cell -IL V n-.f V r c4 H Tv-3 (51 v M9 5 PH 14 • ■