Loading...
Permits - Permit# SP-2021-00040 - 4527 Shoreline Drive - 5/13/2021City of Spring Park Permit �UIYM R C?F71A R To Schedule an Inspection Call: 952-442-7520 Details Permit Number: SP-2021-00040 Issue Date: 5/13/2021 Zoning Type: COMMERCIAL Use Type: 24 HOUR NOTICE REQUIRED FOR ALL INSPECTIONS • MON-FRI: 8AM-4:30PM ♦ NO HOLIDAYS Site Address: 4499 SHORELINE DR, SP, MN 55384 Description: Replace water heater - like for like Permit Granted To: Yale Mechanical Permit Type: PLG Water Heater (Comm) Homeowner's Name: PHS/LAKE MINNETONKA LLC Permit Exp: 11/8/2021 Phone Number: Valuation: $6,000.00 Parcel #: 1811723340245 Fees Receipt # Product Date----- Quantity Date Paid Status Pmt Info Amount 12348 --Permit Fee —Sale 5/12/2021 1.00 5/13/2021 Paid Check: 105019 $173.50 12348 State Surcharge 5/12/2021 1.00 5/13/2021 Paid Check: 105019 $3.00 12348 Plan Review Fee 5/12/2021 1.00 5/13/2021 Paid Check: 105019 $112.78 Total: $289.28 Notes • This permit is issued in accordance with and subject to all provisions of Ordinances and policies governing building and zoning in City of Spring Park. • Permit Holder/Contractor/Owners Agent is responsible to call for the inspections! • Permit Packet, including approved plan, and this inspection record must be posted in an accessible location before calling for inspection. Maintain this inspection record until work is complete. • No deviations from the approved plans are allowed without prior consent from the building inspections department. • To Owner, Occupant, or Contractor: It is ILLEGAL TO OCCUPY this area/building until all required final inspections have been made, approved, signed, and certificate of occupancy issued! M Scott Qualle, Building Official City of Spring Park *4349 Warren Avenue ♦ 55384 Copyright 02021 INSPECTION RECORD City of Spring Park Permit Number: SP-2021-00040 Issue Date: 5/13/2021 SITE ADDRESS: 4499 SHORELINE DR, SP, MN SS384 Description: PERMIT TYPE: PLG Water Heater (Comm) Replace water heater - like for like ZONE/USE TYPE: COMMERCIAL APPLICANT: Yale Mechanical OWNER: PHS/LAKE MINNETONKA LLC No inspection will be performed, and a re -inspection fee will be charged, if this "Inspection Record", the "City of Spring Park Permit", and, when applicable, the approved plans are not available to the inspector. This permit expires if construction activity does not commence within 180 days from obtaining this permit; when construction activity has been suspended or abandoned for at least 180 days; or the work has not been inspected within 180 days from the last documented activity. IF SEPARATE PERMITS ARE REQUIRED, REFER TO THE "SEPARATE PERMITS REQUIRED FOR:" STAMP ON YOUR APPROVED PLANS/CONSTRUCTION DOCUMENTS TO IDENTIFY WHAT SEPARATE PERMITS ARE REQUIRED. ALL REQUIRED ROUGH -IN INSPECTIONS, NOTED ON SEPARATE PERMITS, MUST BE COMPLETED PRIOR TO SCHEDULING A FRAMING INSPECTION. ALL REQUIRED FINAL INSPECTIONS, NOTED ON SEPARATE PERMITS, MUST BE COMPLETED PRIOR TO SCHEDULING A BUILDING FINAL INSPECTION. DO NOT COVER ITEMS TO BE INSPECTED. Permit Card Inspection Inspector's Response Approval Date Comments or Corrections Required Plumbing. MUST CALL TO SCHEDULE NO LATER THAN THE BUSINESS DAY PRIOR TO THE INSPECTION DAY: 8:00 A.M. TO 4:30 P.M. MONDAY THRU FRIDAY. PHONE NUMBER TO CALL: 952-442-7520 When a Certificate of Occupancy is needed, return this card and the approved final inspection notice to the City of Spring Park office. JEB 21-0690 (::::X N_ City of Spring Park 4349 Warren Ave. Spring Park, MN 55384 City: 952-471-9051 MNSPECT: 952-442-7520 COMMERCIAL PLUMBING PERMIT AND PLAN REVIEW APPLICATION Permit Number: SP-2021-00040 Project (site) Address 4499 Shoreline Drive Owner's Phone 651-468-5645 Business Name Park Shore Apartment Owner's Name Presbyterian Homes City/State/Zip Spring Park, MN 55364 Owner's Address 4527 Shoreline Drive Plumbing Contractor/Designer Yale Mechanical Phone 952-884-,1661 Address 220 West 81st Street Bond Number: MB004822 City/State/Zip Minneapolis, MN 55420 Plumbing License Number: TYPE(S) OF WORK: ❑ New Construction ❑ Addition ❑ Remodel EIReplacement ❑ Food service/bar/lodging ❑ Hospital/Nursing Home EST VALUATION OF WORK: $ 6,000 PROJECT DESCRIPTION: Replace like for like water heater. BUILDING SERVICE INFORMATION: Sewer: ❑ New Municipal ❑ Existing Municipal ❑ New- On -Site Septic ❑ Existing On -Site Septic Water: ❑ New Municipal ❑ Existing Municipal ❑ New Private We'll ❑ Existing Private Well PLEASE INDICATE ALL FIXTURES INCLUDED IN THIS PERMIT: Water Closet (toilet) Lavatory (wash basin) Kitchen Sink & Disp. Laundry Tray 1 Water Heater Urinal Rough -in Future Fix. Misc. Fixtures Bathtub Shower Dishwasher Clothes Washer Water Softener Drinking Fountain Sump Floor Drain Floor Sink Piping/Treating Equipment Catch Basin Vacuum Breakers Lawn Sprinkler System Roof Leader -Rainwater Septic Tank & Drain Field Water Piping System Total Number Of Fixtures 1 Signature of this application by the legal property owner or a licensed contractor, as the owner's representative is required and authorizes the Municipality Zoning Administrator or designee and the Municipality Building Official or designee to enter upon the property to perform needed inspections. Entry maybe without prior notice. I hereby acknowledge that I have read this application and state that all information is true and correct to the best of my knowledge. I further agree that all work performed will be in accordance with approved plans, specifications and conditions, and to abide by all of the ordinances of the Municipality and the Laws of the State of Minnesota regarding actions taken pursuant to this permit, I agree to pay all plan review fees even if I choose not to proceed with the work. I certify that this plumbing system was designed in accordance with the Minnesota Plumbing Code (as amended) to the best of my abilities, and I agree to forward the report and plans to the installer of the system. �/ft _X John Black 04/28/21 Signature Print Signature Name Date n ADr)roved valuation: (D, I W Permit Fee ............................ 173.50 Code Review ....................... 112.78 State Surcharge .................. 3.00 License Look Up ................. Other.................................. Total Permit Charge $ 289.28 Permit issued by: Dale Engelmann (AK) Date: 5-10-2021 Page113 THIS PAGE MUST ACCOMPANY ALL COMMERCIAL PLUMBING PERMIT APPLICATIONS The following checklist has been compiled to assist in expediting the commercial plan review and permit issuance process. Please take a moment to review these submittal requirements and to verify all of the necessary documentation prior to submitting your project. PLUMBING PERMIT and PLAN REVIEW - THE FOLLOWING ITEMS ARE REQUIRED: ❑ Completed permit application including: ❑ Site Address (including Suite #) and Business Name ❑ Owner ❑ Owner Address ❑ Telephone Number ❑ Contractor Information (if applicable) ❑ Valuation of work being performed ❑ Description of work being performed ❑ Signature of applicant ❑ Date ❑ 2 sets of Signed Plumbing Plans ❑ Utility Site Plan / Floor Plan / Roof Plan ❑ Water Riser / Soil, Waste, Vent Riser Diagrams ❑ Plumbing Specifications ❑ Copy of Plumbers License/Bond ❑ Complete and provide Service Water Heating Compliance Forms for compliance with the Minnesota State Energy Code (https://www.ashrae.org/standards-research—technology/standards-forms—procedures) PLUMBING PLAN REVIEW - Please provide the following information: Choose one of the following: ❑ Building Sewer and/or Water Service Only (this fee applies when no interior plumbing is to be installed) $150 flat fee ❑ Plumbing System (Water distribution and drain/waste/vent systems within the building, and water and/or sewer service connections, if applicable). This portion of the fee is based on total number of drainage fixture units (DFU) Total DFU a. 25 or fewer DFU $ 150 b. 26 to 50 DFU $ 250 c. 51 to 150 DFU $ 350 d. 151 to 249 DFU $ 500 e. 250 or more DFU: $3 x _ DFU $ Maximum $4,000 ❑ Interceptors/Separators (grease interceptors, flammable water interceptors, etc...) x $70 = $ or ❑ None ❑ Storm Drainage System $150 minimum OR Each internal roof drain opening ($500 max.) x $50 = $ or ❑ None AND/OR Each storm water interceptor, separator, or catch basin design x $70 = $ or ❑ None ❑ Manufactured Home Park or Campground a. 25 or fewer sites $ 300 c. 51 to 125 sites $ 400 b. 26 to 50 sites $ 350 d. 125 or more sites $ 500 TOTAL PLUMBING PLAN REVIEW $ Page213 PLUMBING PLAN REVIEW REQUIREMENTS Below is a list of requirements necessary to complete a review of plumbing systems in commercial buildings. Please read the following carefully to ensure you provide all required information to minimize delays in the plan review process. 1. Utility Site Plan (if new services are to be installed): The utility plan must show the locations, sizes and slopes of all sanitary sewer, all storm sewer, and water service piping within the property lines. If wells or sewage treatment systems will be located on the property, they must be shown on the plan so that proper isolation distances can be verified. The utility plan must indicate the pipe materials to be used for each service unless otherwise listed in the specifications. The plan must include a directional reference. 2. Floor plan: The floor plan must show the locations of all plumbing fixtures. The sizes and locations of all horizontal sanitary and storm piping must be shown on the plan. 3. Water Riser Diagram: The drawing must show an isometric view of the water distribution piping from the water service entrance to the connection to all plumbing fixtures and equipment. The plumbing fixtures, equipment connected to the water distribution system, and all pipe sizes must be clearly labeled on the drawing. 4. Soil, Waste and Vent Riser Diagram: The drawing must show an isometric view of the waste and vent piping within the building. All pipe sizes and fixtures must be clearly labeled on the drawing. 5. Material Specifications: A list of fixtures, materials, and procedures must be provided which includes the following: a. A list of the fixtures and appurtenances that are connected to the potable water distribution system or that discharge to the sanitary waste system. The list must include manufacturer and model number of each plumbing fixture or appurtenance. b. The type and quality standard (e.g. ASTM, ANSI, etc.) of the pipe materials to be used in the plumbing system, including the type of joints. c. The pressure testing and disinfection procedures. 6. Roof plan: A roof plan must be provided if roof drains will be installed that are piped inside the building. If no internally piped roof drains will be installed, a roof plan is not necessary for plan review. A statement should be included that the roof is pitched and the building is served by scuppers. 7. Signature: All plumbing plans that are submitted to MNSPECT must be signed by a master plumber or a professional engineer who is registered in the State of Minnesota. Signature and license number must be on each plan sheet. Page313 SAMPLE DIAGRAMS Water Heater P6 P1 Tank Water Closet 4' P2 Lavatory P3 Urinal 2' P4 Dishwasher P8 P7 P5 Hand Sink P6 Mop Sink P7 3-Compartment Sink P8 P4 P8 Floor Drain (without P8 backwater valve) O 3• 2` 4' „Clean Out Figure 1 Floor Plan X4" 1' Water Meter V4' . P7 P6 Water Heater 3/4+, 3/4' 112 P4 Maximum Developed Length: 40 Feet Pressure Range: 46 - 60 psi Individual Branches 1/2" Unless Otherwise Noted — -- Cold Water --- --- Hot Water P 3/4` P2 • 5 2" VTR P1 P2 131 '3/4•�' P3 Figure 2 I P1 Water Riser Diagram 3" VTR i r 11 c.o.�l P2 I 1 !I Pi ! 1•1/2' Rd 131 I P3 L t 4' • •i, ram,,,- I j P7 I I I I I I I 1 P4 I I P6 P8 1 2' P5 P8 I 2 3" C.O. x 4' � Figure 3 C.O. a" P1 Waste and Vent Riser Diagram SAMPLE DIAGRAMS This Plan Must Be Maintained And Accessible On The Construction Site Read All Attached Materials! Manufacturers' Installation instructions shall be available on the job site at the time of inspection The approved plans and a copy of the plan review letter from the MN Dept. of Labor and Industry must be on site at the time of all inspections. An inspection will NOT be conducted if the required documents are not on site at the time of the. scheduled inspection. Must Post Address on Construction Site, Visible from the Road IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CALL GOPHER STATE ONE CALL 651-454-0002, OR 811 BEFORE BEGINNING EXCAVATION NO OCCUPANCY OR USE ALLOWED UNTIL FINAL INSPECTION AND APPROVAL CALL BUILDING INSPECTOR 952-442-7520 PENALTY -MAXIMUM $750.00 FINE EVERY PERSON PERFORMING WORK FOR WHICH THE CODE IS APPLICABLE, SHALL COMPLY WITH THE CODE. SUBJECT TO CODE COMPLIANCE DURING CONSTRUCTION ADVANCE REVIEWED FOR CODE COMPLIANCE Commercial Plumbing SUMP COVERS MUST BE SOLID MATERIAL AND SECURED. 4715.0340 SUBPART 4 ALL WATER SUPPLY PIPING IN EXTERIOR WALLS SHALL BE ADEQUATELY PROTECTED AGAINST FREEZING BY INSULATION, HEAT, OR BOTH ALL WATER FROM FOUNDATION DRAINS OR SUMPS MUST BE PUMPED OR DRAINED DIRECTLY TO THE EXTERIOR THROUGH RIGID PLASTIC OR STEEL PIPING. NO SUMP WATER IS ALLOWED TO BE PUMPED INTO FLOOR DRAINS, SINKS OR ANY OTHER ACCESS TO SANITARY SEWER. CONTRACTOR SHALL VERIFY SANITARY SEWER ELEVATION IN RELATION TO THE LOWEST FLOOR ELEVATION PRIOR TO CONSTRUCTION. MN Rule 4715.0200 N Plumbing shall be installed with due regard to preservation of the strength of structural members and prevention of damage to the walls and other surfaces through fixture usage. MN Rule 4715.0300 Subp. 4 All pipes passing under or through walls shall be protected from breakage. All pipes passing through or in contact with cinder, concrete, or other corrosive material shall be protected against external corrosion by protective coating, wrapping, or other means that will resist such corrosion. FOR ALL INSPECTIONS: Po- CALL 24 HOURS IN ►GIVE PERMIT NUMBER (952) 442-7520 May 10, 2021 Plans and Specifications: Park Shore Apartments 4499 Shoreline Drive Spring- Park, MN Submitter/Plumber: Yale Mechanical 220 West 81 st Street Minneapolis, MN 55420 Scope: The installation consisted of a replacement of a commercial gas water heater. Inspection: All plumbing installations must be inspected and tested in accordance with the requirements of the 2015 Minnesota State Plumbing Code. It is the responsibility of the contractor/installer to notify the inspection department when ready to schedule an inspection as required by Minnesota Rule 4714.103.5 thtu 4714.103.8. Call the building inspection department at (952) 442-7520 between the hours of 8:30 a.m. and 4:30 p.m., Monday through Friday. The plans for the project named above have been reviewed for substantial compliance with the Minnesota Plumbing Code, as amended, and does not cover the water supply or sewage system to which this plumbing system is connected. The review is limited to the submitted scope of work, and is based upon the supposition that the data on which the design is based are correct, and that necessary legal authority has been obtained to construct the project. The responsibility for the design of structural features and the efficiency of equipment must be taken by the project designer. Approval is contingent upon satisfactory disposition of any requirements included in this report. General Requirements: 1. Governing Codes: 2009 Minnesota Mechanical Code (MMC); 2009 Minnesota Fuel Code (MFGC); 2009 Minnesota Commercial Code (MCEC) 2. Appliances, equipment, and materials. shall be installed as required by the terms of their approval, in accordance with the conditions of the listing, the manufacturer's installation instructions and the governing codes. Manufacturer's installations instructions shall be available on the job site at the time of the inspectioh.(MMC section 304.1) Appliance and Equipment Placement and Access: 3. Clearances around appliances shall be sufficient to allow inspection, service, and repair or replacement. ( MMC section306.1) and ( MN Rules, part4715.2240 Appliance Venting: 4. Appliance venting shall comply with the manufacturer's installation requirements, MMC chapter 8, and MFGC chapter 5. Gas Piping 5. A final gas piping system, appliance and equipment leakage test shall be conducted in the presence of the Inspector at the final Inspection. (MFGS section 406.6) 6. Gas piping exposed to corrosive action such, such as moisture, shall be protected. (MFGC section 404.8) 7. A minimum 3 inch sediment trap shall be installed as close to the inlet of the equipment, before any regulator or automatic gas valve. (MFGC section 408.4) 8. Each appliance shall be provided with an accessible shutoff valve in the gas line within 6 feet of the appliance; upstream of the union, connecter or quick disconnect; and separate from the appliance. Plumbing 9. The water heater must be equipped with a full -way valve located on the cold water line near the equipment as per MN Rules, part 4714.606.2. 10. Equipment used for heating water or storing hot water shall be protected by an approved safety device as per MN Rules, part 4714.504.6. 11. The relief valve discharge pipe shall be full size and discharge with in 18 inches of the floor or a safe place of disposal as per MN Rules, part 4714.507.5. If you have any questions or concerns regarding this plan review, you may contact me via telephone at 952-442-7520 / 888-446-1801, or e-mail at codereview@mnspect.com. Refer to the above stated file number. Sincerely, in OA eVOQ� Dale Engelmann Code Compliance Examiner Plumbing Plans and Inspections MNSPECT cc: Municipal File Thank you for your Payment! Transaction ID: 12348 Transaction Number - Transaction Type: Payment Recipient: Contractor Notes: Fees Cl 1 Y OU 1' k R City of Spring Park 4349 Warren Avenue SP MN,55384 Ph:952-442-7520 $289.28 Date: 5/13/2021 Method: Check: 105019 Address: 4499 SHORELINE DR, SP, MN 55384 Reference: Permit Number: SP-2021-00040 Type: PLG Water Heater (Comm) for Yale Mechanical t,rouicx: —Permit Fee Paid 1.00 $173.50 $173.50 State Surcharge Paid 1.00 $3.00 $3.00 Plan Review Fee Paid 1.00 $112.78 $112.78 Total Amount: $289.28 Page 1 of 1 Printed on: 5/13/2021