Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permits - Permit# 18-54 - 2425 Black Lake Road - 1/1/2018
CITY OF SPRING PARK PAGE 1 BUILDING PERMIT 4349 Warren Avenue XHanclout GivenSpring Park, MN 55384 Phone: 952-471-9051 Fax:I 952-471-9160 Lead Handout Given SITE ADDRESS. �C��GLC�Z L.Qte, 'r)d' , PID: 1) Was the home constructed before 1978? (YESA continue with line 2, NOMcontinue without completing EPA Section) 2) Will the work disturb Z6 sq ft of interior painted surfaces or 2:20 sq ft of exterior painted surfaces? (YES)go to line 4, NO ❑ line 3) • 3) Are there any windows being replaced? (YESX go to line 4, NO a continue without completing EPA Section) 4) Has this home been Certified Lead Free? (YES ❑, you MUST Attach Certification Information, NOXcomplete line 5) 5) EPA Contractor Certification Number: NAT-WO- S _ (applies to contractor only) PROPERTY OWNER: MD.(k 's �S _ Address: City: State: Zip: Email: • Contact Name: Phone: - oo CONTRACTOR: BW i <l Address: City: State: YnA Zip: Phone �D� Fax: 3 4 Fj Contracto Icense o: C 0'Z to rj E3 Contact Name: TILY1 1\ Phone: Email: dicaw nr Q h b r. cgwn ARCHITECT: Address: City: State: Zip: Phone: Fax: • Email: Contact Name: Phone: TYPE OF WORK: ❑ New Construction a Deck ❑ Re -Roof ❑ Commercial XResidential ❑ Change of Use c Pool ❑ Re -Side EST. VALUATION OF WORK ❑ Finish Basement ❑ Retaining Wall ❑ Fence, C:6c)4no $ n WRemodel ❑ Porch ❑ Shed Square fe� 0� ❑ Addition ❑ Demolition ❑ Window/Door Replacement ❑ Garage-Attached/Detach ❑ Plumbing -provide detail on Page 2 # being replaced • Detailed Description of Work: ❑ Accessory Structure ❑ Mechanical -provide detail on Page 2 r- Misc Other Signature of this application by the legal property owner or a licensed contractor, as the owner's representative, is required and authorizes the Zoning Administrator or designee and the Building Official or designee to enter upon the property to perform needed inspections. Entry may be wit ut prior notice. I hereby acknowledge that I have read this application and state that information all is true and correct to the best of my knowledge. I further agree that all work performed will be In co ante with approved plans, specifications and conditions and to abide by all ordinances of the Municipality and the laws of the State of Minnesota regarding actions taken pursuant to this pe . I ree to pay all plan review fees even if 1 choose not to proceed with the work Permit � • expires when work is riot commenced within 180 days from date or permit, or if work a s nded, ab ndo , or rot Inspected for 180 days. Work beyond the scope of this permit, or work without a permit or inspection, will be subject to a penalty. Noise Ordinance In Effect: NI - FRID B o 7 a.m. and after 10 p.m. Weekends/Holidays before 7 a.m. and after 8 p.m. SIGNATURE OF APPL DATE: S PRINTED NAME: This is the signature of: ❑ Owner or ❑ Owner's Represe tative OCCUP. TYPE: ,QC _ CONST. TYPE: CODE;,,?dif 1 BLDG SPRINKLED Yes / VALUATION: $ &'apD ckr Permit Fee: $ `1rJ�. �S WAC Charge: $ Plan Review Fee: $ (Pig: -ID Sewer & Water Hook -Up: $ State Surcharge: $ Sewer & Water Disconnect: $ _ Site Inspection Fee: $ Water Meter: $ --` S.E.C. Fee: $ Muni SENVA Fee: Investigation Fee /Other Fee: $ SAC Escrow 2 485 > Copy Charge ($.25 per 8.5 x11 page) $ Oth : $ oLicense Check ($5) / Lead Check ($5) $ TOTAL DU $ w SUB -TOTAL $ S $�It Commercial plans will be submitted to t et Council Environmental All. Plumbing Fee (from Page 2) $ UJ U for SAC determination. Escrow payment will be requi n ermit Is iss Mechanical Fee from Page 2 $ after Met Council review no SAC Is determined, escrow will be refun ad in full. u. a Special Conditions/Required Setbacks: O Building Approval By: DATE: Punted Buildi oval ❑ License Verification ❑ Lead Verification - Checked By: City Approval By: DATE: Paid: /(,,,I();jT Date: Receipt No. ►&# 17 0a-r By: '3 Office Use Only Plan Review Comment Sheet Municipality: Spring Park Permit #: 18-54 Applicant: Mark and Jessica Chase/Builders by Design MUNICIPALITY FILE COPY File # R 18-643 NAT #: N/A Address: 2425 Black Lake Rd Project Desc: Remodel Valuation: $ 80,000 SEC required?: ❑ Is septic an issue? ❑ Owner permission needed? ❑ Date Issued: 10- $ -18 Inspector Issued: c.)M Number of Days: ANY SPECIAL INSPECTION REQUIREMENTS? ❑ (foundation survey approval, notify fire dept. staff, monitor SEC, etc.) Date & Comments 9/25/18 Application and plans received CJ a 25- lei d Phi /0-9 `Permit Issued cT 1618 V r fia4t LTAAI Municipality plans at kept at MNSPECT ❑ Iclear Form Municipal plans on CD ❑ INSPECTION RECORD �2015 Minnesota State Building Code ❑ 2006 Minnesota State Building Code PERMIT NUMBER i g-5, _4 DATE /V ,5 MUST CALL TO SCHEDULE NO LATER THAN THE BUSINESS DAY PRIOR TO THE INSPECTION DAY 8:00 A.M. to 4:30 P.M. Monday thru Friday 9 5 2- 4 4 2- 7 5 2 0 Site REQUIRED INSPECTIONS ARE CIRCLED i Address: L� LS (JICIC bale Date Inspector Description: M(Mi n : U b�� L ✓, PC*I S.E.C. (before excavating) Permission is hereby granted to: Owner: MCkfL I LMi CQ Olha.56 to install or construct the improvements applied for. This permit is granted upon the condition that the person to whom it is granted, and his agents, employees and workmen, shall conform in all respects to the Footings (before pouring) Foundation Survey Approved Fra. ' �.Lrl P Ordinances �/� MECHANICAL & PLUMBING INSPECTIONS of the Municipality of iir Date- Inspector and to the Statues of the State f Minn a in such cases made and provided; this permit may be revoked at any time upon violation of any of the provisions Plum of said Ordinances, Statues, or for any misrepresentation in the application. ,4rn This card and reviewed construction plans must be posted at the worksite urnIbiand maintained until all inspections have been approved: NINSPECTION will be performed if card and plans are not available tec - inspector. REINSPECTION FEE WILL BE CHARGED. N DEVIATIONS FROM THE APPROVED PLANS ARE ALLOWE GAS LINE WITHOUT PRIOR CONSENT FROM THE BUILDING INSPECTIONS _. �� DEPARTMENT. Do not occupy until all final inspections_ have been Mechanical F n completed. Permit expires when building and work is not commenced within Fireplace Rough -In 180 days or If building and work is suspended, abandoned or not Inspected for 180.days. GAS LINE Fireplace Final Note: Permit holder Is responsible to call for these Inspections. Electrical Fin c; File Cod SPRING PARK On Lake Minnetonka October 5, 2018 Permit Number: 18-54 Project Name: Builders By Design, Inc 21185 Viking Blvd Wyoming, MN 55092 Scope: Residential Code Review of a remodel at a new single-family home at 2425 Black Lake Rd. Inspections: All work shall be inspected. It is the responsibility of the contractor/installer to contact the Department of Building Safety, when ready to schedule an inspection, at (952) 442-7520 between the hours of 8:00 a.m. and 4:30 p.m., Monday through Friday. The plans and specifications for the project named above have been reviewed for substantial compliance with the current Minnesota State Building Code. The review is limited to the submitted scope of work and is based upon the supposition that the data on which the design is based are correct, and that the necessary legal authority has been obtained to construct the project. The responsibility for the design of structural features must be taken by the project designer. Any changes from the submitted plans and specifications shall be reviewed and approved by the Department of Building Safety. Approval is based on the correction of all noted deficiencies and compliance with all applicable items listed below. The following information is related to the submitted plans/scope as general information and/or code compliance requirements. Compliance with the stated requirements shall be verified during the construction process. Any changes to the plan and any required additional information shall be provided to this agency for code -compliance review and approval, prior to its installation. General Information: 1. Applicable Codes: a. 2015 MN Residential Code (MRC) (2012 IBC as amended) b. 2015 MN Special Provisions (MSP) c. 2015 MN Energy Code (MREC) (2012 IECC as amended) d. 2015 MN Mechanical Code (MMC) (2012 IMC as amended) e. 2015 MN Fuel Gas Code (MFGC) (2012 IFGC as amended) f. 2015 MN State Plumbing Code (MPC) (2012 UPC as amended) g. 2015 MN Electrical Code (MEC) (NFPA 70) 2. Separate permits are required for: a. Electrical b. Mechanical c. Plumbing 3. The field inspector may identify additional code compliance requirements. identified code compliance requirements shall be completed. Any additional City of Spring Park 4349 Warren Avenue, Spring Park, MN 55384 Phone: (952) 471-9051 / Fax: (952) 471-9160 / Web: www.ci.spring-park.mmus On .cake Minnetonka The below items are commonly missed items that require correction following inspections. These are provided for your benefit and may or may not apply specifically to your project. MN Residential Code: 1. Approved corrosion -resistant flashing shall be applied shingle -fashion in such a manner as to prevent entry of water into the wall cavity or penetration of water to the building structural framing components. Self -adhered membranes used as flashing shall comply with AAMA 711. The flashing shall extend to the surface of the exterior wall finish. Approved corrosion -resistant flashing shall be installed at all of the following locations: (MRC R703.8) a. Exterior window and door openings. Flashing shall be installed at the head and sides of exterior window and door openings and shall extend to the surface of the exterior wall finish or to the water -resistive barrier for subsequent drainage. Flashing at exterior window and door openings shall be installed in accordance with at least one of the following: i. the fenestration manufacturer's installation and flashing instructions. When flashing is not addressed in the fenestration manufacturer's instructions, it shall be installed in accordance with the flashing manufacturer's instructions; ii. in accordance with the flashing design or method of a registered design professional; and in accordance with other approved methods. b. At the intersection of chimneys or other masonry construction with frame or stucco walls, with. projecting lips on both sides under stucco copings. c. Under and at the ends of masonry, wood, or metal copings and sills. d. Continuously above all projecting wood trim. e. Where exterior porches, decks, or stairs attach to a wall or floor assembly of wood -frame construction. f. At wall and roof intersections. g. At built-in gutters. h. Where exterior material meets in other than a vertical line. i. Where the lower portion of a sloped roof stops within the plane of an intersecting wall cladding in such a manner as to divert water away from the assembly in compliance with Section R903.2.1. j. At the intersection of the foundation and rim joist framing when the exterior wall covering does not lap the foundation insulation. 2. Pan flashing of windows and doors. Pan flashing shall be installed in accordance with the fenestration manufacturer's installation and flashing instructions. Where flashing instructions or details are not provided, pan flashing shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water -resistive barrier for subsequent drainage. (MRC R703.8.1) a. Exceptions: i. Windows or doors installed in accordance with the manufacturer's installation instructions which include an alternate flashing method. ii. Windows or doors in detached accessory structures. City of Spring Park 4349 Warren Avenue, Spring Park, MN 55384 Phone: (952) 471-9051 / Fax: (952) 471-9160 / Web: www.ci.spring-park.mmus Sfa�E�l�C F��4f�f6 On Lake 9V innetonka iii. Skylights, bow or bay windows. iv. When a method is provided by a registered design professional. 3. In combustible construction, fire -blocking shall be provided to cut off all concealed draft openings (both vertical and horizontal) and to form an effective fire barrier between stories, and between a top story and the roof space. (MRC R302.11) 4. Smoke alarms shall be installed in the following locations: (MRC R314.3) a. In each sleeping room. b. Outside each separate sleeping area in the immediate vicinity of the bedrooms. c. On each additional story of the dwelling, including basements and habitable attics but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. 5. Carbon monoxide alarms shall be installed outside and not more than 10 feet (3048 mm) from each separate sleeping area or bedroom. Alarms shall be installed on each level containing sleeping areas or bedrooms. (MRC R315.1.1) 6. Handrails shall be provided on at least one side of each continuous run of treads or flight with four or more risers. Handrails to comply with MRC R311.7.8 for mounting height, continuity and grip -size. (MRC R311.7.8) 7. The maximum riser height shall be 7 3/4 inches. The riser shall be measured vertically between leading edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch. Risers shall be vertical or sloped from the underside of the nosing of the tread above at an angle not more than 30 degrees from the vertical. Open risers are permitted provided that the opening between treads does not permit the passage of a 4-inch-diameter sphere. (MRC R311.7.5.1) Exception: The opening between adjacent treads is not limited on stairs with a total rise of 30 inches or less. 8. The minimum tread depth shall be 10 inches. The tread depth shall be measured horizontally between the vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. (MRC R311.7.5.2) 9. There shall be a landing or floor on each side of each exterior door. The width of each landing shall not be less than the door served. Every landing shall have a minimum dimension of 36 inches measured in the direction of travel. Exterior landings shall be permitted to have a slope not to exceed 1/4 unit vertical in 12 units horizontal (2-percent). (MRC R311.3) 10. All interior and exterior stairways shall be provided with a means to illuminate the stairs, including the landings and treads. Interior stairways shall be provided with an artificial light source located in the immediate vicinity of each landing of the stairway. Exterior stairways shall be provided with an artificial light source located in the immediate vicinity of the top landing of the stairway. Exception: An artificial light source is not required at the top and bottom landing, provided an artificial light source is located directly over each stairway section. (MRC R303.7) City of Spring Park 4349 Warren Avenue, Spring Park, MN 55384 Phone: (952) 471-9051 / Fax: (952) 471-9160 / Web: www.ci.spring-park.mn.us 1_40�1 SPRING PARK On Lake 9Yinnetonka 11. Buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall be a minimum of 4 inches high with a minimum stroke width of 1/2 inch. (MRC R319.1) 12. Buildings with combustible ceiling or roof construction shall have an attic access opening to attic areas that exceed 30 square feet and have a vertical height of 30 inches or greater. The vertical height shall be measured from the top of the ceiling framing members to the underside of the roof framing members. The rough -framed opening shall not be less than 22 inches by 30 inches and shall be located in a hallway or other readily accessible location. When the access is located in a ceiling, minimum unobstructed headroom in the attic space shall be 30 inches at some point above the access measured vertically from the bottom of ceiling framing members. (MRC R807.1) MN Energy Code: 1. For air permeable insulations in vented attics, a baffle shall be installed adjacent to soffit and eave vents. Baffles shall maintain an opening equal or greater than the size of the vent. The baffle shall extend over the top of the attic insulation. The baffle shall be permitted to be any solid material. (MREC R402.2.3) 2. Access doors from conditioned spaces to unconditioned spaces (e.g., attics and crawl spaces) shall be weather-stripped and insulated to a level equivalent to the insulation on the surrounding surfaces. Access shall be provided to all equipment that prevents damaging or compressing the insulation. A wood framed or equivalent baffle or retainer is required to be provided when loose fill insulation is installed, the purpose of which is to prevent the loose fill insulation from spilling into the living space when the attic access is opened, and to provide a permanent means of maintaining the installed R-value of the loose fill insulation. (MREC R402.2.4) 3. New ducts, air handlers, and filter boxes shall be sealed. (MREC R403.2.2) 4. Building framing cavities shall not be used as ducts or plenums. (MREC R403.2.3) 5. Insulation for new hot water pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the following: a. Piping larger than 3/4 -inch nominal diameter. b. Piping from the water heater to kitchen outlets. c. Piping located outside the conditioned space. d. Piping from the water heater to a distribution manifold. e. Piping located under a floor slab. f. Buried piping. g. Supply and return piping in recirculation systems other than demand recirculation systems. h. Piping with run lengths greater than the maximum run lengths for the nominal pipe diameter given in Table R403.4.2. All remaining piping shall be insulated to at least R-3 or meet the run length requirements of Table R403.4.2. TABLE R403.4.2 MAXIMUM RUN LENGTH (feet) City of Spring Park 4349 Warren Avenue, Spring Park, MN 55384 Phone: (952) 471-9051 / Fax: (952) 471-9160 / Web: www.ci.spring-park.mn.us SPRING PARK On Lak<Minneeonke Nominal Pipe Diameter of Largest Diameter Pipe in the Run inch 3/9 1/2 3/4 > 3/4 Maximum Run Length 30 20 10 5 6. Both outdoor air and exhaust air may be connected to the forced air circulation system only if controls are installed to operate the forced air circulation system when the mechanical ventilation system is operating or other means are provided to prevent short circuiting of ventilation air in accordance with the manufacturer's recommendations. (MREC R403.5.9) 7. A minimum of 75 percent of the new lamps in permanently installed lighting fixtures shall be high - efficacy lamps or a minimum of 75 percent of the permanently installed lighting fixtures shall contain only high efficacy lamps. (MREC R404.1) Mechanical Code Items: 1. The air removed by every mechanical exhaust system shall be discharged outdoors at a point where it will not cause a nuisance and not less than the distances specified in IMC Section 501.3.1. The air shall be discharged to a location from which it cannot again be readily drawn in by a ventilating system. Air shall not be exhausted into an attic or crawl space and the exhaust system shall be equipped with a backdraft damper at the point of discharge. (MMC 501.3) 2. The termination points of exhaust outlets and ducts discharging to the outdoors shall be located with the following minimum distances: (MMC 501.3.1) a. For all environmental air exhaust: 3 feet from property lines; 3 feet from operable openings into buildings, and 10 feet from mechanical air intakes. b. Dryer exhaust ducts for clothes dryers shall terminate on the outside of the building and shall be equipped with a backdraft damper. Screens shall not be installed at the duct termination. Ducts shall not be connected or installed with sheet metal screws or other fasteners that will obstruct the exhaust flow. Clothes dryer exhaust ducts shall not be connected to a vent connector, vent or chimney. Clothes dryer exhaust ducts shall not extend into or through ducts or plenums. (MMC 504.4) c. Subslab soil exhaust system ducts shall extend through the roof and terminate at least 6 inches above the roof and at least 10 feet from any operable openings or air intake. (MMC 512.4) 3. Ducts shall be supported at intervals not to exceed 12 feet. Flexible and other factory -made ducts shall be supported in accordance with the manufacturer's instructions. (MMC 603.10) MN Fuel Gas Code: 1. Corrugated stainless steel tubing (CSST) gas piping systems shall be bonded to the electrical service grounding electrode system. The bonding jumper shall connect to a metallic pipe or fitting between the point of delivery and the first downstream CSST fitting. The bonding jumper shall be not smaller than 6 AWG copper wire or equivalent. Gas piping systems that contain one or more segments of CSST shall be bonded in accordance with this section. (MFC 310.1.1) 2. Where in contact with or passing through concrete or other abrasive material, metallic piping and fittings coated with a corrosion -resistant material, sleeve, or casing shall be used. Steel pipe exposed in exterior locations shall be galvanized or coated with approved corrosion - resistant material. (MFC 403.8) City of Spring Park 4349 Warren Avenue, Spring Park, MN 55384 Phone: (952) 471-9051 / Fax: (952) 471-9160 / Web: www.ci.spring-park.mn.us 3 XPRflH@ PARMEW On Lake Minnetonka 3. Prior to acceptance and initial operation, all piping installations shall be visually inspected and pressure tested to determine that the materials, design, fabrication and installation practices comply with the requirements of this code. (MFC 406.1) d. Test Pressure. Test pressure shall be measured with a manometer or with a pressure - measuring device designed and calibrated to read, record or indicate a pressure loss caused by leakage during the pressure test period. The source of pressure shall be isolated before the pressure tests are made. Mechanical gauges used to measure test pressures shall have a range such that the highest end of the scale is not greater than five times the test pressure. e. Test pressure. The test pressure to be used shall be no less than one and one-half times the proposed maximum working pressure, but not less than 25 psig irrespective of design pressure. f. Test Duration. Test duration shall be not less than one-half hour. When testing a system in a single-family dwelling, the test duration shall be permitted to be reduced to 10 minutes with prior approval from the building official. g. Test gauges. Tests which utilize dial gauges shall be performed with gauges of 2 psi incrementation or less and shall have a pressure range not greater than twice the test pressure applied. The test pressure shall be within the middle 50 percent of the test gauge pressure range. 4. Piping shall be supported at intervals not exceeding the spacing specified in Table 415.1. Spacing of supports for CSST shall be in accordance with the CSST manufacturer's instructions. TABLE 415.1 SUPPORT OF PIPING STEEL PIPE, NOMINAL SIZE OF NOMINAL SIZESPACING OF TUBING SPACING OF OF PIPE SUPPORTS (SMOOTH -WALL) SUPPORTS inches feet inch O.D. feet 112 6 1 /z 4 3/4 or 1 8 5/8 or 3/4 6 11/4 or larger 10 7/8 or 1 8 horizontal (horizontal) 11/4 or larger Every floor 1 or larger Every floor vertical level vertical level A Plumbing Items: 1. New water closets shall have an average consumption not to exceed 1.6 gallons of water per flush. (MPC 403.2) 2. New shower heads shall have a maximum flow rate of not more than 2.5 gpm at 80 psi. (MPC 408.2) 3. New shower and tub -shower controls shall be of the pressure balance, thermostatic, or combination pressure balance/thermostatic mixing type that provides scald and thermal shock protection in accordance with ASSE 1016 or ASME A112.18.1/CSA 13125.1. Handle valves shall be adjusted to deliver a maximum mixed water temperature of 120°F. (MPC 408.3) City of Spring Park 4349 Warren Avenue, Spring Park, MN 55384 Phone: (952) 471-9051 / Fax: (952) 471-9160 / Web: www.ci.spring-park.mn.us 1-4001, SPRING PARK On Lake Minnetonka 4. Domestic dishwashers shall discharge through an air gap fitting in accordance with 807.4 into a waste receptor, a wye branch fitting on the tailpiece of a kitchen sink or dishwasher connection on a food waste grinder. (MPC 414.3) If you have any questions or concerns regarding this plan review please contact me via telephone at 952- 442-7520 or email at codereview(,5-mnspect.com. Regards, 9e f f Vanster fe yer Code Official MN CBO#: B0002824 MNSPECT, LLC Helping You Comply With The Code 235 First St. W. Waconia, MN 55367 0: 952-442-7520 F: 952-442-7521 www.mnspect.com CC: City Property File City of Spring Park 4349 Warren Avenue, Spring Park, MN 55384 Phone: (952) 471-9051 / Fax: (952) 471-9160 / Web: www.ci.spring-park.mn.us 41 Read all attached materials. Everyone performing work to which the code is applicable shall comply with the code. The field copy of these plans must be kept on -site and made available to inspector during all inspections. To schedule inspections call (952) 442-7520 Please have the permit number and street address ready at the time of the call. Plan Revisions All construction shall comply with the approved Ip ans. Plan revisions will not be reviewed in the field without prior approval from the Building Official. Submit all plan revisions to the Department of Building Safety for review, prior to their construction. Reviewed for Code Compliance This review is limited to the submitted scope of work, is based upon the supposition that the plan accurately depicts the intended construction and end -use, that the necessary legal authority has been obtained to construct the project and work is subject to code compliance and field inspection during construction. By: 9 Xfunsferfeiger Type of Construction: Not Applicable Date: 10i5i2018 Occupancy Classification: IRC-1 Single Family IPermit #: 18-54 Code Edition: 2015 MN Residential Code Electrical All electrical must be approved by local Electrical Inspector. For electrical permit inquiries please contact the City of Spring Park Electrical Inspector. Dave Hucky (952) 442-7520 BEFORE YOU DIG Contact Gopher State One Call to locate buried utilities. 651-454-0002 or 800-252-1166 http://www.gopherstateonecall.org/ In accordance with Minnesota law, you must wait 48 hours (excluding weekends and holidays) after you've submitted your dig information to begin your digging project. SCALE: 1/4" = 1'0" Hardwired and Interconnected smoke alarms are required in the following "NEW INTERIOR WALLS TO BE: locations: 2x4 STUDS, 16" O.C. 1/2" SHEETROCK •1 (one) in every bedroom •1 (one) in the area outside every bedroom -At least 1 (one) per floor where no bedrooms exist including basements and 20'-0" Existing spaces wh a njele ical whas taken place ma hary operated smoke ala s not interconnected. 1 (one) Carbon Monoxide (CO) alarm Is v7 required outside of and within 10-feet of X every bedroom or sleeping area. A CO ' alarm is required on every level that contains a bedroom or sleeping area. CO alarms may be hardwired, plugged FIREPLACE: (OVER EXISTING DECK) into an outlet fir 2x10 FLOOR JOISTS, 16" O.C. 1 Adf reguWed•atarm -must be Installed - TREATED 3/4" PLYWOOD O and operational at time of final building 2x6 STUDS, 161e O.C. inspection. 1/2" PLYWOOD (WALL BRACING) . a CEDAR SHAKE SIDING (MATCH EXISTING)FAMILY NSULATION " ` ROOM No domestic dish -washing machine shall MIL. POLY be directly connected to a drainage 1/2" S EETROCK p system or a food waste disposer without the use of an approved dishwasher air gap fitting on the discharge side of the dish -washing machine. uA EXIST. HEADER _ _ _ DN m Mox Cn KITCHEN i I OT II °' II DINING II IC ❑ I ❑Bathroom Ventilation Require � MUD I II rQ E LAUNDRY EXIST. I 114— 5'-3"-j Min. 15" to center of water closet. (typ.) HEADER PROPOSED MAIN LEVEL FLOORPLAN 9/24/2018 Chase Residence EXIST. _ 21185 Viking Blvd. t I Wyoming, MN 55092 MN Lic#: BCO26555 J% SCALE: 1/4" = 1'0" **NEW INTERIOR WALLS TO BE: 2x4 STUDS, 16" O.C. 1/2" SHEETROCK EXIST. PROPOSED UPPER LEVEL FLOORPLAN 9/�4/2018 Chase Residence ' �;oj}3lIlL-I�L-IZ iI;N 21185 Viking Blvd. Wyoming, MN 55092 MN Lic#: BCO26555 LICENSE/CERTIFICATE/REGISTRATION DETAIL RESIDENTIAL Class Type: BLDG Number: BCO26555 CONTRACTOR Application 207671 Status:ISSUED;n No: Effect Expire Date: 3/31/2019 4/1/2017 Date: Print Orig Date: 2/8/1995 1/30/2017 Date: Enforcement NO Action: Workplace N/A Experience: Name:^�BUILDERSBYtiDESIGN''INC Address: 21185 VIKING BLVD NE WYOMING , MN 55092 Phone: 763-434-0631 Business Relationship Requirements Name: SCHULTZ, DANIEL Lic/Reg No: QB111208 C Status: 15155UED�`s Expire 3/31/2019 Date: Orig Date: 2/8/1995 Another Lookup. 1 Application 249551 No: Effect Date: 4/1/2017 �LJ U On Lake Minnetonka JURISDICTION: BUILDING LOCATION: BUILDING DESCRIPTIO REVIEWED BY: File # / Permit #: Date: A> -S (City, County, Township, etc.) ��/a2s 1�/��/� �/� KJ . (Street Address) 'gable of Contents GENERAL GUIDELINES...................................................................................................................................2 ADMINISTRATIVE...........................................................................................................................................2 BUILDING PLANNING (Chapter 3).................................................................................................................3 FIRE-RESISTANT CONSTRUCTION(R302)...................................................................................................3 ROOM PLANNING REQUIREMENTS (R303 through R305)........................................................................3 SANITATION (R306 and R307)...................................................................................................................3 GLAZING(R308).........................................................................................................................................3 GARAGES AND CARPORTS (R309).............................................................................................................3 EMERGENCY ESCAPE AND RESCUE OPENINGS(R310)......................................:.......................................3 MEANSOF EGRESS(11311).........................................................................................................................4 GUARDS AND WINDOW PROTECTION(R312)...........................................................................................4 SMOKEALARMS(R314).............................................................................................................................4 CARBON MONOXIDE ALARMS(11315).......................................................................................................4 FOAMPLASTIC (R302.8, R316)..................................................................................................................4 DECAY PROTECTION(R317).......................................................................................................................4 SITE ADDRESS(11319).................................................................................................................................4 FOUNDATIONS (Chapter 4)...........................................................................................................................4 MATERIALS(R402).....................................................................................................................................4 FOOTINGS(R403)......................................................................................................................................4 FOUNDATION/RETAINING WALLS (11404 - R406)......................................................................................5 City of Spring Park 4349 Warren Avenue, Spring Park, MN 55384 Phone: (952) 471-9051 / Fax: (952) 471-9160 / Web: www.ci.spring-park.mn.us © 2018 MNSPECT, LLC 0 COLUMNS(R407)......................................................................................................................................5 UNDER -FLOOR SPACE (R408)....................................................................................................................5 FLOORS(Chapter 5).......................................................................................................................................5 WOOD JOISTS AND GIRDERS (R502).........................................................................................................5 WOOD STRUCTURAL PANEL SHEATHING (R503.2)...................................................................................5 CONCRETE FLOORS (ON GROUND)(R506)................................................................................................6 DECKS(R507).............................................................................................................................................6 WALL CONSTRUCTION (Chapter 6)...............................................................................................................6 DESIGN CRITERIA (Table R301.2 (1)).........................................................................................................6 WOODCONSTRUCTION(R602).................................................................................................................6 SHEATHING(R604)....................................................................................................................................6 WALLCOVERING (Chapter 7)........................................................................................................................6 INTERIOR WALL COVERING(R702)............................................................................................................6 EXTERIOR WALL COVERING (R703)...........................................................................................................6 ROOF -CEILING CONSTRUCTION (Chapter 8).................................................................................................6 WOOD ROOF FRAMING (R8O2)................................................................................................................6 ROOF VENTILATION (R806).......................................................................................................................7 ATTICACCESS(R807).................................................................................................................................7 ENERGY EFFICIENCY (MN Rule 1322)............................................................................................................7 MECHANICAL(MMC).....................................................................................................................................7 FUELGAS(MFGC)..........................................................................................................................................7 RADON CONTROL MEASURES (MN Rule 1303).............................................................................................7 GENERAL GUIDELINES ®- will require further review of documents before issuing the permit 'j- Deficiency addressed with comment in Approval Cover Letter - Deficiency or plan corrections addressed using a stamp or other markup within the plan -set ,o*- highlight this info on the plan set when provided 0- It is acceptable to receive this information as a deferred submittal with prior approval ADMINISTRATIVE F Permit checked out with Christy? Verify property type on applicable county GIS site, determine Occ Classification Calculation worksheet completed? Permit fees calculated on worksheet only? Required inspections marked on inspections record card? Page 2 of 7 © 2018 MNSPECT, LLC BUILDING PLANNING (Chapter 3) FIRE-RESISTANT CONSTRUCTION (11302) n L �s (11302.1, Tables R302.1 (1) and R302.1 (2)) n er-stair protection (R302.7) Z! i C3-WEril and ceiling finishes (R302.9) Flame spread index (R302.9.1) R� Smoke -developed index (R302.9.2) Testing (R302.9.3, R302.9.4) V ELhuk4ation (11302.10) Flame-spread/smoke-developed (11302.10.1, R302.10.2) B..Gefnbustible insulation clearance (11302.13) it ROOM PLANNING REQUIREMENTS (11303 through R305) 0 Use Area (Ft2) Width Ceiling Height 2 Natural Light 1 Natural Ventilation 1 Living 120 7'-0" 7'-0" 8% Floor Area 4% Floor Area Dining 70 7'-0" 7'-0" 8% Floor Area 4% Floor Area Kitchen N/A N/A 7'-0" 8% Floor Area 4% Floor Area Bedroom 70 7'-0" 7'-0" 8% Floor Area 4% Floor Area Bathroom I N/A I N/A 7'-0" 13 Square Feet 1 1/2 Square Feet 1See sections R303.1and R303.3 for mechanical ventilation and artificial light and R303.4 for required whole - house mechanical ventilation. 26'-8" Minimum ate plumbing fixtures and for non -habitable basements. 9-11ea}uired heating (R303.9) SANITATION (11306 and R307) C Water Closet, Lavatory & Tub or Shower (R306.1) Kitchen area with sink (R306.2) ipal sanitary sewer or private sewage treatment system (R306.3) Fixture spacing (11307.1) .! f� Bathtub and shower spaces (R307.2) i'..i GLAZING (11308) Human impact loads/hazardous locations (R308.4) ® Highlight plan comments regarding safety glazing in Yellow Skylights and sloped glazing (R308.6) Zf GARAGES AND CARPORTS (11309) ETTI tilling/garage opening/penetration protection (R302.5) .! EH5we4ling/garage fire separation (R302.6) Zf EMERGENCY ESCAPE AND RESCUE OPENINGS (11310) S-Where required (11310.1) ❑-Arias, height, width, operations (11310. 1.1- R310. 1.4) li e Page 3 of 7 © 2018 MNSPECT, LLC ffl'V7trrdow wells (R310.2) Zf 0"15M, grilles, covers and screens (11310.4) i`i B-UMer decks and porches (R310.5) MEANS OF EGRESS (11311) [General (11311.1) 4 P�Egress door (R311.2) 14 E;�71_andings at exterior doors (13311.3) .! [Hallways (R311.6) C9 Stairway width, headroom, vertical rise, walk -line (11311.7.1— R311.7.1.4) Stairway treads, risers profiles (R311.7.5) i'.i [-Stairway landings and walking surfaces (R311.7.6, R311.7.7) Handrails required (R311.7.8) i�i Handrail height, continuity, grip -size (11311.8.1— R311.7.8.4) Stairway Illumination (11303.7 & R311.7.8.4) GUARDS AND WINDOW PROTECTION (11312) `� Where required (R312.1.1) .! Height (R312.1.2) ., Opening limitations (R312.1.3) 4t C�Window fall protection (R312.2) .! SMOKE ALARMS (11314) Location (11314.3, R314.5) CARBON MONOXIDE ALARMS (11315) Where required (11315) J. FOAM PLASTIC (11302.8, R316) mace burning, thermal barrier, specific approval (11316.3—R316.6) ® or Zf 0 DECAY PROTECTION (11317) i�tr tection required (R317.1) .� C_jplwd/Plastic composites (R317.4) -! SITE ADDRESS (11319) B,A.ddress numbers (R319.1) .! FOUNDATIONS (Chapter 4) MATERIALS (11402) B-_ crete, compressive strength (Table R402.2) of FOOTINGS (11403) E4-Footing width (11403.1.1 and Table R403. 1) A Highlight interior strip footings, and all pad footing and footing size callouts in yellow Page 4 of 7 © 2018 MNSPECT, LLC fftfnt protection (R403.1.4) .! Ef-Prrundation anchorage (13403.1.6 & Table R404.1.1 (1)) it 216otings adjacent to slopes (R403.1.7) kO FOUNDATION/RETAINING WALLS (11404 - R406) E4g0nonry wall height, unbalanced backfill, nominal thickness, reinforcement spacing (Tables R404.1.1 (1) - R404.1.1 (7)) 'ffrtuncrete wall height, unbalanced backfill, nominal thickness, reinforcement spacing (11404.1, R404.1.2.2, Tables R404.1.2 (1) — R404.1.2 (4)) Wight above finished grade (R404.1.6) 4Q-�9&plate size, Min 2x4 size (R404.3) 1. Q Brains required if habitable or usable spaces are below grade (R405.1) 41. CLQgperete and masonry foundation waterproofing (R406.2) it COLUMNS (11407) E;- tection from decay or corrosion (11407.1 or R407.2) E-Wuctural requirements (R407.3) al. B-Wood columns (minimum 4" square) (R407.3) E -S eel columns (minimum 3" diameter, Schedule 40 pipe) (R407.3) UNDER -FLOOR SPACE (11408) ventilation (13408.1— R408.3) [;-Access (R408.4) .? LI.E_nished grade (R408.6) Zf FLOORS (Chapter 5) WOOD JOISTS AND GIRDERS (11502) Et'Aftowable Joist Spans (Tables R502.3.1 (1) — R502.3.1 (2)) E-Cz tilevered joists (Tables R502.3.3 (1)) er spans and header spans for exterior bearing walls (Tables R502.5 (1) & R602.7.1) ® Highlight all beam & header sizes. Conventional materials in light orange, engineered materials in light purple. Girder spans and header spans for interior bearing walls (Table R502.5 (2)) ® Highlight all beam & header sizes. Conventional materials in light orange, engineered materials in light purple. EJIoist minimum bearing (R502.6) .! 1;i a eral restraint and bridging (502.7, R502.7.1) at CIF ming of openings (13502.10) S-Wood trusses (11502.11) at EE-Draft-stopping (11302.12 & R502.12) .f B-Rre protection of floors (11501.3) .o WOOD STRUCTURAL PANEL SHEATHING (11503.2) 9-Aftwable spans (Tables R503.2.1.1 (1) and R503.2.1.1 (2)) Page 5 of 7 © 2018 MNSPECT, LLC CONCRETE FLOORS (ON GROUND) (11506) ff''Mkness (R506.1) J. P-Wpor retarder (P506.2.3) .! DECKS (R507) B.JJse the Deck Code Review Record if home has a deck, wood framed front porch or covered deck/porch. WALL CONSTRUCTION (Chapter 6) DESIGN CRITERIA (Table R301.2 (1)) C—esign wind speed (Table R301.2 (1)) OO :i mind exposure category (Table R301.2 (1)) ©` i WOOD CONSTRUCTION (11602) mud spacing exterior walls up to & including 10-feet (R602.3.1, Table R602.3 (5)) k� 0 ItMd spacing exterior walls over 10-feet (R602.3.1, Table R602.3.1) 4 0 n erior load -bearing walls (R602.4) OE�GMple walls (R602.9) 4f C+-Fire-blocking (11302.11, R602.8, R602. 11) 4 LI-Wall bracing method, Braced wall lines, Bracing panels (R602.10.1, R602.10.2) 0 C�,Aequired length of bracing, (R602. 10.3, R602. 10.4, R602.10.3(1) and P602.0.3) Q.Minimum length, connections, support, joints, cripple walls (11602. 10.5 - R602. 10.11) SHEATHING (11604) S- eod structural panels (R604) .. WALL COVERING (Chapter 7) INTERIOR WALL COVERING (11702) Vapor retarders (R702.7) Zf EXTERIOR WALL COVERING (11703) E-'dbFeter-resistive barrier (R703.2) J. 9-Aeffiered masonry veneer (R703.12) .! ROOF -CEILING CONSTRUCTION (Chapter 8) WOOD ROOF FRAMING (11802) EH- ,,esign & construction (R802.2) © 4 O-Wood trusses (R802.10) Zf fiftof tie -down (R802. 11) .! Page 6 of 7 © 2018 MNSPECT, LLC S—Ti-kkness & allowable spans (R803.2.2 & Table R503.2.1.1(1)) ROOF VENTILATION (11806) D-Ventilation requirements (11806. 1— R806.5) ATTIC ACCESS (11807) D-�ess requirements (807.1) it ENERGY EFFICIENCY (MN Rule 1322) Construction Documents (1322.0103) nsulation materials and their R-values; stration U-factors and SHGCs; 4 CT -"a -weighted U-factor and SHGC calculations; .! E M shanical system design criteria; & Interior Design Conditions +/- 2° (MNRES R302.1) Heating Maximum 72'F/22°C Cooling Minimum 75°F/24°C Winter design dry bulb temperature +/- 2°(MNSREC Table 1322.R403.5.17) Minneapolis/St. Paul -15°F it Summer design dry bulb/wet bulb temperature +/- 2° (MNSREC Table 1322. R403.5.17) Minneapolis/St. Paul 88°/72° F -o 0-�hanical and service water heating system and equipment types, sizes, and efficiencies; &LZLwct sealing, and the location and insulation of ducts and pipes; a [] Ai,r sealing details..! ❑ Duct Insulation (MNSREC Table R403.2.1) .! MECHANICAL (MMC) Ctppliance access for maintenance and replacement (MMC 306.1) .! Et -Appliances in rooms (MMC 306.2) 1. C�keup air (MMC 501.4.1) ©'i.i Fj� ® note size from worksheet on plan, highlight in yellow FUEL GAS (MFGC) D'Mhibited locations (MFGC 303.3) -B-FLrotection from vehicle damage (MFGC 303.4) .! M-Efevation of ignition source (MFGC 305.3 & 305.3.1) Zf 8-,appliance access for maintenance and replacement (MFGC 306.1) Zf appliances in rooms (MFGC 306.2) .! 1:1 mbustion air (MFGC 304.1) ©z.i ® Q A note size from worksheet on plan, highlight in yellow RADON CONTROL MEASURES (MN Rule 1303) 9-Applicability and design features (MSP 1303.240.0 Subp. 2) Zf Page 7 of 7 © 2018 MNSPECT, LLC