Permits - Permit# 14-06 - 2437 Black Lake Road - 1/1/2014CITY OF SPRING PARK 20
4349 Warren Avenue Spring Park, MN 55384
Phone (952) 471-9051 Fax (952) 471-9160
BUILDING PERMIT
k" &anarkerin ffiefio
Monday - Friday before 7 a.m.
and after 10 p.m.
Weekends/Holidays before 7
a.m. and after 8 p.m.
t 0 c
F
3 —
Q
DATE a — OI
CHANGES TO APPROVED BUILDING PLANS MUST HAVE CITY APPROVAL
SITE ADDRESS (9L f �L� �. _ PID
OWNER Name/ Address/ City/ State /Zip
JV�-i - k. k i
w ,11rA�-
a',l 3 �- Q1,0�Lk- A
4
CONTACT NAME - PHONE - EMAIL - FAX %k Nr
1 a 6P
ARCHITECT (if Reawred) Name / Addres. I "Rate Zip Phone
CONTRACTOR Namq Address / City'
s-j (
" -('-.
CONTACT NAME - PHONE - EMAIL - FAX
CONTRACTOR LICENSE # a0 ZT 4,
0 - 1
TYPE OF WORK
❑ New Home
❑ Deck
❑ Re -Roof
❑ Commercial Residential
❑ Addition
❑ Fence Height:
❑ Re -Side
EST. VALUATION OF WORK
❑ Remodel
❑ Pool
❑ Ret. Wall Height:
$ r7S d U i>
krinish Basement
❑ Stucco Demo
❑ Window Replacement
Building Height: Feet
❑ Accessory Structure
❑ Stucco
❑ Other:
# of Stories:
SCOPE OF WORK:
d& c—..
Use of Building:
rp t)-v-,
Signature of this application by the legal property owner or a licensed contractor, as the owner's representative is required and authorizes the City Zoning Administrator or designee and the City Building Official or designee
o enter upon the property to perform needed Inspections. Entry may be without prior notice. I hereby acknowledge that I have read this application and state that all information is true and correct to the best of my
knowledge. I further agree that all work performed will be In accordance with approved plans, specifications and conditions and to abide by all ordinances of the City and the laws of the State of Minnesota regarding actions
ken pursuant to this permit. I agree to pay all plan review fees even H 1 ch not to proceed with the rk. Permit expires when work Is not commenced with 180 days from date of permit Issued, or if building and
work Is suspended, abandoned or not inspected for 180 days. Work ontl or 'thout a permit or Ins o will be subject to a penalty.
Call MNSPECT for Inspect s t (952) 442-75 4 Hour Notice) 8:00 a.m. - 4:30 p.m.
SIGNATURE OF APPLICANT:
DATE: —
PRINTED NAME:
JDATE: —kD(CP
--------------------------- ---------------------------
LEGAL DESCRIPTION: Lot Block Addition Zoning
Valuation of Permit: $ 25;CM •QL)
Lot Area:
OCCUP. TYPE: Z CONST. TYPE: VU — CODE: BLDG SPRINKLED
Yes /
SETBACKS: REQUIRED ft)
ACTUAL (ft)
*NOTE: Commercial plans will
be submited to the Met
Council Environmental Svcs
for SAC (sewer availability
charge) determination.
Escrow payment will be
required when permit is
issued. If after Met Council
review no SAC is determined,
escrow will be refunded in full.
Permit Fee:$
Front ROW
Plan Check Fee:$ 2
Rear
State Surcharge:$ 6
Side
Site Insp. Fee:$
Side
Muni SENVA Fee:$
Corner
S.E.0 Fee:$
Lakeshore
*2014 SAC Escrow :$2,485
Wetland
WAC Charge:$
Other
SewerB H2O Hook -Up:$
Sewer & H2O Disconnect:$
Water Meter:$
Paid
Receipt No.
L Other:$
Date
By
TOTAL DUE:
-
BUILDING APPROVAL BY:
TIME: : 30
CITYAPPROVAL BY:
DATE:
TIME:
All new construction and/or dwelling expansion shall require a certified survey dated within five years of application.
All new construction and/or dwelling expansion will be subject to contracted planner review and may add to the review time.
)I
NSPECTION RECORD
PERMIT NUMBER 2 '+
Location
Type of project
Description of prof ct S
t
Permission is hereby gr nted to:
/4 r �
to install or construct the improvements applied for. This permit is granted
upon the condition that the person to whom it is granted, and his agents,
employees and workmen, shall conform in all respects to the Ordinances
of the Municipality of�
and to the Statues of the State of*AinnesotpKn such cases made and provided;
this permit may be revoked at any time upon violation of any of the provisions
of said Ordinances, Statues, or for any misrepresentation in the application.
NOTICE
This card and reviewed construction plans must be posted at the worksite
and maintained until all inspections have been approved. NO
INSPECTION will be performed if card and plans are not available to
inspector. REINSPECTION FEE WILL BE CHARGED. NO
DEVIATIONS FROM THE APPROVED PLANS ARE ALLOWED
WITHOUT PRIOR CONSENT FROM THE BUILDING INSPECTIONS
DEPARTMENT.
Do not occupy until all final inspections have been completed.
Permit expires when building and work is not commenced within
180 days or If building and work Is suspended, abandoned or not
inspected for 180 days.
CALL FOR ALL INSPECTIONS
24 HOURS IN ADVANCE
8:00 A.M. to 4:30 P.M.
Monday thru Friday 952-442-7520
Non -Metro 1-888446-1801
DATE
BUILDING INSPECTIONS
Note: Permit'holder Is responsible to call for these inspections.
Required inspections are circled.
Date Inspector
S.E.C.(before excavating)
Footings (before pouring)
g
MECHANICAL & PLUMBING INSPECTIONS
Date Inspector
Plumbtng Rough In
Plumbing Final
Heating Rough -In
GAS LINE
Heating Final S
Fireplace Rough -In
GAS LINE
Fireplace Final
Elec rcal ugh -
Electrical Final
fF
�a ,L i r , ,F
Municipality: Springy
Project: basement finish
Office Use Only
Plan Review Comment Sheet
#R14-034
Applicant: Matt & Nikki Willette/Finished Basement Co
Valuation: $25,000.00
Permit #:14-0 (v Address: 2437 Black Lake Rd
Date Issued: Inspector Issued:` Number of Days:
Date & Comments
2/19/14
Received application and plans
wm
ZIP40-
0 Municipality plans at MNSPECT
MUNICIPALITY
FILE COPY
READ ALL ATTACHED MATERIALS!
NO OCCUPANCY OR USE ALLOWED
UNTIL FINAL INSPECTION AND APPROVAL
CALL BUILDING INSPECTOR 952-442-7520
OR A FEE MAY BE CHARGED
INSULATE FOUNDATION
BASEMENTS AND EVERY SLEEPING ROOM
SHALL HAVE ONE EMERGENCY ESCAPE
WINDOW OR DOOR WITH A SILL HEIGHT OF
NOT MORE THAN 44" ABOVE FLOOR AND
SHALL BE NOT LESS THAN 5.7 SQ. FT. OF
OPENABLE AREA. NET CLEAR OPENABLE
WIDTH OF 20" AND HEIGHT OF 24" MINIMUM
Smoke detectors are required in each sleeping
room, outside each separate sleeping area in
the immediate vicinity of the bedrooms, and
on each story of the dwelling. wall mounted
detectors should be located inside an area
not more than 12" and not less than 4" from
the ceiling. Ceiling mounted detectors
should be no closer than 4" from a side wall
or peak of a vaulted ceiling.
Carbon monoxide detectors are to be located
within 10' of each room lawfully used for
sleeping purposes.
ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL
HAVE WALLS, UNDER STAIR SURFACE AND ANY
SOFFITS PROTECTED ON THE ENCLOSED SIDE WITH %z -
INCH (13mm) GYPSUM BOARD.
ALL SILL PLATES MUST BE OF REDWOOD, CEDAR, OR
TREATED LUMBER.
EGRESS WINDOW WELLS SHALL PROVIDE A
MINIMUM NET CLEAR OPENING OF 9
SQUARE FEET, WITH A MINIMUM
HORIZONTAL DIMENSION OF 36 INCHES.
WINDOW WELLS WITH A VERTICAL DEPTH
OF MORE THAN 44" SHALL BE EQUIPPED
WITH A LADDER.
PROVIDE CLEARANCE TO COMBUSTIBLES PER MECHANICAL
CODE FOR ALL VENTS/CHIMNEYS CONVEYING
COMBUSTION PRODUCTS.
PROVIDE OUTSIDE COMBUSTION AIR TO
FURNACE AREA.
MUST POST ADDRESS ON
CONSTRUCTION SITE
VISIBLE FROM ROAD.
.............................................................................
If Bathroom Beina Finished
• SEPARATE PLUMBING PERMIT REQUIRED
• EXHAUST FAN MAY BE REQUIRED
E • EXHAUST FANS MUST BE VENTED TO
OUTSIDE AIR. INSULATE DUCT IN
UNHEATED SPACES
• PLUMBING ACCESS PANEL REQUIRED FOR
TUBS
L....................................................................................................
............. ............. .......................
,
If Fireplace Beina Installed
• SEPARATE MECHANICAL PERMIT
REQUIRED
• CALL FOR ROUGH IN
• GAS LINE
• AND FINAL INSPECTION
:....................................................................................................:
EVERY PERSON PERFORMING WORK FOR WHICH
THE CODE IS APPLICABLE SHALL COMPLY WITH
THE CODE.
ATTACHED PLANS REVIEWED AND
APPROVED IN ACCORDANCE WITH THE
MINNESOTA STATE BUILDING CODE.
ATE22-&- -14
FOR ALL INSPECTIONS CALL (952) 442-7520
24 HOURS IN ADVANCE AND GIVE
PERMIT NUMBER IZ-1-06
Supplement to Basement Finish Permit Application
(must be included when applying for permit)
The following information is required when applying for a Basement Finish permit
application. (some of this information may also be listed on your plans)
1. Exterior Wall Construction:
a. Size of studs/stripping 94 q
b. Spacing of studs / C
c. Type and thickness of insulation
d. Vapor barrier (i.e. 4 or 6 mil polyethylene) ea(.'Afiso
e. Wall covering (i.e.'/" sheetrock) %�_ sae_
2. Interior Wall Construction: /
a. Size of studs . GI Y �-
b. Spacing of studs 1 (v D C_.
c. Wall covering (i.e. %' sheetrock) c
3. Ceiling Covering (i.e. '/" or %" sheetrock)
<<
4. Plumbing to be installed (check one for each bathroom)
a. NONE
b. '/ bath on existing rough -in plumbing
C. % or full bath on existing rough -in plumbing
d. '/z bath including new rough -in plumbing
e. 3/ or full bath including new rough -in
f._ other (please specify) \
5. Heating to b installed (check one)
a._ Extend supply and returns
b. Use existing with no changes
C. Other (please specify)
6. Will a Fireplace be installed?PYes ❑ No
Type of Fireplace
7. Total square footage of the finished basement area?
July 10, 2007 Basement Finish Page 4 of 5
License/Certificate/Registration Detail
Class Type: RESIDENTIAL BLDG
CONTRACTOR
Application No: 225700
Expire Date: 3/31/2016
Orig Date:
Enforcement
Action:
7/21/2004
NO
Number: BC460771
Status: ISSUED
Effect 4/1/2014
Date:
Print 2/17/2014
Date:
Name: THE FINISHED BASEMENT COMPANY INC
Address: 11666 FOUNTAINS DR
MAPLE GROVE, MN 55369
Phone: 651-224-7000 Fax: Other:
Business Relationship Requirements
Name:
COOK, MATTHEW D Lic/Reg No: QB132171
Status:
ISSUED Application No: 261943
Expire Date:
3/31/2016 Effect Date: 4/1/2014
Orig Date:
7/21/2004
Another Lookup?
https:Hsecure.doli.state.mn.us/lookup/licensing.aspx 2/ 19/2014
Construction
Notes
//,///
F INSED FINISHED BASEMENT COMPANY INC.
Trim Cabinetry Notes - Homeowner provided, materials
and labor
Cl 1/2" firerock underneath stairs perCl17Frame
for angled ceilingand bench
code and on adjacent walls
c2 .
Existing framed walls
seat in steam shower/���������������//j/
Phone. 651.224.7000 Fax: 763.515.1057
B ASEMENT
C3 Maintain 36" clearance of framing in
front of electrical panel and furnace
������������� �
www.f I n Is hed baseme nt. corn
N
T1 Trim and cabinet notes are for
C OMPANY
framing reference only, (unless
C4 Dimensions for cabinetry are drywall
otherwise specified), FBC not
finished, reference elevations
responsible for the outcome of these
C5 Wall cabinet backing at (92)"AFF
r�
More 'Va Value Less Hassle.
finishes and materials, for reference
only. All materials and labor to be
C6 Location of bath hardware, addprovided
...
by homeowner
backing: 58"AFF towel ring, 48"AFF
towel bar, 22-1/2"AFF TP holder
C7 Frame for exact size of shower pan
(72 x 41), extend end walls 2-1/2"
T2 FBC to provide &install temporary
past pan
handrail, per code
C8 Back lit drywall tray ceiling w/rope
lighting (without crown molding),
(Square profile - no bevel, 4"H x 3-1/
°a
'17 10"
\
T3 Flush MDF access panel for
2 D
C9 Provide backing in wall for projection
$ a At';D rlY SLEEPING R SMALL
electrical panel
M
screen
C10 Drop soffit (10)" from ceiling in
I I GFC
KaVE ONE EMERGENCY ESCAPE 1 NDOii�r OR DOOR
OF Ida i MORE N " ABOVE FLOOR MID
T4 Frame and install (24 custom
flush
theater area
F
y=0 i A SILL HEIGHT
NOT LESS THM .7 ' FT FfNo"
panel paint grade door; no
a
lockset, visible hinges, with base,
C11 Drop ceiling in bathroom (15)"
W3
SHALL BE
NET CLEAR ® `AE'
touch to open To be addressed as
C12 Shower niche in shower above
bench: 24"W x 15"H, 56"AFF
Un i shed Storage
85 sq ft OO a f Stairs and ai
127 sq ft FU
change order
C13 Knee wall at wet bar 40-1/2" rough 6"
thick
1-11„
°
SMOKE DETECTORS REQUIRED ON EACH
Carbon Monoxide Detectors 1N BASEMENT, LOCATED IN EACH
WH 1�9
\
STORY ,AND
C14 FBC to provide & install temporary
/ I
are required within 10 feet SIM2INO ROOM AND AT A POINT C;7f i'TRAtti
handrail, per code
L 3 0dN?J f l :j � u P
of each room ia�wiuliy used LOCATED IN TM AM ACt�ESSiNG
C15 (14) 1 x 4 paint grade boards,
for purposes EACH SLEEPING RAOM Am SHALL. BE
creating 18"W x 14"H squares, (12)
RCONNECM.
18"W 1 x 4 on each side of tv wall,
. 1
interior of squares to be touch latch
o I 1
to store lake fun
1 I I
C16 Frame for fireplace cutout for Heat N
Cp = Carbon (Monoxide Detector/Alarm
EXHAUST FANS MUST 6E VENTED
TO OUTSIDE AIR.
Glo Cosmos, without fan: framing
dimensions (50)"W x (42-1/4)"H x
o
INSULATE =Exhaust Fan
0
DUCT IN
(18-1/4)"D, (18)"AFF (to exposed
UNHEATED SPACES.
part of fireplace), (drywall) finish
_
SD = Smoke DatsctOr/AIsrrn
WITH TONIC FOG FRONT
I DM
T 64 ft
° I I
MALLBOARD UNDERSIDE OF
i
GFc I
Q
ALL SILL PLATES MUST
BE OF REDWOOD CEDAR
^ OA TREATED LUMBER.
Electrical Notes
E1 Smoke detectors will be installed per
E16 (4) Basic ceiling lights
code in upstairs living space
E17 Dedicated 240 V, 21 AMP supply for
F
a�
—
L I i Wirie I set
E2 Use existing sub panell install new
steam unit, install control wire
EF. 21S(111
electrical sub panel
E3 Provide construction lighting and non
provided by FBC
E18 Wire for H/O provided temperature
- I
Bar I I
37 sq ft
PROVIDE 'CLEARANCE TO
Provide Outside Combustl0ll COMBUSTIIBLES PER MECIFO.
GFI outlets
control unit:
I
oM
Air To Fumace Area or Th§ CODE FOR ALL VENTSICHIMNEYS
E4 Relocation of security panel &alarm
sensors not in the FBC's scope of
15 Amp 110 -120 V line
oM
ABiumAirD= CONVHYING COMBUST"
��iiT�,
Door Schedule -Homeowner provided materials and labor
work, homeowner responsible to
VERIFY LOCATION
,,;, � U. „ - �
oMt
relocate all security sensors
E19 (9) Basic pendant fixtures mounted
D1 (1) 2668 Stain grade, 2 panel, Maple
D5 Frame and install (2445) custom
E5 Homeowner responsible for final
(72)"AFF to bottom of fixture
! 1
flush panel paint grade door, no
connection of CAT-6/telephone,
p
satellite and cable (Done by
E20 3 Keyless fixtures
O y
°
/
/
D2 (1) 3068 Stain grade, 2 panel, Maple
lockset, visible hinges, with base,
touch to open To be addressed as
Homeowner's phone and cable/
E21 (3) Undercabinet (recessed) puck
a
/
change order
satellite_ _ - _
��nYi
I ligh s; Sea Gu11 Disk Lighting Kits,
t, 9 9
i
-
D3 (1) 4068 STAIN GRADE, 1-lite,
DH1 Door hardware: Compliment upstairs
O
E6 All outlets and switches on back bar
#9889-298 w/bulbs
E22
°
exterior grade doors into wine closet
profile/If not able to find, FBC will
wall to be mounted 45" AFF to
Dedicated 20 AMP circuit for
microwave/refrigerator erator
g
—
_
D4 (1) Existing exterior door
provide a comparable profile with
j/
center
E7 (1)-existing and (2)-new smoke
E23 Tread lights: Nora Lighting, NSI-
homeowner's Consent (Brushed
Nickel), w/standard hinging
(2)
detectors to be hardwired, battery
back-up, interlocked, one of which to
661, mini LED
(�
g Area
j
Floor & Tile Notes
F1 Homeowner Provied Carpet, Pad
F7 Tile on walls in shower, up to ceiling,
be C.O./smoke detector combo
E24 Rope lighting to be concealed from
�G
323 ft
a°
E8 18 Electrical outlets in project,
( ) p j
view in back lit tray ceiling, outlet w/
E31 Digital Surround and Single Video
�_
and Install
including ceiling, (2) cut the shelves
(white), placed per code
1/2-hot switch to control light
Source Prewire (includes, HDMI,
Component Video & speaker wiring)
on 45 degree angle in comer w/
E9 (3) GFI outlets in project, (white),
E25 Dedicated 15 AMP circuit for
Wiring will run from one point of
° "
F2 Standard the install, no special
bullnose band
See Selections Packet for details
placed per code
components
connection to either a projector or a
p j
inlays, accents, etc.
F8 In floor heat under tiled areas (bar
E10 (3) AFCI branch circuits in project
E26 All outlets at wet bar to be color:
wall mount television. Prewire for
F3 Durarock or equivalent
and entry)- see plan for transition
Ell (2) CAT5 jacks with CAT6 wire / (2)
TBD
any other areas or any other system
\
F4 Tile floor in bath:
line in entry
cable jacks provided by low voltage
E27 Electrician to provide low voltage
other than listed above will be an
additional cost. Equipment such as
\
See Selections Packet for details
F9 Tile floor in shower:
See Selections Packet for details
company
switch for fireplace ignition
TVs, Components, Remotes,
F5 Tile floor in bar and living area:
F10 Tile for shower bench:
E12 (5) Switches, (11) 1000-watt
E28 Wire thermostat for steam unit
Speakers and Control panels not
See Selections Packet for details
See Selections Packet for details
dimmers, (rocker), (white)
E13 (1) Panasonic exhaust fan for steam
E29 Provide disconnect for steam unit
included.
F6 Tile floor in entry:F11
Tile floor in wine cellar:
shower application:
place per code
°
_ _ _
_ _ _ _ _ _
_ _ _
See Selections Packet for details
See selections packet for details
(FV 11VQ3), 110 CFM, placed per
E30 In floor heat under tiled areas (bar
a
Countertop Notes - Homeowner provided, materials and
code
and bath)- see plan for transition line
E14 (16) 6" Recessed cans, white trim
in entry
�°
E
labor
baffle
s ® DM
a
CT1 Wet bar countertop: 25-1/2"D granite
CT4 Bar backsplash: full -height tile
E15 (1) Waterproof trim kit for 6"
slab:
See Selections Packet for details
CT2 Homeowner Provided Vanity
backsplash:
See Selections Packet for details
Plumbing Notes
21049 21049
P1 Use plastic clean -out covers on walls
P8 H/O provided Bath accessories, FBC
Furniture piece, FBC to Install
and chrome clean -out covers on
to install
floors
Pg H/O provided Steam Unit: Amerec
P2 If moving or installing water lines
(AK-7), 240 V, 21 AMP, with (K60)
LIVING AREA
CT3 Bar top: 18"D granite slab, 1"
near exterior walls, provide thermal
control, (brushed nickel), w/ floor
937 sq ft
overhang on bar side of supporting
break between concrete & framing
drain, FBC to install
wall:
P3 Provide water supply and drain for
P1 p Provide water line &drain line for
See Selections Packet for details
bar
refrigerator in unfinished storage
Wall Finish Notes
P4 H/O Provided Lavatory sink and
area
faucet, FBC to install
P5 H/O Provided Shower faucet with
PI Include water filtration rough -in at
bar, replumb with 1/2" to kitchen and
W1 Knockdown texture for ceiling and
W9 FBC to do primer coat for walls and
arm, FBC to install
utility
flat texture for walls
ceiling (homeowner responsible for
P6 Poured shower (72)"W x (41)"D
sanding of walls & final wall paint)
pan
Beam C _
Central Vac Unit
_
Sub Panel
New Single Pole Switch
Custom Plan For The Lower Level Of
G U a ra nteed T I m e L I n e
W2 Wall comers: square
(1) Color flat finish overall, semi
P7 Toilet: See Selection Packet for
details
Support Column • ■
Humidifier/Fresh Air ® \ a" h
Telephone Panel ®
New Dimmer Switch oM
Start Dater Finish Dater ,
W3 Durarock or equivalent
W4 Use (12) drywall sheets
gloss in (bathroom)
See Selection Packet for details
Existing Foundation 0
Furnace/Air to Air F_FURNACEI
Cable Panel �
New 3-Way Switch 3
Working Days To Completion Date: —�—
W5 Clean out covers to be painted same
W10 Paint and staid materials and labor
HVAC Notes
Exchanger — — — 7 1 i I
1 I 1 `1'
The W i I I ette Residence
FBC is not responsible for supplying or installing any items, fixtures, or features that are not specified on the
Final Plan. All construction details will be built to industry standards, unless specified differently. The
color as walls
to be provided by homeowner
H1 General existing: Forced air
H6 Frame for fireplace cutout for Heat N
Knee Wall
A -A
L — _ _ J
Alarm Ranel ®New
3-wa y Dimmer Switch 3DM
undersigned acknowledge that any subsequent changes, alterations or modifications shall be subject to a
W6 Unfinished utility/storage do not
H2 6 New dropheat registers
() g
Glo Cosmos, without fan: framing�
„ „
dimensions (50) W x (42-1/4) H x
Existing Wall
_ _ _ �
Water Heater
Alarm Sensor y® 8D
New Duplex Outlet
p
Change Order and billed accordingly. The undersigned further understand that the said, Final Plans shall be
regarded as the definitive plans for contract purposes and that no reliance may be made upon any previous
include sheetrock or any finishing
Two layers of 1/4" drywall for all
H3 (1) Exhaust fan Panasonic
(18-1/4)"D, (18)"AFF (to exposed
Interior Wall
�1Nhl/�
Water Softener System $� WS
W
Central Vac Outlet
New GFCI Outlet
Plan: Pre -Pre
verbal statements made by the staff, employees, subcontractors, suppliers or agents of Finished Basement
arches or radius walls
(PAF FV-08VQ3) placed per code
part of fireplace), (drywall) finish
GFC,
company. Unless otherwise specified, all outlet, lighting and switch locations are approximate but are placed to
H4 Add Cold air return per code
p
WITH TONIC FOG FRONT, need
core drill
Exterior Wall
Toilet/Shower Rough far
g T .
New Smoke Detector so
New 1/2 Duplex Outlet
code. The Finished Basement Company is not responsible for the levelness or condition of the existing floor,
and existing walls, including but not limited to squeaking sub floors or stairs. The moving of or removal of all in
W8 Scrape and respray stairway ceiling
for knockdown texture
H5 (0) Existing drop heat registers
H7 Move gas lines in hall
Existing Heat Vent °�"'"° �® -,
F=R--
New Heat Vent �.L -�0
L —J
Clean Out FC 'WC
�
Floor Drain/Shut off valve [3
Water Main
New Exhaust Fan H
New Keyless Fixture (3)
New Flourescent Fixture 0
New Cat 6/TV Jack
WN
New Telephone
Date: 01.14.14
home fire sprinkler, and security items are the homeowner's expense and scheduling responsibility. Estimate
subject to change upon selection of lighting and fixtures. Working days to be determined by project manager at
pre -construction walk.
Client Signature: Date:
Insulation Notes
11 Wall insulation: Present
12 Ceiling insulation: R19
14 Insulation between all water lines &
concrete walls
13 Block cold air returns with insulation
15 Water line near exterior vent pipe,
Existing Cold Air Return
SP
9
New Central Vac
�� _. ��
SCALE: 1 /4 = V -0
Client Signature: Date:�
wrap vent pipe w/insulation
Sump Pit
New Recessed Can
FBC Representative: Date:
FBC
CU 00
LC;
U-) Q0
a)ZI`
C LO
Z V L
r N
CU W 'r
CUM
NCL
^
V,
co
U
�
Z
LO
O
Ln
06
L
Z
Z
W
O
w
c
i
W
W
Q
N
2)
O
U)
m
U
W
a.-�
i
LIJOO5
U
N
E
Z
CU
U_
N
l"—
�O
L—
a.
Unfinished Ceiling Height: 109
Beam Height: n/a
Ceiling Joists O.C.:
Insulation: existing
Sump Pit: not existing
Electrical Panel Amperage:
(200) AMPS - (9) OPEN