Plans - 3829 Park Lane - 5/28/2021t VILI AGE OF SPRING PARK
WARMING HOUSE -SPEC . SHEET
FOOTINGS: V-2.0"-rerimeter of building, 6 courses 12" blocks-5 courses
below grade-lcourse above grade-50" from bottom of footing trench to fin-
ished grade. 1
SILL PLATE: 21,-6 perimeter of building.
FT_,OUT', JOISTS: 2-r1.0-16" O.C. to span 11'83/4".
SUB FLOOR SHEATHING: 4x8x''2" plywood CDX exterior glue -spray painted for
extra Ovate p—oori_n?, protection.
F T_NISiI T� L001Z.: 4x,9x'-_" plywood CDX exterior glue -spray painted for extra
waterproo-`--any; ?rot-ecti.on,
WALLS: studs to be 2x4-construction grade 16"O.C.- headers to be 2x10 bible.
over all and door openings.
EyTEI:IO?' 4x8x-'5" hard base nail base built -rite composition
sheathi_n�-_ all corners -rough window openings and rim joist to be covered
-.•pith 1..5 lh. felt_. Finished siding to be 7/16"xl2" masonite hard -board
siding set 10" to weather exposure.
T`7ERI�)I'. ! T? �.SH: 3';"full thick fiberglass insulation -covered by 4 mill
nolysheet vapor barrier -covered by'4x8x2" CDX plywood exterior glue-
+'FTLINGSO.C. -6" fiberglass batt insulation -covered by 4 mill
holy sheet_ vapor barrier -covered by 4x8x2" CDX plywood exterior glue -spray
'AFT ET?S: 2x4-1611 O,C. with ridge t.issand "W" bracing 4° O.C.-roof sheathing
4x x'-," G �� nI_y<-ood-16x32 span spec. covered entirely with 15 lb. Bldg,
felt- paper, %ll outside or trailing edges of roof to be covered by "T"
s ryl_e me is l nd7 ng-covered by 240 lb. asphalt roofing.
LECTRICAI.: 200 ramp service entrance for interior and exterior lighting -
wiring to co,--F-)�-m to State and Local Codes.
U
I..T" t : to col:iform to all Local and State Codes-i%Tater to be from Mun-
icipal se-,7,,ice- nd future plan for toilet facilities to be from Municipal
service-te por ry se`.7er service by cottmue-riz-1al contractor.
a�ICKEV `:Ti1' : _o be of regulation size 90 ft. by 200 ft. as per plat plan
enclosed.
`rI' ST':E'sT 1'A:'�! Ti', to conform to ordinance as per plat plan -present and
fut: r. e de�_�el npm.ent.
Poor Quality Document.
Disclaimer
The original or copy of a document or page of a document
presented at the time of digital scanning contained within this
digital file may be of substandard quality for viewing, printing or
faxing needs.
. I '
i
c{
C
y f
,
I ��I
i
hh tt /
eliif
L L� r`� Y/�l /�, '<•" %�� i.%S,F , ��siy' Ci:�' !' /i /.ter .%S'
DRAWN BY DATE REVISIONS
CHFCKItD BY
APPROVED BY
SCALE:
TITLE • > DRAWING NUMBER
DATE
7 r
9vl.
r . r
-�j94PoS�
t
0
I
i
4- /
I � •1 � r
i
----•�•- --- - --- --- ----- --- . _.r ._ _ ._ - -------- - - - - -- - .. - - - -----• EGG - -- --- ----- ------------ --- --- -- - - - - --
�i'S f/�,c,c �./GAG' c•� 09�c/�i9s�'Y
z"�•
•� L � 7/ !]/' /A CJ may- 7
f ! . //�/ 1n)�i Y /� /P�i�•/ lif
o:
i I
.
-
D WN B
DATE
REVISIONS
DATE
CHECKED BY
APPROVED BY
SCALE:
TITLE
DRAWING NUMBER
r-
i'.�,_.
���,vs �����k—
.It
VILLAGE OF SPRING PARK
WARMING HOUSE -SPEC. SHEET
FOOTINGS: 8"x20"-Perimeter of building. 6 courses 12" blocks-5 courses
below grade-lcourse above grade-50" from bottom of footing trench to fin-
ished grade.
SILL PLATE: 2x6 perimeter of building.
FLOOR JOISTS: 2x10-16" O.C. to span 11'83/4".
SUB FLOOR SHEATHING: 4x8x2" plywood CDX exterior glue -spray painted for
extra waterproofing protection.
FINISHED FLOOR: 4x8x2" plywood CDX exterior glue -spray painted for extra
waterproofing protection.
WALLS: studs to be 2x4-construction grade 16"O.C.- headers to be 2x10 dble.
over all window and door openings.
EXTERIOR FINISH: 4x8x2" hard base nail base built -rite composition
sheathing all corners -rough window openings and rim joist to be covered
with 15 lb. felt. Finished siding to be 7/16"xl2" masonite hard -board
siding set 10" to weather exposure.
INTERIOR FINISH: 32"full thick fiberglass insulation -covered by 4 mill
polysheet vapor barrier -covered by 4x8x2" CDX plywood exterior glue -
spray painted.
CEILINGS: 2x6-16" O.C. -6" fiberglass batt insulation -covered by 4 mill
poly sheet vapor barrier -covered by 4x8x2" CDX plywood exterior glue -spray
painted.
RAFTERS: 2x4-16" O.C. with rid �=aije�sand "Will bracing 4' O.C.-roof sheathing
4x8x2" CDX plywood-16x32 span spec. covered entirely with 15 lb. bldg.
felt paper. All outside or trailing edges of roof to be covered by "T"
style metal edging -covered by 240 lb. asphalt roofing.
ELECTRICAL: 200 Amp service Entrance for interior and exterior lighting -
wiring to conform to State and Local Codes.
PLUMBING: to conform to all Local and State Codes -water to be from Mun-
icip�Ll service -and future plan for toilet facilities to be from Municipal
service -temporary sewer service by commezi.a1 contractor.
HOCKEY RINK: to be of regulation size 90 ft. by 200 ft. as per plat plan
enclosed.
OFF STREET PARKING: to conform to ordinance as per plat plan -present and
future developm6nt.
0
6.-SeR /o'x2v' �
J
A-8
-
�,f,�'
-
ti
�j
I 1
,Roo
,'le'K- -F
.G
`r
f
I
I
D B DATE REVISIONS DATE
CHECKotD BY
APPROVED BY
SCALE:
TITLE IDRAWING NUMBER
O
Gail ff'
�H/II //I ^ /y/re'—
Z�o /3,g rollwol,�l--rA lv
fi 1-514W /vsho�
- .(y000oA
V
i ,a
`.I
i
"K
ry;
Ra Ir"I"es to hB
�" X-77
xl�
1'
ed
i )e8 R/o sA
,Q/DG.46
0= Wc
oisis 0
aXs.-/6o `� IX2 49/1-25?
/.►��t`��P/o/r' iirsXr veic-
1/d''�'1/,CAr/O� X Z 7R /14
�xy tvds0,0-
/x
9 /,o /AI -A
Rx y R19s,c
gylo
,ac/rs.
a/R�qof
\O
�Xzo�
)1670 E aeb-S
Y,,i�JJ�fI.G,F 6� �P�Ilrtr� 1�i311.K
re
,67
DR WN BY DATE REVISIONS DATE
CHECKIED BY
APPROVED BY
SCALE:
TITLE DRAWING NUMBER