Loading...
Plans - 2447 Black Lake Road - 5/28/2021MR. RICHARD SMEDBERG 2447-BLACKLAKE ROAD — 471-9249 24X24-Garage 2X4-STUDS & RAFTERS lE 4X8-5/8" CladwooSi 1"-PLY WOOD ROOF ##15-LB FELT & ##24 W/ROOF BRACING 1 4"-CEMENT FLOo 6X 6X 10 -W I RE 4N.GABLE R, / 1 X 4 BRACE 2X6TI 1 x 6 ROOF BRACING RAFTERS 16" O.C. III III III III III' 2 X 4 DOUBLE TOP PLATE 111 111 li i li 2 X 4 STUDS 16" O.C. \\ \_ i UBLE CORNERS 2 X 4 SINGLE BOTTOM'�KATE 1 X 4 RIDGE BOARD 2 X 4 GABLE DOUBLE 2x 12 OVER HEAD DOOR HEADER WITH 3/e" LAMINATION ,DOUBL-E DOOR STUDS 11, Ii�l t6 , III RONT BOTTOM PLATE _ Poor Quality Document Disclaimer The original or copy of a document or page of a document presented at the time of digital scanning contained within this digital file may be of substandard quality for viewing, printing or faxing needs. Plan Review Comment Sheet Applicant: Scott Suttle Project: New Home Valuation: $300,000 Permit #:11-03B Number of Days Address: 2447 Black Lake Road Date Issued: Municipality: Spring Park Inspector Issued: v Date & Comments 1-31-11 Received Application and Plans. NQ z I -// ;;W&—M &' "0. Cc�,y #1210 ?-.1 - / - / / 1�IlK &- &be/1/ /'lie M t)w-k rz. FOUNDATIONS TABLE R404.1.1(5) CONCRETE FOUNDATION WALLSh.4I.k MINIMUM VERTICAL REINFORCEMENT SIZE AND SPACINGr_ d, a 1,1 Soil classes" and design lateral soil (psf per foot of depth) MAXIMUM MAXIMUM UNBALANCED GW, GP, SW and SP 30 GM, GC, SM, SM-SC and ML 45 SC, ML-CL and Inorganic CL 60 WALL HEIGHT B EIGHT L HEIGHT'b Minimum wall thickness Inches (inches) (feet) (feet) 5.5 7.5 9.5 11.5 5.5 7.5 9.5 11.5 5.5 7.5 9.5 11.5 5 4 PC PC PC PC PC PC PC. PC PC PC PC PC 5 PC PC PC PC PC PC PC PC PC PC PC PC 4 PC PC PC PC PC PC PC. PC PC PC PC PC 6 5 PC PC PC PC PC PCB PC PC #4@35" PCB PC PC 6 PC PC PC PC #5@48" PC PC PC #5@36" PC PC PC 4 PC PC PC PC PC PC PC PC PC PC PC PC 7 5 PC PC PC PC PC PC PC PC #5@47" PC PC PC 6 PC PC PC PC #5@42" PC PC PC #6@43" #5@48" PCB PC 7 #5@46" PC PC PC #6@42" #5@46" PCB PC #6@34" #6@48" PC PC 4 PC PC PC PC PC PC PC PC PC PC PC PC 5 PC PC PC PC #4@38" PCB PC PC #5@43" PC PC PC 8 6 #4@37" PCe PC PC #5@37" PC PC PC #6@37" #5@43" PCB PC 7 #5@40" PC PC PC #6@37" #5@41" PC PC #6@34" #6@43" 1 PC PC 8 #6@43" #5@47" PCB PC #6@34" #6@43" PC PC #6@27" #6@32" #6@44" PC 4 PC PC PC PC PC PC PC PC PC PC PC PC 5 PC PC PC PC #4@35" PCB PC PC #5@40" PC PC- PC 9 6 #4 @ 34" PCB PC PC #6 @48" PC PC PC #6 @ 36" #5 @ 39" PCB PC 7 #5@36" PC PC PC #6@34" #5@37" PC PC #6@33" #6@38" #5@37" PCB 8 #6@38" #5@41" PCB PC #6@33" #6@38" 1 #5@37" PCB #6@24" #7@39" #6@39" #4@48"h 9 #6@34" #6@46" PC PC #6@26" #7@41" #6@41" PC #6@19" #7@31" #7@41" #6@39" 4 PC I PC PC PC PC PC PC PC PC PC PC PC 5 PC I PC PC PC #4@33" PCB PC PC #5@38" PC PC PC 6 #5@48" PCB PC PC #6@45" PC PC PC #6@34" #5@37" PC PC 10 7 #6@47" PC PC PC #6@34" #6@48" PC PC #6@30" #6@35" #6@48" PCB 8 #6@34" #5@38" PC PC #6@30" #7@47" #6@47" PCB #6@22" #7@35" #7@48" #6@45"h 9 #6@34" #6@41" #4@48" PCB #6@23" #7@37" #7@48" #4@48"h DR #6@22" #7@37" #7@47" 10 #6@28" #7@45" #6@45" PC DR #7@3.1" #7040" #6@38" DR #6@22" #7@30" #7@38" For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa; 1 pound per square foot per foot = 0.157 kPa/mm. a. Soil classes are in accordance with the United Soil Classification System. Refer to Table R405.1 b. Unbalanced backfill height is the difference in height of the exterior and interior finish ground levels. Where there is an interior concrete slab, the unbalanced back - fill height shall be measured from the exterior finish ground level to the top of the interior concrete slah c. The size and spacing of vertical reinforcement shown in the table is based on the use of reinforcement with a minimum yield strength of 60,000 psi. Vertical rein- forcement with a minimum yield strength of 40,000 psi or 50,000 psi is permitted, provided the same size bar is used and the spacing shown in the table is reduced by multiplying the spacing by 0.67 or 0.83, respectively. d. Vertical reinforcement, when required, shall be placed nearest the inside face of the wall a distance d from the outside face (soil side) of the wall. The distance d is equal to the wall thickness, t, minus 1.25 inches plus one-half the bar diameter, db (d = t - (1.25 + db/2). The reinforcement shall be placed within a tolerance oft 3/8 inch where d is less than or equal to 8 inches, or t 1/2 inch where d is greater than 8 inches. e. In lieu of the reinforcement shown, smaller reinforcing bar sizes and closer spacings resulting in an equivalent cross -sectional area of reinforcement per linear foot of wall are permitted. f. Concrete cover for reinforcement measured from the inside face of the wall shall not be less than 3/4 inch. Concrete cover for reinforcement measured from the out- side face of the wall shall not be less than I1/2 inches for No. 5 bars and smaller, and not less than 2 inches for larger bars. g. The minimum thickness is permitted to be reduced 2 inches, provided the minimum specified compressive strength of concrete f,, is 4,000 psi. (continued) 94 2007 MINNESOTA STATE RESIDENTIAL CODE FOUNDATIONS TABLE R404.1.1(5)--continued CONCRETE FOUNDATION WALLS°.'.Lk A plain concrete wall with a minimum thickness of 11.5 inches is permitted, provided minimum specified compressive strength of concrete, f is 3,500 psi. Concrete shall have a specified compressive strength of not less than 2,500 psi at 28 days, unless a higher strength is required by note g or h. "DR" means design is required in accordance with ACI 318 or ACI 332. "PC" means plain concrete. Where vertical reinforcement is required, horizontal reinforcement shall be provided in accordance with the requirements of Section R404.4.6.2 for ICF founda- tion walls. M TABLE R404.1.1(6) N CANTILEVERED CONCRETE AND MASONRY FOUNDATION WALLS M MAXIMUM WALL HEIGHTi (feet) MAXIMUM UNBALANCED BACKFILL HEIGHT° (feet) MINIMUM VERTICAL REINFORCEMENT SIZE AND SPACING FOR 8-INCH NOMINAL WALL THICKNESS a °, a a I, I. k Soil Classesd GW, GP, SW and SP GM, GC, SM, SM-SC and ML SC, MH, ML-CL and Inorganic CL 3 None required None required None required 4 4 None required None required No. 4@72 in. o.c. 3 None required None required None required 5 4 No. 4@72 in. o.c. No. 4@56 in. o.c" No. 4@40 in. o.c s 5 No. 4@72 in. o.c. No. 4@56 in. o.c h No. 4@40 in. o.c s N M N M N M N M N M N M N M N M N M N M N a. Mortar shall be Type M or S and masonry shall be laid in running bond. Minimum unit compressive strength is 1,900 psi. M b. Alternative reinforcing bar sizes and spacings having an equivalent cross -sectional area of reinforcement per lineal foot of wall shall be permitted provided the M spacing of the reinforcement does not exceed 72 inches. N c. Vertical reinforcement shall be Grade 60 minimum. The distance from the face of the soil side of the wall to the center of vertical reinforcement shall be no greater N than 2.5 inches. M d. Soil classes are in accordance with the Unified Soil Classification System. Refer to Table R405.1. N e. Interior concrete floor slab -on -grade shall be placed tight to the wall. The exterior grade level shall be 6 inches minimum below the top of wall. Maximum height M from top of slab -on -grade to bottom of floor joists is 10 feet, 0 inches. Unbalanced backfill height is the difference in height of the exterior finish ground levels and M the top of the interior concrete slab -on -grade. N f. Minimum footing size of 20 inches by 8 inches shall be placed on soil with a bearing capacity of 2,000 psf. Minimum concrete compressive strength of footing shall M be 3,000 psi. M g. Provide propped cantilever wall: top of footing shall be 16 inches below the bottom of the concrete floor slab minimum. N h. Provide #5 Grade 60 dowels, I foot, 6 inches long, to connect footing to wall. Embed dowel 5 inches into footing. Place dowels in center of wall thickness spaced at M 32 inches o.c. maximum. No dowels are required where length of the foundation wall between perpendicular walls is two times the foundation wall height or less. M i. This table is applicable where the length of the foundation wall between perpendicular walls is 35 feet or less, or where the length of the foundation laterally sup- N ported on only one end by a perpendicular wall is 17 feet or less. M j. Maximum wall height is measured from top of the foundation wall to the bottom of the interior concrete slab -on -grade. N M k. Install foundation anchorage per Section R403.1.6. N 2007 MINNESOTA STATE RESIDENTIAL CODE 95 vj I( APPWW LOCATION OF I FRONT ELEVATION EXIST'rp &RAPE AT LOCATION OF NEW HOUSE SCALE: V4" = 1'-0" 4 1 -k.,f HOUSE CORNER) x I Read All Attached Matorials! ICITY FILE COPY NJUSt P023t ads" man construction 4 sito v1si, ia, irom road. DRAFTS11"OPPING REQUIRED, CONIC EALE 01 Pp, EWNOT To no so. FT. EVERY PERSON PERFORMING WORK FOR WHICH THE CODE 18 APPLICABLE, SHALL COMPLY WITH THE CODE , THE 'IV Orr GrY 7el 333TIAM L CONTROL EROSION OF BARE SOIL AREAS SO THAT I MOT OCCU 0T SILTATIONDICTES R NT SiSTRr OR NEIGHBORING P30prpTIrS UNTIL LA'I'MS"CAPING AND TURF ESTABLISHMENT ARE COMPLETE. f10 GCCU'71A'UNM/ 0 USE ALLOWED IRML FINAL IMISIFE27"U"I AMWROVAL CALL BUILDUM P20P23M.1 C32-44275M I MS LOT LR' ZE !�j To W-RIT-v PNlV!%MY LINES MU37 02 STI';0 09'3c-R PRUNAOa k"' "r 0K6T0L0TLKZS-!_-'-'_S PDA" H, T'mc.-D iM.UU g0kow, IT 4111 v;. C01S.FTRACTOR MA11, SIV01TAR"T SL41_ 11 -r�,!M­21TIOX III Rli2LA-'T--,O--,'-T "PC LOWZST FLOOR B.11 It: X PRIOR TO COINSITRUCITION. STORM WAT"R RTT"T-07' 1 SMAML BVA CH A N X 1re L il_! 5 i 1 J! 'T () PONDING-L Al-I-E-L 0-1-3. OM13HER SUITATjT1X.,j.'-". ,70 J.,,r,f T 2-rCLjN'_OriF SHALL BE DIRECTED ONTO ADJACMIT PROPMYCM, 3. REVIEWED SUBJECT TO, C 0';'vll P L! A N C, E_ WITH C00j!E S AND F 11 1ELD INSPECTION 17" CONS 1 5 Rv _m,_ , .. nATF-z /_/1 FOR ALL INSPECTIONS CALL 24 HOURS IN ADVANCE AND GIVE PERMIT NUMBERL.:.-), • k&7(f YENr CELL SPRAY POAM INSULATION (KW MIN) 43 BAFFLES MILL WIDTH . .... .. T T Q #F TOM SPACING) MANEW-I.CiNa SBANS EQLTMW,, 12 \—Va' &VP BOARP—" ROOF UNDERLAYMENT R MAYER ONOCOAIa,-Dr�,00,-"jNrioRGLASS w- ATTIC TRIW WALL Falb EMTe17? A-L RIq GATT INSULATION- 124EW 4 MIL POLY VAPOR BARRIER 7- n�rmmnsm OF TM S" SYP BOARD (AIR BARRIER) maw-UORWAMIM r % C, -a7`7 Fsa. . . . . . . . . . . . . \_CI OAED CELL SPRAYro.a.!. W->;at:M/een.j�. �ta& E,-Z=Z ;ZIT FOAM INSULATION AW MIN) 17' rT n S "J. Z;;.: TYPE 'X'6YP BOARD Pp'OVID-1Z Copy OF on ol: IACED %'rYPE'X'ISYP BOARD TRUs- s- LAYOUT cLiPS' w MINIMUM OF I" ANI-11 SPACE REQUIREDFORKiric VENTILATION RIGID WINDWASH - EXTEND WALL SHEATH!NG UP TO I INCH OF ROOF SHEATHING BETIVVEEN ALL RAFTER SPACES. POURED GONG OVER KICK -OUT FU�,S'HM 0 r. C U I R 2 D ATALC 8" PRECAST PLANK :_7Zf"n ONS.J1" 71� x 0 0 MINIMUM REQUIRED ATTIC VENTILATION 10" POURED CONCRETE WALL L pp"OJEC7 AR':]A - 1/22T -0, L _mz SOFFIT. 1/2 TO Fm POURED GONG OVER ROOF NEAR 1:10CE. 4' CLEAN GRANULAR FILL 4' MIN TILE CONCRETE FTS, SEE PLAN FOR 51ZE 4 REINF SECTION @ OARA&E AI SCALE: 1/4" -_ I'_0" U z E0 an -0 —CC aw LL — 0% In 41 @ -j .0 LU 'Rul E LU aft U_ U_ 0 iAt HOUSE CORNER) EXIST'& GRADE AT LOCATION OF NEW HOUSE I0099 �P_% J 4A ASPHALT SHINGLES 15# FELT ICE d WATER BARRIER TO24" FROM INSIDE FACE OF WALL AIR BAFFLES (FULL WIDTH OFF, TRU55 5PACING) 15J2" 055 ROOF 5HEATHING—, DRIP EDGE 2xb SUE BOARD ALUMINUM FA501A VENTED ALUMINUM SOFFIT DRIP EDGI 2xb SUB-F BOARD ALUMINUM ALUMINUM ROOF TRU55 �R44 BLOWN -IN INSULATION " GYPSUM BOARD `—VINYL SIDING O5B EXTERIOR WALL 5HEATHING 2xb STUD WALL Y" 6YP5UM BOARD WALL 5HEATHING EAYE SOFFIT S FASG I A DETA I L 50ALE: %4" = 1'-0.- "`4HALT 5HIN7LES 055 ROOF 5HEATHIN6 OUTRIGGERS 3LE END ROOF TRUSS 055 EXTERIOR .L SHEATHING (L SIDING 7"(F. RAGE SOFFIT � FASCIA DETA I L SCALE: 5/4" = 1'-0" U. im 0 E g %0 4 cp N g {L co ai= N N I V1 L J W N U E �I W U Q 0 Lb V-10" 14' b'-b° 4' 2" 4'-4" ti( 11-4 IT— —2b88 — b'-O' SLIDING DR — (2) 1 a•xgYs•d LVL NOR)- of r / I I FUTURE � BATH I o = Qm $ I P 101 1 I I I - I I WOOD BURNING STOVE I —, --, — - /v- ce; POURED CONCRETEAirl, I FDN WALL Al AD STEEL BEAM ry W I14i' FOIL � � FACE RIGID INSULATION I I o FUTURE I �� _ — — 0 INTERIOR (RIO) MIN REC. ROOM L_ Zo 4'-0" MA F-- Z Z a; I I FLi 8' POURED CONCRETE I X FDN WALL w/�' SLAB LEDGE e 23 II x I ; I'-8"x8"d FTG I W POURED CONCRETE FUTURE I I FDN MALL W W FOIL w/ REINF I I WET BAR I I I FACE RIGID INSULATION I 10' POURED RETE FDN WALL r REFG I I I I I SMOKE 0 INTERIOR (RIG) MIN I L J-- J I'-8"x8"d FTG I DETECTOR ° I a I W REINF -T I II _ a a q'-0. a I ° 3068 I I — (2) I% xll%d LVL(OR)— �. I'-8"x8"d FTG 2 -O" RE' NF TG w/ REINF I II 0 TIONAL OLD b I t 'UP F II 5TOR E FUTLIRE 10" POURED CONCRETE THEATRE RM I ° I I FDN WALL W 2' SLAB ME R JJNEXCAVATED II G RAGE 5IDE II I osiL LLH RGIRDET 8' POURED CONCRETE a I'-8"x8"d FTC I FDN WALL w/ V'a' FOIL llTI L I TY E W,H. FURN. FACE RIGID INSU.ATION oC WREINF 1 AREA 1 A INTERIOR (RIO) MIN d. I 8' POURED CONCRETE FDN WALL w/2' SLAB a 10' POURED NGRETE � I FDN WALL i� ? � FD. I --- O I `-__ -_ LL I ® I'-8'x8"d FTG w w/ REINF 2068 x LEDGE I � � ;... � — ° ,.... ,....... e ° I 3 r I nl approved, corrosive-re6istant nails, Y �P � ►I�tIFRAS H-IMLTtUO B , o BOLTS 1r ON CENTER. .� / X � C r-bxb.d FTG REINF I Al (� y � � �( :o Vw/ bolts, hangers carriage bolts, washer6, nuts, and joist are to be used on all treated lumber. V I 15'-b" T _3„ (3) TRTO 2xI0'S — — — — — — — - j BELL ®BTM -24'b PIER FTG, TYP 10'-4" 1'-10" 2'-4" lb 2'-4- 12'-103/a" I-I'-IYa" (�!j W-O" 30.-0., BASEMENT FLOOR FLAN PROVIDE POSITIVE MECHANICAL CONNECTION 5CALE: i" = 1'-0" Y_ FROM FOOTING TO POST. ,�- BASEMENTS AND EVERY SLEEPING ROOM SHALL HAVE ONE EMERGENCY ESCAPE WNDOW OR DOOR NTH A SILL HEIGHT OF NOT MORE THAN 44" ABOVE FLOOR AND SHALLBE NOT LESS THAN 5.7 SO. FT. Of OPENABLE AREA. NET CLEAR OPENABLE WDTH OF 20" AND HEIGHT OF 24" MINIMUM. SMOKE DETECTORS REQUIRED ON EACH STORY AND IN BASEMENT, LOCATED IN LACE SLEEPING ROOM AND AT A POINT CENTRALLN LOCATED IN THE AREA ACCESSING EACH SLEEPING ROOM AND SHALL BE RUMCONNECTED. LUMBER MUST BE REDWOOD, CEDAR OR TREATED CONCRETE FTG, SEE PLAN FOR 51ZE d REINF FF •MIL ! i CHLORIDE OR . Mt O • i r : LAPPEDAND SEALED JWMODS MUST BE APPROVED BY .!: BUMDING TO APPLICATIOX VAPOR RETARDER REQUIRED BETWEEN CONCRETE FLOOR/SLAB AND SUBGRADE-GARAGES EXCLUDED APPROVED FOUNDATION DRAINAGE SYSTE1Vd RF (R405.1) •� iJ '� I {,r • ALL WATER FROM FOUNDATION DRAINS OR SUMPS MUST BE PUMPED OR DRAINED � DIRECTLY TO THE EXTERIOR THROUGH RIGID PLASTIC OR STEEL PIPING- NO SUMP WATER IS ALLOWED TO BE PUMPED INTO FLOOR DRAINS, SINKS OR ANY OTHER ACCESS TO SANITARY SEWER. O m CRAWL SPACES. INSULATE AND VENTILATE 11150 OF UNDER FLOOR AREA. PROVIDE A MINIMUM 18" x 2e, ACCESS. 'SOLID BLOCKING OR DIAGONAL BRACING _ REQUIRED AT ANCHOR BOLT LOCATIONS IN THE FIRST 3 JOIST OR TRUSS SPACES ON PARALLEL FOUNDATION WALLS, 0 i- PROVIDE COMPLETE FOUNDATION UNDER STEPS MOISTURE BARRIER REQUIRED OVER INSIDE OF FOUNDATION WALL, BEFORE FRAMING AND INSULATION IS INSTALLED. SUMP COVER MUST BE SOLID MATERIAL AND SECURED. PROVIDE CAP BLOCK, FULL WIDTH SILL PLATE OR FILL TOP COURSE SOLID.1/2" ANCHOR BOLTS REQUIRED MIN. 7" EMBEDDED IN MASONRY. MIN. 60/C AND 2 PER PIECE. Mintz's MAXWJM 017 LATE RIM ALL SILL PLATES MUST INSU BE OF REDWOOD -CEDAR 301ST AREA OR TREATED LUMBER. �lI -Ulf; IMA --i. Fj OOST FOOTING 421 DEEP MIMUM CONCRETE -ENCASED ELECTRODE , MAY BE REQUIRED PROVIDE CONNECTION LOCATION P01NT FOR ELECTRICAL CONCRETE -ENCASED ELECTRODE PROVIDE CLEARANCE TO COMBUSTIBLES PER MECH. CODE FOR ALL VENTS(CHIMNEYS CONVEYING COMBUSTION PRODUCTS. 'Aitll uanu,w k7dtts & lI� w,ih AbuI � 2-l-tl � :outside Combustion As ',bFumice Area orThe piewrn Air Duct. MID L�Ab ocpvqL=SrU �� i $?f1 (Rakdon RedLletiOn SYSte {) per MNRC 1322.2103, Ssction 103.6 I Iv1N �C-u rIvL):;)L_ 5CALE: %4" = 1'-0" RIDGE VENT .ASPHALT 5HINGLE5 OVER 15a FELT OVER 15/52" 055 / PGF_FU/ IAIFFRFn/PRFMAAII IF i L,UNuRC I G r I V, SEE PLAN FOR 51ZE 8 REINF V '0 Z o N v v(� 4O 2'� Q � 12 L O �rf t 'O J J W D NU Ln E w a l W O WIL w J R / I / / / I I MAIN FLOOR PLAN 4 50ALE: %" = 1'-0" MAIN LEVEL FINI5HED SWARE FEET : 1,060 sq Ft GARAGE 5WARE FEET = 846 sq ft _ fkJ-1-e CWV�AY4-h6n w,lh 4�baf SMOKE DETECTORS REQUMED ON EACH STORY AND IN BASEMENT, LOCATED IN gACH SLEEPING ROOM AND AT A POINT Y I LOCATED IN THE AREA ACCESSING EACH SLEEPING ROOM AND SHALL BE INTERCONNECTED. CAULKING AND FLASHING AT ALL EXTERIOR OPENINGS I EXTERIOR STAIRWAYS SFlALL BE PROVIDED WITH Aii ARTIFICIAL, LIGHT SOURCE IN 1I12 Da4EDIATE VICINITY OF TEM TOP LANDING OF TIC STAIRWAY EXHAUST FANS MUST BE VENTED TO OUTSIDE AIR. INSULATE DUCT IN UNHEATED SPACES, AA TERIOR STAIRWAYS SHALL BE PROVIDED VaTH AN ARTIFICIAL LIGHT SOURCE IN TI°IE RIBODIATE CO = Carbon Monoxide Detector/Alarm VICINITY OF &4A LANDING OF THE STAIRWAY �= Exhaust Fan I SD =Smoke Detector/Alarm STAIRS: MAXIMUM RISE 7�/4", MINIMUM RUN 10". HANDRAIL REQUIRED I TIC I I WZP • NRM An S SHALLNOT GUARD RAILING I rM yj yUMIN. HEIGHT ��:D 4" MAX, SPACING I 4 RISERS OR MORE IN RESIDENTIAL STAIRS REQUIRES A HANDRAIL. HANDRAILS SHALL BE EVERY STAIRWAY SHALL HAVE A PLACED 34 INCHES MINIMUM OR 38 INCHES HEADROOM CLEARANCE OF NOT LESS MAXIMUM � HEIGHT ABOVE T HFE ISO SING OF THE THAN 6 FEET 8 INCHES. TREADS AND SHALL BE COIN'Tii`y 'OUS THE FULL LENGTH OF THE STAIRIS WITH EACH END RE T U R N E D TO THE V ALL. UM zO^ N N y � N � Now p N z Ln J 3^ w N �^ U Y Ln >_ °> o L U O F--------- — — — — — — I I ED&E OF WALL / BELOW I I I 0 "v I I 1 I I I I �ED&E OF WALL BELOW UPPER FLOOR PLAN %a" A5 SCALE: = 1'-0" UPPER LEVEL FINISHED SQUARE FEET = 1532 eq It 5/1.2 PITCH r e- PITCH I I --------- -- Provide 22" x 300 Attic Access i x I x 1 m � I Q 1 I i I i EXHAUST FANS MUST BE VENTED TO OUTSIDE AIR. INSULATE DUCT IN UNHEATED SPACES. E ENTS AND EMY GLEEPINO R HAVE ONE EMERGENCY ESCAPE WINDOW OR R WITH A SILL HEIGHT OF NOT MORE THAN 44" ABOVE FLOOR AND SHALL BE NOT LESS THAN 5.7 SQ. FT. OF OPENABLE AREA. NET CLEAR OPENABLE WIDTH OF 20" AND HEIGHT OF 24" MINIMUM. Carbon Monoxide Detectors are required within 10 feet of each room lawfully used for sleeping purposes CAULKING AND FLASHING AT ALL EXTERIOR OPENINGS I I I I I I I 6" I I I I I I I I - -I I I I I I I I I I I I I I I I I I I I I I I I SMOKE DETECTORS REQUIRED ON EACH STORY AND IN BASEMENT, LOCATED IN EACH SLEEPING ROOM AND AT A POLNT CENTRALLY LOCATED IN THE AREA ACCESSING EACH SLEEPLI`IG ROOME �AND SHALL B IN 11sRCOliNEC11'+1J. CO = Carbon Monoxide Detector/Alarm O= Exhaust Fan SD = Smoke Detector/Alarm ail v���rk�l l�ea�s lc� --------- —F--------------------------- ]! I 5 112 PITCH I PITCH PITCH I PITCH 2 ROOF PLAN A5 5CALE: %e" = 1'-0" 1 R I I1❑ I 1 PITCHED ROOF A5 REQ'D I CHIMNEY I I 8/12 _ I PITCH i 8/12 8/12 _ r -o PITCH PITCH L -0 —1. rmi LJ Im O E x N �p N X "S �WP Q f IL 0 .' � L LW O L J W NUS Ln E C J LU Q Ll- Ll- W O / / / / / / / 1 _ / SO' REAR SETBACK FROM OHM 10'-0' SIDE BLD6 SETBACK SIDE BLDG SETBACK °ro• PROPOSED DOUSE EXIST'G DETACHED 6ARAGE / FT I I ADJACENT OUS E , MIST'S DECK PROPOSED EXISTISA)TILITY POI TO BE RELOCATED LOT SQUARE FEET :12'183A5 sq Ft 30% OF LOT ■ 3834.910 sq Ft PROPOSED HOUSE i 6ARASE SQUARE FEET =2064 sq It COVERED STOOP ■ 128 sq Ft TOTAL HOUSE SQUARE FEET (INCLJJDIN& COVERED STOOP)C 2212 sq it SIDEWALK ■ 20g57 sq Ft DRIVEWAY ■ 850.03 sq Ft FROP05ED 51 TE PLAN SCALE: Is" : 1'-0" I m � I 7FRMTACK AVERAGE BETMEEN TWO ADJAGE T BUILDINGS) � I I I I I I _ I I I ADJAGENT GARAGE IT UM z 0 u N d xrk ZO p 'O E teC�tl C" L N 0 1A L 1.re.4 %0 J ■� W N u sae Ln E 00 O� J U O di TOTAL IWERVIOIUS SQUARE FOOTAGE ■ SrIhO sq It /:.