Permits - Permit# SP-2021-00011 - 4750 West Arm Road - 3/15/2021O
City of Spring Park Permit
1 ci rr OF
r "PA R K
To Schedule an Inspection Call: 952-442-7520
Details
Permit Number: SP-2021-00011
Issue Date: 3/15/2021
Zoning Type: RESIDENTIAL
Use Type: IRC-3
24 HOUR NOTICE REQUIRED FOR ALL INSPECTIONS ♦ MON-FRI: 8AM-4:3013M * NO HOLIDAYS
Site Address: 4750 WEST ARM ROAD, SP, MN 55384
Description:
Remodeling upstairs bed/baths, non load bearing partition walls, alterations. All new fixtures8inishes
Permit Granted To: Massey Berg, LLC
Homeowner's Name: PATRICIA ADAIR TIMBERG
Phone Number:
Parcel #: 1811723330013
Fees (4)
Permit Type: BLDG - Remodel, Small Residential
Permit Exp: 8/24/2021
Valuation: $47,000.00
Receipt A
Product
Sale Date
Quantity
Date Paid
Status
Pmt Info
Amount
11769
License Lookup
2/25/2021
1.00
3/15/2021
Paid
Check: 051
$5.00
11769
State Surcharge
2/25/2021
1.00
3/15/2021
Paid
Check: 051
$23.50
11769
—Permit Fee
2/25/2021
1.00
3/15/2021
Paid
Check: 051
$791.25
11769
Plan Review Fee
2/25/2021
1.00
3/15/2021
Paid
Check: 051
$514.31
Total: $1,334.06
Notes
• This permit is issued in accordance with and subject to all provisions of Ordinances and policies governing building and zoning in City of
Spring Park.
• Permit Holder/Contractor/Owners Agent is responsible to call for the inspections!
• Permit Packet, including approved plan, and this inspection record must be posted in an accessible location before calling for inspection.
Maintain this inspection record until work is complete.
• No deviations from the approved plans are allowed without prior consent from the building inspections department.
• To Owner, Occupant, or Contractor: It is ILLEGAL TO OCCUPY this area/building until all required final inspections have been made,
approved, signed, and certificate of occupancy issued!
ME /
Scott Qualle, Building Official
City of Spring Park +4349 Warren Avenue ♦ 55384 Copyright 02021
INSPECTION RECORD
2020 MN State Building Code �� U
City of Spring Park Permit Number: SP-2021-00011 Issue Date: 3/15/2021
SITE ADDRESS: 4750 WEST ARM ROAD, SP, MN 55384 Description:
PERMIT TYPE: BLDG - Remodel, Small Residential Remodeling upstairs bed/baths. non load bearing partition walls. alterations.
ZONE/USE TYPE: RESIDENTIAL IRC-3 All new fixtures/finishes
APPLICANT: Massey Berg, LLC
OWNER: PATRICIA ADAIR TIMBERG
No inspection will be performed, and a re -inspection fee will be charged, if this "Inspection Record", the "City of Spring Park Permit", and, when applicable, the
approved plans are not available to the inspector. This permit expires if construction activity does not commence within 180 days from obtaining this permit; when
construction activity has been suspended or abandoned for at least 180 days; or the work has not been inspected within 180 days from the last documented activity.
IF SEPARATE PERMITS ARE REQUIRED, REFER TO THE "SEPARATE PERMITS REQUIRED FOR:" STAMP ON YOUR APPROVED
PLANS/CONSTRUCTION DOCUMENTS TO IDENTIFY WHAT SEPARATE PERMITS ARE REQUIRED.
ALL REQUIRED ROUGH -IN INSPECTIONS, NOTED ON SEPARATE PERMITS, MUST BE COMPLETED PRIOR TO SCHEDULING A FRAMING
INSPECTION.
ALL REQUIRED FINAL INSPECTIONS, NOTED ON SEPARATE PERMITS, MUST BE COMPLETED PRIOR TO SCHEDULING A BUILDING FINAL
INSPECTION.
DO NOT COVER ITEMS TO BE INSPECTED.
Permit Card (4)
Framing
Required
Wallboard (Fire -Rated Assemblies)
Required
Insulation
Required
Final
Required
MUST CALL TO SCHEDULE NO LATER THAN THE BUSINESS DAY PRIOR TO THE INSPECTION DAY: 8:00 A.M. TO 4:30 P.M. MONDAY THRU
FRIDAY. PHONE NUMBER TO CALL: 9S2-442-7520
When a Certificate of Occupancy is needed, return this card and the approved final inspection notice to
the City of Spring Park office.
CITY OF SPRING PARK
PAGE 1 BUILDING PERMIT
4349 Warren Avenue SP-2021-00011
Spring Park, MN 55384 O H'nIMK QMM
Rouled to MNSPECT
Phone: 952-471-9051 Fax 952-471-9160 El Load Handout ok*n
SITE ADDRESS: 41va ? ( T PtiD`
O was the home txxnseructed before 1978? (YES a, continue with One 2. McKgontinue vithout eomplsoM EPA section)
2) Wtii the work dbAxb k$ aq ft of interior pairllbd sur(sces or 22A sq ft of axtarlor palled surfsoss? (yu o•go b kw 4. NO o tins 3)
.
8) Ara two any wkdowa being npa:od7 (YES a, go to One 4. NO a Continue wOtqut compleWg EPA Section)
4) Has this home been Certified Lead Free? (YES a, you MUST Attach Certllloodon Irrbnnetion. NOpecompleb line 5)
EPA OonAecior Certlllcation Number NAT - T_-Z G' 2Z E) ` (oppose to contractor only)
PROPERTY OWNER: P68,]✓�k Address - . lrp �-
i Emati: jJ a ei i C b
Contact Name: Phone: Z 2 (nY 2,
CONTRACTOR a S e &_LjAddress 4 2-L o d e
S4_ Stab: /J o Phone: -7 fd
ContrIRSIM L.kmm Ift R TS-0 { Contact Name• ( v s
Emma: V*-, L5 S w. ,t. 6 b "
ARCHITECT: a4a V f
Address:
stote Phone' Foc
Email: Contact Name' Phone:
OF WORK: o New Con@&ucdon a Dad o Re -Root
0 Commercial Residsnds1 a CherlDe of Use a Pod n Ra
EST. VALUAT OF WORK a Fim nkh Beseent a Retaining Wall o Fans
!s: I)� J_ a Porch a Shed
Square feet a Addition o Derno lim o WindowlDoor Rrrpleoemwit
In GomQo4ftohe&Dstach a PlumbhlQ- *M6 dear on Pop 2 d being replaced
DstaRed per d Work o Struc4ae a ddm1*nPep2 a Misc Otw
a1t,eV-A_1(,-,Yxe,U
uvwkn d ft apore•- aaI , u wa ewnarb npwnrn., is eiquyad and aWwnar fr ZanMp MN�Yraear «dr jaw nd •r suN�
or dnWw to ~ Wm>tw popdy to po kme awdad ynpadbna. Oft my M w wd pw swift I hrabp mn wad tlr, approadm and dM@ #a ar efaaadlon Y bua and
wind b fwbut d Ily biaa/adra Mery epee f W d w«k performed vA b in aooadanoa VAh aPpv+ad pbm apadlio�e�• wd cmdrfwr rd b.61d.0y d «dYrnow dM Yuriagar
and ti bwe dM SYIa d Mnluda npra�p Man Wan p rmmd to rd1 pamiL 1 ww to Pw an pan wrbw has wan If I dm" eat to pepN wrh Se wdc Panai aipYM ohm wade
•
nd mwarwW MM 1a0 days ion dab d pamR «rook jsauipndad abandorw O. «not tiPWW br 100 dsw WO* Myad •w soopa d m pma «w«k Mho. a er
M u6jed b a ponailr Pall °
Noise Ordhmmm In Effect Y - Y Before 7 a m. and~ 10 PAL Waabnd•Mordaya before 7 a.m. and alter a pwl.
WNATURE OF APPLICANT• DATE: 2/ r 7 'LA
PRINTED NAME••p�,/1 a This Is the d: Or o Ownerls Rep dallys
OCCUP. TYPE: I RC-3 CONST. TYPE: I CODE: 2U2UMKU BLDG SPRINKLED Yes / No
vALUAnoN: s 47,000
Permit Fee: i 791.25 WAC CNwp: i
Plan Review Fes: i 514.31 Sewer & Water Hook -Up: i
State Surcharge: i 23.50 Sewer & Waller Disconnect i
Site Inspection Fes: i Water Meter. i
S.E.C. Fee: i Muni SEANA Fee: $
Investipatlon Fee / Other Fee: S *2016 SAC Escrow.. S2.485
Copy Chefgs ($25 Per 8.5 xi peps) i Other i
License Check (is) / Load chock (is) S 5.00 TOTAL DUE: S
SUB -TOTAL. -TOTAL.# 1334.06
Plumbing Fee (from Pogo 2) $ •No>�: r:amlaew �r.e. w fw wlbnda.d a ola Ir.e comer wlaree..l+us sV=
row tic aManalarla. eww■ PWPN tea be nqulmd odes rlarere M ba " a
Mechanical Feb Pa 2 i
oar Yd Connor rahl.ar m SAC r eataradrwd, ewes, wN he nAelded In M.
Special CorididwaRaciuked Sefbadw
Building Approval BY AlfDATE: 02/24/2021
Printed BuikiMg Ap0qVal By Kastern O License vertiicalion O Lead Vedfcation - Checked W.
Chy Approval By
PATE:
Paid: Dab: /5—a Recelpt No. C4(KO D S BY
OF
::::: e�'z
SPRING PARK
On Lake 94innetonka
February 24, 2021
Permit Number: SP-2021-00011
Project Name: Massey Berg LLC
2224 Goodrich Ave
St. Paul, MN 55105
Scope: Residential Code Review of remodel in the second floor of a multi -home building located
at 4750 West Arm Rd.
Inspections: All work shall be inspected. It is the responsibility of the contractor/installer to contact the
Department of Building Safety, when ready to schedule an inspection, at (952) 442-7520
between the hours of 8:00 a.m. and 4:30 p.m., Monday through Friday.
The plans and specifications for the project named above have been reviewed for substantial compliance
with the current Minnesota State Building Code. The review is limited to the submitted scope of work
and is based upon the supposition that the data on which the design is based are correct, and that the
necessary legal authority has been obtained to construct the project. The responsibility for the design of
structural features must be taken by the project designer. Any changes from the submitted plans and
specifications shall be reviewed and approved by the Department of Building Safety.
Approval is based on the correction of all noted deficiencies and compliance with all applicable
items listed below.
The following information is related to the submitted plans/scope as general information and/or code
compliance requirements. Compliance with the stated requirements shall be verified during the
construction process. Any changes to the plan and any required additional information shall be provided
to this agency for code -compliance review and approval, prior to its installation.
General Information:
1. Applicable Codes:
a. 2020 MN Residential Code (MRC) (2018 IBC as amended)
b. 2020 MN Special Provisions (MSP)
c. 2015 MN Energy Code (MREC) (2012 IECC as amended)
d. 2020 MN Mechanical Code (MMC) (2018 IMC as amended)
e. 2020 MN Fuel Gas Code (MFGC) (2018 IFGC as amended)
f. 2015 MN State Plumbing Code (MPC) (2012 UPC as amended)
g. 2020 MN Electrical Code (MEC) (NFPA 70)
2. Separate permits are required for:
a. Electrical
b. Mechanical
c. Plumbing
3. The field inspector may identify additional code compliance requirements.
identified code compliance requirements shall be completed.
Any additional
Specific Code Items to Be Addressed During Construction:
1. Required clearance of 24-inches in front of the toilet to the shower is not met. Adjust fixtures
accordingly.
2. Safety glazing is required on bathroom windows.
3. Ventilation is required in the bathrooms.
4. See approved plan and items listed below.
The below items are commonly missed items that require correction following inspections.
These are provided for your benefit and may or may not apply specifically to your project.
MN Residential Code:
1. Bathrooms, water closets compartments, and other similar rooms shall be provided with
aggregate glazing area in windows of not less than 3 square feet, one-half of which must be
openable. (MRC R303.3)
a. Exception: The glazed area shall not be required where artificial light and a local exhaust
system are provided. The minimum local exhaust rates shall be determined in accordance
with Section M1507. Exhaust air from the space shall be exhausted directly to the
outdoors.
2. Habitable space, hallways, bathrooms, toilet rooms, laundry rooms, and portions of basements
containing these spaces shall have a ceiling height of not less than 7 feet. The required height
shall be measured from the finished floor to the lowest projection from the ceiling. (MRC R305.1)
a. Exception: Bathrooms shall have a minimum ceiling height of 6 feet 8 inches at the center
of the front clearance area for water closets, bidets, or sinks. The ceiling height above
fixtures shall be such that the fixture is capable of being used for its intended purpose. A
shower or tub equipped with a shower head shall have a minimum ceiling height of 6 feet
8 inches above a minimum area 30 inches by 30 inches at the showerhead.
3. Bathtub and shower floors and walls above bathtubs with installed shower heads and in shower
compartments shall be finished with a nonabsorbent surface. Such wall surfaces shall extend to
a height of not less than 6 feet above the floor. (MRC R307.2)
4. Glazing in walls, enclosures or fences containing or facing hot tubs, spas, whirlpools, saunas,
steam rooms, bathtubs, showers, and indoor or outdoor swimming pools where the bottom
exposed edge if the glazing is less than 60 inches measured vertically above any standing or
walking surface shall be considered a hazardous location. This shall apply to single glazing and
all panes in multiple glazing.
a. Exception: Glazing more than 60 inches measured horizontally and in a straight line, from
the waters edge of the bathtub, or whirlpool, or from the edge of a shower.
5. Smoke alarms shall be installed in the following locations: (MRC R314.3)
a. In each sleeping room.
b. Outside each separate sleeping area in the immediate vicinity of the bedrooms.
c. On each additional story of the dwelling, including basements and habitable attics but not
including crawl spaces and uninhabitable attics. In dwellings or dwelling units with split
levels and without an intervening door between the adjacent levels, a smoke alarm
installed on the upper level shall suffice for the adjacent lower level provided that the lower
level is less than one full story below the upper level.
6. Carbon monoxide alarms shall be installed outside and not more than 10 feet (3048 mm) from
each separate sleeping area or bedroom. Alarms shall be installed on each level containing
sleeping areas or bedrooms. (MRC R315.1.1)
7. Buildings shall have approved address numbers, building numbers or approved building
identification placed in a position that is plainly legible and visible from the street or road fronting
the property. These numbers shall contrast with their background. Address numbers shall be
Arabic numbers or alphabetical letters. Numbers shall be a minimum of 4 inches high with a
minimum stroke width of 1/2 inch. (MRC R319.1)
MN Energy Code:
1. All exhaust, supply, and return air ducts and plenums shall be insulation according to Table
R403.2.1. (MREC R403.2.1)
a. Insulation is only required in the conditioned space for a distance of 3 feet from the exterior
or unconditioned space.
b. V means the vapor retarder in accordance with IMC Section 604.11
c. W means an approved weatherproof barrier.
TABLE R403.2.1 MINIMUM REQUIRED DUCT AND PLENUM INSULATION
Duct Type/Location
Duct Type/Location
Exterior of building
R-8 V and W
Attics, garages, and ventilated
crawls aces
R-8 and V
Exhaust ducts within conditioned
Ispaces
R3.3 and V
2. Ducts, air handlers, and filter boxes shall be sealed. (MREC R403.2.2)
3. Building framing cavities shall not be used as ducts or plenums. (MREC R403.2.3)
4. Insulation for hot water pipe with a minimum thermal resistance (R-value) of R-3 shall be applied
to the following:
a. Piping larger than 1/4-inch nominal diameter.
b. Piping from the water heater to kitchen outlets.
c. Piping located outside the conditioned space.
d. Piping from the water heater to a distribution manifold.
e. Piping located under a floor slab.
f. Buried piping.
g. Supply and return piping in recirculation systems other than demand recirculation
systems.
h. Piping with run lengths greater than the maximum run lengths for the nominal pipe
diameter given in Table R403.4.2.
All remaining piping shall be insulated to at least R-3 or meet the run length requirements of Table
R403.4.2.
Mechanical Code Items:
1. Mechanical ventilation requires a minimum exhaust rate of 50 cfm in toilet rooms and bathrooms.
(MMC 403.2.1)
2. The air removed by every mechanical exhaust system shall be discharged outdoors at a point
where it will not cause a nuisance and not less than the distances specified in IMC Section
501.3.1. The air shall be discharged to a location from which it cannot again be readily drawn in
by a ventilating system. Air shall not be exhausted into an attic or crawl space and the exhaust
system shall be equipped with a backdraft damper at the point of discharge. (MMC 501.3)
3. The termination points of exhaust outlets and ducts discharging to the outdoors shall be located
with the following minimum distances: (MMC 501.3.1)
i. For all environmental air exhaust: 3 feet from property lines; 3 feet from operable openings
into buildings, and 10 feet from mechanical air intakes.
4. Ducts shall be supported at intervals not to exceed 12 feet. Flexible and other factory -made ducts
shall be supported in accordance with the manufacturer's instructions. (MMC 603.10)
Plumbing Code Items:
1. Fixtures shall be set level and in proper alignment with the reference to adjacent walls. No water
closet or bidet shall be set closer than 15 inches from its center to a side wall or obstruction nor
closer than 30 inches center to center to a similar fixture. The clear space in front of a water
closet or bidet shall not be less than 24 inches. (MPC 402.5)
2. Water closets shall have an average consumption not to exceed 1.6 gallons of water per flush.
(MPC 403.2)
3. Shower heads shall have a maximum flow rate of not more than 2.5 gpm at 80 psi. (MPC 408.2)
4. Shower and tub -shower controls shall be of the pressure balance, thermostatic, or combination
pressure balance/thermostatic mixing type that provides scald and thermal shock protection in
accordance with ASSE 1016 or ASME A112.18.1/CSA B125.1. Handle valves shall be adjusted
to deliver a maximum mixed water temperature of 120°F. (MPC 408.3)
5. Shower compartments, regardless of shape, shall have a minimum finished interior of 1024
square inches and shall also be capable of encompassing a 30 inch circle. (MPC 408.6)
If you have any questions or concerns regarding this plan review please contact me via telephone at
952-442-7520 or email at codereview(a)_mnspect.com.
Regards,
Nicole Xastern, R.A., NCARB
Plan Reviewer
MNSPECT, LLC
Helping You Comply With The Code
235 First St. W.
Waconia, MN 55367
O: 952-442-7520
F: 952-442-7521
www.mnsi)ect.com
Thank you for your Payment!
Transaction ID: 11769
Transaction Number:
Transaction Type: Payment
Recipient: Contractor
Notes:
Fees (4)
1LIIYUt
P R I 1\1 cj 'f'\ R 'K
City of Spring Park
4349 Warren Avenue
SP MN, 55384
Ph: 952- 42-7520
$1,334.06
Date: 3/15/2021
Method: Check: 051
Address: 4750 WEST ARM ROAD, SP, MN 55384
Reference: Permit Number: SP-2021-00011 Type: BLDG - Remodel, Small
Residential for Massey Berg, LLC
State Surcharge
Paid
1.00
$23.50
Plan Review Fee
Paid
1.00
$514.31
License Lookup
Paid
1.00
$5.00
—Permit Fee
Paid
1.00
$791.25
$23.50
$514.31
$5.00
$791.25
Total Amount: $1,334.06
Page 1 of 1 Printed on: 3/15/2021
Read all attached materials.
Everyone performing work to
which the code is applicable shall
comply with the code.
The field copy of these plans must be kept
on -site and made available to inspector during
all inspections.
To schedule inspections call
(952) 442-7520
Please have the permit number and street
address ready at the time of the call.
Electrical
All electrical must be approved by State
Electrical Inspector.
For electrical permit inquiries please contact
the Department of Labor & Industry
WWW.ELECTRICITY.STATE.MN.US
(651) 284-5064
A minimum of R-3 insulation shall be applied to
hot water pipe in accordance with the following;
* Piping larger than 3/4" nominal diameter.
Piping from the hot water heater to kitchen
outlets.
* Piping located outside of conditioned space.
* Piping from the hot water heater to a
distribution manifold.
* Piping under a floor slab and any buried
piping.
* Supply and return piping in hot water
circulation systems.
* Piping exceeding the maximum lengths given
in table R403.4.2.
The maximum hot water temperature at Bathtubs and
Whirlpool tub fillers not to exceed 120 degrees
Fahrenheit, installation of limiting device meeting ASSE
1070 or CSA B125.3 is required.
Anti -scald and thermal shock protection device required
at shower and tub -shower control valves meeting ASSE
1016 or ASME A112.18/CSA B125.1.
Hand -Held showers require back -flow prevention.
Internal back -flow prevention devices to comply with
ASME A112.18.1/CSA B125.1 or have an external
back -flow prevention device complying with ASME
All 2.18.3 installed at final inspection.
Existing ceiling, wall, or floor cavities exposed during
construction are required to be filled with insulation.
Hardwired and interconnected smoke alarms are
required in the following locations:
•1 (one) in every bedroom
•1 (one) in the area outside every bedroom
-At least 1 (one) per floor where no bedrooms exist
including basements and habitable attics
Existing spaces where no electrical work has taken place
may have battery operated smoke alarms that are not
interconnected.
1 (one) Carbon Monoxide (CO) alarm is required
outside of and within 10-feet of every bedroom or
sleeping area. A CO alarm is required on every level
that contains a bedroom or sleeping area.
CO alarms may be hardwired, plugged into an outlet or
battery operated.
All required alarms must be installed and operational
at time of final building inspection.
Reviewed for Code Compliance
This review is limited to the submitted scope of work, is based upon the supposition that the plan
accurately depicts the intended construction and end -use, that the necessary legal authority has
been obtained to construct the project and work is subject to code compliance and field
inspection during construction.
By: nkasfern Type of Construction: Remodel
Date: 2/24/2021 Occupancy Classification: IRC-1
Permit #: SP-2021-00011 Code Edition: 2020 MRC
Separate Permits
Required For:
,T Electrical
/T Mechanical
Plumbing
Fireplace
Demolition
Fire Suppression System
Septic
Existing condition from
permit SP-2021-00005
24" clear in front of toilet required.
Center of toilet must be 15" away on
from a wall or obstruction on both
sides. MN Plumbing Code 4714
New and Existing windows
required to have safety glazing
2q'
— 6-2 1 /2" 4'-T 10'-9 1 /2"
T— — — — — — — — — — — — — — — — —1
I �
5'-11"
I
i
10--0 1 /2"
e
L
0
206
I O I
I CO MqK n
I MOK
Bathroom
bN MOK Ventilation
Required
cv I 11'-5"
I
q'-3 3/4"
I
I I
I I
I I
I I �
I I
I
I—F-1 -4--
------------------L---------------
T-q 1/4" T-2 3/4" 12-2"
2q'-2"
LIVING AREA
618 SG FT
Minimum ceiling height for alterations to existing
bathrooms shall be no less than 6'-4", including
beams, girders, ducts, or other obstruction.
Fire rating must be
maintained between
units. All penetrations
and repairs must be fire
caulked, patched, or
corrected.
Double walls between
townhouses shall be
separated by (2) 1-hr
fire resistance rated
walls.
Common walls
separating townhouses
shall have 2-hr fire
resistance rating and
without plumbing or
mechanical (R302.2.2)
Bathroom plumbing fixtures
shall be installed in accordance
with MN rules, Chpt 4714, MN
Plumbing Code
Bathtub and shower floors, and
walls above bathtubs with installed
shower heads and in shower
compartments shall be finished
with a nonabsorbent surface to a
height of 6 feet above the floor.
LICENSE/CERTIFICATE/REGISTRATION DETAIL
RESIDENTIAL
Class Type: BLDG Number: BC750127
CONTRACTOR
Application 429150
No:
Expire Date: 3/31/2022
Orig Date: 12/31 /2018
Enforcement NO
Action:
Workplace N/A
Experience:
Status: ISSUED
Effect 4/1 /2020
Date:
Print 4/20/2020
Date:
Name: MASSEY BERG LLC
Address: 4119 30TH AVE S
MINNEAPOLIS , MN 55406
Phone: 763-670-9445
Business Relationship Requirements
Name: MASSEY, QB749842 iView
DAVID G Lic/Reg No: license/registration]
Status: EXPIRED Application 429582
No:
Expire 12/18/2020 Effect 12/18/2018
Date: Date:
Orig 12/18/2018
Date:
Another Lookup?