Loading...
Permits - Permit# SP-2020-00072 - 2478 Black Lake Road - 1/1/2020L. City of Spring Park Permit CITY pi. P trk I \N Cl FV lik -1) To Schedule an Inspection Call: 952-442-7520 Details Permit Number: SP-2020-00072 Issue Date: 8/31/2020 Zoning Type: RESIDENTIAL Use Type: 24 HOUR NOTICE REQUIRED FOR ALL INSPECTIONS • MON-FRI: 8AM-4:30PM ♦ NO HOLIDAYS Site Address: 2478 BLACK LAKE ROAD, SP, MN 55384 Description: 12 x 14.5 Deck with glass railing Permit Granted To: Homeowners Name: AMIN & LUCILLE EMAD Permit Type: BLDG -Deck Permit Exp: 2/23/2021 Phone Number. Parcel #: 1911723120021 Valuation: $4,500.00 Fees 0 State Surcharge 8/24/2020 1.00 Due $2.25 0 —Permit Fee 8/24/2020 1.00 Due $155.75 0 Plan Review Fee 8/24/2020 1.00 Due $101.24 Total: $259.24 Notes • This permit is issued in accordance with and subject to all provisions of Ordinances and policies governing building and zoning in City of Spring Park. • Permit Holder/Contractor/Owners Agent is responsible to call for the inspections! • Permit Packet, including approved plan, and this inspection record must be posted in an accessible location before calling for inspection. Maintain this inspection record until work is complete. • No deviations from the approved plans are allowed without prior consent from the building inspections department. • To Owner, Occupant, or Contractor. It is ILLEGAL TO OCCUPY this area/building until all required final inspections have been made, approved, signed, and certificate of occupancy issued! Scott Qualle, Building Official City of Spring Paris #4349 Warren Avenue ♦ 55384 Copyright 02020 Poor Quality Document Disclaimer The original or copy of a document or page of a document presented at the time of digital scanning contained within this digital file may be of substandard quality for viewing, printing or faxing needs. CITY OF SPRING PARK PAGE 1 BUILDING PERMIT 4349 Warren Avenue SP-2020-00072 Spring Park, MN 55384 )(Handout Ginn IPECT Phone: 952�71-9051 Fax: 952-471-9160 ❑mad Handout Given Routed ,,, Pic:- I' Was tits hr me constructed before 19787 (YES o; continue with pne 2, NO Koontirwi wmwut oompleUhg EPA Section), I. -Will the vxA-Qhrturb:;8, aq It of Interior painted surfaces or k2o aq it of exti"'Onhtbd WIDOW? (YttlSm go to tine 4; NO o time 3) Are there any wtndb* being1roplaoed2 (YES a, go w line 4. NO c continue Wttltout kwrnpletlrtg EPA Section) I f fas this lu ms;been CertiNdIL64d Frey? (y0c, YW:MUST Attach Certtf{cetlon !n(omteydn. NO.a complete line I f�PA �otl�et011ftafw(i tAikfrtrbir• tNAi;A- �Itas fO ooalra� og)i_oii�j,, ROPERT.YrQtftii ER-f, e Ai#A—.A .%U' ` 11, ✓ 7 7 ���r ��t2esdefmitat .• s?K►AN-kof wDR`� awar.a.r. we+�e pWop•rly m psWfens WWeed.dte" amd m a h•u a my u�•. I a.nw age• tltr � id ttm t•as dOr Efati c►ttiasaota act" odd sae Cosa WM4 d wW1b IW dry• nm• lbestAlwbol NJ Noise mdmrai Eflae IONDAY cement �"r`�t . O+FYfIC9�___ o *4 snsoatq.asner. w ib aarr, nwwedathr•. b Wqut•d eWw •ulbart;•• ttm inrip AmWdnttibaior «cinema and tlm eWeap asy. �r �r�w,�wa pWtx Wtoan. l nr.ey •ea,ow,eo. Rrt m Iw• t•ad tMa apple•son aWWe Mate tfrt ■ ldetmrbn r tnm end •+� �bc.,wn,w,e,,.avwn..v.CIe�.Im..,aoaal+.�..,eee�larn+o�esM«aa�.wte.rsr pfp•reit 1 ear•• to pry aaytao teldatll fats Mr If lehoosa net m proud w� om wadi DrN •optima sfw►wcA r4 _ ae•rba+•d. «not mWrp•crd 1br do aaye. worUctWryaWd em atop• of etla p•rre0. «wark wawa • psrnu «►,apeet� - NODIY 80t0ra 7 am. and after 10 pm. WeelwndsllioGt{els before 7 s.fs. end aiDer a p.ta. y I �- . TM� �! •a��:atr�w%`ram �L ,.�� __ _^_. _.� —, �.. _ _�,s:._rs.,. . Y PE: Permit Fee: s 155.75 Plan Review Fee: $ 101.24 State Surcharge: s 2.25 Site Inspection Fee: 5 S.E-C. Fee: $ Investigation Fee / Other Fee: S Copy Charge (525 per 8.5 xi 1 page) $ Lk*rm Check ($5)1 Lead Check ($5) $ SUB -TOTAL s 259.24 Plumbing Fee (from Page 2) $ Mecharticel Fee (from Page 2) $ pedal ConditlonalRequired Setbacks: Dr Y-oikWeA a )rA�o1(hUr r.Jlr1.��4 Building Approval By: Printed Building App al dy, City Approval By. Paid: I _0�r ®J Date: Yes / No WAC Charge. S Sewer & Water Hook -Up: $ Sewer & Water Disconnect: $ Water Meter. $ Muni SEIWA Fee: $ —� '2018 SAC Easrovr. PLO Other_ _ V TOTAL Dt1E: 570. a 'NOTE: Convnerdai pb m win be sWbtnnmd Im ud t.oma En Aro for aI1C daltrminatkm Escrow Osptrm, win ntqubsd when penM b loriad. if tdbr Mat cow" nvlew no am is win be nfW- 0 In fuL y DATE 08/26/2020 licole Kastern ❑ LMense Verification 11 Lead Verification - Checked B DATE: T,?Il Receipt Na 35102 By-. Thank you for your Payment! Transaction ID: 9600 Transaction Number. Transaction Type: Payment Recipient: homeowner Notes: CITPY OF 4 ic \_.JrR W tAINNISOT A City of Spring Park 4349 Warren Avenue SP MN,55384 Ph:952-442-7520 $259.24 Date: 8/31 /2020 Method: Check: 3562 Address: 2478 BLACK LAKE ROAD, SP, MN 55384 Reference: Permit Number: SP-2020-00072 Type: BLDG - Deck for AMIN & LUCILLE EMAD Fees ProductQuantity: State Surcharge Paid 1.00 $2.25 $0.00 $2.25 Plan Review Fee Paid 1.00 $101.24 $0.00 $101.24 —Permit Fee Paid 1.00 $155.75 $0.00 $155.75 --------_-_---- -----� ---_ --_-- —`--- Total Amount: $259.24 '-- Page 1 of 1 Printed on: 8/31/2020 INSPECTION RECORD 2020 MN State Building Code City of Spring Park Permit Number: SP-2020-00072 Issue Date: 8/31/2020 SITE ADDRESS: 2478 BLACK LAKE ROAD, SP, MN 55384 Deskrialion: PERMIT TYPE: BLDG - Deck 12 a 14.5 Deck with Wass railing ZONE/USE TYPE: RESIDENTIAL APPLICANT: AMIN & LUCILLE EMAD OWNER: AMIN 8: LUCILLE EMAD No inspection will be performed, and a re -inspection fee will be charged, if this "Inspection Record", the "City of Spring Park Permit', and, when applicable, the approved plans are not available to the inspector. This permit expires if construction activity does not commence within 180 days from obtaining this permit; when construction activity has been suspended or abandoned for at least 180 days; or the work has not been inspected within 180 days from the last documented activity. IF SEPARATE PERMITS ARE REQUIRED, REFER TO THE "SEPARATE PERMITS REQUIRED FOR:" STAMP ON YOUR APPROVED PLANS/CONSTRUCTION DOCUMENTS TO IDENTIFY WHAT SEPARATE PERMITS ARE REQUIRED. ALL REQUIRED ROUGH -IN INSPECTIONS, NOTED ON SEPARATE PERMITS, MUST BE COMPLETED PRIOR TO SCHEDULING A FRAMING INSPECTION. ALL REQUIRED FINAL INSPECTIONS, NOTED ON SEPARATE PERMITS, MUST BE COMPLETED PRIOR TO SCHEDULING A BUILDING FINAL INSPECTION. DO NOT COVER ITEMS TO BE INSPECTED. Permit Card Footing Required Framing Required Final Required MUST CALL TO SCHEDULE NO LATER THAN THE BUSINESS DAY PRIOR TO THE INSPECTION DAY: 8:00 A.M. TO 4:30 P.M. MONDAY THRU FRIDAY. PHONE NUMBER TO CALL: 952-442-7520 When a Certificate of Occupancy Is needed, return this card and the approved final Inspection notice to the City of Spring Park office. 41a. �paa�c� PAnP7 On Lake Minnetonka August 26, 2020 Permit Number: SP-2020-00072 Project Name: Emad Amin 2478 Black Lake Rd Spring Park, MN 55384 Scope: Residential Code Review of a new deck for a single-family home. Inspections: All work shall be inspected. It is the responsibility of the contractor/installer to contact the Department of Building Safety, when ready to schedule an inspection, at (952) 442-7520 between the hours of 8:00 a.m. and 4:30 p.m.. Mondav throuoh Friday The plans and specifications for the project named above have been reviewed for substantial compliance with the current Minnesota State Building Code. The review is limited to the submitted scope of work and is based upon the supposition that the data on which the design is based are correct, and that the necessary legal authority has been obtained to construct the project. The responsibility for the design of structural features must be taken by the project designer. Any changes from the submitted plans and specifications shall be reviewed and approved by the Department of Building Safety. Approval is based on the correction of all noted deficiencies and compliance with all applicable items listed below. The following information is related to the submitted plans/scope as general information and/or code compliance requirements. Compliance with the stated requirements shall be verified during the construction process. Any changes to the plan and any required additional information shall be provided to this agency for code -compliance review and approval, prior to its installation. General Information: 1. Applicable Codes: a. 2020 MN Residential Code (MRC) (2012 IBC as amended) b. 2020 MN Special Provisions (MSP) c. 2015 MN Energy Code (MREC) (2012 IECC as amended) d. 2020 MN Mechanical Code (MMC) (2012 IMC as amended) e. 2020 MN Fuel Gas Code (MFGC) (2012 IFGC as amended) f. 2015 MN State Plumbing Code (MPC) (2012 UPC as amended) g. 2017 MN Electrical Code (MEC) (NFPA 70) 2. Separate permits are required for: a. Electrical 3. The field inspector may identify additional code compliance requirements identified code compliance requirements shall be completed. Specific Code Items to Be Addressed During Construction: 1. See approved plan and items listed below. Any additional City of Spring Park 4349 Warren Avenue, Spring Park, NIN 55384 Phone: (952) 471-9051 / Fax: (952) 471-9160 / Web: www.ci.spring-park.mmus The below items are commonly missed items that require correction following inspections. These are provided for your benefit and may or may not apply specifically to your project. MN Residential Code: 1. Approved corrosion -resistant flashing shall be applied shingle -fashion in such a manner as to prevent entry of water into the wall cavity or penetration of water to the building structural. -framing components. Self -adhered membranes used as flashing shall comply with AAMA 711 and fluid applied flashings shall comply with AAMA 714. The flashing shall extend to the surface of the exterior wall finish. Approved corrosion -resistant flashing shall be installed at all of the following locations: (MRC R703.4) a. Continuously above all projecting ledger boards. b. Where exterior porches, decks, or stairs attach to a wall or floor assembly of wood -frame construction. 2. Exterior stairways shall be provided with an artificial light source located in the immediate vicinity of the top landing of the stairway. Exterior stairways providing access to a basement from the outdoor grade level shall be provided with an artificial light source located at the bottom of the landing or stairway. (MRC 303.8) 3. There shall be a landing or floor on each side of each exterior door. The width of each landing shall not be less than the door served. Every landing shall have a minimum dimension of 36 inches measured in the direction of travel. Exterior landings shall be permitted to have a slope not to exceed 1/4 unit vertical in 12 units horizontal (2-percent). (MRC R311.3) 4. Exterior landings, decks, balconies, stairs and similar facilities shall be positively anchored to the primary structure to resist both vertical and lateral forces or be designed to be self-supporting. Attachment shall not be accomplished by use of toenails or nails subject to withdrawal. (MRC R311.5) 5. Stairways shall not be less than 36 inches in clear width at all points above the permitted hand- rail height and below the required headroom height. Handrails shall not project more than 4.5 inches on either side of the stairway and the minimum clear width of the stairway at and below the handrail height, including treads and landings, shall not be less than 31-1/2 inches where a handrail is installed on one side and 27 inches where handrails are provided on both sides. (MRC R311.7.1.2) 6. A flight of stairs shall not have a vertical rise larger than 151 inches between floor levels or landings. (MRC R311.7.3) 7. Handrails shall be provided on at least one side of each continuous run of treads or flight with four or more risers. Handrails to comply with MRC R311.7.8 for mounting height, continuity and grip - size. (MRC R311.7.8) 8. Handrail height, measured vertically from the sloped plane adjoining the tread nosing, or finish surface of ramp slope, shall be not less than 34 inches and not more than 38 inches. (MRC R311.7.8.1) 9. Handrails adjacent to a wall shall have a space of not less than 1-1/2 inch between the wall and the handrails. (MRC R311.7.8.3) 10. Handrails for stairways shall be continuous for the full length of the flight, from a point directly above the top riser of the flight to a point directly above the lowest riser of the flight. Handrail ends shall be returned or shall terminate in newel posts or safety terminals. (MRC R311.7.8.4) 11. The maximum riser height shall be 7-3/4 inches. The riser shall be measured vertically between leading edges of the adjacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest by more than 3/8 inch. Risers shall be vertical or sloped from the underside of the nosing of the tread above at an angle not more than 30 degrees from the vertical. Open risers are permitted provided that the opening between treads on risers located more than 30" above the floor do not permit the passage of a 4-inch-diameter sphere. (MRC R311.7.5.1) 12. The minimum tread depth shall be 10 inches. The tread depth shall be measured horizontally between the vertical planes of the foremost projection of adjacent treads and at a right angle to the tread's leading edge. The greatest tread depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch. (MRC R311.7.5.2) 13. Guards shall be located along the open sides of floors, stairs, ramps, and landings that are located more than 30 inches measured vertically to the floor or grade below. Insect screening shall not be considered as a guard. (MRC R312.1.1) 14. Required guards at open -sided walking surfaces, including stairs, porches, balconies or landings, shall be not less than 36 inches high measured vertically above the adjacent walking surface, adjacent fixed seating or the line connecting the. leading edges of the treads. (MRC R312.1.2) Exceptions: a. Guards on the open sides of stairs shall have a height not less than 34 inches measured vertically from a line connecting the leading edges of the treads. b. Where the top of the guard also serves as a handrail on the open sides of stairs, the top of the guard shall not be less than 34 inches and not more than 38 inches measured vertically from a line connecting the leading edges of the treads. 15. Required guards shall not have openings from the walking surface to the required guard height which allow passage of a sphere 4 inches in diameter. (MRC R312.1.3) Exceptions: a. The triangular openings at the open side of stair, formed by the riser, tread and bottom rail of a guard, shall not allow passage of a sphere 6 inches in diameter. b. Guards on the open side of stairs shall not have openings which allow passage of a sphere 43/8 inches in diameter. 16. Plastic composite exterior guards shall comply with the requirements of Section R317.4. (MRC R312.1.4) 17. The ends of beams shall have not less than 1-1/2 inches of bearing on wood or metal and not less than 3 inches of bearing on concrete or masonry for the entire width of the beam. Where multiple -span beams bear on intermediate posts, each ply must have full bearing on the post in accordance with Figures R507.5.1(1) and R507.5.1(2). (MRC R507.5.1) 18. Deck beams shall be attached to supports in a manner capable of transferring vertical loads and resisting horizontal displacement. Deck beam connections to wood posts shall be in accordance with Figures R507.5.1(1) and R507.5.1(2). Manufactured post -to -beam connectors shall be sized for the post and beam sizes. Bolts shall have washers under the head and nut. (MRC R507.5.2) 19. The ends of joists shall have not less than 1-1/2 inches of bearing on wood or metal and not less than 3 inches of bearing on concrete or masonry over its entire width. Joists bearing on top of a multiple -ply beam or ledger shall be fastened in accordance with Table R602.3(1). Joists bearing on top of a single -ply beam or ledger shall be attached by a mechanical connector. Joist framing into the side of a beam or ledger board shall be supported by approved joist hangers. (MRC R507.6.1) 20. Joist ends and bearing locations shall be provided with lateral resistance to prevent rotation. Where lateral restraint is provided by joist hangers or blocking between joists, their depth shall equal not less than 60 percent of the joist depth. Where lateral restraint is provided by rim joists, they shall be secured to the end of each joist with no fewer than three 10d (3-inch by 0.128-inch) (76 mm by 3.3 mm) nails or three No. 1 Ox 3-inch long wood screws. (MRC R507.6.2) 21. Deck ledgers shall be a minimum 2-inch by 8-inch nominal, pressure -preservative -treated Southern pine, incised pressure -preservative -treated hem -fir, or approved, naturally durable, No. 2 grade or better lumber. Deck ledgers shall not support concentrated loads from beams or girders. Deck ledgers shall not be supported on stone or masonry veneer. (MRC R507.9.1.1) 22. Band joists supporting a ledger shall be a minimum 2-inch-nominal, solid -sawn, spruce -pine -fir or better lumber or a minimum 1-inch by 9-1/2-inch (25 mm x 241 mm) dimensional, Douglas fir or better, laminated veneer lumber. Band joists shall bear fully on the primary structure capable of supporting all required loads. (MRC R507.9.1.2) 23. Fasteners used in deck ledger connections in accordance with Table R507.9.1.3(1) shall be hot - dipped galvanized or stainless steel and shall be installed in accordance with Table R507.9.1.3(2) and Figures R507.9.1.3(1) and R507.9.1.3(2). (MRC R507.9.1.3) 24. Alternate framing configurations supporting a ledger constructed to meet the load requirements of Section R301.5 shall be permitted. (MRC R507.9.1.4) 25. Lateral loads shall be transferred to the ground or to a structure capable of transmitting them to the ground. Where the lateral load connection is provided in accordance with Figure R507.9.2(1), hold-down tension devices shall be installed in not less than two locations per deck, within 24 inches of each end of the deck. Each device shall have an allowable stress design capacity of not less than 1,500 pounds. Where the lateral load connections are provided in accordance with Figure R507.9.2(2), the hold-down tension devices shall be installed in not less than four locations per. deck, and each device shall have an allowable stress design capacity of not less than 750 pounds. (MRC R507.9.2) 26. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Numbers shall be a minimum of 4 inches high with a minimum stroke width of 1/2 inch. Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. (MRC R319.1) MN Special Provisions: 1. Minimum footing depth in zone I is 42 inches. (MRC 1303.1600 Subp. 1) If you have any questions or concerns regarding this plan review please contact me via telephone at 952- 442-7520 or email at codereview(a)mnspect.com. Regards, Nicole Xasfern, R.A., NCARB Plan Reviewer MNSPECT, LLC Helping You Comply With The Code 235 First St. W. Waconia, MN 55367 O: 952-442-7520 F: 952-442-7521 www.mnsi)ect.com TABLE R507.9.1.3(1) DECK LEDGER CONNECTION TO BAND JOIST' (Deck live load = 40 psf, deck dead load =10 psi JOIST SPAN CONNECTION DETAILS 6' and less I 6'1" to 8' I 84" to 1o' I 10'1" to 12' I 12'1" to 14' 14'1" to 16' 164" to 18' On -center spacing of fasteners '/z inch diameter lag screw with '/z inch maximum sheathing', ` 30 23 18 15 13 11 10 '/Z inch diameter bolt with '/Z inch maximum sheathing` 36 36 34 29 24 21 19 '/Z inch diameter bolt with 1-inch maximum 36 36 29 24 21 18 16 sheathing For SI: I inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kpa. a. Ledgers shall be flashed in accordance with Section R703A to prevent water from contacting the house band joist. b. The tip of the lag screw shall fully extend beyond the inside face of the band joist. c. Sheathing shall be wood structural panel or solid sawn lumber. d. Sheathing shall be permitted to be wood structural panel, gypsum board, fiberboard, lumber, or foam sheathing. Up to '/= inch thickness of stacked washers shall be permitted to substitute for up to V. inch of allowable sheathing thickness where combined with wood structural panel or lumber sheathing. TABLE R507.9.1.3(2 PLACEMENT OF LAG SCREWS AND BOLTS IN DECK LEDGERS AND BAND JOISTS MINIMUM END AND EDGE DISTANCES AND SPACING BETWEEN ROWS TOP EDGE BOTTOM EDGE ENDS ROW SPACING L,cdgee 2 inches" % Inch 2 inches' 1 5/, inches° Band Joist` r/, inch 2 inches 2 inches' 15/s inches' For SI: 1 inch = 25.4 mm. a. Lag screws or bolts shall be staggered from the top to the bottom along the horizontal run of the deck ledger in accordance with Figure R507.9.1.3(1). b. Maximum 5 inches. c. For engineered rim joists, the manufacturer's recommendations shall govern. d. The minimum distance from bottom row of lag screws or bolts to the top edge of the ledger shall be in accordance with Figure R507.9.1.3(1). STAGGER FASTENERS IN 2 ROWS Q 0 0 5.5' MIN. FOR 2 X 8' 5- 6.5' MIN. FOR 2 X 10 O O O O 0 7.5' MIN. FOR 2 X 12 2' MIN. LEDGER LAG SCREW OR BOLT 3/4' MIN. For SI: 1 inch = 25.4 mm. FIGURE R507.9.1.3(1) PLACEMENT OF LAG SCREWS AND BOLTS IN LEDGERS 'DISTANCE SHALL BE PERMITTED TO BE REDUCED TO 4.5' IF LAG SCREWS ARE USED OR BOLT SPACING IS REDUCED TO THAT OF LAG SCREWS TO ATTACH 2 X 8 LEDGERS TO 2 X 8 BAND JOISTS. EXTERIOR SHEATHING EXISTING STUD WALL EXISTING 2x BAND JOIST OR ENGINEERED RIM BOARD 2" MIN. 1 s/s" MIN. 5" MAX. 2" MIN. FLOOR FRAMING O Ooo . 000.o ..o o. p Z o . EXISTING .. , o C2 0 FOUNDATION WALL For SI: 1 inch = 25.4 mm. For SI: 1 inch = 25.4 mm. DECK JOIST LAG SCREWS OR BOLTS JOIST HANGER FIGURE R507.9.1.3(2) PLACEMENT OF LAG SCREWS AND BOLTS IN BAND JOISTS FIGURE R507.9.2(1) DECK ATTACHMENT FOR LATERAL LOADS SHEATHING NOTE: SIDING THIS DETAIL IS APPLICABLE WHERE FLOOR JOISTS ARE FLASHING FOR PARALLEL TO DECK JOISTS. WATER TIGHTNESS 2" MIN. DECKING JOIST HANGERS 2x LEDGER WITH FASTENERS IN ACCORDANCE WITH TABLE R507.2 -4- HOLD-DOWN DEVICE MIN 750 LB_ CAPACITY FLOOR JOISTS AT 4 LOCATIONS, EVENLY DISTRIBUTED ALONG DECK AND ONE WITHIN 24' OF EACH END OF THE LEDGER. HOLD-DOWN DEVICES SHALL FULLY ENGAGE DECK JOIST PER HOLD-DOWN MANUFACTURER. For SI: I inch = 25.4 mm, I foot = 304.8 mm. A FULLY THREADED '/e' DIAMETER LAG SCREW PREDRILLED W/ MIN. W PENETRATION TO CENTER OF TOP PLATE, STUDS, OR HEADER. FIGURE R507.8.2(2) DECK ATTACHMENT FOR LATERAL LOADS .• all attached Everyone performing work to which the code is applicable shall comply with the code. The field copy of these plans must be kept on -site and made available to inspector during all inspections. To schedule inspections call (952) 442-7520 Please have the permit number and street address ready at the time of the call. Electrical All electrical must be approved by local Electrical Inspector. For electrical permit inquiries please contact the City of Mound Electrical Inspector. Dave Hucky (952) 442-7520 Plan Revisions All construction shall comply with the approved plans. Plan revisions will not be reviewed in the field without prior approval from the Building Official. Submit all plan revisions to the Department of Building Safety for review, prior to their construction. BEFORE YOU DIG Contact Gopher State One Call to locate buried utilities. 651-454-0002, 800-252-1166, www.gopherstateonecall.org In accordance with Minnesota law, you must wait 48 hours (excluding weekends and holidays) after you,ve submitted your dig information to begin your digging project. Reviewed for Code Compliance This review is limited to the submitted scope of work, is based upon the supposition that the plan accurately depicts the intended construction and end -use, that the necessary legal authority has been obtained to construct the project and work is subject to code compliance and field inspection during construction. By: n%sfern Type of Construction: DECK Date: 8/26/2020 Occupancy Classification: IRC-1 Permit #: SP-2020-00072 Code Edition: 2020 MN Residential Code Deck Ledger shall be positively bolted to structure following the requirements of Table R507.9.1.3(1) and Table R507.9.1.3(2). All fasteners shall be hot dipped galvanized or stainless steel and shall be installed in accordance with Figures R507.9.1.3(1) and R507.9.1.3(2). Install corrosion resistance flashing above all ledgers and seal sides and bottom with approved sealants. If using alternate fasteners provide manufacturer's specifications to inspector at time of framing inspection. Lateral Load Connectors Required When installing in accordance with Figure R507.9.2(1) install not less than two (2) within 24" of each end of the deck. When installing in accordance with Figure R507.9.2(2) install not less than four (4) devices with a minimum load rating of 750lbs each. N g on top of a multi -ply beam shall beaccordance with Table R602.3(1).g on top of a single -ply beam orbe attached by mechanical connector. Composite decking often has reduced span ratings, especially when used as stair treads. Maximum spans of composite decking shall not exceed spans specified in manufacturers installation instructions. Instructions to be available on -site at final inspection. All columns resting on footings require lateral restraint by means of mechanical connections or 12" embedment in concrete or surrounding soils See Figure R507.4.1 Deck Joist shall be provided with lateral restraint at bearing points. Where restraint is provided with hangers or blocking their depth shall be minimum 60% of the joist. If secured by a rim board it shall be attached with a minimum 3-10d (3" x0.128" nails) or three No. 10x3" wood screws. When adding additional load to an existing footing, each footing must be uncovered for inspection to determine if the base size and depth are of minimum size to carry all supported loads and provide frost protection minimum depth. Uncover existing footings and call for inspection prior to constructing structure above. SUPPLEMENT to Deck Permit Application (MUST be Included when applying for permit) The following information is required to be included with a Deck permit application. 1. Footing Diameter. 1 I Depth: / :t 2. Size of posts: 3. Size of beams: S x 1 3 3 Number of plys: 4. Cantilever on beams: l 2ev" i 5. Size of joists: 2 l2 Spacing: 6. Cantilever on joists: 2!!(MI Hogue 3 7. Species of lumber (please check one): ❑ Sou ❑ Spruce Pine Fir ❑ Hemlock Fir ❑ Douglas Fir iz' 8.. Dimensions of floor boards: If using composite decking ma 9. Height of deck from 10. Height of guardrail: 11. Spacing of 12. Heiah(o00 idicate the manufacturer. 1 Jd **4 fiance to property lines (also identify on site plan): Side 1: b. Side 2: c. Rear. d. Other. iderosa Pine ❑ Unknown Page 3 of 3 Revised May-2016 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Deck Ledger shall be positively bolted to structure following the requirements of Table R507.9.1.3(1) and Table R507.9.1.3(2). All fasteners shall be hot dipped galvanized or stainless steel and shall be installed in accordance with Figures R507.9.1.3(1) and R507.9.1.3(2). Install corrosion resistance flashing above all ledgers and seal sides and bottom with approved sealants. If using alternate fasteners provide manufacturer's specifications to inspector at time of framing inspection. 200 LEDGER BOARD FLASHED AND BOLTED TO HOUSE RIM To meet minimum footing HOUSE size from Table R507.3.1 bell base of footing to (16" 0) W x (6") Thick, 42" deep. 4 . li Joists: 2x10 @ 16" o.c. ' Beams: (2) 2x10 Posts: 6"x6" 1' DECIONG TO BE 2 X 6 CEAAR RAIL SYSTEM TO IIEET O1C REQUIREMENTS FOR 2016 t 4' O.C. PICKETS HOUSE —14'-6'- Lateral Load Connectors Required When installing in accordance with Figure R507.9.2(1) install not less than two (2) within 24" of each end of the deck. When installing in accordance with Figure R507.9.2(2) install not less than four (4) devices with a minimum load rating of 750lbs each. I KAM$ ARE 5-1/r x 13-3le 2a—i.6E SYP PReSSURE 'SATED TITAN TIMBER GWLAMI DECK WM LEDOErtt Is FLASHED AND LAG BOLTED AT HOusE LATERAL BRACING PRONDm BY SIMPSON smoxo TIE OTTIZ TWD (2) 5/16' x 4' GRK RSS STRUCTURAL SCREWS 16' O.C. R502.2.1 JOIST HANKERS ARE SIZED AND NAMED AS REQUIRED POS75 ARE SM PRESSURE TREATED AGO .60 RET. JOB NAME: EMAD AMIN 0 200 JOISTS INSTALLED 16' O.C. TEMPERED GLASS RAILINGS ON DECK Foundation Jt jor Deck When adding additional load to an existing footing, each footing must be uncovered for inspection to determine if the base size and depth are of minimum size to carry all supported loads and provide frost protection minimum depth. Uncover existing footings and call for inspection prior to constructing structure above. FOOTINGS EXTEND "" THROUGH CONCRETE PATIO N 5-1/4' x 13-3/4' 24F-1.6E SYP PRESSURE TREATED TITAN TIMBER GLULAM DECK BEAM ADDRESS: 2478 BLACK LAKE RD SPRING PARK MN I DRAWN BY: MIKE RUDH DATE: 4-17-20 O16' Diameter . Footing FROST ► 07 NO TO BE 4Y DEEP. 16' DIAMETER BURIED POST TO BE Sx6 .60 RET PRESSURE TREATED WOOD n -' • _ ,"�!�' � � � } I Al � _'�r +7t ; F fit. i �- t� 1 ,) ! rr •, y n z :�t - Uzi = r rr? }i. z>sN - c 38'„HIGH GUARD ,RAIL • file: tl t� '� sI d Iif i'���.'I 4 � '%a t... P:,t.f�.14� 8�:+nc�x�.++:c. ;. ,ry .1...... , 7;/ + .( .-j ".�Iu'i•.,"I r 1 F 1 .. it 4EL.J' T- if' ." 9 .}. 4j ' Fllr �j mrr•,r ., ft R,,iYk�' 1 r+ �C ., S'�-"�r �S a,• )j 1 ; 1 �� ��.i�'y Si' A}1 � yW,1 _ 5-1/47 x 13-3/4' 24F-1.BE'. SYP PRESSURE TREATED TITAN TIMBER GLULAM DECK BEAM AUowablo PvtouWt'lon Preaeure 1:500 pef DeaVn Load 65 !be%q ft for Deck an ;,+ , �, •1 i, 9 « :,i . ':8x8',SUPPORT .POST t , ., E ,, Y „ � 3 Ir ,� ti2�a� j i'" 0•)If ]� �� ,!• i Y - ti�l 41 1 1 �+ i,, �, _ 1+'1 ? i V ry +r Ic1�t r :sri ` r I- h b 1, Ir t ? F r r p° �. l _ ' y r tit I� d• t � J 4 , E• 9 Y In i7" { l � hA�i `�' 1 w .1 � r - � w .! [� , Ifi 1 ,, r i J Pr'1 E'F 'UF �r'y'1'.t L• Stin+- ..-w r?'-:- 1 LFOOTING EXTENDS THROUGH CONCRETE PATI ,1 V I rl 1 1 41 ' DECIGNW7O�BV 2 X7n` "XpARi:� ti.s 16 DIAMETER ' 3 a s`: "• 42' DEEP RAIL'S TO MEE••1 tC REQUIREMENTS rs' 2018 r<N'.- O C. Pip(F JOISTS ARE'2X1O PRFy JRE 1REATED 18' O t I`'' CONCRETE FOOTING v s BEAMS ARE'S-1/4 �s' S=3%4T 24F 1 8E ySYr' .1tESS11RE'TREAIED, T 1i TIM .1 LULAY OE"2 BEAN LEOG6R IS FLASHEDsif LAG BOLTFD�AT HO BRACWC i t5)V10EO BY19A1P90N $;`R iLATL7tAL 11nE,GT112', .+ 74iJ NE 1Wo (2) 8/18r x 4„% , S�RSSSiRUCTUW4L�5 :1N5116'<OC RSOti2.°• , ` JOIST HAN EPS`� ; yM NAILED AS FL. `4JIRED L $AND egsis AriE 6XS �; l RE ' iiEn1ED� AjC* 6� ?1 T ,� JOB EM A, D AM I IV � .'NAME: J... ... ' ADDRESS::2478 BLA,CK',LAK'E RD SPRING PARK MN DRAWN BY: MIKE - RUDH'El k r`' DATE: 4-17-20 FROST FOOTINGS TO BE 42' DEEP, 16' DIAMETER BURIED POST TO BE 6x6 .60 RET PRESSURE TREATED WOOD Allowable Foundation 71 1 r I pressure 3C HIGH rGUARD RAIL � Deafen Load 66 1bs for Deck Y� (iy;�` t# '' + J-r-•j�"{fit $ �1'. i K lr. x7/ o V V d, 12' t � _ lf4fk? ff I ; i h l •. (tad .��'�� ,� .-r •� Y � �"�1 ;• 2x10 LEDGER BOARD FLASHED AND BOLTED �.e(, I^�y�,�,���tTa� C t��i{r��`II,tN�;r•'1� rah,,'' TO HOUSE RIM �� M t�rr ,z �I ,4r•++` �i7 It, � �i'�; ,,f+ tia ,� c �•��. ;� !r ,' , ;�ti�1'��tt� �y t�` a''�J�kr"�r {Ja] ,, +�"t � �•� „�Cr` � al'.: '1j '�s�l, ,: 7( �'i. �1i F �F- ja•K7+ L)'f ,,+'�� + in� ~ 2 + � � � d ti `; � {+`' ' S� � �tf "t rS•�i�l`%t }y c�j � � ri �t� �1r't�li i - rJ-1�4 X 13-3/4" t�� �24F-1.BE SYP' °;{�� �? thtt;u+''ti`i,�: t '�71'vtl ��F;: < PRESSURE TREATED TITAN TIM ER ,GLULAM..DECK BEAM Wx - , i�h 44. �9 a ��,Yti r �41 { F ig .. };+ } �t�rF ^' ys 41T', �1 y Vit 3 F 3 f 6x6%SUPPORT' POST ( i n• i Y r •CNv r t71L%rt t cYr , � + � Y+ 5 't� +� •M ) 1' , i ' J : .. fi I� '1.fie I �� + lvt' L' �'rr"'y, �.+{`5'L' �'-•' �s<y n .- {w ,i.�rot �, `d r, + - •, y. �' s �t . �s � � �iyJa r IlttiJ � tt. ,r. A " l�i� rC S' FI'1 C 3,+�, ! h` ti .fdr t .r, t t• r7r. .. A.. �' i r t t �, °.�Y�rl �. ; i G + , * , :``"i D ' t t ,.� .x%£ +°� • FOOTING EXTENDS :Sta, Xt !�, 1'r +� :,rnn h>', i ;i , f i •� b1 _� r'',,, a E�ij` �"t a,dL�- THR_ WGM'CONCRETE PAMn ��, ✓� ' 4 '� "r.:•'+ f 4 � % 16' DIAMETER 42' DEEP CONCRETE FOOTING - r RNL SY97Dr Xo YRSr utC f$fttlf@ iOR;if�014-a:.'. RIg1�18 � r, h JQ81S ARE'ZX10 P�lii'�`TREATED�IB''CFO. �' � >l ' {I r 864fS a.?/4'' x 13+b/1'• 'j/F 1.8q 81IP P(t S TWA1R� TITAN . ULAl1 DECK t 1 g ; LEOQEit IS. F�A6FffD. AND L0 SOLTiD'AT < 1. .r.-!TUBE.L�IIERAL:8RAf9fQ PROVI�BD BY (BMPSON STR�.TI�;OTnZ �` ' ' TWO (�) 6/t6;:x 4� OfH( RSSr9TBUC1yRA1, SORT: 1�! 0"Q R30Z.y.1 /e J016T HAfAQ=cAREtlaW AN9 NALEP.'AS REOUii� ` hOSTS /►RE; B%A;PRESSIlR�;TI ATED`AOQ .eo,ise�r . JOB NAME' EMAD AMIN ADDRESS: 2478 BLACK LAKE RD SPRING P • r fit: DRAWN BY: MIKE RUDH DATE: 4-17-20 77 1 - O16" Ok mater Footing MN FROST FOOTIN= TO Gg 42" DEEP, If a DMZW BURIED POST TO B& 6xf1 .60 RET PARE TREATED WOOD 200 LEDGER BOARD FLASHED AND BOLTED TO HOUSE RIM HOUSE -14'-6'- 1 I 15 `" M ^ 2x10 JOISTS HOUSE a, INSTALLED 16' O.C. I TEMPERED GLA 1• RAILINGS ON DE K FOOTINGS EXTEND THROUGH CONCRETE PATIO 5-1/4' x 13-3/4' 24F-1.8E SYP PRESSURE TREATED TITAN TIMBER GLULAM DECK BEAM 0 DE =NO TO BE 2 X 6 CEQAR RAIL SYSTEM TO MEET IRO REQUIREMENTS FOR 201Q C 4' O.C. PICKETS JOISTS ARE 2X10 PRESSURg TREATED 16' O.C. H1AM9 ARE 5-1/4' x 13.4/4' Z4F-I.SE SYP PRRINIURE TREATED TITAN AMBER OLULAM DECK DfAM LOW IS FLASHED AND W BOLTED AT HOUSE !ATERAL BR�ACUIG PROVIAED BY $IMPSON STRO" TIE DMZ 11MO (2) 5/16' x 4' GM IM STRUCTURAL SCREW" 16' O.C. Rb02.2.1 JOIST MANGERS ARE SIZED AND NAILED AS REQUII= POSTS ARE 6X6 PRESSURQ MA70 AM .60 RET, JOB NAME: EMAD AMIN ADDRESS: 2478 BLACK LAKE RD SPRING PARK MN DRAWN BY: MIKE RUDH DATE: 4-17-20 AUowctblq Foundation Pressure 1.500 psf Daa1Dn 4oad 66 ttw/aq Jt for Dock O16' Dian etr Footing FROST FOOTINGS TO BE 4Y DEEP. 18' DIAMFIFA BURIED POST TO BE 6x6 .60 RET PFAWURE TREATED WOOD a m r (been to accommodate point to the site Set into the site 1 be maintained / of sediments ected shell be x9Nb n9 accordance with INSTALL ROCK Iv /-,8/�1J� used storm sewer CONSIRmnav • r j� 81 001. ENTRAN6i PIER NOIU `.`f 94se f .-INSTALL 52T t be installed in a iv , ft ' RNL�/8/O NU ginner that FENCrIW I L - ,�.I.s � � �� � r \ � �. PRCPO M ` ' , RETAWNG WALL vawx�� '"J placed to prevent wAiER 1 -. ,,�•��,A��T' ay L e9 s to remain in •.9ns t Q 9.a7 x tent of V `� X f - 9IdCJf� eith spray mulch. tin A �. , , , '��g�BI�ZL�3r6. s7C debris. Thcsc ,` i7s \1 r �: d�' onto adjaeeut W`p{8 a• ytypti� � 7b: v. ' Mmaesota 9. 'T T B.TQ.)r em- ardaas wears r '�ti 949 I o as a / 94a.9 1 �8 p as solid waste. x �vdt / -S �o�o: 949.7 938 aD events and t /: sass a4 'D J o e _._ �, tQ 4 tag been deposited � S /'/.' � m 9 H�. ...�/t�0 477.9 _•Lure bra exiting the site94 • • p ` '' 7.7 �tN u be property ��_ DWELLING : '--SJ7.7fw 7 discharge shallt!Y \ . 10. 075b can wW filter the Witter, w a, as SIXEMlr(£) REUNM WALL e site is Lrst - -- %A It gf�1hr a�i�ffieDI with spray mulch. AR�� ute"mimmum The RETAIWALL 9ne97.2 :'-5=40WM t additional silt &lSilhi i !:�93'7 �$ 1OL ' saa II AxlObw - —stab ` .ii Amolw azsaedw) odso-asbunt" 'steex - � w1. $ � was properly done , � = p xmpleted lAT�.OTw./ 9315X • r rp/ controldenea mrALL $T 4 d ea needed to y PRl>POSm t1EVAT10NS fEHLF,/�OROLL Sr from p"mposed . FlRST FLOOR' (SUB FLOOR) 949.30 jlj 1 e"O') TOFTOUNDATION 847 44MENT FLOOR 938 74 sue'4(A66�nkd �- 9>a eto t Milt PROPosEp HARDCOVER° sQke Ouse„ 21260 Sq Ft utuf" Deck 174 Sq Ft ��-1 ront:Welk 146'Sq` Ft ; riverrey r 540, q Ft STORMV/ATER1NANAGEMHPITNOTES et Nalls 95 SrFt q -, 1All roof stormwatcrrunoff ahaU Ix wlleeted by gutters 1)owa9pouts wen dttect stormwater towards 4L PROPOSED` HARDCOVER; 3� 235: Sq Ft awales cn can end war side of proposed home Swala shall route atorZoWUN to rear a�d front yard,. a 4 OF -LOT TO 01 : 'r S 868: S-It Ft restnc>,ag flow onto n6ghbomlg proper i ,t i , v " : • Iandscaprug rock beEs msmlled on east eDd west ode of proposed home Will reduce velocity of ENTAGE OFF HARDCOVER TO LOT 38 59 Rock kits shall not be Imed with'plesnc whsch wtD eUowsfor mfillrauonhetmnon of�arormwater s. t - ~r • A grass buffer of mm®um SLT,is proposed between Lake Ymirakbnte and all proposed hardcover j ' - .surfaces The grass iwffer will" filter stormwater runoff.1 p s r \ • 1 •� t '•4 - -h CT _ 1, } y /, \•F 1• t>SN9 DIR.10 ital'i�mm DATE ltURVE-YEQ 16�E TITLE' Id@I m 14PA� ar r o a m K!f n �: ra OWN aO altr I AN s oxv Lam) ) Cm'.-,-, AtLGl1sT 25 2018 s1�EET S� �j 7" ]f 22 r Advance M1�a suIIol®al st1RVEYEDtY ADVAetf El)sURV PROPOS '�'+Y 'i _Sgd a i ✓ t C SrffEFNO 3 :q� S: �. v i swv_e,9 a_�ei co aY4 fOATE DRAFTED• ,� To..w+�wa.ms asa+s -w a rots MAY,9 2oie y #.T90289JR e -*t l 1 it W k.�aavmn r �3( Ton ^ter � •;. a: i.x ��,;; �.r� �� � #'!�• +�' $may #e�.X�ij'����!¢t �ir.5 � '' 3�r�^ri����. _ r.t 24" Max � Cantilever V-1-1 Pressure Treated Titan Timber Glulam Deck Beam Post cap brackets Concrete footing design by others BEAM - 5-1/411 x 13-3/411(24F-1.8e) Southern Yellow Pine Pressure Treated Titan Timber Glulam Deck Beam Treated after lamination with MicroProTm/ AC2® To Ground Contact by Midwest Manufacturing. 60_P_SF_Uve-Load/_1D_P_SF Dead -Load Maximum Support Spacing Maximum Joist Span L+O��-..4 1 1 OI - 0" 1 21 - 016 1 II I II 141-011 20'-0" Deck beams are manufactured by Timber Technologies LLC. Material is treated after laminating with MicroProTm/ AC2 "by Midwest Manufacturing. General Notes: Live load deflection for beam is U360. Total load deflection for beam is limited to U240. ;. Ledger connection is critical. Consult deck designer for connection as well as proper beam, column and joist sizings. K Titan Timbers is a registered trademark of Timber Technologies U.C. TitanTiMber &lulam Beams Titan Timbers Glulam Beams Available from MENARDS Industrial Grade Glulam Beams 5-1 /4"x 13-3/4" ..(Available special order in approximately 1 week) Glulam length 16' 20' 24' Exterior Use (Pressure Treated) Glulam Beams 1064170 1064172 1064174 Interior Use Beams 1064470 1064472 1064474 Custom Glulam Beams (Available special order in approximately 4-5 weeks) Available Widths -3-1/4' , 5-1/4", 7"- and'9" Available Depths: 6-7/8" up to 42" (depending on design requirements) ,, -Available Lengths: Up to 48'. (available.in even lengths only) • :Atchitec#ural :Grade -when appearance is Important. Industrial Grade - for applications where appearance is not a primary concern. Pressure treated glulam beams are produced with durable, waterproof adhesives suitable for applications where the beam will be exposed to weather, insects, sunlight and high moisture conditions. l Pressure treatment is a process of infusing preservative chemicals to increase resistance to decay and does not affect the structural integrity of the beam. o The pressure treatment process may cause checking and raised grain as the beam dries. These are visual imperfections and do not affect the strength of the glulam. Titan Timbers is a registered trademark of Timber Technologies LLC._