Loading...
Permits - Permit# 08-12M - 4325 Channel Road - 1/1/2008CITY OF SPRING PARK 4349 WARREN AVENUE OCT 2 200, SPRING PARK, MINNESOTA 55384 952-471-9051 APPLICATION FOR MECHANICAL PERMIT GENERAL INFORMATION 1. You may apply for mechanical permits by mail or in person at the City offices. Applications will be reviewed and a permit will be issued within 2 working days. 2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON THE JOB SITE. 3. Mechanical Designs - Complete calculations, details and specifications are required for each heating, ventilation, humidification -dehumidification, and air conditioning installation including heat loss/heat gain calculation, design temperatures, equipment ratings and identification as to type, manufacturer and model. Data shall be presented on form provided. Identification of and specifications for water heating equipment shall also be provided. 4. When any new construction or remodeling is involved, a separate building permit must be obtained. 5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements. 6. All work must be inspected (rough -in and final). Call 952-249-4600. A 24 hour notice is required. 7. House Heating Test Record must be submitted before final. INSTRUCTIONS Complete all items on this application. Compute the permit fee. Sign and date the certification. INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call 952-249-4600 or 952-471-9051. Please check one: New Addition Repair _ Residential Commercial JOB SITE .2 '5- i : I Ins.( es Owner's Name \j ed 5 Mailing Address r Contractor's Name C I c Mailing Address 5 c SYSTEM DESCRIPTION HEATING SYSTEMS Quantity I Make Rupp Model UG A Id EZ &.S Fuel Flue Size a"A/C Input BTUs I00, Output BTUs 9S."Ce'o CFM � DO COOLING SYSTEMS Quantity 3f6* lys/rr Replace Phone Number CoioC- S" nC:) pCr: � 0e, Phone Number. Poor Quality Document Disclaimer The original or copy of a document or page of a document presented at the time of digital scanning contained within this digital file may be of substandard quality for viewing, printing or faxing needs. Mechanical Permit Make 66rrI' e✓ Model '2AS3V400'3 Tons 3 H. Power 3 WOOD BURNING EQUIPMENT Wood stove with flue Wood combination or add -on Factory fireplace with flue Factory fireplace(s) Freestanding Wood Stove (s) Franklin, other Brand name Mfgr's Min., Clearances, side rear VENTILATION No. No. No. Masonry Model N, min. flue dia. Total Kitchen exhaust - ducted recirculating Bath exhaust (must be ducted outside) Other fans: Locations FUEL STORAGE (MUST BE APPROVED BY FIRE MARSHALL) Installation Removal Fuel Oil gallons underground inside outside LP Gas gallons Other _ PERMIT FEE CALCULATION(S) 2002 State Statute Yes, This Section Applies Total gas opening cfm cfm cfm The replacement of a Residential fixture or appliance that meets all three of the following requirements: 1) Does not require modification to electrical or gas service. 2) Has a total cost of $500.00 or less excluding the cost of the fixture or appliance; and 3) Is improved, installed or replaced by the homeowner or licensed contractor. Skip next section; Cost of Permit $ $15.00 State Surcharge $ .50 Mail In Fee $ 1.50 1. 1.25% of Contract Price * or Minimum Fee 35.00 5.1-) x .0125 (Contract Price) 2. State Surcharge 1112 Add the State Buildin Code Division Surcharge to each permit. ySt�SJI x .0005 (Contract Price) or $.50, whichever is greater 3. Postage and Handling (Only mail -in applications) $ SC"Q - 31 $ $ 1.50 Mechanical Permit 4. TOTAL PERMIT FEE (Add lines 1-3 above) $ (0c k CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted work including materials, labor, profit, and other fixed costs. It is the amount to be charged to the customer for the work done. If any material, equipment, labor, or installation are furnished by the owner, tenant, or any other party, the reasonable market value of such items must be added to the estimated cost or contract price for permit fee purposes. In the event there is a dispute on the amount of the job cost, the City may request the submission of a signed copy of the actual contract. The STATE SURCHARGE is .0005 of the contract price under $1,000,000 or $.50, whichever is greater. For valuations over $1,000,000 call the Department of Inspectional Services for the price. The undersigned hereby applies to the City for issuance of a Mechanical Permit, agrees to do all work in strict accordance with the ordinances of the City and the regulations of the Minnesota State Building Code, and certifies that all statements made on app caw - e complete, true and correct. Applicant's Signatur -Date ��—� ,LA Approved By Date - 3 $ Permit: 56.31 Valuation $4,505.27 ,lo. 08-120 P & H: 1.50 State: 2.25 Total: 60.06 btate of Alinneoota City of Spring Park County of Hennepin } Office of Building Inspector ,4letba« tml Vermtt IN CONSIDERATION OF The statements and representations made by All Climate Heating & Cooling in application therefore duly filed in this office, which application is hereby made a part hereof, PERMISSION IS HEREBY GRANTED To said Steve Meyers as owner to install to a building described as follows: kind of construction (build, erect, install, add to, alter, repair, move, wreck, as the case may be) _ Furnace and AC change out Front of width in feet ; side or length in feet ;height in feet ; number of stories ; contents cubic feet; square feet, upon that tract of land described as follows: Lot Block ; plat or addition 4325 Channel Road 19-117-23-12-0034 which tract is of the size and area specified in said application. This permit is granted upon the express conditions that said owner and their contractors, agents, workers and employees, shall comply in all respects with the ordinances of the City of Spring Park ; that it does not cover the use of public property, such as streets, sidewalks, alleys, etc., for which special permits must be secured; and that it does not cover the following: none of the following (Electrical work, plumbing, heating, plastering, etc., if such there be.) for which special permits must be secured. Given under the hand of the Building Inspector of said City and its corporate seal and attested by its Clerk this 12th day of November Year 2008 Attest: Wendy Lewin, City Clerk MNSPECT Building Inspector Permit #: 08-12M City of Spring Park 4349 Warren Avenue, Spring Park, MN 55384 Mechanical Permit PINS: 19-117-23-12-0034 ADDRESS: 4325 Channel Road Permission is hereby granted to: All Climate Heating & Cooling To install or construct the improvements applied for. This permit is granted upon the condition that the person to whom it is granted, and his agents, employees and workmen, shall conform in all respects to the Ordinances of the City of Spring Park and to the Statutes of the State of Minnesota in such cases made and provided; this permit may be revoked at any time upon violation of any of the provisions of said Ordinances, Statutes, or for any misrepresentation in the application. Approved by MNSPECT, CBO Date: November 11, 2008 NOTE: This card must be placed in a conspicuous place at the address which work is to be performed. CITY OF SPRING PARK 4349 Warren Avenue, Spring Park, MN 55384 INSPECTION RECORD PINS 19-117-23-12-0034 Building Inspections — Permit No. 08-12M Footings Date Inspector Framing Insulation Wallboard B4 taping Final x Others ADDRESS 4325 Channel Road Plumbing Inspections — Permit # '" Date Inspector Rough -in Air Test Final Permit # Date Inspector Sewer Water Electric Note: Contractor is responsible to call for these inspections. This card must be placed in a conspicuous place, on the premises on which work is to be performed. 952-442-7520. df Sk�r'Qe. 9 �F* SpG3PHS PARK OH Zake M%HHEtOHka DATE: October 23, 2008 TO: Mnspect FROM: Wendy RE: Mechanical Permit MEMO Attached is a mechanical permit application. Unfortunately, we haven't replaced our old permit applications on our website with the new ones Brandy designed. We had intended to look them over a little closer and tweak them somewhat, if needed. We then discussed changing to the new permit applications at the first of the year. Why, I don't know. It just seemed to be a good time to do it. Anyway, this mechanical permit application attached was generated from our website. They did their own permit cost calculations and included a check for $60.06. This amount might be actually higher than what the new fee schedule would calculate. I'm thinking a mechanical permit for a furnace/AC change out on an established dwelling would be $38.50. If you agree, we can reimburse the contractor the difference. Thanks you guys. /wl oil o .. Proposal For I Building Mechanical Systems Proposal Date Service Job Number Page 687 - 1 of 2 Bill To Job Location Meyers, Steve Meyers, Steve 4325 Channel Road, 4325 Channel Road Spring Park, MN 55384 Spring Park,MN 55384 Attn: I Steve Attn: I Steve Meyers Contractor Will Provide The Following To The Customer this proposal is for the removal and disposal of the failed down flow furnace and air conditioner, installing one new RUUD high efficacy condensing furnace, installing a filter rack in the return duct, installing a new cased evaporator coil "3.5 ton", installing a new line set to the customer supplied condenser, connecting of the ducting to the new furnace, electrical and gas reconnection, permit fees and service labor. Note: We will connect the supplied condenser and charge system however there is no warranty on the condenser as it was supplied by the customer. The evaporator coil for this system is provided by us and will be covered under warranty. If you have any questions about this proposal please feel free to call me at 612-229-9839 Mark Four Thousand Five Hundred Five and 27/100 $4,505.27 As a Condition of performance, invoice payments must be made within ten (10) days of receipt. Any alterations or deviations from the above proposal involving extra cost of meterial or labor will become an extra charge over sum stated above. For the purpose of mobilization and/or equipment procurement, the contractor reserves the right to request a down payment not to exceed 50% of the sum stated above. This proposal will become a binding agreement only after acceptance by customer and approval of an officer of the contractor as evidenced by their signatures below. This agreement sets forth all to the terms and conditions binding on the parties hereto on page 2 hereof, and no person has authority to make any claim, representation, promise or condition on behalf of contrctor which is not expressed herein. All pricing is good for 30 days from the date of proposal. Contractor: All Climate Heating & Cooling Customer: Sales Assoc: Print Name: Si nature: Signature: Title: Title: Date: Date: All Climate Heating & Cooling 2520 Coon Rapids Blvd. Suite 120 Coon Rapids, MN 55433 Phone (763) 548-8095 Fax: (763) 421-1927 ACORCERTIFICATE OF LIABILITY INSURANCE AT (MIOD oe PRODUCER THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION WISE INSURANCE AGENCY INC ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR PO Box 647 ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. Chanhassen, MN 55317 (952)933-0352 INSURERS AFFORDING COVERAGE NAIC# INSURED All Climate Heating And Cooling LLC INSURERk INDIANA INSURANCE INSURER B: 2520 Coon Rapids Blvd, Suite 120 INSURER C: Coon Rapids, MN 55433 INSURER D: INSURER E COVERAGES THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. AGGREGATE LIMITS SHOWN MAYHAVE BEEN REDUCED BY PAID CLAIMS. INS LTR NBRDTYPE OF POLICY NUMBER AI Y E M POLICYEXPIRATION DAT MMID LIMITS GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 X COMMERCIAL GENERAL LIABILITY CLAIMSMADE 7OCCUR PREMISES Meoemaence $ 50 000 MEDEXP(Anyonepmon) $ 5,000 A CCP 8015540 03/20/08 03/20/09 PERSONAL BADVINJURY S 1,000,000 GENERAL AGGREGATE $ 2,000 000 GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS - COMP/OP AGG $ 2,000,000 POLICY JEoX LOC AUTOMOBILE LIABILITY ANYAUTO SINGLE LIMIT (a acciED dent) $ 1,000,000 ALL OWNED AUTOS X SCHEDULED AUTOS BODILY INJURY (Per person) $ A X HIRED AUTOS X NON-OWNEDAUTOS CCP 8015540 03/20/08 03/20/09 BODILY INJURY (Peraccident) $ PROPERTY DAMAGE (Peraccident) $ GARAGE LIABILITY AUTO ONLY -EA ACCIDENT $ OTHERTHAN EAACC $ ANYAUTO S AUTO ONLY: AGG EXCESS/UMBRELLALIABILITY X OCCUR ❑ CLAIMSMADE EACH OCCURRENCE S 2,000,000 AGGREGATE s 2,000,000 CU 8016740 03/20/08 03/20/09 S A DEDUCTIBLE $ $ 1 RETENTION S A WORKERS COMPENSATION AND EMPLOYERS' LIABILITY Nw FRavRtEroRmnRTNewFXIEcvrlve OFFK:ERNAMaI3t DICLLMEW Ryes desenbeunder SPECIAL PROVISIONS betow C 8016240 03/20/08 03/20/09 x I TORYLIMITS I I ER E L. EACH ACCIDENT S 500,000 E.L. DISEASE - EA EMPLOYE1 S 500,000 E.L. DISEASE - POLICY LIMIT $ 500,000 OTHER DESCRIPTION OF OPERATIONS I LOCATIONS / VEHICLES I EXCLUSIONS ADDED BY ENDORSEMENT / S°EC WL PROVISIONS HULLJEK City of Spring Park 4349 Warren Avenue Spring Park, MN 55384 ACORD 25 (2001/08) SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATIO DATE THEREOF. THE ISSUING INSURER WILL ENDEAVOR TO MAIL10 DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT. BUT FAILURE,yq 00 SO SHALL IMPOSE NO OBLIGATION OR LIABILITY OF ANY KIND UPON T]HE INSURER ITS AGENTS OR ©ACORD CORPORATION 1988 ACOR .- CERTIFICATE OF LIABILITY INSURANCE 10 99//� 08 PRODUCER THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION WISE INSURANCE AGENCY INC ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AMEND, EXTEND OR PO BOX 647 ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. Chanhassen, MN 55317 (952) 933-0352 INSURERS AFFORDING COVERAGE NAIC# INSURED All Climate Heating And Cooling LLC INSURERA INDIANA INSURANCE INSURER B: 2520 Coon Rapids Blvd, Suite 120 INSURER C: Coon Rapids, MN 55433 INSURER D: INSURER E. COVERAGES THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. IN9 ITR Nsab E OFINS RAN POLICY NUMBER DA I Y MggBRYE POLICYEXPIRATION DAT MM/DD LIMITS A GENERAL LIABILITY X COMMERCIALGENERALLIABILITY CLAIMSMADE OCCUR CCP 8015540 03/20/08 03/20/09 EACH OCCURRENCE S 1 000,000 PREMISES Eaocarence S 50,000 MEDEXP(Anyonepmon) S 5,000 PERSONAL SADVINJURY S 1,000,000 GEWL AGGREGATE LIMIT APPLIES PER X POLICY PRO. PRO. LOC GENERAL AGGREGATE S 2,000 000 PRODUCTS -COMP/OPAGG S 2,000,000 A AUTOMOBILE LIABILITY ANYAUTO ALL OWNED AUTOS SCHEDULED AUTOS HIRED AUTOS NON-OWNEDAUTOS CCP 8015540 03/20/08 03/20/09 (nntSINGLE LIMIT Eaaccidee S 1,000,000 BODILY INJURY (Per person) S X X BODILY INJURY (Peraccident) S X PROPERTY DAMAGE (Peraccident) S GARAGE LIABILITY ANYAUTO AUTO ONLY -EA ACCIDENT S OTHER THAN EAACC AUTOONLY: AGG S S A 1 EXCESS/UMBRELLA LIABILITY X OCCUR CLAIMSMADE DEDUCTIBLE RETENTION S CU 8016740 03/20/08 03/20/09 EACH OCCURRENCE S 2 OOO O00 AGGREGATE S 2,000,000 $ S S A WORKERS COMPENSATION AND EMPLOYERS'LIIPARTY ANY FnOPRIETgR/PpRTIVFREId:cIfTIVE OFFICEMMEMB A EXCUX1EW Ryes descnbeunder SPECIAL PROVISIONS below C 8016240 03/20/08 03/20/09 X I TORY LIMITS ER EL.EACH ACCIDENT S 500,000 E.L. DISEASE • EA EMPLOYEI S 500,000 E.LDISEAcm. •POI ICY LIMIT S 500,000 OTHER DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES/ EXCLUSIONS ADDED BY ENDORSEMENT I SPECIAL PROVISIONS Gt(tnl-IGAlt MULL)LK CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION City of Spring Park DATE THEREOF, THE ISSUING INSURER WILL ENDEAVOR TO MAJL10 DAYS WRITTEN 4349 Warren Avenue NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT. BUT FAILURE,Tq DO SO SHALL Spring Park, MN 55384 IMPOSE NO OBLIGATION OR LIABILITY OF ANY KIND UPON T}IE INSURER ITS AGENTS OR ACORD 2S (2001108) © ACORD CORPORATION 1988 IENNOX RESIDENTIAL HEATING DATA SHEET JOB NAME: fe e� DATE ADDRESS: Rd -a3y OUTDOOR TEMP: - INDOOR TEMP: 70 TEMP. DIFFERENCE: MOVABLE GLASS WINDOWS SQUARE FEET DESIGN TEMPERATURE DIFFERENCE BTUH HEAT LOSS 30 1 35 140 45 1 50 155 160 165 170 175 1 80 185 190 95 HEAT TRANSFER MULTIPLIER SINGLE GLASS is 4,5 39 45 52 58 65 71 78 84 90 97 103 110 1116 1123 SINGLE GLASS W/STORM 21 125 1 28 31 35 38 42 45 49 52 59�63 66DOUBLE GLASS 28 32 37 41 46 50 55 60 64 69 73 782 87 DOUBLE GLASS W/STORM 16 19 21 24 27 29 32 35 37 40 42 45 8 50 SLIDING GLASS DOORS [DOUBLE SQUARE FEET DESIGN TEMPERATURE DIFFERENCE BTUH HEAT LOSS 30 135 1 40 145 1 50 1 55 1 60 165 1 70 1 75 85 1 90 1 95 HEAT TRANSFER MULTIPLIER NGLE GLASS 42 48 55 62 69 76 83 90 97 104 110 117 124 131 NGLE GLASS W/STORM 22 26 29 33 37 40 44 48 51 55 59 62 66 70 GLASS cy frl 1 29 1 34 139 1 43 48 1 53 1 58 63 67 72 82 87 191 DOORS SQUARE E DESIGN TEMPERATURE DIFFERENCE STUH HEAT LOSS 30 35 140 145 1 50 155 1 60 65 170 175 1 W 1 85 1 90 195 HEAT TRANSFER MULTIPLIER SOLID WOOD 31 36 41 46 1 51 56 1 62 167 172 177 87 192 1 97 SOLID WOOD"" 18 21 27 33 36 39 42 45 47 50 53 56 METAL URETHANE 23 27 124 30 348 t3O 42 45 49 53 57 60 64 68 72 METAL URETHANE"" 13 16 18 202 25 F 27 129 31 133 36 38 140 42 "'Weatherstrip ed or Storm WALLS RUNNING FEET CEILING HEIGHT X 1 GROSS WALL = 1 3r61 ;;tG0 WINDOWS & DOOR AREAS NET WALL AREA LJ_21� FRAME WALL SQUARE FEET DESIGN TEMPERATURE DIFFERENCE BTUH HEAT LOSS 30 1 35 1 40 1 45 150 155 1 60 165 1 70 175 180 185 90 95 HEAT TRANSFER MULTIPLIER NO INSULATION 8 10 11 1 12 14 15 17 18 19 21 22 23 25 26 R-11, 3" INSULATION 2.7 3.1 3.6 4.0 4.5 4.9 5.4 5.8 6.3 6.7 7.2 7.6 8.1 8.5 R-13, 3-1/2" INSULATION 2.1 2.4 2.8 3.2 3.5 3.8 4.2 4.6 4.9 5.3 5. 5.9 6.3 6.6 , R-13 + 1" POLYSTYRENE 1.8 2.1 2.4 2.7 3.0 3.3 3.6 3.9 4.2 4.5 4.8 5.1 5.4 5.7 R-19 + 1 /2" POLYSTYRENE 1.6 1.9 2. 22.5 2.8 3. 33.3 3.6 3.8 4.1 4.4 4.7 MASONRY WALL ABOVE GRADE SQUARE FEET DESIGN TEMPERATURE DIFFERENCE BTUH HEAT LOSS 30 35 40 45 50 55 60 65 70 75 80 85 90 95 HEAT TRANSFER MULTIPLIER NO INSULATION 16 1 18 1 21 23 1 26 1 28 1 31 33 36 38 41 44 46 49 R-5, 1" INSULATION 4.3 15.0 15.8. 6.517.2 17.9 18.6 9.4 10.1 11.5 12.2 13.0 13.7 R-11, 3" INSULATION 2.3 2.7 3.1 3.513.8 4.2 4.6 5.0 5.46.2 936a 6.5 6.9 7.3 R-19, 6" INSULATION 1.4 1.7 1.9 2.2 2.4 2.6 2.9 3.1 3.4 3.8 4.1 MASONRY WALL_ -__ _. BELOW GRADE --._SQUARE__.-_ FEET DESIGN TEMPERATURE DIFFERENCE - - BTUH HEAT LOSS _ 30 35 45 50 55 60 65 70 75 80 85 90 95 HEAT TRANSFER MULTIPLIER O INSULATION 4.4 5.1 15.916.6 7.318.1 8.8 9.6 10.3 11.0 11.8 12.5 13.2 14.0 -5, 1" INSULATION [R-1 2.613.0 3.5 3.9 4.3 4.8 5.2 5.7 6.1 6.5 7.0 7.4 7.8 8.3 1, 3" INSULATION 1.82.1 2.4 2.7 3.0 3.3 3.6 3.9 4.2 4.5 4.8 5.1 5.4 5.7-19, 6" INSULATION 1.2 1.4 1.6 1.812.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.6 3.8 c 96 HEAT LOSS SUBTOTAL Heat Loss Subtotal from Page 1 CEILING SQUARE DESIGN TEMPERATURE DIFFERENCE BTUH HEAT LOSS 30 35 40 45 50 55 60 65 70 75 80 85 90 95 HEAT TRANSFER MULTIPLIER NO INSULATION 18 1 21 24 27 30 36 39 42 45 48 51 54 57 R-11, 3" INSULATION 2.6 3.1 3.5 4.0 4.4 5.3 5.7 6.2fi2. 7.0 7.5 7.9 8.4 R-19, 6" INSULATION 1.6 1.9 2.1 2.4 2.6 E1.4 3.2 3.4 3.7 4.5 4.8 5.0 R-30, 10" INSULATION 1.0 1.2 1.3 1.5 1.6 2.0 2.1 2.3 2.6 2.8 3.0 3.1 R-38, 12" INSULATION 0.8 0.9 1.0 1.2 1.3 1.6 1.7 1.8 2.1 2.2 2.3 2.5 FLOOR OVER AN UNCONDITIONED SPACE SQUARE FEET DESIGN TEMPERATURE DIFFERENCE BTUH HEAT LOSS 30 35 1 40 45 150 1 55 1 60 1 65 1 70 1 75 180 1 85 1 90 1 95 HEAT TRANSFER MULTIPLIER NO INSULATION 10 11 13 14 16 1 17 19 21 22 24 1 25 1 27 128 30 R-11, 3" INSULATION 2.4 2.8 3.2 3.6 14.0 4.4 4.8 5.2 5.6 6.0 16.4 6.8 7.2 7.6 R-19, 6"INSULATION 1.6 1.8 2.1 2.3 12.6 2.9 3.1 3.4 13.6 3.9 4.2 4.4 14.7 4.9 R-30, 10"INSULATION 1.1 11.3 1.5 11.7 11.8 12.5 2.2 2.4 12.6 2.8 13..n 3.1 133 3.5 BASEMENT FLOOR SQUARE FEET DESIGN TEMPERATURE DIFFERENCE BTUH HEAT LOSS 30 1 35 1 40 1 45 1 50 1 55 1 60 1 65 1 70 1 75 1 80 1 85 1 90 95 HEAT TRANSFER MULTIPLIER BASEMENT FLOOR 10.8 11.0 11.1 11.3 11.4 11.5 11.7 11.8 12.0 12.1 12.2 12.4 12.5 12.7 CONCRETE SLAB WITHOUT PERIMETER SYSTEM LINEAR FOOT DESIGN TEMPERATURE DIFFERENCE BTUH HEAT LOSS 30 35 40 45 50 55 60 65 70 75 80 85 90 95 HEAT TRANSFER MULTIPLIER NO EDGE INSULATION 25 29 33 1 37 41 145 1 49 1 53 1 57 1 61 1 65 1 69 1 73 77 1" EDGE INSULATION 13 1 15 117 1 19 21 123 1 25 1 27 129 1 31 35 1 37 139 2" INSULATION 6.3 F.4 18.4 19.4 10.5 11.5 12.6 13.6 14.7 15.8 6. 17.8 18.9 20.0 � 2, CONCRETE SLAB WITH PERIMETER SYSTEM 12" LINEAR FOOT DESIGN TEMPERATURE DIFFERENCE BTUH HEAT LOSS 30 135 140 145 1 50 155 1 60 1 65 1 70 1 75 1 80 1 85 190 95 HEAT TRANSFER MULTIPLIER NO EDGE INSULATION 57 f 67 1 76 1 86 1 95 1105 1114 1124 1133 1143 1152 1162 171 181 1" EDGE INSULATION 34 40 46 1 52 1 57 1 63 1 69 1 74 1 80 1 86 191 1 97 103 109 EDGE INSULATION 1 28 133 137 1 42 1 47 1 51 1 56 1 61 1 65 1 70 1 75 1 79 1 84 89 An additional infiltration load is calculated QTly if the home i_ s IooseL r when window infiltration is greater than .5 CFM per linear foot of crack. - ..._. FLOOR SO. Fr. x CEILING HEIGHT = ___ CUBIC FT INFILTRATION/ VENTILATION 0.40 x CUBIC FT _ 60 = CFM MECHANICAL VENTILATION CFM = FRESH AIR INTAKE DESIGN TEMPERATURE DIFFERENCE CFM BTUH 30 35 40 45 1 50 1 55 1 60 1 65 1 70 1 75 1 80 85 90 195 HEAT LOSS HEAT TRANSFER MULTIPLIER INFILTRATION 33 39 44 50 55 1 61 1 66 1 72 1 77 1 83 1 88 94 99 105 MECHANICAL VENTILATION 33 39 44 50 55 1 61 1 66 1 72 1 -7 1 83 188 94 99 1 105 HEAT _OSS SUBTOTAL Q DUCT LOSS BTUH HEAT LOSS R-4, 1" Flexible Blanket Insulation: ADD 15% (.15) R-7, 2" Flexible Blanket Insulation: ADD 10% (.10) TOTAL HEAT LOSS NOTE: All Heat Transfer Multipliers from ACCA Manual "J" Sixth Edirion. tnr..: i(I1(�lti) MINNGSOTA OEP.�RTMENT OF uwnuo:w nc'�wwrlw,;wr Ur m LABOR &INDUSTRY +LABOR &INDUSTRY Construction Codes and Licensing Division Construction Codes and Licensing Division Commissioner of Labor and Industry Commissioner of Labor and Industry Has Received and Filed a S25,000 Surety Bond, Has Received and Filed a $25 000 Surety Bond As Required by'MS 3 ech, for Work Regulated > > Mechanical by the State �•Ianical Code As Required by MS 326.992, for Work Regulated To: Guy Krantz Bond No: BDA 790065343E by the State Mechanicai Code All Climate I[eating & (tooling NIB ID: 02030 LLC To: All Krantz Bond No: BDA. 7900658439 Effective Date Eriiration Date All Climate Heating & Cooling LLC MB ID: 02080 5/11/2008 5/10/2009 2520 Coon Rapids Blvd. Suite 120 Coon Rapids MN 55433 Effective Date Expiration Date 5/11/2008 5/10/2009 MBFormRC Permit #: 08-12M City of Spring Park 4349 Warren Avenue, Spring Park, MN 55384 Mechanical Permit PINS: 19-117-23-12-0034 ADDRESS: 4325 Channel Road Permission is hereby granted to: All Climate Heating & Cooling To install or construct the improvements applied for. This permit is granted upon the condition that the person to whom it is granted, and his agents, employees and workmen, shall conform in all respects to the Ordinances of the City of Spring Park and to the Statutes of the State of Minnesota in such cases made and provided; this permit may be revoked at any time upon violation of any of the provisions of said Ordinances, Statutes, or for any misrepresentation in the application. Approved by MNSPECT, CBO Date: November 11, 2008 NOTE: This card must be placed in a conspicuous place at the address which work is to be performed. CITY OF SPRING PARK 4349 Warren Avenue, Spring Park, MN 55384 INSPECTION RECORD PINS 19-117-23-12-0034 Building Inspections — Permit No. 08-12M Footings Date Inspector Framing Insulation Wallboard 134 taping Final x Others ADDRESS 4325 Channel Road Plumbing Inspections — Permit # "* Date Inspector Rough -in Air Test Final Permit # Date Inspector Sewer Water 'Electric Note: Contractor is responsible to call for these inspections. This card must be placed in a_conspicuous_place,_on_the-premises-on- which -work- is -to -be -performed. 952-442-7520. CIZ CITY OF SPRING PARK 4349 WARREN AVENUE OCT 22 Z SPRING PARK, MINNESOTA 55384 952-471-9051 APPLICATION FOR MECHANICAL PERMIT GENERAL INFORMATION 1. You may apply for mechanical permits by mail or in person at the City offices. Applications will be reviewed and a permit will be issued within 2 working days. 2. Permit cards will be sent by return mail after a review is completed. PERMITS ARE NOT VALID UNTIL YOU RECEIVE A PERMIT. WORK MUST NOT BEGIN UNTIL THE PERMIT CARD IS POSTED ON THE JOB SITE. 3. Mechanical Designs - Complete calculations, details and specifications are required for each heating, ventilation, humidification -dehumidification, and air conditioning installation including heat loss/heat gain calculation, design temperatures, equipment ratings and identification as to type, manufacturer and model. Data shall be presented on form provided. Identification of and specifications for water heating equipment shall also be provided. 4. When any new construction or remodeling is involved, a separate building permit must be obtained. 5. All work must be done in accordance with the Uniform Mechanical Code/State Building Code requirements. 6. All work must be inspected (rough -in and final). Call 952-249-4600. A 24 hour notice is required. 7. House Heating Test Record must be submitted before final. INSTRUCTIONS Complete all items on this application. Compute the permit fee. Sign and date the certification. INCOMPLETE APPLICATIONS WILL NOT BE PROCESSED. If you have questions, call 952-249-4600 or 952-471-9051. Please check one: New Addition Repair Replace Residential >( Commercial JOB SITES Owner's Name Mailing Address Contractor's Name Mailing Address SYSTEM DESCRIPTION HEATING SYSTEMS Quantity l Make AuoD Model UG A /a EZ Ads Fuel J16- Flue Size Input BTUs lOD 01V Output BTUs rs coo CFM / .� DO COOLING SYSTEMS Quantity 1 3 fan /ys/rr Mechanical Permit Make Ccwi ev Model 3 Tons 3 H. Power 3 WOOD BURNING EQUIPMENT Wood stove with flue Wood combination or add -on Factory fireplace with flue Factory fireplace(s) Wood Stove (s) Brand name Mfgr's Min., Clearances, side VENTILATION No. No. No. Freestanding Franklin, other rear Masonry Model N min. flue dia. Total Kitchen exhaust - ducted recirculating Bath exhaust (must be ducted outside) Other fans: Locations FUEL STORAGE (MUST BE APPROVED BY FIRE MARSHALL) Installation Removal Fuel Oil gallons underground inside outside LP Gas gallons Other PERMIT FEE CALCULATION(S) 2002 State Statute Yes, This Section Applies cfm cfm cfm Total gas opening The replacement of a Residential fixture or appliance that meets all three of the following requirements: 1) Does not require modification to electrical or gas service. 2) Has a total cost of $500.00 or less excluding the cost of the fixture or appliance; and 3) Is improved, installed or replaced by the homeowner or licensed contractor. Skip next section; Cost of Permit $ $15.00 State Surcharge $ .50 Mail In Fee $ 1.50 1. 1.25% of Contract Price * or Minimum Fee 35.00 x .0125 (Contract Price) 2. State Surcharge ** Add the State Buildin Code Division Surcharge to each permit. L4S -) x .0005 (Contract Price) or $.50, whichever is greater 3. Postage and Handling (Only mail -in applications) 2 $ 5(-p - 3 I $ 1.50 Mechanical Permit 4. TOTAL PERMIT FEE (Add lines 1-3 above) $ (_00 CONTRACT PRICE or JOB COST means the actual or estimated dollar amount charged for the permitted work including materials, labor, profit, and other fixed costs. It is the amount to be charged to the customer for the work done. If any material, equipment, labor, or installation are furnished by the owner, tenant, or any other party, the reasonable market value of such items must be added to the estimated cost or contract price for permit fee purposes. In the event there is a dispute on the amount of the job cost, the City may request the submission of a signed copy of the actual contract. Ka` The STATE SURCHARGE is .0005 of the contract price under $1,000,000 or $.50, whichever is greater. For valuations over $1,000,000 call the Department of Inspectional Services for the price. The undersigned hereby applies to the City for issuance of a Mechanical Permit, agrees to do all work in strict accordance with the ordinances of the City and the regulations of the Minnesota State Building Code, and certifies that all statements made on _ app ca jo -are complete, true and correct. Applicant's Approved By to I c�A, LJ 4e $ Permit: 56.31 Valuation $4,505.27 ,moo. 08 -121% P & H: 1.50 State: 2.25 Total: 60.06 estate of Ainneoota City of Spring Park County of Hennepin } Office of Building Inspector ftletbanical hermit IN CONSIDERATION OF The statements and representations made by All Climate Heating & Cooling in application therefore duly filed in this office, which application is hereby made a part hereof, PERMISSION IS HEREBY GRANTED To said Steve Meyers as owner to install to a building described as follows: kind of construction (build, erect, install, add to, alter, repair, move, wreck, as the case may be) Furnace and AC change out Front of width in feet ; side or length in feet ; height in feet ; number of stories ; contents cubic feet; square feet, upon that tract of land described as follows: Lot Block ; plat or addition 4325 Channel Road 19-117-23-12-0034 which tract is of the size and area specified in said application. This permit is granted upon the express conditions that said owner and their contractors, agents, workers and employees, shall comply in all respects with the ordinances of the City of Spring Park ; that it does not cover the use of public property, such as streets, sidewalks, alleys, etc., for which special permits must be secured; and that it does not cover the following: none of the following (Electrical work, plumbing, heating, plastering, etc., if such there be.) for which special permits must be secured. Given under the hand of the Building Inspector of said City and its corporate seal and attested by its Clerk this 12th day of November Year 2008 Attest: Wendy Lewin, City Clerk MNSPECT Building Inspector